VibeFlow FDS
This skill is responsible for using FDS as VibeCAE's backend for fire dynamics, smoke spread, ventilation, thermal hazards, and fire-safety engineering.
- Usage mode: generate
.fdsinput fromcaseDict, run FDS, and read.out, CSV, and Smokeview files. - Development mode: develop FDS input templates, fire-source/material libraries, scene generators, post-processors, or Smokeview integration scripts.
When to Use
- The user task involves fire, smoke, heat release rate, ventilation, sprinklers, thermal radiation, visibility, temperature probes, or building-space safety assessment.
.fdsfiles need to be generated or repaired._hrr.csv,_devc.csv,.smv, slice, boundary, particle, or isosurface outputs need to be read.- Visualization handoff to Smokeview or ParaView is needed.
First Decide: Usage Mode or Development Mode
- Current scene modeling, execution, and post-processing: use usage mode.
- Template libraries, building-scene generators, material/combustion parameter libraries, or post-processing tools: use development mode.
- If FDS/Smokeview commands are unavailable or MPI issues occur, switch to
vibeflow-toolchainfirst. - If geometry comes from CAD or BIM and requires preprocessing, switch to the geometry/mesh-related skill first.
What to Read First
- The spatial dimensions, obstructions, vents, fire sources, materials, mesh, probes, output objectives, and safety metrics in
0-caseDict/caseDict. references/fds-playbook.mdreferences/fds-practical-tips.md: software knowledge base, key concepts, failure interpretation, and adapter design points.- Existing
.fdsfiles, material parameters, or experimental conditions inC-run/fds/andRef/.
Inputs
0-caseDict/caseDict- Building/compartment dimensions, fire-source curves, material thermophysical properties, ventilation boundaries, and probe locations
- FDS input files or public benchmarks
Outputs
C-run/fds/case-*/case.fdsC-run/fds/case-*/Allrun/Allclean- FDS logs,
.smv, CSV, and slice/boundary/particle outputs D-post/fds_postprocess.py- Charts for temperature, smoke layer, HRR, visibility, probes, and safety metrics
Recommended Structure
C-run/fds/
└── case-1/
├── case.fds
├── logs/
├── outputs/
├── Allrun
└── Allclean
D-post/
└── fds_postprocess.py
Usage Mode Workflow
- Map
caseDictto FDS namelists:&HEAD,&MESH,&TIME,&REAC,&MATL,&SURF,&OBST,&VENT,&DEVC,&SLCF,&BNDF, and&TAIL. - Check units, mesh size, fire-source heat release rate, combustion model, and output frequency.
- Generate
case.fds, ensuring that mesh blocks, obstructions, and boundaries do not contradict each other. - Run a short smoke test to confirm input parsing, valid geometry, and output-file generation.
- Run the production case and record
.out, CSV, and visualization files. - Post-process HRR, device curves, temperature/velocity/smoke slices, and key safety metrics.
- Write run status, physical assumptions, failure reasons, and output records back to
caseDict.
Development Mode Workflow
- Define the development target: input templates, room/building generators, material libraries, fire-source libraries, post-processing scripts, or Smokeview tasks.
- Write development notes first, recording namelist interfaces, default parameters, validation scenarios, and risks.
- All templates must explicitly preserve units and safety-related assumptions.
- For post-processors, prefer reading CSV and structured outputs rather than relying on manual image inspection.
- Validate parsing and short runs with at least one small room/simple fire source.
Core Rules
- Length units in FDS input are usually SI, and units in
caseDictmust be consistent. MESHresolution directly affects LES quality; do not optimize only for "runs quickly".- Fire sources, materials, ventilation, and boundary conditions must be checked as a coupled set.
- Output frequency must balance evidence needs and file size.
- Smokeview is a visualization entry point, not a substitute for numerical post-processing evidence.
Validation
- The FDS executable is available.
- The
.fdsfile parses successfully. - A short run generates
.out, CSV, or.smv. - The post-processing script can read key outputs.
- Key safety metrics correspond to the user's objectives.
Fallback Rules
- Insufficient fire-source/material/ventilation information: return to
vibeflow-case-dict - FDS environment unavailable: return to
vibeflow-toolchain - Geometry input conflicts: return to the geometry stage
- Outputs insufficient to support reporting: return to the post-processing stage