Key Parameters (from handbook)
Preheat Zone
- Temperature range: 100°C to 150°C
- Max ramp rate: 2°C/second
- Ramp rate equation: ΔT/Δt (temperature change over time change)
TAL (Wetting Time)
- Window: 30 to 60 seconds
- Measured as time solder is above its melting (liquidus) point
- Liquidus is paste-specific (from MES solder_liquidus_c column)
Peak Temperature
- Must exceed liquidus by approximately 20°C
- Required min peak = solder_liquidus_c + 20
Conveyor Speed
- LINE SPEED (MIN) = boards_per_min × board_length_cm / loading_factor
- Actual speed must be >= minimum line speed
Representative Thermocouple
- Handbook says to thermocouple the largest and smallest device
- TC at "largest_mass" location represents the coldest spot (hardest to heat)
- Use largest_mass TC for compliance checks (minimum peak, TAL)
Usage
import sys
sys.path.insert(0, '/app/environment/skills/evo-reflow-handbook-parser/scripts')
from utils import get_all_handbook_params, parse_preheat_params, parse_tal_params
params = get_all_handbook_params()