Simbiology simulate model

From matlab/matlab-agentic-toolkit · View interactive version

Simbiology simulate model is an AI agent skill from the GitHub repository matlab/matlab-agentic-toolkit. Simulate SimBiology models — ODE, stochastic (SSA), scenarios, and sensitivity analysis. Use when asked to run, simulate, predict, explore what-if, or identify influential parameters.

How to use this skill

Skill file

Simulate SimBiology Models

Run simulations of SimBiology models: deterministic ODE, stochastic SSA,

scenario exploration, and sensitivity analysis.

When to Use

When NOT to Use

Must-Follow Rules

0. Add helper scripts to the MATLAB path first

Run at the start of every session:

addpath(fullfile('<WORKSPACE_ROOT>', '.claude', 'skills', 'simbiology-simulate-model', 'scripts'));

1. Element-wise operators in observables

Use ./ and .* (element-wise) in observable expressions when mixing

time-varying species with constant parameters. Plain / and * cause

size mismatches at simulation time.

2. StatesToLog for constant parameters

When observables reference constant parameters (e.g., Drug ./ Vd),

add those parameters explicitly to StatesToLog:

cs.RuntimeOptions.StatesToLog = [m.Species; sbioselect(m,'Type','parameter','Name','Vd')];

StatesToLog = 'all' does not log constant compartments or parameters.

3. All reactions must be MassAction for SSA

The stochastic solver does not support custom rate expressions. Every

reaction must use addkineticlaw(rx, 'MassAction').

4. Do NOT combine Scenarios with `+`

The + operator is not supported on SimBiology.Scenarios objects.

Always use add() to append entries.

5. Reset local sensitivity options after use

Local sensitivity settings persist on the configset and affect

subsequent simulations. Always reset:

cs.SolverOptions.SensitivityAnalysis = false;
cs.SensitivityAnalysisOptions.Inputs = [];
cs.SensitivityAnalysisOptions.Outputs = [];

6. Set `MaximumWallClock` to prevent hung simulations

When fitting or scanning, bad parameter values can make individual

simulations extremely slow. Protect against this:

cs.MaximumWallClock = 60;  % seconds; default is Inf

This is a configset property (not a solver or optimizer option).

It stops any single simulation that exceeds the wall clock limit.

7. Unit conversion requires `TimeUnits`

When cs.CompileOptions.UnitConversion = true, you MUST also set

cs.TimeUnits to match your StopTime units (e.g., 'hour').

Otherwise SimBiology defaults to seconds and your 24-unit simulation

covers 24 seconds, not 24 hours:

cs.CompileOptions.UnitConversion = true;
cs.TimeUnits = 'hour';
cs.StopTime = 24;  % now correctly 24 hours

8. Scenario results are interleaved, not blocked

Factorial scenario results come back interleaved by the first dimension.

Always use generate(sc) to map result indices to conditions — never

assume all entries of one factor appear consecutively.

Decision Table

| Scenario | Approach |

|----------|----------|

| One-off simulation | sbiosimulate |

| Parameter sweep / Monte Carlo | createSimFunction |

| Dose/variant/parameter what-if | SimBiology.Scenarios + createSimFunction |

| Low molecule count / noise | SSA solver (cs.SolverType = 'ssa') |

| Which parameters matter? | sbiosobol (Sobol) or sbioelementaryeffects (Morris) |

| Quick sensitivity check | Local sensitivity via configset |

Basic Simulation (`sbiosimulate`)

Prefer returning SimData (single output) — it carries state names,

units, and metadata, and works directly with sbioplot and selectbyname:

m = getModelByUUID(modelId);
cs = getconfigset(m, 'active');
cs.StopTime = 24;
cs.SolverType = 'ode15s';
simData = sbiosimulate(m);

With a dose (configset is required as 2nd argument when passing doses):

d = sbiodose('Bolus', 'schedule');
d.TargetName = 'Drug'; d.Amount = 100; d.Time = 0;
simData = sbiosimulate(m, cs, d);  % NOT sbiosimulate(m, d) — errors

Plotting Results

Use sbioplot for quick visualization of SimData:

simData = sbiosimulate(m, cs, d);
sbioplot(simData);

For custom plots, extract numeric data first:

[t, x, names] = getdata(simData);
plot(t, x);
legend(names, 'Interpreter', 'none');
xlabel('Time'); ylabel('Amount');

Extracting State Data from SimData

Use selectbyname to extract specific states. It returns a **SimData

object**, not a numeric array — extract numeric data before doing math:

simData = sbiosimulate(m, cs, d);
result = selectbyname(simData, 'Central.Drug');  % returns SimData, NOT double
drugData = result.Data;   % numeric column vector
drugTime = result.Time;   % time column vector

Or use getdata() to get arrays:

[t, x, names] = getdata(selectbyname(simData, 'Central.Drug'));

For quick numeric access to all states without SimData, use the

three-output form:

[t, x, names] = sbiosimulate(m, cs, d);  % t, x are double arrays directly

Acceleration (`sbioaccelerate`)

For repeated sbiosimulate calls on the same model, accelerate once first:

sbioaccelerate(m);
simData = sbiosimulate(m);  % faster

Rules:

Repeated Simulation (`createSimFunction`)

% Signature: createSimFunction(model, params, observables, dosedSpecies)
simfun = createSimFunction(model, {'ke','ka'}, {'Drug'}, []);
r1 = simfun([0.1, 0.5], 24);           % single run
r2 = simfun([0.1, 0.5; 0.3, 1.0], 24); % multiple parameter sets (rows)
[t, x] = r1.getdata();

SimFunction with doses

The 4th argument to createSimFunction declares which species receive

doses. When executing, pass doses as a table (NOT a dose object):

% Create: specify dosed species names in 4th argument
simfun = createSimFunction(model, {'ke'}, {'Drug'}, {'Drug'});

% Execute: pass dose as a table with Time and Amount columns
doseTable = table(0, 100, 'VariableNames', {'Time', 'Amount'});
result = simfun(0.1, 24, doseTable);

% Multiple dose events
multiDose = table([0; 12], [100; 50], 'VariableNames', {'Time', 'Amount'});
result = simfun(0.1, 24, multiDose);

% Multiple dosed species: cell array of tables (one per species, same order)
simfun2 = createSimFunction(model, {'ke'}, {'Drug','Drug2'}, {'Drug','Drug2'});
doses = {doseTable1, doseTable2};
result = simfun2(0.1, 24, doses);

Common mistake: passing a sbiodose object to a SimFunction — this

errors. Always convert to a table with Time and Amount columns.

Scenarios (`SimBiology.Scenarios`)

Systematically explore combinations of doses, variants, and parameters.

`add()` signature (argument order is critical)

add(sc, combination, name, values, ...)
%     ^^^^^^^^^^^^^
%     MUST be 2nd argument: 'cartesian' or 'elementwise'

The combination type ('cartesian' or 'elementwise') is **always the

second argument** to add(). Putting it elsewhere errors.

Dose sweep

d1 = sbiodose('Low','schedule'); d1.TargetName = 'Drug'; d1.Amount = 50; d1.Time = 0;
d2 = sbiodose('High','schedule'); d2.TargetName = 'Drug'; d2.Amount = 200; d2.Time = 0;
sc = SimBiology.Scenarios('DoseLevel', [d1, d2]);

Full factorial (dose x parameter)

sc = SimBiology.Scenarios('DoseLevel', [d1, d2]);
add(sc, 'cartesian', 'ke', [0.05 0.1 0.2]);  % 2 x 3 = 6 combinations
simfun = createSimFunction(model, sc, {'Drug'}, []);
results = simfun(sc, 24);

Parameter sweep with dosed SimFunction

sc = SimBiology.Scenarios('ke', [0.05 0.1 0.2]);
simfun = createSimFunction(model, sc, {'Drug'}, {'Drug'});
doseTable = table(0, 100, 'VariableNames', {'Time', 'Amount'});
results = simfun(sc, 24, doseTable);  % dose table as 3rd argument

Result ordering (critical)

Scenario results are interleaved by the first dimension, not blocked.

For a 2-dose × 3-ke factorial, results come back as:

results(1): Dose1, ke1
results(2): Dose2, ke1
results(3): Dose1, ke2
results(4): Dose2, ke2
results(5): Dose1, ke3
results(6): Dose2, ke3

Use generate(sc) to get a table mapping each result index to its conditions:

genTable = generate(sc);  % table with one row per scenario
for i = 1:numel(results)
    [t, x] = results(i).getdata();
    fprintf('Dose=%s, ke=%.2f: Drug at t=end = %.2f\n', ...
        genTable.DoseLevel(i).Name, genTable.ke(i), x(end,1));
end

Never assume blocked ordering (all of Dose1 first, then all of Dose2).

Always use generate(sc) to map results to conditions.

Entry types

| Content Type | Example |

|---|---|

| Dose vector | SimBiology.Scenarios('DoseLevel', [d1, d2]) |

| Variant vector | SimBiology.Scenarios('Pop', [v1, v2]) |

| Parameter values | SimBiology.Scenarios('ke', [0.05 0.1 0.2]) |

| Species values | SimBiology.Scenarios('Drug', [50 100 200]) |

| Probability distribution | add(sc, 'elementwise', 'ke', makedist('Lognormal',...), 'Number', 50) |

Virtual population via distribution sampling

Scenarios can sample from probability distributions — use this for virtual

patient simulations instead of manually generating parameter matrices:

pd = makedist('Lognormal', 'mu', log(0.1), 'sigma', 0.3);
sc = SimBiology.Scenarios;
add(sc, 'elementwise', 'ke', pd, 'Number', 50);
simfun = createSimFunction(model, sc, {'Drug'}, []);
results = simfun(sc, 24);

Steady-state with repeat dosing

d = sbiodose('RepeatDose', 'repeat');
d.TargetName = 'Drug'; d.Amount = 100;
d.StartTime = 0; d.Interval = 12; d.RepeatCount = 50;
cs.StopTime = d.Interval * (d.RepeatCount + 1);
[t, x, names] = sbiosimulate(model, cs, d);

Stochastic Simulation (SSA)

For low molecule count systems where continuous ODE breaks down.

Single trajectory

cs = getconfigset(model, 'active');
cs.SolverType = 'ssa';
cs.StopTime = 100;
simData = sbiosimulate(model);
[t, x, names] = getdata(simData);

Ensemble (multiple trajectories)

nRuns = 200;
allResults = cell(nRuns, 1);
for i = 1:nRuns
    allResults{i} = sbiosimulate(model);
end

Gene expression template (all MassAction)

model = sbiomodel('GeneExpr');
comp = addcompartment(model, 'cell');
addspecies(comp, 'Gene', 1);
addspecies(comp, 'mRNA', 0);
addspecies(comp, 'Protein', 0);
addparameter(model, 'k_txn', 0.1);
addparameter(model, 'k_tln', 0.5);
addparameter(model, 'k_mdeg', 0.05);
addparameter(model, 'k_pdeg', 0.01);

% Transcription: Gene -> Gene + mRNA (Gene is catalyst)
rx1 = addreaction(model, 'Gene -> Gene + mRNA');
kl1 = addkineticlaw(rx1, 'MassAction'); kl1.ParameterVariableNames = {'k_txn'};
% Translation: mRNA -> mRNA + Protein
rx2 = addreaction(model, 'mRNA -> mRNA + Protein');
kl2 = addkineticlaw(rx2, 'MassAction'); kl2.ParameterVariableNames = {'k_tln'};
% Degradation
rx3 = addreaction(model, 'mRNA -> null');
kl3 = addkineticlaw(rx3, 'MassAction'); kl3.ParameterVariableNames = {'k_mdeg'};
rx4 = addreaction(model, 'Protein -> null');
kl4 = addkineticlaw(rx4, 'MassAction'); kl4.ParameterVariableNames = {'k_pdeg'};

After SSA, reset solver: cs.SolverType = 'ode15s';

Sensitivity Analysis

Sobol (global, quantitative)

bounds = [0.01 1; 0.1 5];  % [low high] per parameter
sobolResults = sbiosobol(m, {'ke','ka'}, {'Drug'}, ...
    'OutputTimes', 0:1:24, 'NumberSamples', 500, 'Bounds', bounds);
plot(sobolResults);

% Extract indices from struct array
for i = 1:numel(sobolResults.SobolIndices)
    Si  = mean(sobolResults.SobolIndices(i).FirstOrder, 'omitnan');
    STi = mean(sobolResults.SobolIndices(i).TotalOrder, 'omitnan');
    fprintf('%s: Si=%.3f, STi=%.3f\n', sobolResults.SobolIndices(i).Parameter, Si, STi);
end

Morris screening (global, ranking)

bounds = [0.01 1; 0.1 5];
eeResults = sbioelementaryeffects(m, {'ke','ka'}, {'Drug'}, ...
    'OutputTimes', 0:1:24, 'NumberSamples', 50, 'Bounds', bounds);

Local sensitivity

cs.SolverOptions.SensitivityAnalysis = true;
cs.SensitivityAnalysisOptions.Normalization = 'Full';
cs.SensitivityAnalysisOptions.Inputs = sbioselect(m,'Type','parameter','Name',{'ke','ka'});
cs.SensitivityAnalysisOptions.Outputs = sbioselect(m,'Type','species','Name','Drug');
simData = sbiosimulate(m);
[t, R] = getsensmatrix(simData);
% IMPORTANT: Reset after use
cs.SolverOptions.SensitivityAnalysis = false;
cs.SensitivityAnalysisOptions.Inputs = [];
cs.SensitivityAnalysisOptions.Outputs = [];

| Normalization | Meaning |

|---|---|

| 'None' | Raw dY/dp |

| 'Half' | (p/y) dY/dp |

| 'Full' | Dimensionless; both sides normalized |

Conventions

```matlab

proj = sbioloadproject('file.sbproj');

fn = fieldnames(proj);

model = proj.(fn{1});

```

References

Load on demand for detailed guidance:


Copyright 2026 The MathWorks, Inc.


Use this skill with your AI agent: Open on Skill Issue to copy, download, or add to your library. Works with Claude, ChatGPT, Gemini, Cursor, Windsurf and more.