Simbiology build model

From matlab/matlab-agentic-toolkit · View interactive version

Simbiology build model is an AI agent skill from the GitHub repository matlab/matlab-agentic-toolkit. Build, modify, and diagram SimBiology models — API reference, helper functions, and layout patterns. Use when constructing or editing models programmatically or visually.

How to use this skill

Skill file

Build SimBiology Models

API reference, helper functions, and patterns for building, modifying, and

diagramming SimBiology models. Works in all MATLAB environments (desktop,

headless, batch, remote). Diagram/layout features require the Model Builder

app and are activated only when the user requests visual output.

When to Use

When NOT to Use

Must-Follow Rules

1. Add helper scripts to the MATLAB path first

Run at the start of every session:

addpath(fullfile('<WORKSPACE_ROOT>', '.claude', 'skills', 'simbiology-build-model', 'scripts'));
disp('Helper scripts added to path.')

2. Only open the Builder when needed

Do NOT open the Model Builder by default. Open it when:

diagram layout/styling (sbioloadproject loses this data)

A model is fully functional without a diagram — it can be simulated,

fitted, and analyzed using only the model object on sbioroot.

3. Model construction uses standard SimBiology API

Build models using addcompartment, addspecies, addreaction, etc.

directly. This works in all environments: desktop, headless, batch, remote.

model = sbiomodel('MyModel'); disp(model.uuid)
comp = addcompartment(model, 'Central', 1);
addspecies(comp, 'Drug', 100);
addparameter(model, 'ke', 0.1);
rx = addreaction(model, 'Central.Drug -> null');
kl = addkineticlaw(rx, 'MassAction');
kl.ParameterVariableNames = {'ke'};

For standard PK models (1- or 2-compartment with standard dosing and

elimination), use references/pk-library-guidance.md as the reference for

correct parameterization, naming, and rules. When no diagram is needed,

call PKModelDesign directly. When the user requests a diagram, construct

the model manually following the same PK library conventions but use

addAndPositionCompartment for layout control (see Rule 8b).

4. Write reactions in the biological forward direction

The diagram renders arrows on products and plain lines on reactants

(based on the forward direction of the reaction string). Writing a reaction

backwards produces incorrect arrows even if the kinetics are equivalent.

% CORRECT — L and R get plain lines, C gets an arrow
addreaction(model, 'cell.L + cell.R <-> cell.C');

% WRONG — same kinetics but L and R get arrows (they're "products" now)
addreaction(model, 'cell.C <-> cell.L + cell.R');

Guidelines:

5. Always use qualified names for species and reaction-scoped parameters

Always reference species and reaction-scoped parameters by their qualified name. If any of the names are not valid MATLAB variable names, surround them with square brackets before building the qualified name.

Qualification is always exactly one level deep — the immediate parent

compartment only. Multi-level paths like Body.Central.Drug are invalid

in reaction strings. This is never ambiguous because compartment names must

be globally unique across the entire model (SimBiology enforces this

regardless of nesting depth). So Central.Drug is always sufficient.

Compartment naming rules:

share a name even at different nesting levels

nested compartments both named Central)

different compartments (disambiguated by Compartment.Species)

6. Use modern property names (`Value`, `Units`, `Constant`)

SimBiology objects (species, compartments, parameters) share a unified

property interface. Always use the modern names:

| Modern | Deprecated (do NOT use) | Applies to |

|--------|------------------------|------------|

| Value | InitialAmount, Capacity | species, compartments, parameters |

| Units | InitialAmountUnits, CapacityUnits, ValueUnits | species, compartments, parameters |

| Constant | ConstantAmount, ConstantCapacity, ConstantValue | species, compartments, parameters |

sp.Value = 100;       % NOT sp.InitialAmount
sp.Units = 'milligram';  % NOT sp.InitialAmountUnits
sp.Constant = false;  % NOT sp.ConstantAmount

comp.Value = 1;       % NOT comp.Capacity
comp.Units = 'liter'; % NOT comp.CapacityUnits
comp.Constant = true; % NOT comp.ConstantCapacity

p.Value = 0.1;        % NOT redundant, but never use p.ValueUnits or p.ConstantValue
p.Units = '1/hour';
p.Constant = true;

7. Close Builder and Analyzer before `sbioreset`

sbioreset does NOT close these apps, leaving orphaned windows:

try mb = SimBiology.web.desktophandler.getModelBuilder();
    if ~isempty(mb) && isfield(mb,'webWindow') && isvalid(mb.webWindow), mb.webWindow.close(); end
catch, end
try ma = SimBiology.web.desktophandler.getModelAnalyzer();
    if ~isempty(ma) && isfield(ma,'webWindow') && isvalid(ma.webWindow), ma.webWindow.close(); end
catch, end
pause(1); sbioreset;

8. Diagram rules (only when user requests a diagram)

The following rules apply ONLY when the user asks for a diagram or layout.

Skip all of these for pure model construction.

Model size limit (precondition): Layout helpers bail out above

400 total blocks (species + reactions). For large models, skip

automated layout — use simple grid positioning instead (reactions at

midpoints of connected species).

a. Use addAndPositionCompartment for diagram layout

When building a diagram, use addAndPositionCompartment instead of raw

addcompartment + setBlock — it atomically creates, positions, and

validates each compartment.

% speciesInfo: cell array of structs with .Name, .Value, .Position
speciesInfo = {
    struct('Name', 'Drug', 'Value', 100, 'Position', [40, 30, 50, 16]);
    struct('Name', 'DrugBound', 'Value', 0, 'Position', [140, 30, 100, 16])
};
[comp, sp] = addAndPositionCompartment(model, 'Central', 1, [20, 20, 280, 80], speciesInfo);
% sp is a SimBiology Species ARRAY — index with sp(1), sp(2), NOT sp{1}

b. Diagram build order

  1. Open the Builder first — the diagram does not exist until the Builder

creates it. All simbio.diagram.* calls and addAndPositionCompartment

will fail without this step.

  1. Plan [x y w h] positions for ALL compartments up front (leave 80 px gaps minimum)
  2. Build ONE compartment at a time with addAndPositionCompartment
  3. Add ALL parameters (including rule LHS targets), reactions, rules, doses, events
  4. repositionAllReactions(model) then checkDiagramLayout(model) — fix until zero violations
  5. positionAncillaryBlocks(model) — positions rule/parameter blocks in a grid to the right

c. Leave 80 px gaps between connected compartments

Inter-compartment reaction nodes (15×15) are placed in these gaps by

repositionAllReactions. Without adequate gaps, reaction lines cross

through compartment blocks. For compartments with many shared reactions

(3+), increase to 120 px.

d. Post-placement validation is mandatory

After placing all blocks:

repositionAllReactions(model);
results = checkDiagramLayout(model);
if results.nTotal > 0
    for i = 1:numel(model.Reactions)
        pos = computeSafeReactionPosition(model, model.Reactions(i));
        simbio.diagram.setBlock(model.Reactions(i), 'Position', pos);
    end
    results = checkDiagramLayout(model);
end
positionAncillaryBlocks(model);  % must run LAST, after all objects exist

e. Always use the safe-open pattern for the Builder

Never call simBiologyModelBuilder(model) without first checking

isAppOpen('builder'). If open, close it, wait 2s, then reopen.

if isAppOpen('builder')
    try
        mb = SimBiology.web.desktophandler.getModelBuilder();
        if ~isempty(mb) && isfield(mb, 'webWindow') && isvalid(mb.webWindow)
            mb.webWindow.close();
        end
    catch, end
    pause(2);
end
% If Analyzer is open, it already has a model loaded — open Builder
% without an argument so it picks up the Analyzer's active model.
% Passing a model argument when Analyzer is open can cause conflicts.
if isAppOpen('analyzer')
    simBiologyModelBuilder();
else
    simBiologyModelBuilder(model);
end

f. Never close the Builder to make modifications

The model handle is on sbioroot — all code works on the live model and

updates the diagram in real time. Only close when the user explicitly asks.

Helper Functions (`scripts/`)

Model construction (always available)

| Function | Signature | Purpose |

|----------|-----------|---------|

| getModelByUUID | model = getModelByUUID(uuid) | Look up model by UUID |

Diagram & Builder (only when user requests diagram/layout)

| Function | Signature | Purpose |

|----------|-----------|---------|

| addAndPositionCompartment | [comp,sp] = addAndPositionCompartment(model,name,cap,compPos,speciesInfo,Name=Value) | Create compartment + species and position atomically. sp is a Species array — index with sp(1), NOT sp{1}. Options: FontWeight ("bold"), TextLocation ("center"), Padding (20), AutoExpand (true), AutoFixPositions (true) |

| checkDiagramLayout | results = checkDiagramLayout(model) | Containment + line-through-block + overlap checks |

| computeSafeReactionPosition | pos = computeSafeReactionPosition(model,rxn) | Crossing-free reaction node position |

| repositionAllReactions | nFixed = repositionAllReactions(model) | Batch-reposition all reactions (up to 3 passes) |

| positionAncillaryBlocks | n = positionAncillaryBlocks(model) | Grid-position rule/parameter blocks to the right of compartments |

| openLiveBuilder | openLiveBuilder(model) | Open Builder with safe-open pattern |

| isAppOpen | tf = isAppOpen(appName) | Check if Builder/Analyzer is open |

| loadViaBuilder | model = loadViaBuilder(filePath) | Load .sbproj preserving diagram |

| saveViaBuilder | saveViaBuilder(filePath) | Save from Builder preserving diagram |

| lineIntersectsRect | hit = lineIntersectsRect(x1,y1,x2,y2,rect) | Shared geometry helper (used internally by layout scripts) |

`checkDiagramLayout` output

results.nTotal        % total violations (must be 0 before presenting)
results.nContainment  % species outside parent compartment
results.nLineThrough  % connection lines through unrelated blocks
results.nOverlap      % blocks <10px apart

API Quick Reference

Model

```matlab

proj = sbioloadproject('file.sbproj');

fn = fieldnames(proj);

model = proj.(fn{1});

```

Compartments

Species

Parameters

Reactions

Rules, Events, Doses

or compartment with Constant = false. Create the parameter before the

rule (not after as a fix — this ensures diagram blocks exist for layout):

```matlab

p = addparameter(model, 'RO', 0); p.Constant = false;

addrule(model, 'RO = Complex / (Target + Complex)', 'repeatedAssignment');

```

must have Constant = false (parameters default to true):

```matlab

p = sbioselect(model, 'Type', 'parameter', 'Name', 'kgrow');

p.Constant = false;

addevent(model, 'Tumor.Cancer < 1e6', {'kgrow = kgrow * 0.5'});

```

Observables & Variants

Simulation Config

Selection

Core Patterns

Model creation (standard — no diagram)

model = sbiomodel('MyModel');
disp(model.uuid)
comp = addcompartment(model, 'Central', 1);
addspecies(comp, 'Drug', 100);
addparameter(model, 'ke', 0.1);

Reactions

% MassAction (always use qualified species names)
rx = addreaction(model, 'Central.Drug -> null');
kl = addkineticlaw(rx, 'MassAction');
kl.ParameterVariableNames = {'ke'};

% Custom rate
rx = addreaction(model, 'Central.E + Central.S <-> Central.ES');
rx.ReactionRate = 'kf*Central.E*Central.S - kr*Central.ES';

% Multi-compartment transfer
rx = addreaction(model, 'Central.Drug -> Peripheral.Drug');

% Species with invalid MATLAB variable names
rx = addreaction(model, 'Central.[Drug-bound] -> Central.[Drug-free]');

Removing components

delete(sbioselect(model, 'Type', 'species', 'Name', 'Drug'));
delete(sbioselect(model, 'Type', 'reaction', 'Reaction', 'Drug -> null'));
removedose(model, model.Doses(1));  % doses use removedose, not delete

Doses

% Bolus
d = sbiodose('Dose', 'schedule');
d.TargetName = 'Drug'; d.Amount = 100; d.Time = 0;
adddose(model, d);

% Repeat dose
d = sbiodose('RepeatDose', 'repeat');
d.TargetName = 'Drug'; d.Amount = 50;
d.StartTime = 0; d.Interval = 8; d.RepeatCount = 3;
adddose(model, d);

Events, variants, observables

% Event modifying a parameter — mark non-constant first
p = sbioselect(model, 'Type', 'parameter', 'Name', 'ke');
p.Constant = false;
ev = addevent(model, 'time >= 10', {'ke = ke * 2'}); ev.Name = 'EnzymeInduction';

% Event modifying a species (species default Constant=false — no extra step)
ev = addevent(model, 'time >= 10', {'Drug = 50'}); ev.Name = 'RescueDose';

v = addvariant(model, 'HighDose'); addcontent(v, {'parameter','ke','Value',0.5});
obs = addobservable(model, 'DrugConc', 'Drug ./ Central');

Saving Models

Do NOT use sbiosaveproject (deprecated, requires base workspace hacks).

Diagram Basics (only when user requests diagram/layout)

Coordinate system

Position = [x y width height] where (x, y) is top-left corner.

Standard block sizes

| Block Type | Default Size | Notes |

|------------|--------------|-------|

| Species | [50, 16] | Scale width: <=5 chars → 50, 6-12 → 100, 13+ → 130 |

| Reaction | [15, 15] | |

| Rule | [20, 20] | |

Compartment sizing from content

| Species Count | Size | Notes |

|---------------|------|-------|

| 1 | 160 x 100 | Single species, centered |

| 2 (isolated) | 240 x 170 | Vertically stacked |

| 2 (in chain) | 400 x 100 | Side by side |

| 3-5 | 160+n*50 x 100+n*35 | Scale to content |

| 6+ | 240+n*50 x 220+n*35 | Row layout, multiple rows if needed |

Internal padding: 30 px minimum on all sides.

Row-based species placement (3+ species)

Distribute species evenly in a horizontal row at y + height/2 - 8, with

40 px margin from compartment edges. Scale species width by name length:

<=5 chars → 50, 6-12 → 100, 13+ → 130.

Species ordering by connection direction

When a compartment has 2+ species that connect to different external

compartments, order them so each species faces its connections. This

prevents connection lines from crossing through sibling species.

edge, species connecting RIGHT on the right edge.

species connecting DOWN/RIGHT on bottom.

Lymphocyte (connects upper-left to Spleen). Put Lymphocyte on top and

Neutrophil on bottom so lines don't cross.

Layout rules

Hard requirements:

  1. No block overlap (except species inside compartments)
  2. Labels visible — not overlapping other blocks
  3. Horizontal/vertical alignment for same-tier compartments
  4. Inter-compartment reactions outside both compartments (in the gap)
  5. No connection lines through unrelated blocks
  6. 50 px minimum reaction-to-species distance

Preferred placement:

  1. Elimination/degradation reactions inside their parent compartment (communicates the process occurs locally, not across a boundary)

Flow direction by model type

| Model Type | Flow Direction |

|------------|----------------|

| PKPD | PD upper-left, PK lower-right |

| Metabolic | Top-to-bottom |

| PBPK | Circulation-based columns |

| Simple PK | Left-to-right or diagonal |

References

Load on demand for detailed guidance:


Copyright 2026 The MathWorks, Inc.


Use this skill with your AI agent: Open on Skill Issue to copy, download, or add to your library. Works with Claude, ChatGPT, Gemini, Cursor, Windsurf and more.