Zynq bringup is an AI agent skill from the GitHub repository LNC0831/oh-my-fpga. Stand up a Zynq-7000 PS7-based SoC block design (Processing System bring-up). Invoke when the user says "build a zynq soc", "ps7", "zynq bring up", "add a processing system", "PS-PL design", "bring up the ARM cores", "wire AXI GP/HP to the PL", "generate the bd wrapper for a Zynq", or asks to create

How to use this skill

Skill file

Zynq-7000 (PS7) Bring-Up

A methodology playbook for standing up a Zynq-7000 SoC: create a block design,

instantiate and configure the PS7 Processing System, wire PS↔PL AXI fabric with

clean clock/reset, assign and verify the address map, validate, generate the

HDL wrapper, then prove it through synthesis/implementation/DRC. This is a

build-and-verify flow, not a fix-it flow — but the rigor is the same:

every "it works" claim is backed by fresh tool output, never by assumption.

The PS7 is a hard ARM Cortex-A9 block. You do not write RTL for it — you

configure it (FCLKs, DDR, MIO peripherals, PS-PL AXI ports) and wire the PL

side to it correctly. Most bring-up failures are wiring/clocking/address errors,

not logic errors, so this skill measures the graph state at each step.

A critical fact that shapes the whole flow: **many wrong-but-plausible mistakes

pass bd_validate_design and even synthesis, and surface only at

post-implementation report_drc / check_timing / report_cdc** (wrong DDR

part, polarity-mismatched reset, unconstrained PL-side IO, missing CDC

constraints). The graph being "valid" is therefore never sign-off — only fresh

post-implementation evidence is.


When to use

controller, custom AXI IP) off M_AXI_GP0, or feed a PL master into S_AXI_HP0.

through synth/impl/bitstream as a sanity sign-off.

When NOT to use

skill and bd_create_mpsoc / bd_apply_mpsoc_preset family — PS7 tools do not

apply.

project + synthesis/timing skills.

skill. (This skill checks timing as sign-off, it does not close it.)

the embedded (emb_*) flow; this skill stops at hardware handoff (XSA).

flow; verify PL logic standalone with the simulation skill.


Prerequisites (verify first)

Do not start building blind. Confirm the environment and the part with tools:

  1. test_connection — confirm the Tcl bridge to Vivado is live. If it fails,

STOP and tell the user to open Vivado and start tcl_server.tcl. Nothing

below works without this.

  1. get_license_status — required precondition. Block Design (bd_*) tools

are PRO/MAX tier. If the license is FREE, the bd_* calls below are blocked;

surface this now and stop, rather than failing opaquely mid-flow.

  1. get_project_info — is a project open, and what is the target part?

or a Zynq board part. If the part is not Zynq-7000, STOP and ask the

user — PS7 will not instantiate on a non-Zynq part, and silently guessing a

part is a destructive surprise.

Ask for the exact part or board before creating one; never invent it.

  1. list_block_designs — is there already a BD? Reuse it (open_block_design)

rather than creating a duplicate; only create_block_design if none exists or

the user wants a fresh one.

Record the part, board (if any), and target FCLK frequency before

proceeding — these drive every later decision (DDR config, MIO, automation).


Board-aware vs. board-agnostic: the first decision

The single most important branch in PS7 bring-up is whether a board part is

set on the project. It changes how DDR/MIO get configured and whether you can

trust automation.

| Condition (from get_project_info) | DDR + MIO strategy | Automation | Risk |

|---|---|---|---|

| Board part set (e.g. Zedboard, Cora, Pynq) | bd_create_ps7(run_automation=True) — this runs Vivado's PS block automation (the underlying apply_bd_automation Tcl command, invoked for you by the MCP tool; do not call apply_bd_automation directly — it is not an MCP tool), filling DDR part, MIO pinout and FIXED_IO from the board file | Trust bd_run_block_automation for the PS | Low — board file is authoritative |

| Bare part only (xc7z…, no board) | bd_create_ps7(run_automation=False), then inspect with bd_get_ps7_config and explicitly set DDR part / bus width / MIO via bd_configure_ps7. DDR config MUST match the physical board's memory or hardware will not boot | Do NOT trust block automation for DDR/MIO — it has no board data | High — wrong DDR = dead board. Ask the user for the DDR part / board if unknown |

Tool-name note: bd_create_ps7(run_automation=True) and

bd_run_block_automation are the MCP tools. apply_bd_automation /

run_bd_automation are native Vivado Tcl commands those tools wrap — never

call them as if they were MCP tools.

Bare-part DDR safety rail (read this). On a bare part, do not invent DDR

timing/part numbers to make validation pass. Be explicit that the tooling will

not catch a wrong DDR part for you:

- bd_validate_design will pass with a wrong-but-plausible DDR part.

- Synthesis will pass — the DDR/FIXED_IO are hard-pinned PS pins, not logic.

- bd_get_ps7_config readback only confirms the value you wrote, not that it

matches the physical board — it cannot detect a wrong DDR part.

- The only automated gate that catches a missing/wrong DDR + FIXED_IO

pinout is post-implementation report_drc (UCIO / FIXED_IO / DDR no-pin

errors). Therefore, whenever you configure DDR on a bare part, the §13

post-impl report_drc gate is mandatory and is the decision's

verification — never skip it.

If the DDR part is unknown, state the assumption explicitly and ask the user

before configuring it.


METHODOLOGY

One change-class per step, then measure before moving on. The recurring

verbs are: *configure → inspect (bd_get_* / bd_list_*) → connect →

re-inspect (bd_get_unconnected_pins) → validate*.

1. Open or create the block design

2. Instantiate the PS7

hp_slave, multi_clock).

via the wrapped block automation).

MIO/peripheral I/O, interrupts, PS-PL interfaces). This is your ground truth

for what was written — but remember it does not prove DDR matches the

board (see safety rail). Do not assume the preset did what its name implies;

confirm it here.

3. Configure DDR and MIO (bare-part path only)

Skip if board automation already populated DDR/FIXED_IO (verify via

bd_get_ps7_config that DDR is configured before skipping).

DDR part, bus width, and any MIO peripheral pinout the design needs.

read-only or silently ignored, you will see it here — surface it, don't paper

over it.

verdict for the DDR/FIXED_IO config is the mandatory post-impl report_drc

gate in §13. Do not declare DDR "done" until that gate is clean.

4. Set the PL clock(s) — FCLK

The PS provides the PL clock; get this right before wiring anything.

the primary PL clock. Add more FCLKs only if the design needs multiple clock

domains.

requested frequency. The requested vs. actually-realizable frequency can

differ (PLL granularity); note the actual value — it is your real timing

constraint later.

intrinsic clock-domain boundary. Flag it now — it forces the CDC checks in §13

and may require an axi_clock_converter (see step 7/8 and Safety rails).

5. Enable the PS-PL AXI port(s) you actually need

Only enable ports the design uses; spurious ports create unconnected-pin noise.

bd_ps7_enable_axi_port(cell="ps7_0", ...) for M_AXI_GP0

(or use the minimal preset which already exposes M_AXI_GP0).

S_AXI_HP0 (or the hp_slave preset).

6. Add PL-side peripherals (only what the user asked for)

Examples (use the exact tool; bd_search_ip / ToolSearch to confirm a specific

IP's tool name if unsure):

7. Wire clocks and resets correctly (the #1 source of bring-up bugs)

The PS does NOT provide a synchronized PL reset by itself — you need a

Processor System Reset block driven by FCLK0 and the PS reset.

validates clean and passes DRC but breaks function on silicon (peripherals held

in reset, or never reset). Call bd_proc_sys_reset_get_config(...) and confirm:

downstream AXI IP's s_axi_aresetn expects (AXI uses active-low reset). No action

needed if you drive AXI resets from it.

(C_EXT_RESET_HIGH) is fixed at IP creation and read-only — in the standard

PS7/board-automation flow it is already correct. bd_proc_sys_reset_set_polarity

does not change ext_reset_in; it only sets the auxiliary reset

(aux_reset_active_low, used only if you wire aux_reset_in). If ext_reset_in

polarity is genuinely wrong, recreate the proc_sys_reset block with the right

setting — do not wire-and-hope.

s_axi_aclk and the interconnect/smartconnect clocks

(bd_connect_pins / bd_connect_interfaces).

interconnect reset.

master driving it (unless you deliberately insert an axi_clock_converter for a

CDC — see Safety rails). Mixing FCLK0 and FCLK1 across a single AXI link without

a converter is a silent functional bug.

8. Build the AXI fabric and connect master → slaves

(auto width/clock conversion, preferred for new designs) or

bd_create_axi_interconnect.

port to a peripheral's S_AXI:

bd_connect_interfaces(src="ps7_0/M_AXI_GP0", dst="<sc>/S00_AXI"),

then <sc>/M0x_AXI → <periph>/S_AXI.

for the PS itself, and/or bd_run_automation to auto-connect AXI/clk/reset for

a peripheral. If you use automation, still run step 9 — automation can

mis-guess clock domains.

9. Verify connectivity BEFORE address assignment

documented reason to leave open, e.g. an intentionally-external interrupt). If

it lists clock/reset/AXI pins, go back to step 7/8. **Do not proceed with

dangling AXI clocks/resets** — they produce a design that validates the graph

but is functionally broken.

10. Assign and verify the address map

range inside the PS GP address window.

silently broken software access later. If anything looks wrong, fix and

re-assign; do not hand off a questionable map.

11. Validate the block design

pin/net path). Treat any ERROR as a hard stop; fix the specific net/pin it

names, then re-validate. Warnings: read each one — distinguish benign

(e.g. board-flow info) from real (unconnected interface, clock mismatch).

polarity correctness, PL-side IO constraints, CDC, or timing. Those are §13.

12. Generate output products + HDL wrapper, set top (long op — bounded poll)

top-level HDL wrapper.

this is multi-minute. Poll bd_check_output_status (and/or

bd_wait_on_output_generation) with an explicit ceiling: pick a sane wall-

clock budget (e.g. 15 min) and a max poll count; if generation has not

completed by then, STOP and report it as a stalled long-op rather than looping

forever. Do not assume success; confirm status is complete before proceeding.

list_source_files: the active top in the synthesis fileset must equal the

generated wrapper module. If the fileset top is still an old/placeholder

module, synthesis will build the wrong thing. Do not start synthesis until

this is confirmed.

is not buildable as-is; surface it (an upgrade_ip may be needed) rather than

proceeding.

13. Hardware sign-off (necessary — graph-clean is not enough)

A valid BD that won't implement is not a bring-up. Prove it with **fresh,

post-implementation evidence. Synthesis success is necessary, not

sufficient** — it proves neither timing, nor routability, nor pin legality.

13a. Constrain PL-side IO before trusting timing. Any PL-side top-level port

made external in the BD (e.g. a UART/GPIO pin, a PL clock/reset, an LED) is an

unconstrained endpoint until you constrain it. Unconstrained IO produces an

optimistic / false WNS ≥ 0. Where the design has PL-side IO:

relevant clock, and

create_io_constraint).

The PS DDR/FIXED_IO pins are handled by the PS (do not constrain those by hand);

this step is about the PL ports.

13b. Run the flow (bounded async poll).

/ timeout ceiling** (same bounded-poll rule as §12 — a poll loop with no

ceiling can hang). On completion: check_synthesis_issues +

get_synthesis_warnings.

done.

13c. Sign-off evidence — ALL must be fresh and post-implementation:

unconstrained endpoints / no-clock / missing input-output-delay problems. A

clean report_timing_summary WNS is meaningless if check_timing shows

unconstrained paths producing a false positive. There must be **no

unconstrained-endpoint / no-clock issues** here.

Reporting setup-only is not "timing met". A design can have setup slack and

still fail hold. If either setup or hold is negative, hand off to the

timing-closure skill; do not claim "works".

report_cdc (and, pre-synth, check_cdc_lint). The PS-PL boundary is an

intrinsic clock crossing; multiple FCLKs add more. There must be **no unsafe

/ missing-constraint CDC paths**. report_methodology alone does NOT catch

every missing CDC constraint — report_cdc is the dedicated check and is

required here.

for the bare-part DDR/FIXED_IO decision** (UCIO / FIXED_IO / DDR no-pin

errors): if you configured DDR on a bare part, this gate is what proves the

pinout is real. It is non-optional.

additional clock/CDC/structural issues; complements, does not replace,

report_cdc).

(clean), report_drc (clean), report_methodology (clean)** all pass on fresh

post-impl runs may you say the SoC is brought up.

14. (Optional) Bitstream + hardware export

but still verify §13 reports afterward; run_full_flow does not exempt you from

evidence).


Connectivity decision table (symptom → cause → safe fix)

| Symptom (from a tool) | Likely cause | Smallest safe fix |

|---|---|---|

| bd_validate_design ERROR naming an AXI s_axi_aclk pin | AXI clock unconnected or wrong FCLK domain | Connect that pin to the correct FCLK in step 7; re-validate. |

| bd_get_unconnected_pins lists *aresetn | Missing proc_sys_reset wiring | Add/connect bd_create_proc_sys_reset outputs (step 7). |

| Peripheral held in reset / never resets, but graph validates clean | proc_sys_reset wiring/polarity | bd_proc_sys_reset_get_config: confirm ext_reset_in is fed by active-low FCLK_RESET0_N (its polarity is fixed at creation — recreate the block if wrong) and peripheral_aresetn (active-low by design) drives the AXI resets. set_polarity only changes the aux reset (step 7). |

| bd_get_address_map shows a slave with no range | Slave not reachable from the PS master / not assigned | Confirm master→slave interface path (step 8), re-run bd_assign_addresses. |

| Address ranges overlap | Manual/partial assignment | Re-run bd_assign_addresses; if still overlapping, inspect and set non-overlapping ranges; never ship an overlap. |

| check_timing shows unconstrained endpoints / no-clock | PL-side IO has no input/output delay or no clock | Add set_input_delay/set_output_delay + IO constraints (§13a); re-run. A WNS taken before this is false. |

| FCLK realized freq ≠ requested | PLL granularity | Accept the realized value and use it as the timing constraint; note it to the user. Do not over-constrain a clock the PS cannot produce. |

| report_timing_summary setup WNS ≥ 0 but hold (WHS) < 0 | Hold violation (short paths / clock skew) | This is a real failure, not "timing met" — hand off to timing-closure; do not report success. |

| report_timing_summary WNS < 0 on a PS-PL AXI path | PL too slow for FCLK, or a true CDC across FCLK domains | First confirm it's a real same-domain path (run report_clock_interaction / report_cdc). If real same-domain → timing-closure skill. If genuinely async across two FCLKs (proven by report_clock_interaction / report_cdc) → insert bd_create_axi_clock_converter (a real CDC fix), not a blanket set_false_path. |

| report_cdc flags an unsafe/unconstrained crossing | PS-PL or multi-FCLK crossing without synchronizer/constraint | Add the correct CDC structure (axi_clock_converter for AXI, proper synchronizer for single bits) — never paper over with set_false_path unprovenly. |

| report_ip_status shows a locked IP | Version mismatch | upgrade_ip / regenerate output products; re-validate. Surface to user if it changes behavior. |

| report_drc UCIO/no-pin errors on FIXED_IO/DDR | DDR/FIXED_IO not exported (bare-part path) or board automation skipped | Run PS bd_run_block_automation / configure DDR+FIXED_IO (steps 2–3); these are hard-pinned by the PS and must be present. This DRC IS the bare-part DDR gate. |

| Synthesis built the wrong/old top | Wrapper not actually set as top in fileset | set_top_module(<wrapper>), then confirm via get_project_info/list_source_files (§12) before re-synth. |


Build → verify → re-measure loop (with STOP conditions)

Each step's bd_get_* / report_* is the "measure". Iterate only the failing

sub-step, change one class of thing, then re-measure. STOP and act when:

check_timing clean (no unconstrained endpoints), report_timing_summary

setup WNS/TNS ≥ 0 and hold/min-delay ≥ 0, report_cdc clean, report_drc

clean, and report_methodology clean → declare bring-up complete with the

metrics shown.

part → stop and ask the user. Do not guess hardware-critical config.

that might be a genuine bug (real same-domain path failing, real CDC) → present

it and ask before waiving. Never set_false_path / set_multicycle_path /

waive_lint_violation a path that could be real just to turn a number green.

clocks defined, check_timing clean) → this is the timing-closure skill's job;

hand off with the report, don't thrash on RTL here.

PS-PL bandwidth shortfall needing HP-port/architecture change) → present

options + costs (e.g. "add S_AXI_HP for DMA bandwidth vs. lower FCLK vs. smaller

part") and hand back to the human. Do not loop.

implementation) exceeds its poll ceiling / wall-clock budget → stop the poll

loop and report it as stalled, rather than polling forever.

distinct fix attempts, STOP and present what you tried + what's left. Don't keep

poking.


Safety rails (do not violate)

"no CDC issues", "bitstream generated" each require fresh output from the

corresponding tool (bd_validate_design, bd_get_address_map, post-impl

check_timing + report_timing_summary, report_cdc, generate_bitstream).

Never infer success from a prior step or from a tool running without error.

Synthesis numbers never substitute for post-implementation sign-off.

hold (WHS/THS) ≥ 0, and only after check_timing shows no unconstrained

endpoints. Setup-only is not sign-off.

(and pre-synth check_cdc_lint) is required; report_methodology does not

replace it.

Do not apply set_false_path / set_multicycle_path / set_clock_groups /

waive_lint_violation to silence a violation that could be real. A true

asynchronous PS-PL crossing (different FCLKs, or PS clock vs. a separately-

generated PL clock) is the only place an exception is legitimate — and you

must prove it is genuinely asynchronous with fresh report_clock_interaction

and/or report_cdc evidence showing the two clocks have no timed relationship,

before applying set_clock_groups -asynchronous or inserting

bd_create_axi_clock_converter. A self-declared "assume it's async" is not

acceptable. If the evidence is unclear, ask first.

validation pass on a bare part. Wrong DDR/MIO passes bd_validate_design,

bd_get_ps7_config readback, AND synthesis — it is caught only by

post-impl report_drc (UCIO/FIXED_IO/DDR no-pin). State the assumption and ask

the user for the board/DDR if unknown; treat the §13 report_drc gate as the

decision's verification.

passes DRC but breaks silicon. Use bd_proc_sys_reset_get_config before connecting

aresetn: peripheral_aresetn is active-low by design; ext_reset_in polarity is

fixed at creation (recreate the block if wrong — set_polarity only affects the aux

reset). See step 7.

get_project_info / list_source_files before synthesis (step 12).

(FCLK, reset, interconnect, address) over editing or generating RTL. The PS7 is

hard IP — you configure it, you do not rewrite it. For PL-side RTL issues,

recommend the edit; do not silently rewrite user RTL.

resets, then fabric, then addresses — not all at once).

generate before build.** Skipping the bd_get_unconnected_pins check produces

designs that validate but are functionally dead.

non-Zynq, stop — do not force it.

implementation are multi-minute: use bd_wait_on_output_generation /

bd_check_output_status / *_async + get_run_status, **each with an explicit

poll-count / wall-clock ceiling** so the poll loop cannot hang indefinitely.

Confirm completion before the next stage.


Output (report back to the user)

Report, with the tool output backing each line:

  1. Configuration realized — part/board, BD name, PS7 instance, FCLK(s) at

their actual realized frequency (from bd_get_ps7_config), DDR status,

reset polarity confirmed (bd_proc_sys_reset_get_config), enabled PS-PL ports,

PL peripherals added.

  1. Connectivity — bd_get_unconnected_pins result (empty, or the documented

exceptions).

  1. Address map — the bd_get_address_map table (slave → base/range), noted as

non-overlapping.

  1. Validation — bd_validate_design result verbatim (clean / the errors).
  2. Top confirmed — wrapper module set as top and verified in the fileset

(get_project_info / list_source_files).

  1. Sign-off evidence (fresh, post-implementation) — check_timing (no

unconstrained endpoints), report_timing_summary **setup WNS/TNS AND hold

(WHS/THS) ≥ 0**, report_cdc (clean / flagged crossings), report_drc

(clean — explicitly note this is the DDR/FIXED_IO gate on a bare part),

report_methodology, report_utilization. If any failed, say so plainly and

route to the right next step (timing-closure / user decision) — do not

report a partial build as a success. Never report setup-only timing as "met".

  1. Artifacts — wrapper module set as top, bitstream (if generated), XSA path

(if export_hardware was run).

  1. Open items / trade-offs — anything that needs a human decision (DDR config

to confirm, timing shortfall, bandwidth trade-off), stated explicitly.

If a STOP-ASK or STOP-TRADEOFF condition was hit, the output is the question or

the options table — not a claim of completion.

Use this skill with your AI agent: Open on Skill Issue to copy, download, or add to your library. Works with Claude, ChatGPT, Gemini, Cursor, Windsurf and more.