Tooluniverse pharmacokinetics

From mims-harvard/ToolUniverse · View interactive version

Tooluniverse pharmacokinetics is an AI agent skill from the GitHub repository mims-harvard/ToolUniverse. Pharmacokinetic (PK) analysis of concentration-time data — non-compartmental analysis (NCA) for Cmax, Tmax, AUC (0-t and 0-∞), terminal half-life, clearance (CL), volume of distribution (Vd), MRT, and absolute bioavailability (F). Also one-compartment fitting. Use when you have plasma/serum drug con

How to use this skill

Skill file

Pharmacokinetic (PK) Analysis — Non-Compartmental Analysis

Turn a concentration-vs-time profile after a dose into the standard PK parameters, and compute bioavailability from IV + oral data. Non-compartmental analysis (NCA) is the model-independent workhorse used for most PK reporting.

When to use this

This is measured-data PK. For predicting ADMET properties from a chemical structure, use tooluniverse-admet-prediction.

Step 1 — Prepare the concentration-time data

| Issue | What to do |

|---|---|

| Units — be consistent | One time unit (h), one concentration unit (mg/L or ng/mL), one dose unit (mg). Pass them as time_unit/conc_unit/dose_unit. CL and Vd come back in derived units (e.g. L/h, L). |

| Route matters | Set route to iv or po/oral. CL and Vd are only directly interpretable for IV data; from oral data they are apparent (CL/F, Vd/F) because absorption is incomplete. |

| Include t=0 | For IV bolus include the t=0 (back-extrapolated) point; for oral the pre-dose value is usually 0. |

| BLQ (below limit of quantification) | Leading BLQs before the first measurable → treat as 0; BLQs in the terminal tail → drop them (don't set to 0, it corrupts the terminal slope). |

| Sampling design | You need enough late points to define the terminal phase (≥3 points clearly in the log-linear decline) or the half-life and AUC0-∞ are unreliable. |

| Single vs multiple dose | NCA here assumes a single dose. For steady-state, analyze one dosing interval (AUC0-τ) and say so. |

Step 2 — Run NCA

tu run NCA_compute_parameters '{
  "times":[0,0.5,1,2,4,8,12,24],
  "concentrations":[0,2.5,4.8,6.1,4.2,2.1,1.0,0.2],
  "dose":100, "route":"iv",
  "dose_unit":"mg", "conc_unit":"mg/L", "time_unit":"h"}'

Returns Cmax, Tmax, Clast, Tlast, AUC0_last, AUC0-inf, AUC_extrapolation_pct, lambda_z, t_half, r_squared_terminal_fit, clearance_CL, volume_distribution_Vd, MRT_iv, with a units block. AUC uses the FDA/EMA linear-up / log-down trapezoidal method.

For a CSV profile (with BLQ handling), scripts/nca_from_csv.py computes the same parameters locally.

Other tools:

Step 3 — Interpret the parameters

| Parameter | Meaning | Notes / sanity |

|---|---|---|

| Cmax / Tmax | Peak concentration & time to peak — absorption rate/extent. | For IV bolus Cmax is at t=0; a later Tmax means absorption (oral) or distribution. |

| AUC0-t / AUC0-∞ | Total exposure (area under the curve). The key exposure metric. | AUC0-∞ extrapolates the tail using Clast/lambda_z. |

| AUC_extrapolation_pct | % of AUC0-∞ that was extrapolated beyond the last point. | >20% → AUC0-∞ (and anything derived from it) is unreliable; report AUC0-last instead and note insufficient sampling. |

| lambda_z / t_half | Terminal elimination rate constant and half-life. | Trust only if r_squared_terminal_fit ≥ ~0.95 and ≥3 terminal points were used. |

| CL (clearance) | Volume cleared per time = Dose/AUC0-∞ (IV). | From oral data this is CL/F (apparent). |

| Vd | Volume of distribution = CL/lambda_z (IV). | From oral data this is Vd/F (apparent). |

| MRT | Mean residence time. | Longer MRT = slower overall elimination. |

Step 4 — Absolute bioavailability (F)

F needs the same drug given both IV and orally (ideally same subjects, dose-normalized):

tu run NCA_calculate_bioavailability '{"auc_po":35.0,"dose_po":200,"auc_iv":43.4,"dose_iv":100}'

F = (AUC_po / Dose_po) / (AUC_iv / Dose_iv). Report as a fraction or %. F near 1 = well absorbed; low F = poor absorption or high first-pass metabolism. F > 1 signals a data/dosing error (recheck units and doses).

Step 5 — Quality gotchas (state these)

Honest limitations

Related skills

Use this skill with your AI agent: Open on Skill Issue to copy, download, or add to your library. Works with Claude, ChatGPT, Gemini, Cursor, Windsurf and more.