Fleet

From nebius/nebius-physical-ai · View interactive version

Fleet is an AI agent skill from the GitHub repository nebius/nebius-physical-ai. Use to deploy or operate a fleet of Nebius Managed Kubernetes (k8s-training) clusters across one or many projects in a tenant from an npa.fleet/v0.0.1 spec — including strict capacity-block-backed GPU pools, identical and/or custom clusters, create-on-demand projects, and a k8s-training recipe sourc

How to use this skill

Skill file

Fleet (multi-cluster, multi-project Kubernetes)

When To Use

Use when a customer wants more than one Managed Kubernetes cluster stood up

across one or many projects in a single Nebius tenant — e.g. per-team or

per-tenant training clusters — and wants npa to drive it from one declarative

file. npa fleet wraps the public nebius/nebius-solutions-library

k8s-training recipe (the same recipe npa cluster up uses) once per cluster,

and can create the target projects on demand.

For a single cluster, prefer npa cluster up. For Slurm-on-Kubernetes, use

npa soperator.

Three-tier contract:

--spec <fleet.yaml>`.

FleetSpec / ProjectSpec / ClusterSpec / NodePoolSpec.

toolRef: infra.fleet.deploy (config key fleet_spec).

Opt-in CPU RayCluster

Use `kuberay: {enabled: true, worker_replicas: 2, worker_cpus: 2,

worker_memory_gib: 4}` in a cluster/default profile for a fixed CPU worker group.

The shared backend validates strict types, explicit CPU placement and the exact

reviewed recipe before provisioning. It also rejects head or worker pods larger

than one declared CPU node and fixed requests above the pool's nominal aggregate

CPU or memory; operators must still leave room for Kubernetes system pods.

KubeRaySpec is exported by npa.sdk.fleet.

A disabled block replaces enabled defaults atomically. Omitted policy remains off.

Enabled deployments require the default local Terraform workspace without

TF_CLI_ARGS* or TF_DATA_DIR overrides. Reapply rejects extra effective inputs

and destination symlinks while preserving exact state/backup and provider caches.

Retained backend metadata is unsupported; require managed implicit local state.

The module manifest is rebuilt from the reviewed recipe before Terraform init.

Historical opt-in provenance survives disabled/omitted policy reapply. Teardown

checks the same effective-input restrictions and recorded materialized digest,

then requires empty managed state before removing recovery files. Preserve state

on refusal or incomplete teardown; missing provenance needs a reviewed reapply.

See docs/fleet-kuberay.md and

npa/examples/fleet/kuberay/cpu-raycluster.yaml for the one-entry fleet and native

Ray Jobs journey. The separate CPU template pins Ray 2.58, disables autoscaling

and bundled monitoring, uses non-root pods and installs namespace ingress

isolation. GPU workers, RayService, arbitrary images and alternate recipe bytes

are unsupported; do not recreate a Jobs submitter/controller or enable the old

privileged vendor template. Preserve application outputs before owned teardown.

Run npa/tests/e2e/test_fleet_kuberay_live.py with

NPA_FLEET_KUBERAY_LIVE_CONFIG pointing at an owner-private JSON object with

spec, kubeconfig, and evidence_dir. It inspects deployed values and executes

real deterministic work on every Ray worker through native Jobs status/logs.

Verify an existing shared filesystem

Run npa fleet verify-storage --spec <private-fleet.yaml> --output json to

qualify every CPU and GPU worker. The shared implementation is

npa.fleet.storage_verification.verify_storage, also exported as

npa.sdk.fleet.verify_storage. Use --only-projects, --only-clusters,

--project-prefix, and --profile to preserve Fleet selection and identity

semantics. Unknown selectors and missing or stale registered identity fail

closed; explicitly disabled filesystems are skipped.

The verifier proves the exact read-write virtiofs source/path, reboot-safe

nofail entry, capacity in binary GiB, unique host-file checksums, CSI health,

and one RWX PVC shared across pods pinned to every exact worker. Every pod

checks every worker's unique payload. It reads no pre-existing customer entries.

Cleanup removes only owned probe paths and temporary resources with identity

labels and UID preconditions, then proves absence on every node using

server-synchronized Linux statx attributes after owned writers stop. Cached

positive directory entries cannot substitute for fresh link-count evidence;

unsupported synchronization and persistent linked entries fail closed.

Partial evidence or cleanup failure cannot pass. Do not replace this with the vendored single-node shell

smoke or infer storage health from node readiness.

Use --evidence-dir <owner-private-directory> outside the repository for exact

receipts. Publication surfaces receive only sanitized counts, requested capacity,

categories, hashes, and cleanup counts. This operation does not redeploy,

resize, change IAM, or alter customer workloads. See

docs/fleet-storage-verification.md for prerequisites and the installed SDK.

Run npa fleet verify-graphics --spec <private-fleet.yaml> --output json after

an RTX driver, node, or runtime change. It uses the registered Fleet identity,

waits for the declared health stability interval, and runs CUDA vectorAdd plus

GLX, EGL, and Vulkan qualification on every selected positive-GPU RTX worker.

The documented default one-GPU and explicit eight-GPU PCIe shapes are both

supported, while NVSwitch restrictions remain topology-specific. All

targets must declare gpu_workload_profile: rtx-rendering; a partial target or

partial per-node result fails closed. Use --concurrency for independent

clusters and the standard Fleet selectors to narrow scope. Exact provider and

node evidence goes only to the owner-private --evidence-dir outside Git; CLI

output remains safe to publish. The shared SDK entry point is

npa.sdk.fleet.verify_graphics.

Recover one interrupted apply without changing Terraform state

Use `npa fleet recover --spec <private-fleet.yaml> --only-projects <project>

--only-clusters <cluster> --yes --output json` only after an interrupted MK8s

apply has left its exact target running. The operation accepts exactly one

declared target. Before it writes an ordinary Fleet/context registration, it

requires the persisted backend owner marker, provisioning sidecar, immutable

recipe-release record, rendered Terraform inputs, and local state identity to

agree with the selected spec. It also refuses a live local Terraform apply and

provider/plugin child or target state-lock holder, then freshly verifies the

exact provider project, terminal cluster, and requested node topology.

Recovery never runs Terraform, force-unlocks it, edits its state, creates a

replacement target, or deletes any resource. A stale Terraform lock is retained

unchanged. A successful result is recovered-pending-validation: run the

ordinary ownership-controlled storage, graphics, and workload gates before

calling the target ready. Programmatic callers can use

npa.sdk.fleet.recover_interrupted_apply with the same exact selectors.

The all-worker live regression is

npa/tests/e2e/test_fleet_storage_verification_live.py. Supply

NPA_INTEGRATION_E2E=1, NPA_FLEET_STORAGE_VERIFY=1, an owner-private

NPA_FLEET_STORAGE_VERIFY_SPEC, and NPA_FLEET_STORAGE_EVIDENCE_DIR.

The daily runner reaches it only with that explicit opt-in. Its expected target,

worker, and binary-GiB totals derive from the complete selected declaration.

RTX PRO 6000 hardware MIG is an additive cluster policy. Use `mig: {enabled:

true, strategy: mixed, config: all-balanced}` only with two strict

reserved-capacity gpu-rtx6000 / 1gpu-24vcpu-218gb workers and 128 GiB boot

disks. NPA pins and live-verifies GPU Operator v26.3.3, driver 580.173.02,

device plugin/GFD v0.19.3, MIG Manager v0.14.2, exact per-node resources,

and zero whole-GPU capacity/allocatable. See

docs/fleet-rtx-pro-6000-mig.md and npa/examples/fleet/rtxpro-mig.yaml.

RTX rendering without MIG uses the separate explicit cluster settings:

gpu_workload_profile: rtx-rendering
gpu_graphics_smoke_image: '<reviewed-registry>/graphics@sha256:<64-hex-digest>'

The graphics image is a reviewed operator-supplied immutable digest. The

governed tool://sonic default is quarantined, so omitting this field makes the

graphics gate refuse before deployment rather than selecting an implicit image.

See docs/workbench/mk8s-gpu-driver-strategy.md for the direct CLI, SDK, and

standalone-RTX forms. The profile selects RTX PRO 6000 (including an explicitly

resolved zonal platform such as gpu-rtx6000-a), the supported single-GPU preset

by default or accepts the explicit

8gpu-192vcpu-1744gb RTX PCIe preset, uses GPU Operator mounted drivers, and

requires per-node GLX/EGL/Vulkan readiness. The 8-GPU RTX shape remains

non-fabric and does not opt into the NVSwitch unsafe-operator path. The profile

does not alter the empty/default managed-image contract and cannot be

generalized to NVSwitch targets.

The rendering profile supplies the exact platform and preset to the

marketplace GPU Operator's nebius.nvidiaDriverCRDPatch.profiles values. Its

default gpu-rtx6000 selector does not match zonal gpu-rtx6000-a workers.

The override contains only the requested RTX pool, keeps RDMA disabled, and

uses a revision hash so Terraform reconciles write-only values on existing

releases. Alternate recipes must expose and wire

gpu_operator_rtx_driver_profile; incompatible recipes fail before cloud

mutation. Do not relabel workers to hide a selector mismatch.

An RTX cluster may declare gpu_driver_package_repositories as a mapping of

safe filenames to package-source text. Fleet passes it through the Operator's

driver.repoConfig and an owned ConfigMap, retaining signature verification.

Match the sources to the actual driver-image distribution. The five-cluster

example supplies Ubuntu 24.04 HTTPS sources for networks that permit HTTPS but

block HTTP. Empty configuration preserves the image defaults. Before workloads,

verify the driver pod actually mounts the configured files and can fetch its

kernel packages; do not infer network reachability from the operator VM.

The marketplace may disable automatic upgrades and use an OnDelete driver

DaemonSet. A successful Helm update then changes the template without replacing

existing pods. Compare actual pod mounts with the template. Replacing stale

driver pods is maintenance: first verify no application GPU workloads are

active, cordon each affected node, recheck workloads, and delete only the

identified stale pod with a UID precondition. Wait for its ready replacement

and restore the node's prior scheduling state. Retain private receipts and

rerun the full CUDA/graphics health gate; never delete application pods or

relax readiness to finish an upgrade.

Read-only live coverage checks exact selectors, per-node GPU quantities,

ConfigMap contents, ready driver containers, and actual repository mounts:

NPA_INTEGRATION_E2E=1 NPA_FLEET_RTX_VERIFY_SPEC=<private-spec-path> \
  NPA_FLEET_RTX_KUBECONFIGS=<private-project-cluster-path-mapping.json> \
  npa/.venv/bin/python -m pytest \
  npa/tests/e2e/test_fleet_rtx_driver_config_live.py -q

The mapping is {project_key: {cluster_name: kubeconfig_path}}; keep its exact

values outside Git. This check creates no pods and complements the real

CUDA/graphics and representative workload validation.

For qualification on every individual eight-GPU RTX cluster, additionally run

npa/tests/e2e/test_fleet_rtx_workload_live.py with the same private spec/mapping,

NPA_FLEET_RTX_RUN_WORKLOADS=1, and an owner-only

NPA_FLEET_RTX_WORKLOAD_EVIDENCE_DIR. It creates one Job per target using the

provisioning gate's immutable, payload-clean image. Each Job executes verified

CUDA arithmetic and matrix multiplication, dynamically loads GLX/EGL, and

creates a Vulkan instance with an NVIDIA physical device. It verifies the

runtime digest and deletes each Job with a UID precondition, then proves both

Job and pod absence. The evidence directory holds private execution receipts

and a separate sanitized result summary. This does not replace representative

Isaac training or the canonical Sim2Real ladder.

The RTX override also sets toolkit RUNTIME_CONFIG_SOURCE=file. With newer

containerd binaries, containerd config dump can migrate the configuration in

memory. Using that output may produce a version-4 NVIDIA drop-in beside a

version-2 root, preventing containerd startup. Reading the file preserves the

host schema; see NVIDIA's configuration-source guidance.

For an already broken node, apply the corrected toolkit configuration first.

After verifying no application workloads are active, retain the root and

drop-in files privately, move only the proven incompatible NVIDIA drop-in out

of the imports directory, validate containerd config dump, and restart

containerd. Verify the replacement toolkit produces a compatible fragment and

the full health gate passes. Do not change version numbers blindly or discard

unrelated host configuration.

A node group can report PROVISIONING again when its workers lose readiness.

Fleet treats it as zero incremental reserved demand only after a complete

Compute inventory proves the exact group/cluster/project labels, requested

template, running worker count, reservation bindings, and attached disks.

Target and actual node counts must also match. This capacity proof does not

mark the cluster healthy: every deployment readiness gate still runs.

Spec (npa.fleet/v0.0.1)

The version remains additive. A cluster without backend is the historical

mk8s shape. Explicit targets use backend: mk8s plus mk8s: {...} or

backend: soperator plus soperator: {...}; both may appear in one project or

fleet. Fleet owns target identity and shared-network inventory, while the

selected backend owns one target's plan, materialization, apply, native status,

verification, and destroy. See docs/cluster-backends.md for one-entry and

mixed examples and the fail-closed state rules.

A defaults cluster profile is deep-merged under every cluster, so identical

fleets are just project entries with no overrides. Projects may declare custom

clusters (overrides and/or several clusters), and identical + custom may be

freely mixed. Projects reference an existing project_id or a name that is

created on demand as project_prefix + name.

Project-scoped object_storage is independent of a cluster's shared

filesystem. storage_class: enhanced maps to Nebius Enhanced Throughput,

size_gibibytes becomes the bucket's exact binary capacity cap, and deploy

requires provider read-back plus a write/read/delete probe. Leave bucket_name

empty in public specs so Fleet derives a stable private name at runtime. Fleet

retains buckets and durable artifacts on cluster destroy; explicit

npa storage bucket delete remains the destructive cleanup boundary.

Fleet uses its own project-scoped storage service account and access key,

separate from LeRobot bootstrap identities, and never enables the editors

fallback. Storage reconciliation currently requires at least one selected mk8s

target in each project that declares storage; soperator-only selections fail

before mutation.

Before any project, bucket, subnet, or cluster mutation, deploy budgets all new

bucket declarations against tenant storage.bucket.count and the matching

storage.bucket.size.<class> allowance (enhanced-throughput for Enhanced).

The size allowance uses bytes, separately from filesystem quotas. Missing,

unreadable, or insufficient evidence fails closed. Every selected existing

bucket must match the exact project, name, region, active/unsuspended state,

storage class, and cap before reuse. Verified existing buckets are not charged

again as new quota demand; a new storage declaration is still checked when its

cluster is unchanged. Read/write success without verified probe deletion cannot

mark Fleet storage ready.

A bucket cap is a maximum, not reserved storage. Available tenant capacity can

change after preflight, including when other buckets grow. See the official

bucket contract

and storage quotas.

Run the read-only reservation and storage quota regression against a private

planning spec even before its target projects exist:

NPA_INTEGRATION_E2E=1 NPA_FLEET_QUOTA_VERIFY_SPEC=<private-spec-path> \
  npa/.venv/bin/python -m pytest \
  npa/tests/e2e/test_fleet_storage_quota_live_e2e.py -q

This proves capacity evidence only; project identity, actual bucket provisioning,

GPU readiness, and representative workloads remain separate deployment gates.

apiVersion: npa.fleet/v0.0.1
name: fleet1-test
tenant_id: ""                # resolved from ~/.nebius + ~/.npa when empty
region: us-central1
profile: ""                  # ~/.nebius profile to authenticate as; "" = active
project_prefix: "fleet1-test-"
defaults:
  # For RTX/Isaac rendering clusters, replace the next two driver lines with
  # gpu_workload_profile: rtx-rendering and an explicit reviewed digest:
  # gpu_graphics_smoke_image: '<reviewed-registry>/graphics@sha256:<64-hex-digest>'
  gpu_driver_mode: auto
  managed_driver_preset: cuda13.0
  allow_unsafe_nvswitch_operator: false
  gpu_health_stabilization_seconds: 120
  gpu_health_timeout_minutes: 60
  gpu_cuda_smoke: true
  cpu_nodes: { count: 1, platform: cpu-d3, preset: 48vcpu-192gb }
  gpu_nodes:
    count: 1
    platform: gpu-rtx6000
    preset: 1gpu-24vcpu-218gb
    # Optional runtime-only ID; renders STRICT and never falls back to PAYG.
    capacity_block_group: ""
  enable_filestore: true
  filestore_disk_size_gibibytes: 1024
  filestore_mount_path: /mnt/data
  filestore_mount_tag: npa-shared-fs
  # Runtime/operator-supplied standards-based chart source. Keep private
  # registry endpoints out of committed specs and PR evidence.
  filesystem_csi_chart_repository: ""
projects:
  - name: a                  # -> project fleet1-test-a (identical profile)
    object_storage:          # separate from enable_filestore
      enabled: true
      storage_class: enhanced
      size_gibibytes: 1024
  - name: b                  # -> project fleet1-test-b (identical profile)
  # - name: c                # custom: overrides + a second cluster
  #   clusters:
  #     - name: train
  #       gpu_nodes: { count: 2, platform: gpu-h200-sxm, preset: 8gpu-128vcpu-1600gb }
  #       enable_gpu_cluster: true
  #       infiniband_fabric: us-central1-a
  #     - name: infer         # inherits defaults
  # - project_id: project-existing123   # deploy into an existing project by id
  #   clusters: [ {} ]

Example spec: npa/examples/fleet/fleet1-test.yaml.

Targeting another tenant (`profile`)

A Nebius service account belongs to exactly one tenant, so deploying into a

second tenant means authenticating as that tenant's principal. Set the spec's

profile: (or pass --profile <name>, which wins) to name a ~/.nebius

profile; every nebius CLI call, the minted terraform TF_VAR_iam_token, and

the generated kubeconfig's exec-credential args are pinned to it. The machine's

active profile is never mutated, so concurrent fleets in different tenants stay

independent.

With a profile set, tenant_id resolves from that profile's tenant-id

(never the active profile's) and a profile with no tenant-id is a hard error

instead of a silent deploy into the wrong tenant. destroy falls back to the

profile recorded in each cluster's env sidecar at deploy time, so a teardown

always authenticates as the principal that created the cluster.

Register a service-account profile non-interactively:

nebius profile create <name> --endpoint api.nebius.cloud \
  --service-account-id <sa-id> --public-key-id <public-key-id> \
  --private-key-file-path ~/.nebius/<name>.pem \
  --parent-id <sa-parent-project> --tenant-id <tenant> --skip-auth
nebius --profile <name> iam get-access-token >/dev/null   # verify

nebius profile create also activates the new profile; re-activate the

previous one (nebius profile activate <prev>) if other tooling on the host

depends on it.

Procedure

Parallel applies use a shared download cache only during initialization. NPA

holds the cache lock through initialization and copying each target's selected

providers into its own Terraform data directory. Later initialization can then

rewrite cached downloads without changing binaries used by another apply or

destroy. Dependency-lock checksum verification remains enabled.

Older recipe sources can omit newer regions from their default-node table.

Materialization preserves known-region defaults while allowing explicit

platforms and presets in other regions. It supplies no guessed GPU or fabric;

resolve those values from the provider inventory before deployment.

  1. Keep committed files public-safe: never hardcode tenant/project/registry IDs

or SSH keys. The spec resolves tenant/region from ~/.nebius/config.yaml and

~/.npa/config.yaml when its fields are empty; the SSH public key comes from

ssh_public_key or ~/.ssh/id_ed25519.pub / id_rsa.pub.

  1. Plan first (no infra): npa fleet plan --spec fleet.yaml shows the

projects (create vs existing) and per-cluster node config.

  1. enable_gpu_cluster is auto: GPU clustering (InfiniBand fabric) is only

valid on fabric-capable 8-GPU SXM presets. Single-GPU presets (e.g. RTX PRO

6000 1gpu-24vcpu-218gb) auto-set enable_gpu_cluster=false; set it true

only with an 8-GPU preset and infiniband_fabric.

Every GPU pool defaults to gpu_driver_mode: auto, which selects Nebius's

managed driver image plus the provider device plugin; CPU-only clusters emit

no GPU-driver input. managed_driver_preset defaults to the vendored

recipe's supported cuda13.0 and is configurable. operator remains an

explicit escape hatch, but NVSwitch topologies reject it unless

allow_unsafe_nvswitch_operator: true acknowledges the Network

Operator/MOFED versus Fabric Manager host-device race. The same strategy

resolver applies to npa cluster up and Fleet.

  1. Bind reserved GPU capacity explicitly when required. Set

gpu_nodes.capacity_block_group to a runtime-supplied Capacity Block Group

ID. Fleet renders gpu_nodes_reservation_policy = { policy = "STRICT", ... },

so an unavailable or incompatible block fails instead of falling back to

ordinary on-demand capacity. Never commit a live capacity block ID.

Discover and verify reservations read-only with:

```bash

nebius --profile <p> capacity capacity-block-group list \

--parent-id <tenant> --all --format json

nebius --profile <p> capacity capacity-interval list \

--parent-id <capacity-block-group> --all --format json

nebius --profile <p> capacity capacity-block-group list-resources \

--id <capacity-block-group> --format json

nebius --profile <p> capacity resource-advice list \

--parent-id <tenant> --all --format json

```

Preflight requires the named block to be active, in the target tenant and

region, and matched to the GPU platform and InfiniBand fabric. It checks the

aggregate GPU requirement against remaining reserved capacity. Only after

that validation does it exclude those GPUs from ordinary GPU quota; all

node, boot-disk, GPU-cluster, Kubernetes, and storage quotas still apply.

  1. Preflight quotas at the tenant, before anything else. Each cluster needs,

in the target region: compute.instance.count (regular worker nodes only; the

managed control plane is service-owned),

compute.instance.non-gpu.vcpu for the CPU preset,

compute.instance.gpu.<family> for regular unreserved GPU workers (on-demand

GPU quota is frequently 0). Preemptible GPU workers use

compute.instance.preemptible.count instead: this counts worker VMs, so an

eight-GPU worker needs one slot. They do not consume regular VM or GPU-family

quota. CPU workers retain the recipe's regular allocation mode. Both GPU

modes still require compute.disk.count/compute.disk.size.network-ssd,

compute.gpucluster.count when enable_gpu_cluster, and

compute.filesystem.count + compute.filesystem.size.network-ssd when

enable_filestore. Each private worker consumes two

vpc.allocation.count slots (its private address and pod alias range); the

managed control-plane endpoint is service-owned. A create-on-demand project

additionally needs one vpc.network.count, one vpc.subnet.count, two

vpc.pool.count, one vpc.routetable.count, and one vpc.route.count.

List them all at once with

nebius --profile <p> quotas quota-allowance list --parent-id <tenant> --all --format json

(each item carries metadata.name, spec.region, spec.limit).

deploy does this automatically (--preflight, on by default) and refuses to

apply when a capacity block or tenant limit cannot cover the in-scope

clusters; --no-preflight attempts it anyway. Before calculating

creation-only VPC requirements, preflight lists projects once and reuses an

existing immutable project ID when a name already exists. An unreadable

project inventory fails closed rather than assuming the project exists.

Both explicit project_id targets and projects resolved by name require a

provider read verifying exact ID, tenant, region, active state, and absence of

suspension or deletion. An explicit ID may use a local Fleet role whose name

differs from the provider project name. With --no-create-projects, a missing

target aborts the entire preflight before any project's storage or workers

are created; never substitute a stale or deleting project from local state.

Run the read-only live identity regression against an owner-private spec with

explicit tenant, region, profile, and project IDs:

```bash

NPA_INTEGRATION_E2E=1 NPA_FLEET_PROJECT_VERIFY_SPEC=<private-spec-path> \

npa/.venv/bin/python -m pytest \

npa/tests/e2e/test_fleet_project_identity_live_e2e.py -q

```

This checks valid identity and rejects mismatched tenant/region selections.

It creates no resources and does not replace GPU or workload validation.

The allowance read is paged to completion and selects records whose

metadata.parent_id is the requested tenant. A project/unset allowance can

never shadow a finite tenant allowance; duplicate finite evidence must agree

exactly. Older unscoped records are a fallback only when no authoritative

tenant record exists. Required finite allowances fail closed when their

limit, unit, state, or consumption evidence cannot be interpreted. Exact

usage wins; otherwise the API's fractional status.usage_percentage is used

(values above 1 mean over-limit), and USAGE_STATE_NOT_USED is accepted as

zero consumption. Disk/filesystem sizes require byte; vCPU and GPU quotas

accept only their explicit compatible count/vcpu and count/gpu units.

A selected unlimited allowance may omit status because no arithmetic is

required.

The five creation-topology allowances (vpc.network.count,

vpc.subnet.count, vpc.pool.count, vpc.routetable.count, and

vpc.route.count) are optional catalog entries: when absent from a completed,

readable regional tenant catalog, preflight reports them as unadvertised and

does not reject the region. If any is advertised with a finite limit, it is

checked strictly. All compute, disk, mk8s, allocation, GPU-cluster, and

filesystem allowances required by the selected shape remain mandatory.

Project-level allowances only subdivide the tenant allowance, so a tenant

limit of 0 cannot be worked around by creating a project quota: raising a

tenant allowance is a root-g00root operation and a tenant-scoped service

account gets PermissionDenied ... resource ID: root-g00root. A new tenant

therefore needs its GPU/filesystem quotas raised by the Nebius account team

before any GPU or shared-filesystem cluster can be applied.

  1. Deploy (asks for confirmation): npa fleet deploy --spec fleet.yaml. It

prints the projects/clusters it will create/update and prompts before acting;

pass --yes/-y for non-interactive runs. Missing projects are created via

the nebius CLI unless --no-create-projects. Deploy runs per cluster and

continues past a failing target (--fail-fast to stop); a JSON summary lists

deployed vs failed clusters with kube contexts. A successful kubeconfig

write also registers the fleet target under ~/.npa/clusters/<context> so

project-scoped workflow, controller, and provision-if-absent commands can

consume it without a second manual cluster registration step.

Fleet's unique local context may differ from the provider cluster name.

Exact controller cleanup compares --cluster-name with the saved

provider_name, while still verifying the immutable project/cluster IDs

and the saved kubeconfig against the live provider.

  1. Select the qualified MK8s release: omit source overrides to create a new

installation with the date-versioned mk8s-v2026-10-19 release. It binds

upstream main-v2026-10-12, the exact upstream commit, the complete patched

bundle digest, the Terraform provider-lock digest, and the component/config

contract. NPA writes that record before Terraform applies. Reconcile, status,

and destroy retain the saved record; a different --mk8s-release requires a

reviewed migration or replacement, never an in-place update. --k8s-training-ref

and --k8s-training-dir are reviewed source overrides, not an alias for a

moving upstream branch. NPA applies its compatibility preparation after

materializing every accepted source,

including the package-only pinned-ref fallback; currently this removes

kubectl debug --quiet from the filesystem verifier because kubectl 1.36

otherwise hides both required success evidence and the debugger-pod name.

For GPU clusters it also inspects the materialized recipe's variables and

gpu_settings wiring. If the selected managed-driver mode/preset cannot be

represented, deployment fails with an actionable compatibility error rather

than silently reverting to the operator driver. MIG-enabled targets also

require all seven pinned Operator/lifecycle variables in the resolved recipe;

this check runs before quota, project, subnet, or Terraform mutation.

  1. Status / teardown: npa fleet status --spec fleet.yaml; `npa fleet

destroy --spec fleet.yaml (prompts; --yes/-y or --force` to skip).

  1. MIG readiness is part of deploy. A MIG-enabled cluster is not marked

deployed until two consecutive exact snapshots agree. `npa fleet verify-mig

--spec fleet.yaml --output json is the read-only diagnostic; add --wait

--reconcile` to perform the single ordered GFD/device-plugin stale-resource

repair. It removes only the exact obsolete

nvidia.com/gpu=mig-not-ready:NoSchedule taint from a successful replacement

worker, preserving unrelated taints. It also reconciles a stale OnDelete

driver pod template one worker

at a time, but only after failing closed on every active application pod that

requests an nvidia.com/* resource; operators must delete those workloads

explicitly. Nonzero nvidia.com/gpu in either capacity or allocatable,

cordoned/NotReady nodes, or stale Operator/DaemonSet generations are always

failures. Readiness, driver replacement, and a mandatory representative

mig-1g.24gb CUDA vectorAdd/MIG-identity smoke share

gpu_health_timeout_minutes; timeout or smoke cleanup failure leaves the

cluster in validation-failed state instead of reporting deployment success.

Add / remove clusters and projects

For concurrent workflows from one operator host, keep each project's SkyPilot

state and API endpoint separate. An isolated HOME does not isolate SkyPilot's

default listening port. Supply the operator-managed endpoint through

SKYPILOT_API_SERVER_ENDPOINT, with a stable HOME, user identity, and exact

project kubeconfig on its server. NPA inspects only the selected local port;

unrelated servers cannot poison a healthy selected server's check. Legacy

HOME, user-ID, or kubeconfig staleness remains automatically repairable when

stopping the local daemon is safe. Explicitly conflicting runtime ownership or

another daemon that SkyPilot's stop API could affect blocks repair before any

server is stopped.

Remote API endpoints use SkyPilot's API/controller checks instead of local

procfs inspection. Preserve the same endpoint and state when monitoring or

cancelling the run.

The workflow submitter waits for SkyPilot's API launch result while detaching

the actual workload. A rejected storage or image precheck therefore surfaces

as a launch error instead of an accepted request with no observable job. For

durable Nebius mounts, configure the exact project's nebius AWS storage

profile in that isolated HOME and verify storage access before submission.

Restrict Nebius to its storage capability when compute must stay on the existing

reserved Kubernetes fleet.

The fleet is spec-driven and idempotent, so growing or shrinking it is targeted:

those — npa fleet deploy --spec fleet.yaml --only-projects c,d or

--only-clusters train,infer. Existing clusters are reconciled in place and

untouched clusters are left alone (the persisted summary is merged, not

overwritten).

train (or --only-projects c`). Destroy tears down each spec-declared

cluster that has local state, reclaims any project VPC network the fleet

created after the last cluster state is gone, and drops local state only after

authoritative Terraform teardown succeeds. An incomplete destroy reports

destroy-incomplete, retains its exact state, and prints a scoped retry

command. It does not enumerate clusters via the API, so a cluster created

out-of-band is not reclaimed. Omitting --only-* tears down the whole fleet.

Both deploy and destroy confirm before acting (bypass with --yes/-y;

destroy also accepts --force).

Gotchas

install dir + local state under ~/.npa/fleet/<name>/<project>/<cluster> and

an env sidecar so destroy can rebuild the required TF_VAR_*. The sidecar's

status starts as provisioning. GPU clusters move through

validating-gpu-health and are promoted to deployed only after the requested

Ready-node/GPU topology, absence of NebiusGPUError, exposed Fabric state,

driver components, stable boot IDs, and per-node CUDA vectorAdd all pass for

the configured stabilization interval. Health failures report

deployed-validation-failed; credential failures report

deployed-credentials-failed. Both retain Terraform/cloud state, kubeconfig,

and local evidence for diagnosis and an idempotent retry.

target as zero incremental quota only when its saved tfvars still match and

the exact provider project, cluster, and node groups are all running with the

requested shapes. Reserved pools must still report non-preemptible nodes and

the exact STRICT reservation binding; stale or incomplete evidence falls

back to the ordinary conservative quota preflight.

The same capacity proof applies during GPU validation or after a later

application failure: a partial apply must have an exact saved cluster identity

(or one matching local Terraform cluster resource), plus running provider

groups. Split reserved pools are matched as separate groups. Explicit project

IDs take precedence over public aliases, and an RTX Helm selector update is

excluded from capacity demand. The v1 API represents preemption with an Empty

marker ({} enables it; omission disables it), which is decoded at the API

boundary before strict reservation matching. Unknown state, wrong identity,

missing groups, changed capacity, or non-STRICT reservation evidence still

fails closed.

api.nebius.cloud for non-EU regions automatically (EU uses

api.eu.nebius.cloud). If the upstream recipe drifts (renames provider.tf,

moves the provider block, or changes the default domain), the patch becomes a

no-op and the deploy logs a loud WARNING rather than silently talking to the

wrong endpoint.

rendered terraform.tfvars targets the recipe's current variable surface --

the pinned filesystem_csi.chart_version, the loki/observability toggles,

and the o11y/kuberay/gatekeeper enable_* flags. Pulling a newer recipe whose

variables changed can require updating fleet/tfvars.py; validate with

npa fleet plan + a terraform plan before a fleet-wide apply.

an affected spec to auto/managed-image, perform a controlled rolling

node-group update or recreation. A newer NPA binary alone cannot repair

already-booted operator-driver nodes; preserve reservation capacity and obey

workload disruption policy while replacing them.

per cluster and consumes tenant compute.filesystem.count +

compute.filesystem.size.network-ssd quota. Set enable_filestore: false

(or raise quota) if the tenant is at its filesystem limit.

CPU and GPU node-group template with filestore_mount_tag, and cloud-init

persists the same tag at filestore_mount_path as virtiofs with

defaults,nofail. Nebius warns that omitting nofail can prevent a node from

booting after the filesystem is missing. The bundled CSI chart version is

0.1.6, matching the current official filesystem-over-CSI guide. Set

filesystem_csi_chart_repository at runtime when the selected recipe has no

public chart default; fleet plan reports only whether CSI is enabled and

never echoes that repository endpoint.

resolves one project network/subnet before parallel cluster applies and stores

ownership in .npa-fleet-network.json. All clusters without explicit

overrides share that authoritative subnet. destroy reclaims exactly that

pair (subnet then network) after every project cluster state is gone. A

reused pre-existing subnet is left untouched, and created projects are

never deleted.

destroys N clusters at once. Each cluster has isolated terraform state, so there

is no lock contention; the provider plugin cache is pre-warmed once (a single

init) to avoid concurrent-init corruption, and each cluster writes restrictive

per-cluster diagnostics to <install_dir>/deploy.log or the surviving

<fleet_root>/.logs/<project>/<cluster>/destroy.log. JSON mode uses the same

logs even for sequential or one-target runs so stdout remains one JSON document.

Wall-clock drops from sum to ~max of the applies. Project network resolution

remains sequential and single-flight, eliminating duplicate network/subnet

creation in a fresh shared project; explicit per-cluster subnet_id values are

preserved.

exec-plugin; npa strips it for nebius/terraform calls unless

NPA_REUSE_IAM_TOKEN is set (CI injecting a short-lived token). This is also

why --profile must be threaded through rather than relying on the ambient

token: the token, not the profile, decides the principal.

The current vendored recipe uses the explicit profile for refreshable Nebius

authentication and profile-bound Kubernetes credential exec plugins. NPA

removes the minted token's provider override for compatible recipes, so a

long apply or destroy does not keep using the token minted before workers

began provisioning. Older recipes retain their minted-token behavior; use

the vendored recipe when long operations outlive that token.

filesystem CSI (csi-mounted-fs-path-sc, ReadWriteMany) only when a shared

filesystem is attached. Without it the only class is

compute-csi-default-sc (provisioner compute.csi.nebius.com, ReadWriteOnce

disk-over-CSI); a PVC naming csi-mounted-fs-path-sc then sits Pending with

ProvisioningFailed: storageclass ... not found and its pod never schedules.

node group whose instances it cannot create, then retries forever while compute

rejects each one. Terraform only prints Still creating... until the timeout,

and the real reason is visible solely in the node group's own events:

nebius --profile <p> mk8s node-group get --id <ng> --format json shows

QuotaFailure with quota, limit, and requested. This is exactly why the

quota preflight exists — the node group's k8s-side state is PROVISIONING, not

FAILED, so nothing else surfaces the wall.

ordinary on-demand capacity. Fleet's capacity_block_group surface therefore

always renders STRICT and validates that exact block before apply.

>= 1.12 version constraint. Deploy and destroy assert machine-readable

terraform version -json output before lifecycle work; set

NPA_TERRAFORM_BIN if the system terraform is older.

Verify

npa fleet plan --help
npa fleet deploy --help
npa fleet verify-mig --help
npa fleet verify-storage --help
npa fleet verify-graphics --help
npa/.venv/bin/python -m pytest npa/tests/unit/test_fleet_cli.py -q
Use this skill with your AI agent: Open on Skill Issue to copy, download, or add to your library. Works with Claude, ChatGPT, Gemini, Cursor, Windsurf and more.