Units and Constants Router
Use this sub-skill when a task centers on Astropy physical units, unit-aware
arrays, conversions, equivalencies, constants, or unit validation.
Load This When
- The user asks for
Quantity,Unit,u.Quantity,.to(),.to_value(),
.decompose(), .si, .cgs, or unit arithmetic.
- A value must carry units through NumPy operations or an astronomy formula.
- A conversion needs an equivalency: spectral wavelength/frequency/energy,
Doppler velocity, temperature, parallax, brightness temperature, or
dimensionless angles.
- The task defines custom units, parses unit strings, validates physical types,
or needs VOUnit/FITS/CDS formatting.
- Constants such as
c,G,h,M_sun, or versioned CODATA/IAU constants
are involved.
Route Away When
- Coordinate frames,
SkyCoord,Time, or observation locations dominate; use
../time-coordinates/SKILL.md.
- Unit-bearing table serialization is the main issue; use
../tables-io/SKILL.md.
- Cosmological units or built-in cosmology realizations dominate; use
../cosmology/SKILL.md.
- The problem is installation or optional dependency setup; use
../cli-config-data/SKILL.md or the root troubleshooting reference.
First Actions
- Identify whether each input is a scalar, NumPy array,
Quantity,Unit,
string unit, or constant.
- Convert to a
Quantityearly:value * u.unitoru.Quantity(value, unit). - Keep quantities unit-aware until an external package requires raw values.
- Use
.to(target_unit, equivalencies=...)for conversion and.to_value(...)
only at boundaries.
- If
.to()fails, decide whether an equivalency is scientifically justified. - For constants, inspect the attached unit and whether SI/CGS ambiguity exists
before using a raw .value.
- Validate output with a dimensional check:
quantity.unit.is_equivalent(...)
or quantity.physical_type.
References
- references/api-reference.md lists the verified
constructors and key APIs for units, quantities, equivalencies, and constants.
- references/workflows.md gives self-contained
recipes for unit-aware calculations, equivalencies, custom units, NumPy
interop, and constants.
conversion errors, cgs electromagnetic ambiguity, lost units, parser strictness,
and formatting pitfalls.
Safety and Validation
- Never silently strip units for convenience. If a raw number is required,
state the target unit used for .to_value().
- Do not apply an equivalency unless the science context warrants it; record
which equivalency was used.
- Avoid comparing raw
.valueacross quantities with different but compatible
units.
- Use constants as quantities (
const.c,const.G) rather than copying numeric
values into code.
- For publication or reproducibility, mention the constants version if a result
depends sensitively on CODATA/IAU revisions.
Native-Backed Validation Ideas
- Convert
42 * u.km / u.stou.m / u.sand assert42000. - Convert wavelength to frequency with
u.spectral()and assert the output unit
is equivalent to Hz.
- Use a constant in an expression and assert the resulting unit is physically
expected.