proteomics-ms-qc
When to use
Numeric columns excluding metadata-like names are samples; if none remain, all numeric columns are used. Zero and NaN count as missing.
Use existing search-engine tables; this skill does not search raw spectra.
Use from a step
from skills._sdk.notebook import load_skill, write_output
library = load_skill('proteomics-ms-qc')
data = library.demo_data(random_state=42)
result = library.quality_control(data)
write_output(result, 'tables/qc_metrics.csv')
For real data, use read_input and pass any read_table helper as reader=.
The executable examples/example_step.py also checks the result and writes a Figure.
API
<!-- api:begin generated from _api.py; regenerate with run.py api <skill dir> --write -->
`quality_control(data: pd.DataFrame) -> pd.DataFrame`
Return a one-row QC table without changing input intensities.
:param data: Protein rows and numeric intensity columns; metadata-like names are excluded when possible.
:returns: Scalar QC metrics; per-sample completeness and selected columns are in run_info.
:raises ValueError: There are no proteins or numeric intensity columns.
`run_info(table: pd.DataFrame, *, keep: bool=True) -> dict`
Read QC diagnostics.
:param table: Output of quality_control.
:param keep: True preserves attrs; False removes diagnostics.
:returns: A separate dictionary with selected sample columns and completeness.
:raises TypeError: The input is not a DataFrame.
`completeness_figure(table: pd.DataFrame)`
Plot detected protein percentages per sample.
:param table: QC table retaining run_info attributes.
:returns: A matplotlib Figure without writing files.
:raises KeyError: QC diagnostics are absent.
`demo_data(*, random_state: int=42) -> pd.DataFrame`
Generate a synthetic protein intensity table.
:param random_state: CLI seed 42; change for another simulation.
:returns: One hundred proteins and five sample columns.
:raises ValueError: The seed is invalid.
<!-- api:end -->
Methods and parameters
Numeric columns excluding metadata-like names are samples; if none remain, all numeric columns are used. Zero and NaN count as missing.
Functions return new DataFrames. run_info(result) reads diagnostic attrs;
use keep=False before serialization when those attrs are not needed.
Gotchas
- quality_control reports per-protein CV across positive intensities. run_info retains the actual sample columns and per-sample completeness.
demo_datauses seed 42, matching the CLI; every demo is synthetic.run_infolives in DataFrame attrs and is not preserved by CSV serialization.
Inputs and outputs
The CLI reads CSV tables and writes:
- tables/qc_metrics.csv
- report.md
- result.json
demo_proteomics.csvis written only with--demo.
reproducibility/commands.shrecords the CLI invocation template.
Functions return data and Figures without writing files. Steps own their outputs.
Demo mode also writes its synthetic input when the original CLI used a file.
CLI
python skills/proteomics/proteomics-ms-qc/proteomics_ms_qc.py --demo --output /tmp/proteomics_ms_qc
For real input replace --demo with --input <table>.
See also
references/methodology.mdreferences/parameters.mdreferences/output_contract.mdproteomics-data-importfor protein-table normalization;proteomics-defor comparisons.
Dependencies
numpy, pandas, matplotlib