Blueprint engine

From Tibsfox/gsd-skill-creator · View interactive version

Blueprint engine is an AI agent skill from the GitHub repository Tibsfox/gsd-skill-creator. Generates engineering-standard drawings (P&ID, SLD, floor plans, isometric) with ISA-5.1 and IEEE symbol libraries in SVG/DXF format. Activates for drawing generation, diagram creation, blueprint packaging, and output formatting from verified engineering calculations.

How to use this skill

Skill file

Blueprint Engine Skill

At a Glance

Convert verified engineering calculations into standard engineering drawings: P&ID, SLD, floor plans, and isometric piping views with SVG/DXF output.

Activation: BlueprintPackage generation request, any drawing type request (P&ID, SLD, floor plan, isometric), SVG/DXF output formatting, or title block creation.

Key capabilities:

Drawing types:

| Drawing Type | Standard | Primary Use |

|-------------|----------|-------------|

| P&ID | ISA-5.1 | Piping and instrumentation, fluid systems |

| SLD | IEEE | Single-line electrical diagrams, power distribution |

| Floor Plan | Site-specific | Equipment layout, spatial relationships |

| Isometric | ASME | 3D pipe routing in 2D representation |

Output formats: SVG (primary, web-renderable) and DXF (CAD import via svg2dxf).

When to use this skill:

Mandatory in every drawing:

ENGINEERING DISCLAIMER
This output was generated by an AI assistant and has NOT been reviewed
by a licensed Professional Engineer (PE). All calculations, drawings,
and specifications must be verified by a qualified professional before
use in any construction, installation, or operational context. Local
building codes, electrical codes, and plumbing codes may impose
requirements not captured in this output. The user assumes all
responsibility for verification and compliance.

ENGINEERING DISCLAIMER: All drawings generated by this skill must be verified by a licensed Professional Engineer (PE) before use in construction, installation, or operational contexts. This disclaimer is non-removable and applies to all output formats.

Quick routing:


Drawing Generation Pipeline

All drawing types share a six-step SVG generation pipeline:

Step 1: Layout Grid

Set up a coordinate system based on paper size and scale:

Paper: A1 (841x594mm at 1:50 scale -> drawing area covers 42m x 29.7m real-world)
Grid: 10mm base grid for component snapping
Margins: 20mm all sides, 50mm bottom for title block
Origin: Top-left at (20, 20)mm

Standard paper sizes:

Standard scales: 1:20, 1:50, 1:100, 1:200, 1:500, NTS (not to scale)

Step 2: Component Placement

Place symbols from the symbol library at specified coordinates:

// Reference the ISA-5.1 library (from references/symbols/symbols-pid.ts)
// or IEEE library (from references/symbols/symbols-electrical.ts)
import { PID_SYMBOLS } from './references/symbols/symbols-pid.js';
import { ELEC_SYMBOLS } from './references/symbols/symbols-electrical.js';

const symbol = PID_SYMBOLS['centrifugal-pump'];
// Place at grid coordinate with optional rotation
const placed = placeSymbol(symbol, { x: 150, y: 200 }, { rotation: 0 });

Step 3: Connection Routing

Route pipes and wires between components with automatic bend detection:

Step 4: Dimensions and Annotations

Step 5: Title Block Generation

import { TitleBlock } from '../../types/infrastructure.js';

const titleBlock: TitleBlock = {
  projectName: 'Data Center Cooling System',
  drawingNumber: 'P&ID-001',
  revision: 'Rev. A',
  date: '2026-02-27',              // ISO 8601
  drawnBy: 'Claude (AI-Assisted)',
  checkedBy: 'VERIFY WITH LICENSED PE',  // ALWAYS this value -- non-configurable
  scale: '1:50',                    // or "NTS"
  sheet: '1 of 3',
};

Title block occupies bottom 50mm of drawing. PE disclaimer printed in title block as non-removable text element.

Step 6: SVG Output

<svg xmlns="http://www.w3.org/2000/svg"
     width="841mm" height="594mm"
     viewBox="0 0 841 594">
  <!-- Drawing content: components, connections, dimensions -->
  <!-- Title block with PE disclaimer -->
  <text class="disclaimer" x="20" y="560">
    NOT FOR CONSTRUCTION -- Verify with Licensed PE before use
  </text>
</svg>

For DXF output: Use svg2dxf library or generate DXF directly using the DXF R12/2000 ENTITIES section format. Include all layers: PROCESS, INSTRUMENT, ELECTRICAL, DIMENSIONS, TITLE_BLOCK, DISCLAIMER.


P&ID Generation (BLUPR-01, BLUPR-07)

P&IDs follow ISA-5.1 conventions. Load symbol library from references/symbols/symbols-pid.ts.

Required elements:

  1. Process equipment (pumps, heat exchangers, tanks, vessels) with ISA tag numbers
  2. All process piping with pipe class notation (size, schedule, material)
  3. All instrumentation with balloon notation (TI-101, PI-201, FIC-301)
  4. Control loops connecting field instruments to controllers
  5. Valve manifolds with type (gate, globe, ball, butterfly, check, relief)
  6. Line types: Process (solid heavy), instrument signal (dashed), electrical (dot-dash)

Tag numbering convention:

Data center cooling P&ID example elements:


SLD Generation (BLUPR-02, BLUPR-08)

Single-line diagrams (SLDs) follow IEEE standard conventions. Load symbol library from references/symbols/symbols-electrical.ts.

Required elements:

  1. Utility service entry point (top of diagram)
  2. Main service disconnect and overcurrent protection
  3. Bus topology: Main bus -> sub-panels -> load circuits
  4. All protective devices (breakers, fuses) with amperage rating
  5. Transformers with primary/secondary voltage and kVA rating
  6. Loads with phase assignment and connected load in kVA/kW
  7. Grounding symbols at each service point

SLD layout convention:

Data center SLD example structure:

Utility Service (480V 3-Phase 4W)
    |
Main Switchgear (480V, 2000A MCB)
    |
480V Main Bus
    |-------------------------------|
    |                               |
UPS Input Feeder (480V, 400A)     MDP Feeder (480V, 600A)
    |                               |
UPS (480V/208V, 300kVA)           MDP-A (480V)
    |                               |
208V/120V Distribution Bus        PDU-A1 (208V, 100kVA)
    |-------------|                 |
    |             |                 IT Loads (208V, ~80kW)
Panel-A         Panel-B
(lighting)      (receptacles)

Floor Plan Overlay (BLUPR-03)

Floor plans show equipment physical layout in plan view (top-down).

Conventions:

Data center floor plan elements:

Coordinate system: Origin at lower-left structural column. All dimensions in millimeters. Grid on structural module (typically 600mm or 1200mm).


Isometric Drawing (BLUPR-04)

Isometric drawings show 3D pipe routing on a 2D plane.

Projection math:

Isometric grid point calculation:
  Screen x = (real_x - real_y) * cos(30) * scale
  Screen y = (real_z * scale) - (real_x + real_y) * sin(30) * scale
  Where: cos(30) = 0.866, sin(30) = 0.5

Required elements:

Piping isometric conventions:


Scale Management

Scale selection based on system size and drawing purpose:

| System Size | Recommended Scale | Paper Size |

|-------------|------------------|------------|

| Single equipment | 1:20 | A3 |

| Room/module | 1:50 | A1 |

| Floor/building | 1:100 | A1 or D |

| Campus/site | 1:200 or 1:500 | E |

| P&IDs | NTS (schematic) | A1 |

| SLDs | NTS (schematic) | A1 |

Scale annotation: Written as ratio ("1:50") in title block and as graphic scale bar on floor plans and isometrics. P&IDs and SLDs use "NTS" (not to scale) -- they are schematic, not dimensional.


Deep Tier (loaded on demand for complex drawing scenarios)

Advanced SVG Techniques

SVG symbol definition for reuse:

<defs>
  <symbol id="centrifugal-pump" viewBox="0 0 40 40">
    <!-- Circle body -->
    <circle cx="20" cy="20" r="15" fill="none" stroke="black" stroke-width="2"/>
    <!-- Impeller blades (simplified) -->
    <line x1="20" y1="5" x2="20" y2="35" stroke="black" stroke-width="1.5"/>
    <line x1="5" y1="20" x2="35" y2="20" stroke="black" stroke-width="1.5"/>
    <!-- Suction/discharge nozzles -->
    <line x1="0" y1="20" x2="5" y2="20" stroke="black" stroke-width="2"/>
    <line x1="20" y1="0" x2="20" y2="5" stroke="black" stroke-width="2"/>
  </symbol>
</defs>
<!-- Place it: -->
<use href="#centrifugal-pump" x="100" y="200" width="40" height="40"/>

Connection routing algorithm:

For orthogonal pipe routing between two points (x1,y1) and (x2,y2):

  1. If delta-x > delta-y: route horizontal first, then vertical (L-shape)
  2. If delta-y > delta-x: route vertical first, then horizontal
  3. If points share x or y coordinate: direct line
  4. For complex layouts: use intermediate waypoints to avoid equipment conflicts
  5. Mark T-junction with filled circle (3px radius) where pipes cross a connected run

DXF R2000 generation pattern:

0
SECTION
2
ENTITIES
0
LINE
8       (layer name)
PROCESS_PIPE
10      (X start)
100.0
20      (Y start)
200.0
30      (Z start, usually 0)
0.0
11      (X end)
250.0
21      (Y end)
200.0
31      (Z end)
0.0
0
ENDSEC
0
EOF

Layers for DXF export:

Multi-Sheet Drawing Sets

For complex systems, generate a drawing set with consistent numbering:

Drawing Set Structure:
  PROJ-P&ID-001: Overall P&ID - System Overview
  PROJ-P&ID-002: P&ID - Cooling Water System
  PROJ-P&ID-003: P&ID - Chilled Water Distribution
  PROJ-SLD-001: SLD - Main Power Distribution
  PROJ-SLD-002: SLD - UPS and PDU Details
  PROJ-FP-001: Floor Plan - Overall Equipment Layout
  PROJ-ISO-001: Isometric - Cooling Water Piping
  PROJ-ISO-002: Isometric - Chilled Water Piping

Sheet index in each drawing's title block: "Sheet X of Y"

Revision control: All sheets in a set share the same revision level on release.

Annotation Standards

Dimension lines:

Equipment callout balloons:

Notes and legends:

DrawingSpec and BlueprintPackage Integration

All generated drawings produce DrawingSpec objects that assemble into a BlueprintPackage:

import { DrawingSpec, TitleBlock, BlueprintPackage } from '../../types/infrastructure.js';

// Each drawing type produces a DrawingSpec
const pidDrawing: DrawingSpec = {
  type: 'P&ID',
  format: 'svg',
  scale: 'NTS',
  revisionNumber: 1,
  titleBlock: {
    projectName: 'Data Center Cooling',
    drawingNumber: 'DC-P&ID-001',
    revision: 'Rev. A',
    date: new Date().toISOString().split('T')[0],
    drawnBy: 'Claude (AI-Assisted)',
    checkedBy: 'VERIFY WITH LICENSED PE',  // mandatory, non-configurable
    scale: 'NTS',
    sheet: '1 of 4',
  },
  content: '<svg>...</svg>',  // Full SVG content
};

// Package all drawings together
const blueprintPackage: BlueprintPackage = {
  drawings: [pidDrawing, sldDrawing, floorPlanDrawing, isoDrawing],
  calculations: calculationRecords,
  bom: billOfMaterials,
  safetyReview: safetyResult,
};

Skill: pie-blueprint-engine v1.0.0

Domain: physical-infrastructure

Safety: mandatory-pe-disclaimer

Use this skill with your AI agent: Open on Skill Issue to copy, download, or add to your library. Works with Claude, ChatGPT, Gemini, Cursor, Windsurf and more.