Parsing lab values

From maziyarpanahi/openmed · View interactive version

Parsing lab values is an AI agent skill from the GitHub repository maziyarpanahi/openmed. Parse laboratory values and reference ranges from clinical text and flag results as low, normal, high, or critical with OpenMed. Use when the user needs to interpret lab results, compute abnormal flags, parse reference ranges like \"135-145\" or \"<5\", honor an originating-lab flag (H/L/critical),

How to use this skill

Skill file

Parsing lab values

Lab results in clinical text arrive as a value, a unit, and a reference range

("Sodium 132 mmol/L (135–145)"). To act on them you need a structured

abnormal flag — is 132 low, normal, high, or critical? OpenMed's

openmed.clinical lab helpers parse the reference range deterministically and

derive the flag, honoring any explicit flag the originating lab already supplied.

The helpers are unit-agnostic by design: they compare numbers within a stated

range and never convert units, so a mmol/L value is never silently compared

against a mg/dL range.

When to use

need to classify each as low / normal / high / critical.

labs table, or interpret values like <5, >=10, 0.5 - 1.2.

a derived comparison.

Quick start

from openmed.clinical import (
    parse_reference_range, derive_abnormal_flag, LAB_FLAG_ADVISORY,
)

# Closed range
rng = parse_reference_range("135-145")
# -> {"low": 135.0, "high": 145.0, "low_inclusive": True, "high_inclusive": True}

derive_abnormal_flag(132, rng)            # "low"
derive_abnormal_flag(140, "135-145")      # "normal"  (raw range string accepted)
derive_abnormal_flag(150, "135 to 145")   # "high"

# One-sided bounds
derive_abnormal_flag(7, parse_reference_range("<5"))    # "high" (above the cap)
derive_abnormal_flag(3, parse_reference_range(">=10"))  # "low"

# Honor the lab's own explicit flag (takes precedence over derived comparison)
derive_abnormal_flag(132, "135-145", explicit_flag="C")   # "critical"
derive_abnormal_flag(132, "135-145", explicit_flag="HH")  # "critical"

# Unparseable / non-numeric inputs fail safe rather than guessing
derive_abnormal_flag("pending", "135-145")  # "unknown"
derive_abnormal_flag(132, "see report")     # "unknown"

print(LAB_FLAG_ADVISORY)  # surface this disclaimer with derived flags

AbnormalFlag is one of "low" | "normal" | "high" | "critical" | "unknown".

ReferenceRange is a typed mapping of low, high, low_inclusive,

high_inclusive.

Workflow

  1. Get value + range + (optional) lab flag from extracted lab entities. The

value should be numeric; the range may be a raw string or a parsed mapping.

  1. Parse the reference range with parse_reference_range. It handles closed

ranges ("135-145", "0.5 - 1.2", "135 to 145", en/em dashes) and

one-sided bounds ("<5", "<=5", ">10", ">=10"). Contradictory or

unparseable ranges return empty bounds rather than a guess — by design.

  1. Derive the flag with derive_abnormal_flag(value, range, explicit_flag=).

Resolution order: an explicit lab flag wins first (H/HIGH, L/LOW,

C/CRIT/CRITICAL, HH/LL → critical, N/NORMAL); an unknown explicit flag

returns "unknown" instead of being silently ignored. With no explicit flag,

it compares the numeric value against the parsed bounds, respecting inclusive

vs. exclusive edges.

  1. Handle "unknown" explicitly. Non-numeric values, empty/unparseable

ranges, or unrecognized explicit flags yield "unknown". Treat it as

"needs review," not "normal."

  1. Attach the advisory. Surface LAB_FLAG_ADVISORY wherever derived flags

are shown — derived flags are heuristic and do not replace the originating

laboratory's own diagnostic flagging.

Hand-off to / from OpenMed

entities give you the value text, unit, and often the reference range; this

skill turns them into structured flags. Parse the numeric value out of the

entity surface before calling derive_abnormal_flag.

derive_abnormal_flag, ReferenceRange, AbnormalFlag, LAB_FLAG_ADVISORY`.

flag becomes a FHIR Observation.interpretation code (HL7 v3

ObservationInterpretation: H, L, HH, LL, N). Ground the LOINC code and

UCUM unit out-of-process; OpenMed emits the flag, not the terminology binding.

Edge cases & gotchas

entirely. If the value and the range are in different units (mg/dL vs mmol/L),

the flag is wrong. Normalize units before calling, or only compare value

and range that share a unit.

a value of exactly 5 flags high. parse_reference_range records

high_inclusive=False for < and True for <= — respect it.

high. "critical" comes from the lab's explicit flag (C, HH, LL); the

helpers do not infer critical thresholds beyond the reference range.

"unknown" from derive_abnormal_flag, not "normal". Don't treat unknown as

in-range.

a diagnosis. Always carry LAB_FLAG_ADVISORY.

Standards & references

https://loinc.org/

https://ucum.org/

https://terminology.hl7.org/CodeSystem-v3-ObservationInterpretation.html

https://hl7.org/fhir/R4/observation.html

Use this skill with your AI agent: Open on Skill Issue to copy, download, or add to your library. Works with Claude, ChatGPT, Gemini, Cursor, Windsurf and more.