Tuning incremental sync config
A sync's configuration lives on the ExternalDataSchema and can be changed any time via
external-data-schemas-partial-update. Most changes are non-destructive (take effect on the next sync), but a few
(switching sync_type, changing primary keys) require careful handling to avoid corrupting the synced data.
When to use this skill
- The user wants to change how an already-connected table is synced
- A diagnosis flagged the incremental field or primary key as wrong
- The table is syncing too often / not often enough
- Switching an incremental table to CDC (or vice versa)
- The source table was changed on the other side (new columns, dropped columns) and the sync config needs to catch up
If the user is setting up a brand-new source, use setting-up-a-data-warehouse-source instead — configuration is
chosen at creation time there.
Available tools
| Tool | Purpose |
| ------------------------------------------------------ | ------------------------------------------------------------------------- |
| external-data-schemas-retrieve | Current sync_type, incremental_field, PKs, sync_frequency |
| external-data-schemas-incremental-fields-create | Refresh candidate incremental fields from the live source |
| external-data-schemas-partial-update | Apply the config change |
| external-data-schemas-reload | Trigger a sync with the new config |
| external-data-schemas-resync | Wipe and re-import from scratch when the change invalidates existing data |
| external-data-schemas-delete-data | Drop the synced table while keeping the schema entry |
| external-data-sources-check-cdc-prerequisites-create | Pre-flight Postgres CDC (only when switching to/from CDC) |
| external-data-sources-webhook-info-retrieve | Current webhook state (when switching to/from sync_type=webhook) |
| external-data-sources-create-webhook-create | Register a webhook after switching a schema to sync_type=webhook |
| external-data-sources-update-webhook-inputs-create | Rotate a webhook signing secret |
| external-data-sources-delete-webhook-create | Unregister webhook when switching schemas off sync_type=webhook |
The fields you can tune
From the partial-update endpoint:
| Field | Values | Notes |
| ------------------------ | ---------------------------------------------------------------------------------------- | ------------------------------------------------------------------ |
| sync_type | full_refresh, incremental, append, cdc, webhook | Source must support the target type — check via incremental-fields |
| incremental_field | Column name from the source | Must appear in incremental_fields list for the schema |
| incremental_field_type | datetime, date, timestamp, integer, numeric, objectid | Must match the column's real type |
| primary_key_columns | Array of column names | Required for CDC. Used for upsert dedup on incremental |
| cdc_table_mode | consolidated, cdc_only, both | Only meaningful when sync_type=cdc |
| sync_frequency | 5min, 15min, 30min, 1hour, 6hour, 12hour, 24hour, 7day, 30day, never | How often the table syncs. CDC: how often changes load, 7day max |
| sync_time_of_day | HH:MM:SS | When sync_frequency is daily/weekly-scale |
| should_sync | true / false | Pause the schema without deleting it |
Workflow
Step 1 — Read the current config
Always start with external-data-schemas-retrieve({id}). Understanding the current state prevents mistakes like
"fixing" an incremental_field that's actually correct.
Note:
- Current
sync_type,incremental_field,incremental_field_type,primary_key_columns - Current
status(don't tune a schema that's currentlyRunning— wait or cancel first) last_synced_at(so you can tell if the next sync worked)latest_errorif present (the error often tells you exactly what to change)
Step 2 — If changing sync_type or incremental_field, refresh candidates
Call external-data-schemas-incremental-fields-create({id}). Even though the operation name says "create", it
re-reads the source and returns the current candidate fields — use it to confirm the field you want to set actually
exists on the source and which sync types are now available for this table.
The response:
{
"incremental_fields": [{"field": "updated_at", "type": "datetime", ...}, ...],
"incremental_available": true,
"append_available": true,
"cdc_available": true,
"full_refresh_available": true,
"detected_primary_keys": ["id"],
"available_columns": [...]
}
If your target incremental_field isn't in the list, tell the user — they need to either pick a different field or
change the source table to add one.
Step 3 — Apply the change
Call external-data-schemas-partial-update({id}, {...changed fields}).
Only send the fields that are actually changing. Partial update means unspecified fields stay as they are.
Examples:
// Switch from full_refresh to incremental
{
"sync_type": "incremental",
"incremental_field": "updated_at",
"incremental_field_type": "datetime"
}
// Change sync frequency to hourly
{"sync_frequency": "1hour"}
// Fix wrong PK on a CDC table (an incremental table with synced data needs delete-data first, see below)
{"primary_key_columns": ["tenant_id", "order_id"]}
// Pause a schema
{"should_sync": false}
Step 4 — Decide whether existing data is still valid
This is the step that's easy to get wrong. Some config changes invalidate the synced data; others don't.
Changes that DON'T invalidate existing data:
sync_frequency,sync_time_of_day— scheduling onlyshould_sync— on/offcdc_table_modein most cases — next sync will start writing to the new shape, but historical consolidated rows
stay valid
- Switching between
incrementalandfull_refreshwith the sameincremental_field— next sync just re-runs
fresh
- Switching to or from
sync_type: "webhook"— the synced data stays valid; only the ingestion path changes.
Remember to register or unregister the webhook (see sections below) alongside the sync_type change.
Changes that MAY invalidate existing data and need a resync:
- Changing
incremental_fieldto a different column — see
Changing the incremental field for what the update does to the cursor and when
a resync is needed.
- Changing
primary_key_columns— existing rows were merged on the old key, so they may be deduplicated incorrectly
against the new one. On an incremental table that already has a key and synced data, partial-update refuses
the change, so the order is different — see
Changing primary keys on an incremental table.
- Switching from
full_refreshtoappend— the existing rows don't have the version-history shape that append
expects.
- Switching from
appendtofull_refresh— opposite problem; you'll end up with duplicate historical versions. - Switching to/from
cdc— the table shape changes fundamentally.
When the change invalidates data, warn the user that the next step deletes the synced data before you do anything.
Then use one of these flows:
- Update, then resync:
external-data-schemas-partial-updatewith the new config, then
external-data-schemas-resync to wipe and re-import under the new config. This does not work for a primary key
change on an incremental table, because partial-update refuses that change while the synced data exists.
- Delete, update, reload:
external-data-schemas-delete-data→external-data-schemas-partial-updatewith the new
config and should_sync: true → external-data-schemas-reload. delete-data turns syncing off, so the update
must turn it on again, or the schedule stays paused after the reload. This flow works for every change, including
an incremental primary key.
Step 5 — Trigger and confirm
For non-destructive changes, call external-data-schemas-reload({id}) to pick up the new config immediately rather
than waiting for the schedule.
Wait a moment, then external-data-schemas-retrieve({id}) to confirm status = Running then Completed. Report
last_synced_at and any new latest_error.
Specific common changes
Switching full_refresh → incremental
incremental-fields-createto confirm the desired field exists andincremental_available: true.partial-update:{sync_type: "incremental", incremental_field, incremental_field_type}.- No data wipe needed — next sync just switches strategy. If the source is growing fast, the next incremental sync
is the cheap one.
Switching incremental → cdc (Postgres only)
- Run
external-data-sources-check-cdc-prerequisites-createon the parent source. Only proceed ifvalid: true. incremental-fields-createto confirmcdc_available: trueand seedetected_primary_keys.partial-update:{sync_type: "cdc", primary_key_columns: [...], cdc_table_mode: "consolidated"}.- Resync required — CDC tables have a different shape. Trigger
external-data-schemas-resyncafter the update.
Warn the user this wipes existing data.
Changing the incremental field
When partial-update sets a different incremental_field on an incremental or append table that has synced data,
the API sets the cursor from the synced table. It does not keep the old field's high-water mark:
- The synced table has values in the new column. The cursor becomes the largest value of the new column in the
synced table. The next sync reads only rows above that value. Use reload (or wait for the schedule).
- The synced table has no values in the new column (the column is new, or it is empty). The API clears the
cursor and starts a full re-import itself. Do not call reload or resync after it — a sync is already starting.
- The table has no synced data yet. The first sync reads all rows, so no extra step is needed.
The first case can miss rows. A source row whose new-column value is below the cursor does not sync again, even if
the synced copy is out of date. For example, the old field was id and the new field is updated_at. A row that
changed after its first sync, but has an updated_at below the largest synced updated_at, keeps its old version.
If the two columns do not move together, tell the user that rows can be missing and offer a resync. A resync deletes
the synced data, so warn the user first.
Fixing a stale incremental field after schema drift
Source dropped the updated_at column. Sync has been failing with "column does not exist".
incremental-fields-createto see what fields remain.- Pick a replacement (or switch to
full_refreshif none are suitable). partial-updatewith the new field + type (or new sync_type).- Read Changing the incremental field to choose the next step. If the replacement
column already has values in the synced table, the cursor comes from it: reload to retry, and offer a resync
if rows can be missing. If the column has no synced values, the update already started a full re-import, so do
not reload. If you switched to full_refresh, reload to retry.
Changing primary keys on an incremental table
When the table already has a primary key and synced data, partial-update refuses a new key with "Primary key
cannot be changed after data has been synced". The synced data must go first. Setting the first key on a table that
has none is allowed with a plain partial-update.
Before you call any tool, warn the user: this deletes the synced table, and the next sync imports every row again.
Get their confirmation. Then:
external-data-schemas-delete-data— drops the synced table and turns syncing off.external-data-schemas-partial-updatewith the new key andshould_sync: true, for example
{"primary_key_columns": ["tenant_id", "order_id"], "should_sync": true}.
external-data-schemas-reload— imports every row under the new key.
Changing primary keys on a CDC table
This flow is for sync_type: "cdc" only. For an incremental table, see
Changing primary keys on an incremental table.
partial-update:{primary_key_columns: [...]}.- Resync required — existing CDC tombstones and upsert keys won't match the new PK definition, leading to row
duplication or missed updates.
resync, warn the user.
Changing sync_frequency
partial-update:{sync_frequency: "1hour"}.- No reload needed — the next scheduled sync picks up the new cadence. Or reload manually if the user wants to
confirm nothing broke.
Switching a schema to `sync_type: "webhook"`
Only works for sources that implement WebhookSource (today: Stripe) and tables where supports_webhooks: true
from incremental-fields-create.
incremental-fields-createto confirmsupports_webhooks: truefor the table.partial-update:{sync_type: "webhook"}.- If the source doesn't already have a webhook registered (check with
webhook-info-retrieve), call
external-data-sources-create-webhook-create({id}) to register it.
- No resync required — the schema's existing bulk-synced data stays, and the webhook becomes the primary ingestion
path once the next reconciliation finishes.
- Keep
sync_frequencyset (e.g.24hour) — it acts as a safety-net reconciliation in case any webhook delivery
is missed.
Switching off `sync_type: "webhook"`
partial-update:{sync_type: "incremental"}(or whatever bulk type is appropriate) with the required
incremental_field + incremental_field_type.
- If no other schemas on the source are still using
sync_type: "webhook", call
external-data-sources-delete-webhook-create({id}) to unregister. Leaving an orphaned webhook
registered on the source side just means events will be received and dropped — not harmful, but messy.
- If other schemas on the source are still on webhook, leave the webhook registered — it's shared across all
webhook-type schemas on the source.
Rotating a webhook signing secret
The source's signing secret (e.g. Stripe's whsec_...) was rotated, and payloads are now failing signature
verification.
- Grab the new secret from the source's dashboard.
external-data-sources-update-webhook-inputs-create({id}, {inputs: {signing_secret: "whsec_..."}}).- No reload needed — the next inbound webhook payload will verify against the new secret.
Pausing a schema
partial-update:{should_sync: false}. Schema stops syncing but stays configured.- To resume later:
partial-update:{should_sync: true}, thenreloadfor an immediate run.
Important notes
- Read before you write. Always retrieve the current config first.
partial-updatedoesn't complain if you set a
field to the value it already had, but you might be about to change something you didn't realize was already set.
- Not every sync_type is available on every schema. The
incremental-fields-createresponse tells you what's
available _right now_, which can be different from what was available at creation (e.g. CDC may have been
enabled for the team since).
- Wipe when the shape changes. Switching sync strategy often changes the physical table. If you don't resync,
you'll be mixing row shapes and queries will return garbage.
- CDC needs prerequisites. Never switch to
sync_type: "cdc"without runningcheck-cdc-prerequisites-create
first. The sync will just fail immediately.
- Don't touch a Running schema. If the schema is currently running, either wait for it to finish or
external-data-schemas-cancel before applying the change. Updating config mid-sync can leave the incremental
high-water mark inconsistent.
- Sync frequency is cheap to change. Encourage experimentation there. Sync_type and incremental_field are
expensive to change — encourage care.
- Webhooks are registered at the source level, not the schema level. Multiple webhook-type schemas on the same
source share one webhook registration. Only delete the webhook when the _last_ webhook-type schema on that
source is being switched away, otherwise other schemas stop receiving pushes.