Lsp dead code

From blackwell-systems/agent-lsp · View interactive version

Lsp dead code is an AI agent skill from the GitHub repository blackwell-systems/agent-lsp. Enumerate exported symbols in a file and surface those with zero references across the workspace. Use when auditing for dead code, cleaning up APIs, or checking which exports are safe to remove.

How to use this skill

Skill file

Requires the agent-lsp MCP server.

lsp-dead-code

Audit an exported symbol list for zero-reference candidates. Calls

list_symbols to enumerate symbols, then checks each exported

symbol with find_references to find callers. Produces a classified report.

When to Use

Use this skill when you want to identify dead code in a file — exported

symbols that are defined but never called anywhere in the workspace. Common

use cases:

Important: This skill surfaces candidates. Always review results

manually before deleting anything. See the Caveats section below.

What counts as "exported"

| Language | Exported means... |

|------------|------------------------------------------------------------------------|

| Go | Identifier starts with an uppercase letter (e.g. MyFunc, MyType) |

| TypeScript | Has export keyword; or is a public class member (no private) |

| Python | Not prefixed with _; or explicitly listed in __all__ |

| Java/C# | Has public or protected visibility modifier |

| Rust | Has pub keyword |

Prerequisites

If LSP is not yet initialized, call mcp__agent-lsp__start_lsp with the

workspace root first:

mcp__agent-lsp__start_lsp({ "root_dir": "/your/workspace" })

agent-lsp supports auto-inference from file paths, so explicit start is

only required when switching workspaces or on a cold session.

Step 0 — Verify indexing is complete (mandatory)

Do not skip this step. An under-indexed workspace returns [] for

symbols that ARE referenced, producing false dead-code candidates.

Pick one symbol you know is actively used (e.g. the primary constructor,

a widely-called utility function). Call find_references on it:

mcp__agent-lsp__find_references({
  "file_path": "/abs/path/to/file.go",
  "line": <known-active symbol line>,
  "column": <known-active symbol column>,
  "include_declaration": false
})

If this returns []: the workspace is not indexed. Wait 3–5 seconds

and retry. Do not proceed until a known-active symbol returns ≥1 reference.

If it never returns results after 15 seconds, restart the LSP server with

mcp__agent-lsp__restart_lsp_server and re-open the target file.

Step 1 — Open the file and enumerate symbols

Open the file so the language server tracks it, then fetch all symbols:

mcp__agent-lsp__open_document({ "file_path": "/abs/path/to/file.go" })

mcp__agent-lsp__list_symbols({ "file_path": "/abs/path/to/file.go" })

Collect the full symbol list. Filter to exported symbols only using the

language-appropriate rule from the table above.

Coordinate note: list_symbols returns 1-based coordinates.

Pass selectionRange.start.line and selectionRange.start.character

directly to find_references — no conversion needed.

"no identifier found" error: This means the column points to whitespace

or a keyword rather than the identifier name. This happens with methods

whose receiver prefix shifts the name rightward (e.g. func (c *Client) MethodName

— the name starts at column 21, not column 1). Fix: grep the declaration

line for the symbol name to find its exact column:

grep -n "MethodName" file.go
# count characters to find the 1-based column of the name

Then retry find_references with the corrected column.

Step 2 — Check references for each exported symbol

For each exported symbol, call find_references with

include_declaration: false so the definition site itself is excluded

from the count. A count of 0 means no callers, not no occurrences.

mcp__agent-lsp__find_references({
  "file_path": "/abs/path/to/file.go",
  "line": <selectionRange.start.line>,
  "column": <selectionRange.start.character>,
  "include_declaration": false
})

Record the result for each symbol:

{ symbol_name, kind, line, reference_count, locations[] }

Batching note: For files with many exported symbols (>20), process in

batches of 5–10 to avoid overwhelming the LSP server.

Zero-reference cross-check (required before classifying as dead):

When find_references returns [] for a symbol that looks foundational

(a handler, a constructor, a type used as a field), do not trust LSP alone.

LSP can miss references made through value-passing, interface satisfaction,

or function registration patterns (e.g. server.AddResource(HandleFoo)).

Before classifying as dead, run a text search in the primary wiring files:

grep -r "SymbolName" main.go server.go cmd/ internal/

If grep finds the name in a registration or assignment context, the symbol

is active — LSP just couldn't resolve the indirect reference. Update your

classification accordingly.

Step 3 — Classify and report

Classify each exported symbol by reference count:

For test-only references: if all locations are in _test.go files (Go) or

files named *.test.* / *.spec.*, mark the symbol as "test-only" in

the report rather than "zero-reference".

Produce the Dead Code Report using the format in

references/patterns.md.

Caveats

The following cases produce zero LSP references even though the symbol IS

used at runtime. Do not delete any zero-reference candidate without

manual review:

  1. Incomplete indexing. find_references only searches files open or

indexed by the language server. If the workspace is partially indexed,

results may be incomplete. The Step 0 warm-up check catches this.

  1. Registration patterns. Symbols passed as values to registration

functions (e.g. server.AddTool(HandleFoo), http.HandleFunc("/", handler))

appear as zero LSP references from the definition site because gopls

tracks the call to the registrar, not the handler name. Always grep

wiring files for zero-reference handlers before classifying as dead.

  1. Reflection and dynamic dispatch. Symbols used via reflection

(reflect.TypeOf in Go, Class.forName in Java) or dynamic dispatch

have no static call sites visible to the LSP.

  1. //go:linkname and assembly. Go symbols linked via //go:linkname

or referenced from assembly files will show zero LSP references.

  1. Library public API. Exported symbols called from external packages

not present in the workspace will show zero references even if

consumers exist.

  1. Declaration excluded from count. The definition site is not counted

(include_declaration: false). A count of 0 means no callers found,

not that the symbol never appears in the source tree.

  1. Always review before deleting. Zero LSP references is a signal to

investigate, not a guarantee the symbol is unused.

Step 4 — Next steps

After generating the report:

on the symbol to confirm. If lsp-impact also finds zero references, it

is safe to consider for removal. Still check the Caveats section above.

the report. These may be candidates for removal if the tests themselves

are redundant, but should not be deleted without reviewing whether the

tests serve a documentation or contract purpose.

active but lightly used. Do not remove without checking whether they are

part of a committed public API.

Step 5 — Optional cleanup with `safe_delete_symbol`

After reviewing the dead code report and confirming candidates with the user,

you may offer to remove confirmed zero-reference symbols using safe_delete_symbol:

mcp__agent-lsp__safe_delete_symbol({
  "file_path": "/abs/path/to/file.go",
  "symbol_path": "DeadFunction"
})

This tool performs its own reference check before deleting. If any references

exist (even ones missed in the initial scan), the deletion is refused.

Requirements before using this step:

  1. The user has explicitly confirmed they want the symbol removed.
  2. The symbol was classified as a confirmed dead candidate (zero LSP + zero grep references).
  3. You have reviewed the Caveats section above and communicated relevant risks.

Do NOT auto-delete symbols without user confirmation. Present the dead code

report first, let the user select which symbols to remove, then execute

safe_delete_symbol for each approved removal.

Use this skill with your AI agent: Open on Skill Issue to copy, download, or add to your library. Works with Claude, ChatGPT, Gemini, Cursor, Windsurf and more.