Membrane ro fundamentals

From claude-dev-suite/claude-dev-suite · View interactive version

Membrane ro fundamentals is an AI agent skill from the GitHub repository claude-dev-suite/claude-dev-suite. Reverse Osmosis (RO) and Electrodeionization (EDI) process fundamentals — formulas (recovery, rejection, NDP, osmotic pressure, TCF, NPF/NSP), authoritative standards reference (ASTM/ISO/USP/Ph.Eur./WHO/EN), vendor design windows (DuPont, Hydranautics, Toray, Suez, LANXESS), water chemistry, EDI qui

How to use this skill

Skill file

RO & EDI Process Fundamentals

Reference for water-treatment expertise: formulas, normative standards, vendor design envelopes, water chemistry, and bilingual terminology.

Convention markers used throughout the membrane skills:


§1 — RO Process Fundamentals

All formulas in SI (LMH, bar, °C) with US field-unit (GFD, psi, °F) variant noted. Variables: Qf feed flow, Qp permeate, Qc concentrate, Cf/Cp/Cc concentrations, Am membrane area, T temperature.

1.1 Recovery (Water Recovery / Recupero)

Y = Qp / Qf

Typical ranges (vendor-dependent):

Source: ASTM D6161-19; DuPont 45-D01504; Hydranautics TSB 107.

1.2 Concentration Factor (CF)

CF_ideal = 1 / (1 - Y)                          # for R = 1
CF_real  = (1 - Y·(1 - R)) / (1 - Y)            # for rejection R

At Y = 0.75 and R = 0.99: CF_ideal = 4.00, CF_real ≈ 3.97 (error < 1 %), so the ideal form is acceptable for SWRO/BWRO design.

Source: DuPont 45-D01591 (Design Equations).

1.3 Salt Rejection — three definitions

| Variant | Symbol | Formula | When used |

|---|---|---|---|

| Observed (apparent) | R_obs | 1 − Cp/Cf | What instruments measure |

| System (log-mean) | R_sys | 1 − Cp / mean(Cf, Cc) | Standard reporting |

| Intrinsic (at wall) | R_int | 1 − Cp / (β · mean(Cf, Cc)) | Corrected for polarization |

Concentration polarization factor:

β = Cwall / Cbulk = exp(0.7 · Y_element)

where Y_element is per-element recovery. FilmTec design limit: β ≤ 1.2 → Y_element ≤ 18 % (the 18 % per-element rule). Hydranautics is more conservative at 15 %.

⚠️ A code path that confuses R_obs with R_sys will under-report rejection by 5–15 % at high recovery. Always specify which definition the calculator returns.

Sources: DuPont 45-D01591; Hydranautics Terms and Equations of RO.

1.4 Permeate Flux (Jw)

Jw = A · NDP · TCF · FF                          # vendor model
Jw = Qp / Am                                     # operational

A = water permeability (LMH/bar), FF = fouling factor (0.85 design / 0.70 EOL).

Unit conversion: 1 GFD = 1.6987 LMH (≈ 1.70).

Typical design flux windows (vendor consensus):

| Application | GFD | LMH |

|---|---|---|

| SWRO open intake (SDI 3–5) | 7–9 | 12–15 |

| SWRO beach well (SDI < 2) | 8–10 | 14–17 |

| BWRO well (SDI < 3) | 14–18 | 24–30 |

| BWRO surface (SDI 3–5) | 10–14 | 17–24 |

| RO permeate / 2nd pass | 20–30 | 34–51 |

⚠️ A hard-coded flux_max = 25 LMH threshold is incorrect for SWRO (well above limit) and conservative for BWRO well (well below limit). Threshold must be water-source-aware.

Sources: DuPont 45-D01695 Rev 14 (Feb 2026); Hydranautics TSB 105; AMTA Optimum Flux Rates.

1.5 Salt Flux (Js)

Js = B · (mean(Cf,Cc) − Cp) ≈ B · mean(Cf,Cc)
Cp = Js / Jw                                     # key inverse relation

B is temperature-dependent but pressure-independent (unlike A). At cold feed temperature, Jw drops while Js is relatively unchanged → Cp rises → permeate quality degrades. Cold-water permeate TDS spikes are explained by this relation.

Source: DuPont 45-D01591; Hydranautics Terms and Equations.

1.6 Net Driving Pressure (NDP)

NDP = (Pf + Pc)/2 − Pp − (πw − πp)
    = mean_feed_pressure − permeate_pressure − osmotic_differential_at_wall

with πw = β · π_mean(Cf,Cc) (osmotic pressure at membrane wall, corrected for polarization).

Source: ASTM D4516-19a §6; DuPont 45-D01591.

1.7 Osmotic Pressure (π)

Rigorous Van't Hoff:

π = i · M · R · T                                # i ≈ 1.8–2.0 for NaCl
                                                 # R = 0.08314 L·bar/(mol·K)
                                                 # T in Kelvin

Engineering shortcut (industry standard at 25 °C):

π [psi] ≈ 0.0085 · TDS [ppm]
π [bar] ≈ 0.000586 · TDS [ppm]

Shortcut accuracy:

Seawater rule of thumb: 35 000 ppm → π ≈ 25–28 bar bulk; ≈ 32–35 bar at wall with β = 1.15.

⚠️ A formula returning π ≈ 8 bar for seawater under-estimates by 3–4× — verify constants and unit handling. The correct order of magnitude for seawater is 25–35 bar.

Source: Pitzer comparison (Tandfonline 2019); Stark-Water RO Working Principle Guide; FilmTec 45-D01591.

1.8 Temperature Correction Factor (TCF)

ASTM D4516-19a normalizes flux to a 25 °C reference. General exponential form:

TCF = exp[ Ke · (1/298 − 1/(273 + T)) ]

Membrane-chemistry constants (Hydranautics TSB 107.28 Apr 2025; FilmTec 45-D01616 Rev 10 Feb 2022):

| Membrane type | Ke | Regime |

|---|---|---|

| FilmTec BW30 / SW30 (T ≥ 25 °C) | 3 020 | Hot |

| FilmTec BW30 / SW30 (T < 25 °C) | 2 640 | Cold (flux drops faster) |

| Hydranautics CPA / ESPA | 2 500–3 480 | Element-specific (TSB 107) |

| Hydranautics SWC seawater | ~3 020 | |

Practitioner shortcut: TCF ≈ 1.03 per °C around 25 °C; doubles every ~25 °C rise.

1.9 Normalized Permeate Flow (NPF) — ASTM D4516-19a §7

NPF = Qp_meas · (NDP_std / NDP_actual) · (TCF_std / TCF_actual)

Action thresholds (industry consensus):

⚠️ NPF cannot be computed without a baseline. Code paths declaring NPF as a field but never populating it because calculate_kpis() receives no baseline are silently broken.

1.10 Normalized Salt Passage (NSP) — ASTM D4516-19a §8

NSP = SP_meas · (mean_C_std / mean_C_actual) · (EPF_actual / EPF_std) · (STCF_std / STCF_actual)

where SP = Cp / mean(Cf, Cc) and STCF is the salt-passage temperature factor (different exponent constant: Ks ≈ 2 200).

Action threshold: NSP rise 15 % → integrity check via ASTM D6908 VDT or ASTM D3923 leak test.

1.11 Element / Vessel / Stage / Train Hierarchy

Train (skid)
└── Stage 1                  ┐ array typically 2:1 or 3:2:1
    ├── Pressure Vessel       │
    │   ├── Element 1         │ standard 8"×40" or 4"×40"
    │   ├── Element 2         │ 6–8 elements per vessel
    │   └── …                 │ typical per-vessel Y = 8–15 %
    └── Stage 2 / 3            reuses concentrate as feed

Per-stage recovery rule of thumb:

Per-element max: Y_element ≤ 18 % (FilmTec) or ≤ 15 % (Hydranautics).


§2 — Authoritative Standards Reference

| Standard | Title | Edition | When to invoke |

|---|---|---|---|

| ASTM D4516-19a | Standardizing RO Performance Data | 2019 | Normalize NPF, NSP — any commissioning, surveillance, warranty claim |

| ASTM D3923 | Detecting Leaks in RO and NF Devices | 2023 (also 2018) | New-element acceptance; suspected O-ring / glue-line failure |

| ASTM D3739-19 | Calculation of the Langelier Saturation Index for RO | 2019 | CaCO₃ scaling prediction; valid for concentrate TDS 10–10 000 mg/L |

| ASTM D4582 | Stiff & Davis Stability Index | current | CaCO₃ scaling at TDS > 10 000 mg/L |

| ASTM D4194-23 | Operating Characteristics of RO and NF Devices | 2023 | Short-term (< 24 h) factory or commissioning test — not for plant design |

| ASTM D4195 | Water Analysis for RO/NF Application | 2014 (withdrawn 2023, still authoritative for scope) | Feedwater characterization scope |

| ASTM D6161-19 | Terminology for Membrane Separation | 2019 | Definitive glossary; cite to resolve term disputes |

| ASTM D4189-23 | Silt Density Index (SDI) | 2023 | Pretreatment performance benchmark (30 psi, 0.45 µm, 15 min default) |

| ASTM D6908 | Integrity Testing of Water Filtration Membrane Systems | 2025 / 2017 | VDT for RO/NF; PDT for UF/MF |

| ISO 16075-1..4 | Treated Wastewater Use for Irrigation | 2020 / 2021 | Reuse projects; -2 defines water-quality classes A–D |

| WHO GDWQ 4th ed. | Guidelines for Drinking-water Quality (+ 1st & 2nd Addenda) | 2022 | Health-based limits: As 10 µg/L, B 2 400 µg/L, F 1.5 mg/L, NO₃ 50 mg/L |

| USP <645> | Water Conductivity | current | Stage 1 limit 1.3 µS/cm @ 25 °C (uncompensated, in-line) for Purified Water |

| USP <643> | Total Organic Carbon | current | 500 ppb limit for PW and WFI; system suitability with sucrose + 1,4-benzoquinone |

| Ph. Eur. 0008 | Purified Water (Aqua purificata) | current | Equivalent to USP PW; conductivity ≤ 4.3 µS/cm @ 20 °C, TOC ≤ 0.5 mg/L |

| Ph. Eur. 0169 | Water for Injection | Effective 1 April 2017 (Suppl. 9.1) | Allows non-distillation WFI via RO + EDI/UF/NF (note: no 2026 enforcement deadline for this monograph) |

| Ph. Eur. ch. 2.2.44 | TOC in Water for Pharmaceutical Use | Effective 1 July 2026 | New harmonized USP/Ph.Eur. method; CRS replaces sucrose/1,4-BQ; updates to "Water" terminology |

| EN 1717:2025 | Protection of Potable Water from Backflow | 2025 | Fluid categories 1–5; air gaps for RO permeate re-entering potable mains |

| EN 12952-12 | Boiler-feed and Boiler-water Quality | current | Tiered limits keyed to drum pressure class |

| 21 CFR Part 11 | Electronic Records & Signatures (US FDA) | — | Data integrity for pharma roadmap |

| EU Annex 11 | Computerised Systems (EudraLex Vol. 4) | — | Risk-based validation; ALCOA+ |

| SEMI F63 | Ultrapure Water for Semiconductor Processing | 2021 | ≥ 18.2 MΩ·cm, TOC < 1 ppb, SiO₂ < 0.3 ppb |

⚠️ ASTM D4195 is withdrawn (2023) but still cited as authoritative for scope — flag this explicitly when referencing.

⚠️ Ph. Eur. 0169 has no "mandatory 2026-07" deadline. The non-distillation WFI revision took effect 1 April 2017. The 2026-07 date belongs to chapter 2.2.44 (TOC harmonization), which is a different normative artifact.


§3 — Vendor Design Guides

3.1 DuPont FilmTec

Key documents: 45-D01504 (master Tech Manual); 45-D01580 (System Design); 45-D01588 (4"/midsize); 45-D01695 Rev 14 Feb 2026 (8" Design Guidelines, current); 45-D01591 (Design Equations); 45-D01616 (Plant Performance Normalization).

| Family | Use | Test conditions | Salt rejection |

|---|---|---|---|

| SW30HR / SW30HRLE-440i | Seawater | 32 000 ppm NaCl, 800 psi, 25 °C, 8 % | 99.7–99.8 % |

| BW30-400 / BW30HR-440i | Brackish | 2 000 ppm NaCl, 225 psi, 25 °C, 15 % | 99.5 % |

| LE / XLE / Eco | Low-energy brackish | 500–2 000 ppm, 100–150 psi | 99.0–99.4 % |

3.2 Hydranautics (Nitto)

TSB index (publicly available at membranes.com):

| TSB | Topic |

|---|---|

| 100 | Foulant identification |

| 105 | Storage and preservation |

| 107.28 (Apr 2025) | Foulants & cleaning procedures; TCF constants |

| 108 | Chlorination / dechlorination |

| 110 | Operating limits & biocides |

| 111 | Biofouling control |

| 113 | ESPA/CPA/SWC product specs; oxidation |

| 124 | Integrity and VDT |

| 207 | Standardization (Hydranautics version of D4516) |

| 414 | Caustic / acid CIP procedure |

| Family | Type | Notes |

|---|---|---|

| SWC4 / SWC5 / SWC6 | Seawater | 99.8 % rejection; ~92 % B rejection @ pH 8 |

| CPA3 / CPA5-LD / CPA7 | Brackish high rejection | Low-ΔP variants for fouling |

| ESPA1 / ESPA2 / ESPA4 | Energy saving | Low pressure, tap/municipal |

| PRO-XS / PRO-XR | Industrial | Lifecycle / robustness |

3.3 Toray, Suez/Veolia, LANXESS

| Vendor | Series | Notes |

|---|---|---|

| Toray | TM820V/M (seawater), TMG20D (brackish low-energy), TM720D (tap) | TM820V-400: 99.8 % @ 32 000 ppm, 800 psi |

| Suez/Veolia | AG / AK / AD / AE; GenGard antiscalant | AG8040F: ~11 000 GPD, 99.5 % |

| LANXESS | Lewabrane B400 HR / B440 HR / ULP / ASD | B400 HR: 37.9 m³/d, 99.7 % rejection |

| LG Chem | NanoH2O | Variable operating windows |

3.4 Universal vendor envelope (all polyamide TFC)

| Parameter | Limit | Damage mode if exceeded |

|---|---|---|

| Max pressure SWRO | 83 bar (1 200 psi) | Compaction; glue-line failure |

| Max pressure BWRO | 41 bar (600 psi) | Same |

| Max ΔP per element | 1 bar (15 psi) | Telescoping |

| Max ΔP per vessel | 3.5 bar (50 psi) | Same |

| Max temperature | 45 °C continuous; 35 °C above pH 10 | Compaction, hydrolysis |

| pH range continuous | 2–11 | Hydrolysis outside |

| pH range CIP | 1–13 (short-term) | |

| Free chlorine | < 0.1 ppm (effectively zero) | Oxidative attack |

| Other oxidants (O₃, MnO₄⁻, peroxide) | Not tolerated | Same |

| Max SDI₁₅ feed | 5 (3 preferred) | Colloidal fouling |

| Max turbidity feed | 1 NTU | |


§4 — Water Chemistry Essentials

4.1 Conductivity / TDS quick reference (25 °C)

| Water type | TDS (mg/L) | Conductivity (µS/cm) |

|---|---|---|

| Seawater (open ocean) | 32 000–38 000 | 50 000–58 000 |

| Mediterranean / Red Sea | 38 000–43 000 | 58 000–65 000 |

| High brackish | 5 000–15 000 | 7 000–22 000 |

| Low brackish / well | 1 000–5 000 | 1 500–7 500 |

| Tap (municipal) | 100–500 | 150–750 |

| 1st-pass RO permeate (SW feed) | 200–500 | 300–800 |

| 1st-pass RO permeate (BW feed) | 10–50 | 15–80 |

| 2nd-pass RO permeate | 1–5 | 1.5–8 |

| Mixed-bed DI / EDI product | < 0.1 | < 0.1 |

| USP PW limit (Stage 1) | — | ≤ 1.3 |

| 18.2 MΩ·cm UPW | < 0.06 | 0.055 (theoretical limit) |

Conversion rule (NaCl-dominated): TDS [ppm] ≈ 0.64 × κ [µS/cm] for brackish; 0.55–0.70 for seawater.

4.2 Typical seawater ion composition (mg/L)

| Ion | Atlantic | Mediterranean | Red Sea |

|---|---|---|---|

| Na⁺ | 10 800 | 12 700 | 13 500 |

| Cl⁻ | 19 400 | 22 900 | 24 100 |

| SO₄²⁻ | 2 700 | 3 200 | 3 400 |

| Mg²⁺ | 1 290 | 1 480 | 1 590 |

| Ca²⁺ | 410 | 470 | 510 |

| K⁺ | 390 | 470 | 500 |

| HCO₃⁻ | 142 | 150 | 165 |

| Br⁻ | 67 | 76 | 80 |

| Sr²⁺ | 8 | 9 | 13 |

| B (total) | 4.5 | 5.2 | 6.5 |

| TDS | 35 200 | 41 500 | 44 000 |

4.3 pH effects on rejection (pKa-driven)

| Species | pKa @ 25 °C | Practical impact |

|---|---|---|

| Boron (H₃BO₃ ⇌ B(OH)₄⁻) | 9.14–9.24 | 85–92 % @ pH 8 → > 98 % @ pH 10.5. Double-pass with high-pH 2nd pass is the industry standard for SWRO boron removal |

| Silica (H₄SiO₄ ⇌ H₃SiO₄⁻) | 9.84 | Higher pH → higher rejection but raises scaling risk |

| Ammonia (NH₄⁺ ⇌ NH₃) | 9.25 | Below pKa: 95 % rejection; above pKa: NH₃ passes (DW concern) |

| CO₂ / HCO₃⁻ / CO₃²⁻ | 6.35 / 10.33 | At pH < 7 dominated by CO₂ which passes freely; dose NaOH after RO to convert to HCO₃⁻ before EDI |

4.4 SDI interpretation (ASTM D4189-23)

| SDI₁₅ | Interpretation | Action |

|---|---|---|

| < 1 | Excellent | Years between fouling events |

| 1–3 | Acceptable | Months between CIP |

| 3–5 | Marginal | Frequent CIP likely; consider UF |

| > 5 | Unacceptable | UF / coagulation / multimedia required |

Caveat: SDI is filter-brand-dependent; Modified Fouling Index (MFI) is more rigorous.

4.5 Free chlorine / ORP

4.6 Scaling indices

LSI (Langelier) — for TDS < 10 000 mg/L (ASTM D3739-19):

LSI = pH_actual − pH_s
pH_s = (9.3 + A + B) − (C + D)
  A = f(TDS)
  B = f(T)
  C = f(Ca²⁺ hardness)
  D = f(alkalinity)

LSI > 0 → CaCO₃ scaling tendency. Target: LSI(concentrate) < 0 without antiscalant; < +1.8 with effective inhibitor; up to +2.5 with strong dosing.

S&DSI (Stiff & Davis) — for TDS > 10 000 mg/L (ASTM D4582):

S&DSI = pH − pK2 + pKs − p[Ca²⁺] − p[HCO₃⁻]

Same interpretation as LSI; targets typically < +1.0 with antiscalant.

⚠️ Saturation indices must be computed at the concentrate (last element), not feed — the concentrate is where supersaturation actually occurs.


§5 — EDI Quick Reference

5.1 EDI feed envelope

| Parameter | Target | Hard limit |

|---|---|---|

| Conductivity / FCE | < 30 µS/cm preferred | < 40 µS/cm |

| Total hardness (as CaCO₃) | < 1 ppm | < 2 ppm (softener required above) |

| Total CO₂ (CO₂ + HCO₃⁻ + CO₃²⁻) | < 5 ppm | < 10 ppm (NaOH dosing / degasser) |

| Silica (SiO₂) | < 0.5 ppm | < 1 ppm |

| TOC | < 0.5 ppm | < 1 ppm |

| Fe / Mn | < 0.01 ppm each | < 0.05 ppm |

| Free chlorine | < 0.02 ppm | (destroys resin) |

| Temperature | 10–40 °C standard; 60 °C HWS modules | 5–45 °C |

| Inlet pressure | ≤ 7 bar (100 psi) | mechanical limit |

5.2 EDI product targets by application

| Application | Conductivity | Resistivity | Standard |

|---|---|---|---|

| Pharma PW | ≤ 1.3 µS/cm @ 25 °C | ≥ 0.77 MΩ·cm | USP <645> Stage 1 |

| Pharma WFI | ≤ 1.3 µS/cm + TOC ≤ 0.5 ppm + endotoxin ≤ 0.25 EU/mL | — | Ph. Eur. 0169 / USP WFI |

| Power-plant UPW | 0.1–1 µS/cm | 1–10 MΩ·cm | ASME / EPRI |

| Semiconductor UPW | < 0.055 µS/cm | 18.18 MΩ·cm (theoretical) | SEMI F63 |

5.3 Feed Conductivity Equivalent (FCE)

The manufacturer-standard load metric for EDI sizing — combines conductivity with the ionic load contributed by weak acids when ionized inside the stack:

FCE [µS/cm] = κ + 2.79 · CO₂[ppm] + 1.94 · SiO₂[ppm]

where:

Target: FCE 1–5 µS/cm for two-pass RO + EDI to UPW; FCE ≤ 40 µS/cm is the EDI feed limit (stack-dependent 25–43).

⚠️ Coefficient note: some methodologies use 2.66 for CO₂; 2.79 is the SnowPure/E-Cell convention — pick one and be consistent.

💡 EDI alerts that compare against raw feed_conductivity miss CO₂/SiO₂ load and silently allow off-spec operation. Always compute FCE.


§6 — Bilingual IT/EN Glossary

6.1 Process KPIs

| EN | IT | Note |

|---|---|---|

| Recovery | Recupero (Y) | Fraction or %, never raw flow |

| Rejection | Reiezione (R) | Three flavors: observed / system / intrinsic |

| Salt passage (SP) | Passaggio salino | SP = 1 − R |

| Permeate flux | Flusso del permeato (Jw) | LMH (EU) / GFD (US) |

| Salt flux | Flusso salino (Js) | Sets Cp at given Jw |

| Net Driving Pressure (NDP) | Pressione netta motrice | Apply gauge pressures consistently |

| Concentration factor (CF) | Fattore di concentrazione | 1/(1−Y) shortcut |

| Specific energy consumption (SEC) | Consumo energetico specifico | kWh/m³ |

| Normalized permeate flow (NPF) | Portata permeato normalizzata | ASTM D4516 |

| Normalized salt passage (NSP) | Passaggio salino normalizzato | ASTM D4516 |

| Temperature correction factor (TCF) | Fattore di correzione temperatura | Exponential form, Ke per membrane |

| Concentration polarization (β) | Polarizzazione di concentrazione | Wall/bulk ratio |

| Differential pressure (ΔP) | Perdita di carico | Per element / vessel / stage |

6.2 Phenomena

| EN | IT |

|---|---|

| Fouling | Sporcamento / fouling |

| Scaling | Incrostazione |

| Biofouling | Bioincrostazione |

| Compaction | Compattazione |

| Concentration polarization | Polarizzazione di concentrazione |

| Breakthrough | Sfondamento / breakthrough |

| Hydrolysis | Idrolisi |

| Oxidation | Ossidazione |

| Telescoping | Telescopamento (anglicismo accettato) |

| Channeling | Channeling (anglicismo) |

6.3 Components

| EN | IT |

|---|---|

| Skid | Skid / pacchetto pre-assemblato |

| Train | Treno (impianto) |

| Element (membrane element) | Elemento (a membrana) |

| Pressure vessel (PV) | Recipiente in pressione |

| Stage | Stadio |

| Pass | Passaggio |

| Feed spacer | Spaziatore di feed |

| Permeate channel / carrier | Canale del permeato |

| Header / manifold | Collettore |

| Energy Recovery Device (ERD) | Recuperatore di energia (Pelton / PX / DWEER) |

| High-pressure pump (HPP) | Pompa di alta pressione |

| Booster pump | Pompa di rilancio |

| Antiscalant | Antincrostante / antiscalante |

| Dechlorinator (SMBS) | Dechlorante / metabisolfito di sodio |

| Cartridge filter | Filtro a cartuccia |

6.4 Operations

| EN | IT |

|---|---|

| CIP (Cleaning In Place) | Lavaggio in posto / CIP |

| Flushing | Lavaggio / flussaggio |

| Sanitization | Sanitizzazione |

| Standby / preservation | Conservazione / messa in standby |

| Set-point | Set-point / valore di consegna |

| Trip / shutdown | Arresto di emergenza |

| Commissioning | Messa in servizio |

| Performance test | Test di prestazione |

| Autopsy | Autopsia (membrana) |

| Ramp-up | Avviamento progressivo (≤ 0.7 bar/s) |

6.5 Regulatory

| EN | IT |

|---|---|

| Purified Water (PW) | Acqua purificata |

| Water For Injection (WFI) | Acqua per preparazioni iniettabili |

| Highly Purified Water (HPW) | Acqua altamente purificata (Ph. Eur. historical) |

| Drinking water | Acqua potabile / per consumo umano |

| Reclaimed water | Acqua riutilizzata / di riuso |

| Endotoxin | Endotossina (EU/mL; LAL test) |

| Bioburden | Carica microbica (CFU/mL) |

| Total Organic Carbon (TOC) | Carbonio organico totale |


Sources

Primary normative — ASTM D4516-19a, D6161-19, D4189-23, D3739-19, D4582, D3923, D4194-23, D6908; ISO 16075-1..4; USP <645>, <643>; Ph. Eur. 0008, 0169 (Suppl. 9.1 effective 2017-04-01), chapter 2.2.44 (effective 2026-07-01); WHO GDWQ 4th ed. (2022 + addenda); EN 1717:2025; EN 12952-12; 21 CFR Part 11; EU Annex 11; SEMI F63:2021.

Vendor manuals — DuPont FilmTec 45-D01504, 45-D01580, 45-D01588, 45-D01591, 45-D01616, 45-D01695 (Rev 14 Feb 2026); Hydranautics TSB 100, 105, 107.28 (Apr 2025), 108, 110, 111, 113, 124, 207, 414; Toray RO Brochure 2024; LANXESS Lewabrane datasheets; LG Chem NanoH2O.

Reference — Lenntech RO chemistry pages; Stark-Water RO Working Principle; Pitzer vs Van't Hoff comparison (Tandfonline 2019); EMA Q&A on non-distillation WFI; PharmOut on Ph. Eur. 0169 (2017); FDCELL on chapter 2.2.44 (2026-07).

Use this skill with your AI agent: Open on Skill Issue to copy, download, or add to your library. Works with Claude, ChatGPT, Gemini, Cursor, Windsurf and more.