Membrane pretreatment

From claude-dev-suite/claude-dev-suite · View interactive version

Membrane pretreatment is an AI agent skill from the GitHub repository claude-dev-suite/claude-dev-suite. RO/NF pretreatment chain — feed type architectures (SWRO open/beach well, BWRO well/surface, tertiary reuse), pretreatment KPI targets (SDI, turbidity, AOC, Fe/Mn, free Cl2), coagulation chemistry (FeCl3/PAC/alum dose math), antiscalant selection by scaling species, dechlorination (SBS stoichiometry

How to use this skill

Skill file

RO/NF Pretreatment

Reference for what feeds the membrane train, with KPI targets, chemistry, and instrumentation. The 80 % rule: most RO/NF/EDI problems originate upstream.

Convention markers:


§1 — Pretreatment Chain Overview

1.1 SWRO open intake

Sea intake (screen 5–25 mm)
  → Travelling band / drum screen (~1–3 mm)
  → In-line coagulation (FeCl3 0.5–5 mg/L as Fe) + flash mix (G ≈ 700–1000 s⁻¹, 30–60 s)
  → Flocculation tank (G ≈ 30–80 s⁻¹, 15–30 min) [optional with inline coag]
  → DAF (HABs/algae/oil) OR direct media filtration
  → Dual / Multimedia gravity filter (5–15 m/h) OR pressure MMF (15–25 m/h)
  → [Optional] UF 0.02 µm for SDI₁₅ ≤ 2
  → Cartridge filter 5 µm absolute (ΔP fresh < 0.3 bar; change at 1.0–1.5 bar)
  → Antiscalant injection
  → SBS dechlorination (only if Cl2 used pre-filter)
  → Acid dosing (H2SO4 or HCl) for LSI control
  → HPP → SWRO 1st pass

1.2 SWRO beach well (subsurface intake)

Beach well / infiltration gallery (natural aquifer filtration)
  → Cartridge filter 5 µm
  → Antiscalant injection
  → SBS only if shock-chlorination at wellhead
  → Acid dosing
  → HPP → SWRO

Subsurface intakes naturally deliver SDI₁₅ < 3 in most geologies → skip coagulation and media filtration. Yield (m³/h per well) and risk of Fe/Mn intrusion from anoxic strata are the practical limits.

1.3 BWRO well (saline groundwater)

Well pump → aeration / oxidation (Cl2, KMnO4, or O2) if Fe/Mn > 0.05 mg/L
  → Manganese greensand / pyrolusite filter (Fe/Mn removal)
  → MMF polishing
  → Cartridge filter 5 µm
  → SBS (if Cl2 residual present)
  → Antiscalant
  → Acid (for high alkalinity / LSI)
  → BWRO

1.4 BWRO surface water

Same architecture as SWRO open intake but lower TDS, lower turbidity peaks. pH control more critical (CaCO3 dominant scaling vs Mg-sulfate).

1.5 Tertiary reuse → BWRO

Biological secondary effluent → MBR or tertiary UF/MF
  → break tank
  → cartridge filter 5 µm
  → DBNPA continuous low-dose (1 mg/L) optional
  → antiscalant (low-P or P-free)
  → BWRO 1st pass

MBR/tertiary UF typically produces SDI₁₅ 0.5–2.0; secondary effluent may exceed 3 in some months.


§2 — Pretreatment KPI Targets (pre-RO)

| Parameter | SWRO open | SWRO beach well | BWRO well | BWRO surface | Tertiary reuse |

|---|---|---|---|---|---|

| SDI₁₅ target | ≤ 3 | ≤ 2 | ≤ 3 | ≤ 3 | ≤ 3 |

| SDI₁₅ max | 5 | 3 | 4 | 5 | 5 |

| SDI₁₅ with UF | ≤ 2 | n/a | ≤ 2 | ≤ 2 | ≤ 2 |

| Turbidity (NTU) target | < 0.1 | < 0.1 | < 0.1 | < 0.1 | < 0.2 |

| Turbidity (NTU) max | 1.0 | 0.5 | 1.0 | 1.0 | 1.0 |

| Free Cl₂ pre-membrane | 0 ppm | 0 ppm | 0 ppm | 0 ppm | 0 ppm |

| ORP post-dechlor | < 200 mV | n/a | < 200 mV | < 200 mV | < 200 mV |

| AOC (µg C/L) | < 50 excellent / < 100 acceptable | < 50 | < 50 | < 100 | < 100 |

| BGP (µg/L) | < 70 | < 70 | n/a | n/a | n/a |

| Iron (mg/L) | < 0.05 | < 0.05 | < 0.05 | < 0.05 | < 0.1 |

| Manganese (mg/L) | < 0.02 | < 0.02 | < 0.02 | < 0.02 | < 0.05 |

| Aluminum residual (mg/L) | < 0.05 | < 0.05 | < 0.05 | < 0.05 | < 0.05 |

| Operating pH | 6.5–7.5 | 6.5–7.5 | 5.5–7 | 5.5–7.5 | 6–7.5 |

| Cartridge ΔP fresh | < 0.3 bar | < 0.3 bar | < 0.3 bar | < 0.3 bar | < 0.3 bar |

| Cartridge ΔP change-out | 0.7–1.0 bar | 0.7–1.0 bar | 0.7–1.0 bar | 0.7–1.0 bar | 0.7–1.0 bar |

⚠️ SDI₁₅ > 5 voids most OEM warranties. SDI₁₅ ≤ 5 is the absolute hard limit.

AOC threshold from Vrouwenvelder / Weinrich biofouling correlation studies. Raw seawater commonly 30–400 µg C/L (Tampa Bay 360 ± 180 µg/L; Monterey 30 ± 20 µg/L).

⚠️ Heavy metals (Fe³⁺, Mn²⁺, Cu²⁺, Co²⁺) catalyse SBS → oxidant conversion under O₂. Keep trace metals low and minimize SBS overdose (see §5.4).


§3 — Coagulation / Flocculation Chemistry

3.1 Coagulant comparison

| Coagulant | Formula | Dose (as product) | Dose (as metal) | Optimal pH | Notes |

|---|---|---|---|---|---|

| Ferric chloride | FeCl₃·6H₂O | 5–40 mg/L | 1–10 mg/L Fe | 5.0–8.5 (best 5–7) | Wide pH; dense floc; residual Fe³⁺ accepted < 0.05 ppm; preferred for SWRO |

| Ferrous sulfate | FeSO₄·7H₂O | 10–50 mg/L | 2–10 mg/L Fe | 8.5–11 + Cl₂ oxidize Fe²⁺→Fe³⁺ | Cheap; needs alkaline conditions |

| Alum | Al₂(SO₄)₃·14–18H₂O | 5–60 mg/L | 0.4–5 mg/L Al | 6.0–7.5 (narrow) | Al residual → AlPO₄/Al(OH)₃ fouling on RO; avoid for RO when possible |

| PAC | Al_n(OH)_m Cl_{3n-m} | 5–30 mg/L | 0.5–3 mg/L Al | 5.5–9 (wide) | Lower residual Al than alum; less pH depression; efficient at cold T |

3.2 Polymer flocculant aids

⚠️ Cationic polymer + anionic antiscalant → precipitate → RO fouling. Always jar-test the combination before deployment.

3.3 Jar test methodology

  1. Setup: 6 paddle jars × 1 L; coagulant in dilute solution (1–10 % w/v)
  2. Flash mix: 100–200 rpm × 30–60 s (G ≈ 700–1 000 s⁻¹)
  3. Flocculation: 30 rpm × 15–30 min (G ≈ 30–80 s⁻¹, tapered if possible)
  4. Settling: 30 min undisturbed
  5. Sampling: supernatant at fixed depth; measure turbidity, TOC, SDI, residual coagulant metal, pH

G value:

G = sqrt(P / (μ · V))     # P = power (W), μ = dynamic viscosity (Pa·s), V = volume (m³)

3.4 Pros/cons for downstream RO

| Aspect | Iron-based (FeCl₃) | Aluminum-based (alum, PAC) |

|---|---|---|

| Residual carryover risk | Fe³⁺ acceptable up to 0.05 ppm | Al³⁺-phosphate fouling, severe at > 0.05 ppm |

| Floc strength | Dense, settle easily | Lighter |

| pH window | Wide | Narrow (alum); wider (PAC) |

| Cold water | Good | Good (PAC) / poor (alum) |

| TOC removal | Excellent | Moderate |

| SWRO compatibility | Preferred | Avoid alum; PAC OK with caution |


§4 — Antiscalant Selection and Dose Math

4.1 Chemistry families

| Family | Examples | Best for | Typical dose | Notes |

|---|---|---|---|---|

| Phosphonate | HEDP, PBTC, ATMP, DTPMP, BHMTPMP | CaCO₃, CaSO₄, BaSO₄, SrSO₄, CaF₂ | 2–5 mg/L | Workhorse; P discharge constraints |

| Polyacrylate / acrylic homo & copolymer | PAA, AA-MA | BaSO₄, SrSO₄, suspended solids dispersion | 1–5 mg/L | P-free; lower Ca tolerance |

| Sulfonated copolymer | AA-AMPS, AA-AMPS-HPA terpolymer | High Ca, CaPO₄, ZnCO₃ | 2–5 mg/L | High Ca + alkaline tolerance |

| Maleic-based | MA-AA, polymaleic | CaCO₃, CaSO₄ broad | 2–5 mg/L | P-free; used in P-restricted discharges |

| Polymeric silica dispersant | PEG, PEGD, PVA, PAMAM, PEI | SiO₂, colloidal silica | 1–5 mg/L | For SiO₂ > 100 ppm in concentrate |

| Dendrimer / latest-gen | Polyaspartate, dendrimer-based | Broad multi-species | 1–4 mg/L | Biodegradable; premium |

4.2 Selection by scaling species

| Scaling species | Antiscalant of choice |

|---|---|

| CaCO₃ | Phosphonate (HEDP, PBTC) OR maleic-based (P-free) |

| CaSO₄ (gypsum) | Phosphonate + polyacrylate blend |

| BaSO₄, SrSO₄ | Polyacrylate or AA-AMPS (phosphonates can co-precipitate with Ba) |

| CaF₂ | Phosphonate |

| SiO₂ amorphous | Polymeric silica inhibitor (PEG/PEGD) + pH adjustment |

| Ca₃(PO₄)₂ | AA-AMPS terpolymer — NOT phosphonate |

| Fe / Mn fouling | Specialised dispersant blend |

4.3 Dose calculation

Three approaches:

  1. Vendor projection software (preferred): DuPont WAVE, Hydranautics IMSDesign, Toray DS-Design, Veolia Winflows, Avista AdvisorCi, Genesys Genesys Member. Software computes LSI / S&DSI / IP-Ksp per stage and recommends dose.
  2. LSI-driven empirical: target concentrate LSI ≤ +1.8 (conservative) or ≤ +2.5 (premium antiscalant). Typical dose 2–5 mg/L product.
  3. Jar-tested matrix: when projection unavailable.

4.4 Compatibility traps

⚠️ Cationic biocide + anionic antiscalant → precipitate.

⚠️ Phosphonate + Ba²⁺ → BaSO₄ co-precipitation under some conditions.

⚠️ Phosphate-containing antiscalant + Ca²⁺ at high pH → calcium phosphate scale (unintended).

⚠️ EU/CN P discharge limits → switch to maleic / polyacrylate / sulfonated terpolymer for compliance.


§5 — Dechlorination (SBS / SMBS)

5.1 Chemistry

Na2S2O5 + H2O → 2 NaHSO3
NaHSO3 + HOCl → NaHSO4 + HCl

5.2 Stoichiometry

⚠️ SMBS (Na₂S₂O₅) and SBS (NaHSO₃) have different molar masses — confirm which the dosing pump is metering and adjust stoichiometry accordingly.

5.3 Chloramines

5.4 The oxidant paradox

Under DO + transition metal traces (Cu²⁺, Co²⁺, Fe³⁺, Mn²⁺):

2 NaHSO3 + O2  --[Cu/Co]-->  2 NaHSO4 + sulfite radicals (SO3•⁻, SO4•⁻)

Sulfite radicals attack polyamide. Residual SBS up to 30 ppm has been reported to convert partially to oxidants in this scenario.

⚠️ Chronic SBS overdose is not safer than just-right dosing. Keep margin small (just enough to neutralize Cl₂); minimise air ingress in suction lines; deaerate where Cu/Co > trace.

5.5 Monitoring

5.6 SBS solution preparation

⚠️ Do not store dechlorinated water in tanks — promotes bacterial regrowth between dechlor and HPP.

5.7 Alternative: GAC

| Aspect | SBS | GAC |

|---|---|---|

| CapEx | Low | High |

| OpEx | Recurring chemical | Periodic media replacement (1–3 yr) |

| Reliability | Active control loop | Passive failsafe |

| Bacterial regrowth | None | High (bed = bioreactor) |

| ORP control needed | Yes | No |

| SWRO use | Primary | Rare (footprint, bio) |

| Pharma / USP use | Sometimes | Common (chlorine-free + TOC reduction) |


§6 — CO₂ / pH Management

6.1 Why CO₂ matters

6.2 Strategies

| Strategy | CO₂ outlet | Use when | Notes |

|---|---|---|---|

| Interpass NaOH injection | residual converted to HCO₃⁻, rejected by pass 2 | 2-pass RO present | Target interpass pH 8.4–8.7; also boosts boron and silica rejection |

| Membrane degasser (PTFE/PP hollow fiber, e.g. Liqui-Cel) | < 5 ppm typ, < 0.5 ppm achievable | RO + EDI (no 2nd RO) | Vacuum and/or sweep gas; CIP every 3–6 months |

| Forced-draft atmospheric tower | 5–10 ppm | Lower-purity applications | Open to atmosphere → bacterial ingress risk |

| Vacuum tower degasser | 1–5 ppm | High-purity preferred | Higher CapEx than membrane |

6.3 pH control loop

⚠️ Buffer-poor RO permeate → small dose causes large pH swing. Tune integral term carefully or use cascade control.

6.4 pH effects on rejection (2nd pass)

Tradeoff: pH > 8 increases CaCO₃ scaling risk on 2nd-pass concentrate if Ca slip from 1st pass.


§7 — Biocide Strategy (Split Pre/On Membrane)

7.1 Pre-RO (oxidising OK, must be removed before membrane)

| Agent | Typical dose | Notes |

|---|---|---|

| NaOCl / Cl₂ | 0.5–2 mg/L continuous; 5–10 mg/L shock | Must dechlorinate before RO |

| Chloramine (NH₂Cl) | 1–4 mg/L | Slower kill but persistent; less DBPs |

| ClO₂ | 0.1–0.5 mg/L | Stronger; damages PA more aggressively than Cl₂ — never let through |

| O₃ | 0.5–2 mg/L | Strong; full decomposition required before membrane |

| KMnO₄ | 0.5–5 mg/L | Fe/Mn oxidation; Mn must be filtered out |

7.2 On-membrane (non-oxidising only)

| Biocide | Active conc. | Mode | Contact | PA compatibility |

|---|---|---|---|---|

| DBNPA (2,2-dibromo-3-nitrilopropionamide) | 10–50 mg/L shock; 1 mg/L continuous | Shock or continuous | 30 min – 3 h | Excellent; hydrolyses rapidly (half-life hrs–days) |

| CMIT/MIT (isothiazolinone blend) | 25–100 mg/L | Shock during CIP | 1–24 h | Good; optimum pH 6.5–8.5; hydrolyses above pH 9 |

| BIT (1,2-benzisothiazolin-3-one) | 50–100 mg/L | Shock | 1–4 h | Good; longer environmental persistence |

| Glutaraldehyde | 100–500 mg/L shock; 1 % storage | Shock + preservation | 1–4 h | Compatible; toxicity / handling concerns |

| Formaldehyde | 0.5–1 % (storage only) | Storage | n/a | Legacy; carcinogen — discouraged; banned in some EU member states |

| Quaternary ammonium | Limited | Compat varies | n/a | Cationic — risk of precipitation with anionic antiscalant; not recommended on PA |

| Peracetic acid (PAA) | 50–200 mg/L | CIP | < 1 h | Some vendors allow; strong oxidant — check OEM approval |

7.3 Shock dosing protocols

7.4 Storage / preservation


§8 — Monitoring Instrumentation

8.1 SDI test (ASTM D4189-23)

1. Measure time t_i to collect 500 mL at t = 0

2. Flow at 30 psi for 15 min (or 5/10 min if filter plugs early)

3. Measure t_f to collect 500 mL at t = 15 min

SDI15 = 100 · (1 − t_i / t_f) / 15

Units: % per minute drop in flux.

8.2 Online instrumentation (typical set)

| Parameter | Sensor | Location | Action threshold |

|---|---|---|---|

| Turbidity | Nephelometric (Hach 2100, Endress+Hauser CUS52D, Yokogawa) | Post media filter, post UF | Alarm > 0.2 NTU |

| Free Cl₂ | DPD analyzer (Wallace & Tiernan, E+H CCS51D) | Post dechlor | Trip > 0.05 ppm |

| ORP | Ag/AgCl electrode | Pre and post dechlor | Trip > 200 mV post-SBS |

| Conductivity | Inductive (high TDS) or contacting (RO permeate) | Feed, permeate, concentrate per stage | Mass balance, salt passage |

| pH | Glass or solid-state | Post acid/caustic injection | PID control |

| Pressure | Piezo-resistive | Each stage feed/perm/conc | ΔP trending |

| Flow | Electromagnetic (preferred), Coriolis (high accuracy) | Feed, perm, conc, recycle | Recovery, mass balance |

| Iron (optional) | Colorimetric (Hach) | Feed | Monthly grab |

| TOC (high-purity) | UV oxidation analyzer | RO permeate, EDI product | UPW spec |

| SDI | Automatic (Sterlitech SimpleSDI:Auto) or manual | Pre-cartridge | Daily check |

💡 Mass-balance closure check (|Qf − (Qp + Qc)| / Qf < 2 %) on the feed/permeate/concentrate flow set is essential — without it, instrument drift produces phantom KPI alerts.


§9 — Bilingual IT/EN Glossary

| EN | IT |

|---|---|

| Pretreatment | Pretrattamento |

| Intake | Opera di presa |

| Brine outfall | Scarico salamoia |

| Beach well | Pozzo costiero |

| Open intake | Presa diretta a mare |

| Screening (coarse/fine) | Grigliatura (grossolana/fine) |

| Coagulation | Coagulazione |

| Flocculation | Flocculazione |

| Sedimentation | Sedimentazione |

| Dissolved Air Flotation (DAF) | Flottazione ad aria disciolta |

| Multimedia filter (MMF) | Filtro multistrato |

| Dual-media filter (DMF) | Filtro bistrato |

| Cartridge filter | Filtro a cartuccia |

| Ultrafiltration (UF) | Ultrafiltrazione |

| Antiscalant | Antincrostante |

| Biocide | Biocida |

| Shock dosing | Dosaggio shock |

| Dechlorination | Declorazione |

| Jar test | Jar test (anglicismo) |

| Break-tank | Vasca di rottura |

| Backwash | Controlavaggio |

| Cleaning In Place (CIP) | Lavaggio in posto |

| High Pressure Pump (HPP) | Pompa di alta pressione |

| Recovery | Recupero / resa |

| Reject / concentrate / brine | Concentrato / salamoia |

| Permeate | Permeato |

| Free chlorine | Cloro libero / residuo |

| Combined chlorine / chloramine | Cloro combinato / cloramine |

| Oxidation-Reduction Potential | Potenziale redox (ORP) |

| Silt Density Index | Indice di Densità del Limo (SDI) |

| Assimilable Organic Carbon | Carbonio Organico Assimilabile (AOC) |

| Biological Growth Potential | Potenziale di crescita biologica (BGP) |

| Total Organic Carbon | Carbonio organico totale (TOC) |

| Biodegradable DOC | DOC biodegradabile (BDOC) |

| Polyamide | Poliammide (PA / TFC) |


Sources

Use this skill with your AI agent: Open on Skill Issue to copy, download, or add to your library. Works with Claude, ChatGPT, Gemini, Cursor, Windsurf and more.