Membrane autopsy

From claude-dev-suite/claude-dev-suite · View interactive version

Membrane autopsy is an AI agent skill from the GitHub repository claude-dev-suite/claude-dev-suite. Membrane autopsy lab methodology — autopsy decision matrix (when to autopsy), element sampling protocol (which to pick, preservation, data package), lab method suite (visual / weight-loss / dye test per ASTM D6908 / SEM-EDS / FTIR / swab + plate count / Fujiwara chlorine test / cross-section), findi

How to use this skill

Skill file

Membrane Autopsy

Reference for deciding when to autopsy a membrane element, how to ship it, what each lab method reveals, and how to translate findings into operational action or a warranty claim.

Convention markers:


§1 — When to Autopsy (Decision Matrix)

1.1 Trigger conditions (any one suffices)

| Trigger | Threshold | Notes |

|---|---|---|

| Salt rejection drop (passage rise) | > 10 % vs baseline, persistent after 2 CIPs | Avista / AWC / Vipanan canonical trigger |

| Normalized ΔP (ΔPn) rise | > 15–25 % not recovered by CIP | DuPont 45-D01652: 15 % action; many operators use 20–25 % post-CIP |

| Normalized permeate flow (NPF) decline | > 10–25 % not recovered by CIP | Biofouling signature: ΔP impacted first, then flux, then rejection |

| Unexplained instrument disagreement | Persistent after sensor calibration | Rules out membrane vs instrumentation root cause |

| End-of-warranty diagnostic | Before warranty expiry | Required to file manufacturing-defect claim |

| Premature failure pattern | Multiple elements < expected life | Especially when concentrated in lead or tail positions |

| Suspect chlorine breakthrough | Cumulative ppm·h record exists OR ORP excursion | Fujiwara test confirms halogenation |

| Pre-replacement diagnostic | Before bulk replacement decision | Validates cleaning options before procurement |

1.2 Cost-benefit framing

Public vendor websites do not publish autopsy price lists — all require a quote. Indicative ranges from industry practice (planning indicators, not contractual):

| Scope | Indicative range (USD) | Use case |

|---|---|---|

| Basic: visual + dye + weight-loss | ~$500–1 000 | Quick screen, single element |

| Standard (Genesys "Tier 2-3"): + SEM/EDS + FTIR + cleaning study | ~$1 500–2 500 | Most common; supports warranty claim |

| Advanced (Tier 4-5): + 16S rRNA + cross-section + Fujiwara + ATP + LOI | ~$2 500–5 000 | Complex/persistent failures, expert-witness |

| Vendor warranty autopsy (DuPont, Hydranautics, Toray) | Free, if claim accepted | RMA process; vendor-affiliated lab |

Pays off when: multiple elements need replacement, warranty claim plausible, recurring failure pattern needs root-causing.


§2 — Sampling Protocol

2.1 Which element to autopsy

| Position | What it reveals | When to pick |

|---|---|---|

| Lead element of lead vessel | Particulate / colloidal fouling, biofouling, oxidation damage, organics, oil/grease | Default; fouling-dominant problems; suspected chlorine breakthrough |

| Tail element of last vessel | Scaling (CaCO₃, CaSO₄, BaSO₄, SiO₂), compaction | Rejection drop suspected scale-driven; LSI/recovery review |

| Lead + tail | Complete fouling picture | Generous budget, systemic problem |

| Failed element (via probing) | Localized integrity loss | Probing identifies a specific outlier |

For budget-limited cases pick lead unless symptoms point to tail.

2.2 Element preparation post-removal

  1. Do not air-dry — desiccation alters biofilm morphology and chemistry, masks NOM, kills microbial signal
  2. Wrap in heavy plastic (double-bag); label with element serial, position, removal date
  3. Refrigerate at 4 °C within 24 h; ship in insulated container with cold packs
  4. Do not freeze — ice crystals damage PA and disrupt cross-section integrity
  5. Ship within 48–72 h
  6. Photograph all external surfaces under good light before shipment (telescoping, glue line, end-cap, brine seal, fiberglass shell). Photos are essential for warranty claims

⚠️ Do not preserve the entire element in SMBS if microbial culture from the main sample is required — SMBS suppresses what you want to grow. Keep a separate witness coupon in 0.5–1 % SMBS if biofilm is the suspect and shipping is slow.

2.3 Pre-autopsy data package (ship with the element)

The lab — and, if applicable, the vendor warranty desk — both require:

⚠️ Without this data package the lab can identify the what but not the why, and warranty submissions are routinely rejected for missing pretreatment logs.


§3 — Lab Method Suite

For each: what it reveals, indicative cost, limitations.

3.1 Visual inspection

3.2 Weight-loss / Loss-on-Ignition (LOI)

3.3 Cleaning effectiveness test

3.4 Salt-rejection retest

3.5 Dye test (Rhodamine WT or Red Dye #40 per ASTM D6908)

| Stain pattern | Defect |

|---|---|

| Diffuse, full-membrane | Chemical attack (oxidation, hydrolysis) — confirm with Fujiwara |

| Localized point | Pinhole — hydraulic shock, particulate puncture |

| Linear / straight line | Glue-line crack — manufacturing or handling |

| Edge concentration | O-ring or brine-seal bypass |

3.6 SEM / EDS

Cheat sheet:

| EDS dominant elements | Foulant |

|---|---|

| Ca + C (+ Mg) | CaCO₃ scaling |

| Ca + S | CaSO₄ |

| Ba + S | BaSO₄ (very low solubility — usually irreversible) |

| Sr + S | SrSO₄ |

| Si dominant | Silica (amorphous or quartz) |

| Fe (± Mn) | Iron/manganese oxide |

| Al + Si | Aluminosilicate (clay) |

| C + N + P high, low metals | Biofilm / organic |

| P + Ca | Calcium phosphate |

3.7 FTIR / ATR-FTIR

| Band (cm⁻¹) | Assignment |

|---|---|

| 1650 (amide I, C=O) | Protein OR polyamide active layer |

| 1540–1550 (amide II, N–H) | Protein / polyamide |

| 1010–1040 | Polysaccharides (biofilm EPS) |

| 1720 (C=O carboxylic) | Humic / NOM |

| 1080 (Si–O–Si) | Silica |

| 1450, 870 (CO₃²⁻) | Carbonate |

| 2800–3000 (C–H) | Aliphatic — oil/grease, surfactant, antiscalant residue |

Loss/shift of amide I/II from the polyamide itself indicates oxidative degradation.

3.8 Biofilm characterization

3.9 Fujiwara test (chlorine attack confirmation)

3.10 Cross-section analysis

3.11 Optional: PDT / VDT (per ASTM D6908)

Pressure or vacuum decay test — pressure applied to permeate side, decay rate quantifies leak. More common at module/system level than on a dissected element, but useful when the lab runs an integrity workflow.


§4 — Findings → Root Cause → Action

| Lab finding | Root cause | Operational action |

|---|---|---|

| EDS Ca + C dominant, rhombohedral SEM crystals | CaCO₃ scaling | Review LSI/S&DSI at concentrate; antiscalant dose/selection; acid CIP (citric or HCl, pH 2–3) |

| EDS Ca + S | CaSO₄ scaling | Lower recovery OR upgrade antiscalant (HEDP, polyacrylate); chelant CIP (EDTA pH 11–12) |

| EDS Ba + S (or Sr + S) | BaSO₄ / SrSO₄ scaling — generally irreversible | Antiscalant upgrade to DTPMP; if extensive, replace |

| EDS Si dominant | Silica scaling | Review pH, T, recovery; warm-water alkaline CIP (pH 11–12, ≥ 35 °C if vendor allows); if cemented, replace |

| EDS Fe (± Mn), reddish SEM | Iron / manganese oxidation upstream | Audit prefiltration / oxidation / pH; reductive CIP with sodium hydrosulfite (Na₂S₂O₄) at 1 %, pH 5; or citric + ammoniated citric |

| EDS high C, N, P; SEM biofilm; ATP high | Biofouling | Non-oxidizing biocide CIP (DBNPA, isothiazolinone); reduce AOC upstream; consider continuous low-dose |

| FTIR humic peaks (~1720, 1620 cm⁻¹) | Organic NOM fouling | Upstream coagulation review; alkaline CIP (NaOH + EDTA pH 12) |

| FTIR C-H aliphatic, EDS C only | Oil / grease / surfactant | Pretreatment audit; intake protection; surfactant CIP |

| Dye diffuse + Fujiwara positive | Chlorine / chloramine oxidation | Dechlor failure — audit SBS dosing / ORP loop; replace element |

| Dye localized point | Mechanical pinhole | Investigate pressure shocks, particulate breakthrough; replace |

| Dye linear line | Glue-line crack | Manufacturing defect → warranty claim; replace |

| Dye edge concentration | O-ring / brine-seal failure | Replace seal, verify orientation, re-test |

| Salt-rejection retest > 5 % below spec, FTIR amide change | Chemical attack or hydrolysis | Replace |

| Permeate-spacer imprint on PA, low NPF | Compaction | Reduce feed pressure; replace if severe |

| Cleaning recovery ≥ 90 % | CIP-treatable | Deploy proven recipe in field; schedule CIP frequency |

| Cleaning recovery < 70 % | Replace | No CIP benefit |


§5 — Vendor Labs and Cost Ranges

Independent / third-party labs (paid)

Vendor-affiliated (free with valid warranty claim)

Academic / research


§6 — Warranty Claim Workflow

6.1 Typical warranty terms (verify on the actual element warranty document)

Manufacturer terms vary and are shorter than industry folklore suggests:

⚠️ The "3 yr SWRO / 5 yr BWRO" working assumption commonly seen in process literature is not universally accurate. Hydranautics' standard text is 12 months. Treat per-vendor PO terms as authoritative.

6.2 Common exclusions (consistent across vendors)

6.3 Documentation the vendor will request

6.4 Process

  1. Open the claim BEFORE pulling the element. Some vendors require witness or specify the disassembly procedure. Pulling first can void the claim.
  2. Vendor issues RMA / return authorization
  3. Ship per vendor instructions (refer to §2.2). Vendor autopsy is performed at no cost if the claim is accepted
  4. Outcomes:
  1. Independent autopsy first is a defensible strategy when:

💡 A warranty_workflow.md operational SOP that codifies "open RMA before pulling element" + "ship with data package per §2.3" should live in the plant operator handbook, not just in the asset management system.


§7 — Bilingual IT/EN Glossary

| EN | IT |

|---|---|

| Membrane autopsy | Autopsia (della) membrana |

| Foulant identification | Identificazione del foulant / dello sporcante |

| Dye test | Test di colorazione |

| Weight-loss test | Test di perdita di peso |

| Loss-on-ignition (LOI) | Perdita per calcinazione |

| Cross-section | Sezione trasversale |

| SEM (Scanning Electron Microscopy) | Microscopia elettronica a scansione |

| EDS (Energy-Dispersive Spectroscopy) | Spettroscopia a dispersione di energia |

| FTIR | Spettroscopia FTIR |

| ATR-FTIR | FTIR in riflettanza totale attenuata |

| Swab plate count | Conta in piastra da tampone (swab) |

| Fujiwara test | Test di Fujiwara |

| Warranty claim | Reclamo in garanzia |

| Premature failure | Guasto prematuro |

| Manufacturing defect | Difetto di fabbricazione |

| Telescoping | Telescopaggio (deformazione assiale) |

| Glue line | Linea di colla / incollaggio |

| Brine seal | Guarnizione di concentrato |

| O-ring | Guarnizione O-ring |

| Lead element | Elemento di testa |

| Tail element | Elemento di coda |

| Normalized permeate flow | Portata permeato normalizzata |

| Normalized salt passage | Passaggio sale normalizzato |

| Compaction | Compattazione |

| Biofouling | Biofouling / sporcamento biologico |

| Scaling | Incrostazione |

| CIP (clean-in-place) | Lavaggio in posto |

| Reductive cleaning | Lavaggio riducente |

| Free chlorine | Cloro libero |

| ORP | Potenziale di ossido-riduzione |

| SDI (Silt Density Index) | Indice di intasamento (SDI) |

| Independent autopsy | Autopsia indipendente / di terza parte |

| Vendor-affiliated autopsy | Autopsia presso lab del costruttore |

| RMA (Return Material Authorization) | Autorizzazione al reso |

| Witness section / coupon | Campione di riscontro |


Sources

Use this skill with your AI agent: Open on Skill Issue to copy, download, or add to your library. Works with Claude, ChatGPT, Gemini, Cursor, Windsurf and more.