Evaluating with Leakage Gates
OpenMed's release gates answer one question: did any PHI leak? A de-id model
with a beautiful F1 can still leak a single SSN — and that one leak is a HIPAA
breach. So openmed.eval gates on residual leakage and *per-label recall
floors*, not on aggregate F1. The candidate is either RELEASABLE or
QUARANTINED; there is no partial credit.
When to use this skill
- You have a candidate de-id or PII model and need a ship / no-ship decision.
- You want to run the benchmark harness over a synthetic golden suite.
- You need to enforce direct-identifier recall floors and
critical_leakage == 0. - You need calibration thresholds (
thresholds.json) before the gate will pass. - You want a signed, reproducible gate report for governance.
This is the flagship eval skill. For a pure NER scorecard see
benchmarking-clinical-ner; for CI wiring see gating-deid-leakage.
The gates (G1a–G8)
| Gate | Checks | Floor / rule |
| --- | --- | --- |
| G1a | Direct & quasi identifiers (PERSON, EMAIL, PHONE, SSN, ID_NUM, DATE_OF_BIRTH, ...) | recall ≥ 0.990 (v1.6) / 0.995 (v2.0); strict-no-leak policies raise the floor |
| G1b | Structured secrets (API_KEY, ACCOUNT_NUMBER, CREDIT_CARD, IBAN) | recall ≥ 0.995 |
| G2 | Free-text names/locations/dates | recall ≥ 0.980 (v1.6) / 0.990 (v2.0) |
| G3 | Critical leakage (SSN, CREDIT_CARD, CVV, API_KEY, PIN, IBAN, ...) | count must be exactly 0 |
| G4 | Quantized recall delta vs fp parent | within INT8 / INT4 limits |
| G5 | Latency & RAM vs device tier budget | p50/p95/RAM under tier budget |
| G6 | p50/p95 latency documented | must be present and finite |
| G7 | Baseline regression | recall drop ≤ 0.002/label; leakage ≤ soft ceiling 0.005 and ≤ steward target; no leakage regression vs last-green |
| G8 | Span integrity | predicted spans validate (no overlaps/out-of-range) |
Constants live in openmed.eval.release_gates (G1A_V16_RECALL_FLOOR,
G1B_RECALL_FLOOR, G7_RECALL_DROP_LIMIT, RESIDUAL_LEAKAGE_SOFT_CEILING, ...).
Confirm them there rather than hardcoding — they move per milestone.
Quick start
Run a candidate benchmark over a synthetic golden suite, then gate it:
from openmed.eval import run_suite, ReleaseGate, RELEASABLE
# 1) Produce a candidate BenchmarkReport from a SYNTHETIC fixtures file.
# Each fixture carries gold PHI spans; no real patient text is committed.
report = run_suite(
"eval/golden/phi_synthetic.json", # user-supplied synthetic fixtures
suite="golden",
model_name="OpenMed/Privacy-PII-Detection",
device="cpu",
metadata={
"family": "PII",
"tier": "base",
"policy": "hipaa_safe_harbor",
# calibration artifacts are required for mask/replace policies (see below)
"thresholds_path": "eval/artifacts/thresholds.json",
"calibration_report_path": "eval/artifacts/calibration_report.json",
},
)
# 2) Gate it. The gate reads the last-green baseline store read-only and
# returns a signed GateReport.
gate = ReleaseGate(milestone="v1.6", policy="hipaa_safe_harbor")
decision = gate.evaluate(report)
print(decision.decision) # "RELEASABLE" or "QUARANTINED"
for check in decision.gate_results:
if not check.passed:
print(check.gate, "->", check.reason, check.details)
assert decision.decision == RELEASABLE, "do not ship a quarantined model"
CLI equivalent (fails closed, exit code 1 on quarantine):
python -m openmed.eval.release_gates \
--candidate eval/out/candidate_report.json \
--milestone v1.6 --policy hipaa_safe_harbor \
--output release-gate-report.json
Workflow
- Build a synthetic golden suite. Fixtures are JSON with
textand
gold_spans (offsets + labels). Use building-gold-corpus to scaffold one.
Committed gold must be synthetic; DUA corpora (i2b2/n2c2) are eval-only and
never committed.
- Fit calibration thresholds for any policy that masks or replaces:
```python
from openmed.eval import write_calibration_artifacts
paths = write_calibration_artifacts(
calibration_samples, # held-out score/target samples
artifact_dir="eval/artifacts",
model_id="OpenMed/Privacy-PII-Detection",
suite="golden",
target_leakage=0.0, # leakage-first: drive leakage to 0
)
# writes thresholds.json + calibration_report.json the gate looks for
```
The gate's calibration_present check fails the build if these are missing
for a mask/replace policy.
- Run the suite (
run_suite/run_benchmark) to get aBenchmarkReport. - Evaluate with
ReleaseGate(...).evaluate(report). - Read the per-gate results. Each
GateCheckcarriesgate,passed,
reason, and details (e.g. which labels fell below the recall floor).
- Fail closed. Treat anything other than
RELEASABLEas a hard stop. - Audit subgroups with
fairness_report(seeauditing-subgroup-fairness)
so an aggregate pass doesn't hide an under-protected group.
Hand-off to / from OpenMed
- From
building-with-openmedand the de-id pipeline: you evaluate the model
produced by openmed.deidentify / openmed.extract_pii.
- To
gating-deid-leakage: wrapReleaseGate.evaluate(...)in a pytest/CLI
gate so CI fails closed on regression.
- To
authoring-model-cards: feedGateReport,fairness_report, and
error_report outputs into the model card's metrics and limitations sections.
- Pairs with
auditing-subgroup-fairness(fairness_report) and
benchmarking-clinical-ner (error_report).
Edge cases & gotchas
- F1 is not a gate. A model can have higher F1 and still be quarantined if it
leaks one critical identifier (G3) or drops a label below its floor (G1a/G1b).
- Calibration is mandatory for mask/replace policies. No
thresholds.json→
calibration_present fails → QUARANTINED.
- Baselines are read, never written, by the gate. The gate compares against
the last-green baseline store without mutating it (G7). Promote baselines in a
separate, deliberate step.
- Strict-no-leak policies raise the G1a floor and force the leakage target to
0. Don't assume the default floor.
- Reports must carry identity metadata (
family,tier,format,
eval_set_hash, leakage_fixture_hash); manifest_coherence fails without it.
- Reports are signed (HMAC-SHA256). Set
OPENMED_RELEASE_GATE_KEYfor a real
signing key; GateReport.verify(key) checks the repro hash and signature.
- No raw PHI in the report. Gate evidence is offsets, hashes, and labels —
never plaintext identifiers. Keep it that way in any wrapper you write.
Standards & references
- HIPAA Safe Harbor / Expert Determination (45 CFR 164.514):
https://www.hhs.gov/hipaa/for-professionals/privacy/special-topics/de-identification/
- NIST SP 800-188, De-Identification of Personal Information:
https://csrc.nist.gov/pubs/sp/800/188/final
- i2b2 2014 de-identification shared task (recall-first evaluation tradition):
https://doi.org/10.1016/j.jbi.2015.06.007
- OpenMed eval source of truth:
openmed/eval/release_gates.py,
openmed/eval/harness.py, openmed/eval/calibrate.py.