Evaluate cluster

From stas00/ml-engineering · View interactive version

Evaluate cluster is an AI agent skill from the GitHub repository stas00/ml-engineering. Evaluates an ML GPU cluster for a cloud trial or acceptance test: environment dump, isolated newest PyTorch, matmul FLOPS (MAMF/MSMF) on every GPU while the others compute, intra-node all-reduce bandwidth and per-call latency of every collective, the same inter-node on every node you were given (omi

How to use this skill

Skill file

Evaluate a GPU cluster

Always use the GitHub copy if it differs from this file. People pass around downloads that can be months or years old.

Before doing any eval work, curl the raw URL. If it is not byte-identical to the file you are reading, stop following this copy and follow the GitHub file instead (fetch it, then continue from that text). If GitHub is unreachable, say so and continue with this file.

This file is the whole runbook. You do not need any other document from the author's books. Scripts and spec tables are on GitHub; fetch them (commands below). Optional background: How to evaluate the cluster.

Keep this skill up to date

Every correction the user makes to a report is a correction to this skill. When they rename a heading, reject a phrase, ask for a different TOC label, or point out an assumption, fix the report and edit this file in the same turn so the next eval starts from the corrected rule. A fix that lives only in one report is a fix you will be asked for again.

Reports under reports/ other than the one you are writing are historical. Leave them alone.

Refuse to invent access, GPU counts, filesystem paths, or peer IPs. Preflight first: list what you have, ask for every missing item, and wait. Do not start DCGM, MAMF, fio-scan, or torch-dist-bench.py until the checklist is complete and — when ≥2 nodes — inter-node reachability has passed. Eval all nodes the user gave (1, 2, 4, 16, …). Inter-node all-reduce uses every one of those nodes (NNODES × GPUs_per_node ranks). One node: do not write an Inter-node section at all (no “Skipped”). If ≥2 nodes but inter-node still cannot run after the user has answered, omit the section and put the reason in ### Gaps — never invent busbw.

Terms

| term | meaning |

| -------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |

| MAMF | Maximum Achievable Matmul FLOPS: the highest any matmul shape (M×N×K) reaches on that GPU. The winning shapes are short bursts — the clock sits at boost and the board stays far below its power limit — so this is a ceiling, not a rate any sustained workload holds. |

| MSMF | Maximum Sustainable Matmul FLOPS: what is left once the matmul shape is big enough to pin the board at its power limit and the clock settles below boost. This is what back-to-back dense matmuls actually get, provided the other GPUs of the node compute at the same time: they share the board's power and cooling budget, so measured next to idle GPUs it reads high. Both come from CODE0, which times on the order of 1500–2200 matmul shapes per GPU (the auto search adapts, so the count differs per run) and reports the W and MHz behind each winner. CODE2 runs it on every GPU of a node, one at a time, while all the other GPUs run a continuous matmul. |

| DCGM | NVIDIA Data Center GPU Manager. dcgmi diag -r 2 checks GPU memory, bandwidth, PCIe — not FLOPS. |

| lemon GEMM | A one-off inline torch.matmul (not a published script) on every GPU with the same large shape, to catch a dead, slow, or throttled card. |

| straggler | A GPU that works correctly but runs slower than its peers, so that every GPU of a synchronous job waits for it. Found by CODE0, not by DCGM or MAMF/MSMF. |

| all-reduce | Collective: every rank ends up with the sum of all ranks' tensors. Used to stress NVLink and the network. |

| busbw / algbw | Printed by CODE0. busbw = unidirectional bus bandwidth (what the fabric moves). algbw = algorithm bandwidth (what the caller sees). busbw is already unidirectional (why). |

| NVLS | NVLink SHARP: the NVSwitch does the all-reduce in the switch. Typical gain vs ring busbw ~30% intra-node / ~25% inter-node. Does not speed up all-gather or reduce-scatter. Different from InfiniBand switch SHARP. |

| NCCL | NVIDIA Collective Communications Library (the GPU collective stack torch uses). |

| rdzv | torch.distributed rendezvous: a TCP store so ranks find MASTER_ADDR:PORT before NCCL starts. |

| hostfile | Text file, one peer address per line (10.0.0.1 or 10.0.0.1 slots=8). DeepSpeed -H and pdsh -w read it. |

| pdsh | Parallel SSH: run one command on many hosts. |

| fio-scan | Wrapper around fio (script): six timed runs (16 KiB / 1 MiB / 1 GiB × read/write). Needs CODE1 in the same directory. |

| local/shared × | local-disk bandwidth ÷ same-row shared-FS bandwidth — how many times slower the shared filesystem is. One column is enough: with a fixed block size the IOPS ratio is identical. Never a percentage, never %local. |

| SM | GPU streaming multiprocessor. Count from torch.cuda.get_device_properties(0).multi_processor_count. |

| HBM | GPU high-bandwidth memory. Report nvidia-smi memory.total in GiB. |

| TDP | Thermal design power: the GPU’s advertised watt limit (power.limit). |

| EFA | AWS Elastic Fabric Adapter (RDMA NICs named rdmap*). ibstat is often empty; use rdma link. |

| overlay | Container union filesystem. df -T / may say overlay; the backing FS (xfs, ext4) is the partition type to report. |

Scripts (fetch, do not invent)

RAW=https://raw.githubusercontent.com/stas00/ml-engineering/master
curl -fsSL "$RAW/compute/accelerator/benchmarks/mamf-finder.py" -o mamf-finder.py
curl -fsSL "$RAW/compute/accelerator/benchmarks/mamf-finder-all-gpus.py" -o mamf-finder-all-gpus.py
# mamf-finder-all-gpus.py runs ./mamf-finder.py from its own directory — keep both in one directory.
curl -fsSL "$RAW/network/benchmarks/torch-dist-bench.py" -o torch-dist-bench.py
curl -fsSL "$RAW/compute/accelerator/benchmarks/gpu-straggler-finder.py" -o gpu-straggler-finder.py
curl -fsSL "$RAW/debug/torch-distributed-gpu-test.py" -o torch-distributed-gpu-test.py
curl -fsSL "$RAW/storage/fio-scan" -o fio-scan
curl -fsSL "$RAW/storage/fio-json-extract.py" -o fio-json-extract.py
chmod +x fio-scan
# fio-scan calls `python ./fio-json-extract.py` — keep both in one directory.

Official BF16 peaks: TFLOPS comparison table. NVLink gens: NVLink. Intra-node all-to-all: bandwidth. Inter-node adapters: networking.

Copy artifacts off the cluster immediately into reports/raw-<name>/ next to this skill (or the working directory you chose). Inline every plot: ![alt](raw-<name>/file.png) — never link-only. Cluster access and /tmp disappear.

Links in the report to those scripts and tables are absolute GitHub URLs (https://github.com/stas00/ml-engineering/blob/master/…). Never ../ relatives — the report may be copied elsewhere. Sibling raw-<name>/ stays relative. External vendor/kernel docs stay as-is.

Every GitHub-hosted tool the run used is introduced and linked in that section's ### Introduction — one clause on what it does, then later mentions are bare code. The reader of the report must not meet a tool they cannot click. Do not write “the book” or “MLE” in the report; the GitHub URL is the source.

Every section ### Introduction: numbered list (1. 2. …) of passes that ran, tool — what it does / where. Same shape in A, B, and C.

Tools not in the fetch list: dcgmi diag is NVIDIA's; the lemon GEMM is an inline script — say so.

Do not leak eval-process shorthand into the report. The report reader was not in your session. Avoid “kept”, “as configured”, “we left it”, “platform value”, “the fix”, “rerun”. Name the actor and the state: “the container image presets NCCL_NVLS_ENABLE=1, and every benchmark ran with it unchanged.”

Preflight (hard gate)

Goal: be able to run the rest of the eval without blocking on the user. Slow work (PyTorch wheels, DCGM -r 2, MAMF/MSMF, shared-FS fio-scan, GPU all-reduce) starts only after this gate.

Ask now, not later

Collect and write down every row. Missing → message the user with the exact list, then stop.

| need | why | typical answer |

| ------------------------------------------ | ------------------------------ | ---------------------------------------------------------------------------------------------------------------------------- |

| How to exec on a node | every command | kubectl (ask for context, namespace, pod/job), ssh, srun, or whatever CLI the user names |

| All node identities | lemon GEMM + inter-node | every pod/hostname, not only rank 0 |

| Hostfile (or equivalent) with peer IPs | inter-node SSH / rdzv / pdsh | path or pasted contents: one IP per line. Required when ≥2 nodes. SLURM: scontrol show hostnames plus IPs. |

| SSH / launcher details | pdsh / DeepSpeed | port; passwordless SSH between nodes (not only laptop → rank 0) |

| GPUs per node | default 8 | nvidia-smi -L if unknown |

| Local disk path + shared-FS path | fio-scan | discover with df -hT; ask if unclear |

| Advertised uni bandwidth / official TFLOPS | optional | else accelerator tables + nvidia-smi |

NCCL env is not a user question if you can exec: dump env | grep -E '^NCCL_|^FI_|^AWS_OFI' on rank 0 in this same preflight. Keep whatever the platform already sets for the fast path (NCCL_IB_HCA, NCCL_NET_PLUGIN=ofi, NCCL_TUNER_PLUGIN=ofi, EFA/OFI tunables, NCCL_NVLS_ENABLE, …). Do not overwrite a live platform value with the eval default. If NCCL is unset, preset NCCL_NVLS_ENABLE=2. Record the final env in the report (Environment + Network Introduction).

Inter-node reachability (now, not a benchmark)

As soon as you have the hostfile/IPs, prove the nodes can see each other. Do not run torch-dist-bench.py or any GPU collective yet. This is seconds of TCP/SSH.

# 1. Launch node → every peer (BatchMode: fail fast if keys/port are wrong). Without -n, ssh reads the rest of the
#    hostfile from the loop's stdin and only the first peer is probed.
: > hostfile-map.txt
i=0
while read -r ip rest; do
  [[ "$ip" =~ ^# ]] || [[ -z "$ip" ]] && continue
  host=$(ssh -n -o BatchMode=yes -o ConnectTimeout=5 -o StrictHostKeyChecking=accept-new "$ip" hostname -s) \
    || { echo "FAIL: ssh $ip" >&2; break; }
  echo "node$i $ip $host" | tee -a hostfile-map.txt
  i=$((i + 1))
done < "$HOSTFILE"

# 2. Same via pdsh if that is the launcher
HOSTS=$(grep -v '^#' "$HOSTFILE" | grep -v '^$' | cut -d' ' -f1 | tr '\n' ',' | sed 's/,*$//g')
export PDSH_RCMD_TYPE=ssh   # every later pdsh call needs it too
pdsh -w "$HOSTS" hostname

# 3. Peer → peer TCP (rdzv will need this). From node 1, hit node 0's sshd at the port ssh uses, which `ssh -G`
#    reads from ~/.ssh/config: it's often not 22 in a container (7878 on one Kubernetes cluster).
MASTER_ADDR=$(grep -v '^#' "$HOSTFILE" | grep -v '^$' | head -1 | cut -d' ' -f1)
PEER=$(grep -v '^#' "$HOSTFILE" | grep -v '^$' | sed -n 2p | cut -d' ' -f1)
SSH_PORT=$(ssh -G "$MASTER_ADDR" | awk '$1 == "port" {print $2}')
ssh -n "${PEER:-$MASTER_ADDR}" "timeout 5 bash -c 'echo >/dev/tcp/$MASTER_ADDR/$SSH_PORT' && echo OPEN"

On Kubernetes, ssh may be kubectl exec per pod — still loop every sibling, not only the first (-0). Probe sshd listen port (ss -ltnp | grep sshd) and ssh -p <port> <ip> hostname. Do not assume port 22 or 2222. If PATH has a cluster SSH wrapper, use it; otherwise ssh / pdsh.

Pass: every hostname comes back, TCP to MASTER_ADDR is OPEN. Fail: ask the user (hostfile IPs, SSH port, keys, pdsh args) and wait. Do not start MAMF “in the meantime.”

Keep hostfile-map.txt in the eval directory, and copy it into raw/ when you create the report: every <host>(node<I>) in the report comes from it, node<I> from its first column and <host> from its last. Pass also needs one row in it per hostfile line; a FAIL: ssh <ip> line names the peer the loop stopped at. With kubectl exec instead of ssh, write the same file from each pod's hostname -s, in hostfile order. On 1 node there is no hostfile, and the node is node0.

After the eval venv exists (loop step 2), add one more cheap check before GPU inter-node all-reduce: CPU-only, 1-process-per-node PyTorch gloo backend, init_process_group + all_reduce (see Network). Still not torch-dist-bench.py.

Loop

  1. Preflight. Fill the checklist. Ask for what’s missing (hostfile with peer IPs is required for ≥2 nodes; 1 node needs no hostfile). Stop until the user answers. Then, if ≥2 nodes, run the SSH/TCP reachability probes. Do not start the isolated install or any long bench until that passes (1-node evals skip the probes and skip inter-node entirely).
  2. Dump environment (below) into the report draft.
  3. Isolated venv on the newest released torch (do not mutate or benchmark the node’s preinstalled Python).
  4. If ≥2 nodes: CPU gloo 1-process-per-node across the hostfile (connectivity + rdzv). Fix is_host / local_addr here if needed. Skip this step on 1 node.
  5. Connectivity: torch-distributed-gpu-test.py — one process per GPU; ranks must see each other and complete a collective. The scope is whatever you launch it on: across all nodes it is an inter-node check, on a single node it is only intra-node. With ≥2 nodes, run it across all of them — a 1-node run does not test the fabric and must never be labelled inter-node.
  6. Compute: the lemon GEMM first, on every GPU of every given node — it takes seconds and is a gate: a dead or grossly slow card stops the Compute phase there (see Lemon GEMM). Then dcgmi diag -r 2 (hardware health), mamf-finder-all-gpus.py (one GPU at a time while every other GPU runs a continuous matmul), then, after 2 minutes with every GPU idle, gpu-straggler-finder.py on all of them at once.
  7. Network: intra-node torch-dist-bench.py --collectives all --separate-tables — all-reduce bandwidth plus the per-call latency of every collective, in one run. Then, if ≥2 nodes, the same on all of them (not a fixed 4). If 1 node, stop after intra-node — no Inter-node heading.
  8. Storage: fio-scan on local disk and on every unique shared partition (one per type and size, see Storage). With ≥2 nodes, on each partition scanned, a 1 GiB dd from node0 alone and then from every given node at once; skip the dd on 1 node.
  9. Write reports/<cluster>-<YYYY-MM-DD-HHMM>.md next to this skill (or in the working directory), with reports/raw-<name>/ beside it and plots inlined. Write it for a reader who knows nothing you learned on the node: every tool and term gets defined where it is first used. End with ## Findings, split into ### Healthy subsystems, ### Underperforming subsystems, and ### Needs operator input — the last for subsystems measured cleanly but with no known target to judge them against; keep only the headings that have bullets. Compute may use % of official TFLOPS. Intra-node all-reduce may use % of NVLink spec (note NVLS). Latency has no vendor target, so it goes under Needs operator input (see Latency). Storage: measured vs vendor advertised. Never flag multi-node all-reduce as “X% of NIC / rail spec.” Do not repeat the tables.
  10. Clear the scratch you created (see Leave the filesystems as you found them) — before the summary, not after the user notices.
  11. Close-out: ask the user to address each one, including every Needs operator input bullet — those are open questions addressed to them, and the eval stays unfinished until they supply the figures or say to drop it. For every gap: quote it, then give a proposed plan of action (commands, launcher, package, node count, or “accept and leave as-is”). Do not treat the eval as finished until they pick a plan, you execute it, or they explicitly accept the gap. If there are no Gaps sections, say the eval is complete.

Start the GPU performance pass, the lemon GEMM and gpu-straggler-finder.py only on a node with no other compute processes in nvidia-smi; abort if one appears. During mamf-finder-all-gpus.py, a python process on every GPU is the script's own matmul and is expected.

Leave the filesystems as you found them

A storage eval writes enormous scratch files onto shared filesystems that belong to other people. Clearing them is part of the eval, not an optional courtesy — an eval that hands back a report and leaves 165 GiB across five production mounts has cost the cluster more than it measured. The user should never be the one to discover the leftovers.

What this eval creates, all of which has to go:

| what | where | size |

| --------------------------------------- | -------------------------------------------------- | ------------------------------------- |

| fio work files | <scan path>/fio-test/ on every mount scanned | ~33 GiB per mount per six-run scan |

| concurrent-write poke files | each share you wrote to, one per node + node0's alone | 1 GiB × (nodes + 1) per share |

| mamf-finder / bench outputs, job logs | wherever you pointed them | small, but still yours |

| the isolated venv, cloned repos | /tmp or a share | leave only if under node-local /tmp |

Rules:

Isolated install

Always build a fresh venv on the newest released PyTorch that has a wheel for the driver's CUDA. Never benchmark the node’s preinstalled env (conda, the image python3, a dev environment) — it is usually months behind. Torch version decides matmul kernels and NCCL version, so it changes MAMF and every busbw number. "It imports and the CUDA major matches" is not a reason to reuse it.

Newest PyTorch, not newest Python: build the venv with the node's own Python if it is 3.12 or higher, else with 3.12. The newest Python has no binary wheels for many packages yet, so never install one newer than the node has. If the node's Python is older than 3.12, install 3.12 the way the platform does (apt-get install python3.12-venv, uv python install 3.12, conda).

Find the newest PyTorch, do not assume a version from memory:

python3 -m venv "$EVAL_VENV"   # python3 -V >= 3.12, else python3.12; $HOME/venvs/cluster-eval, or shared FS so every node sees it
"$EVAL_VENV/bin/pip" install -U pip
"$EVAL_VENV/bin/pip" index versions torch --index-url https://download.pytorch.org/whl/cu130   # -> LATEST: x.y.z
"$EVAL_VENV/bin/pip" install torch numpy packaging nvidia-ml-py matplotlib \
  --index-url https://download.pytorch.org/whl/cu130

Pick the cuNNN index matching the driver (nvidia-smi); try the highest one the driver supports and fall back if it 404s. The newest PyTorch on PyPI or on a higher cuNNN index can be built for a newer CUDA than the driver runs — a driver for CUDA 13.0 found torch 2.15.0 built only for CUDA 13.2 and 13.4, and 2.14.1 the newest on cu130 — so never install from those; the newest on the driver's index is the one. Record in the report the installed version and that it was the latest on that index at eval time. If the newest wheel cannot be used (driver too old, no matching index), say so in Gaps with the version you settled for — do not quietly benchmark an old torch.

Verify each phase actually ran on it. Every bench prints its stack (- software: torch=…, nccl=…); MAMF logs it too. A launcher can silently substitute its own interpreter — deepspeed/srun run whatever python3 is on the remote PATH, so a run can come back on the node’s old torch even with the venv sourced. Grep the log before you copy a number into the report.

nvidia-ml-py is required (import pynvml) — mamf-finder.py refuses to start without it, because it needs the SM clock to confirm MAMF was a boost burst and the power draw to rank the scouted shapes. Do not pass --telemetry off to get around it; install the package. The pip name is nvidia-ml-py; the import is pynvml.

Host packages — install before the env dump, on every node you will measure. Prefix with sudo if the eval user is not root. Empty ibstat on EFA is OK; still install infiniband-diags and confirm fabric with rdma link / /sys/class/infiniband.

Debian/Ubuntu:

sudo apt-get update
sudo apt-get install -y infiniband-diags fio iproute2 rdma-core pdsh
# DCGM is not in Ubuntu — NVIDIA CUDA repo (after cuda-keyring). Match CUDA major from nvidia-smi:
#   CUDA_VERSION=$(nvidia-smi | sed -E -n 's/.*CUDA Version: ([0-9]+)[.].*/\1/p')
#   apt-get install -y --install-recommends datacenter-gpu-manager-4-cuda${CUDA_VERSION}

RHEL/Rocky:

sudo dnf install -y infiniband-diags fio iproute rdma-core pdsh
# DCGM: NVIDIA CUDA repo, then datacenter-gpu-manager-4-cuda${CUDA_VERSION} (CUDA major from nvidia-smi).

| binary | package | why |

| -------- | --------------------------------------------------------------- | -------------------------------------------------------------------------------------------------------------- |

| ibstat | infiniband-diags | InfiniBand/RoCE NIC (channel adapter) state, rate, LID. Empty on EFA is OK — then rdma link + sysfs rate |

| fio | fio | fio-scan |

| rdma | iproute2 (+ rdma-core) | rdma link |

| pdsh | pdsh | DeepSpeed multi-node launcher / torchrun helper |

| dcgmi | datacenter-gpu-manager-4-cudaN (NVIDIA CUDA repo, not distro) | dcgmi diag -r 2 hardware health |

If apt/dnf is blocked, record that in Gaps and fall back to /sys/class/infiniband/*/ports/*/rate + nvidia-smi topo — that is a last resort, not the default.

The five scripts from Scripts (fetch) must sit in one directory on a filesystem every node can read (shared FS), so fio-scan can call ./fio-json-extract.py.

Environment dump

Capture into the report (datetime in the report's time zone, hostnames):

date -u +%FT%TZ
hostname -s; uname -a
nproc; grep MemTotal /proc/meminfo
. /etc/os-release; echo "$PRETTY_NAME"
"$PY" -V
"$PY" -c "import torch; print(torch.__version__, torch.version.cuda); print(torch.cuda.nccl.version())"
nvidia-smi --query-gpu=index,name,uuid,serial,pci.bus_id,driver_version,memory.total,power.limit,power.max_limit,clocks.max.sm,clocks.sm,power.draw,pcie.link.gen.current,pcie.link.gen.max --format=csv
nvidia-smi topo -m
# fabric (install infiniband-diags / iproute2 first — see Isolated install):
ibstat
rdma link
ls /sys/class/infiniband
cat /sys/class/infiniband/*/ports/1/rate
nvidia-smi --query-compute-apps=pid,used_memory,process_name --format=csv
sha256sum mamf-finder.py mamf-finder-all-gpus.py torch-dist-bench.py gpu-straggler-finder.py

On ≥2 nodes, also save every node's GPU identities, since the UUIDs and serials that the lemon gate and Findings ask for may be on any node: pdsh -w "$HOSTS" "nvidia-smi --query-gpu=index,uuid,serial,pci.bus_id --format=csv,noheader" > gpus.csv, copied into raw/ with the report. On 1 node the --query-gpu line above has them.

Classify intra-node (NVLink vs PCIe from topo) and inter-node (InfiniBand / RoCE / EFA / Ethernet). HBM = memory.total reported in GiB (not MiB). SM clocks in the Environment GPU table: boost = clocks.max.sm (spec / short burst); saturated = SM clock at ~TDP under a dense GEMM (a range is fine; not a single nvidia-smi field); parked idle = clocks.sm when no compute. Do not label boost as “loaded” — a power-saturated GEMM sits well below boost. Do not name MAMF/MSMF in Environment — those terms start in Compute. Write the dump as five tables in the report: Host / GPU / Fabric / Filesystems / Software. Never one mega-table. Software: OS is not here — it is Host row 1. Python version + torch/NCCL. Never the eval venv path (temporal artifact). Tool versions (mamf-finder, …) belong under Compute.

Compute

Introduction

Open Compute with the GPUs that are here (name, count per node, SM count, HBM GiB, TDP, official BF16 TFLOPS + table). Do not start with DCGM or a FLOPS table. Then introduce the four passes as a numbered list (1. … 4.), each with the tool: dcgmi diag -r 2 (NVIDIA's health check), CODE3 (shape search → MAMF burst and MSMF sustainable TFLOPS, both vs spec — do not describe it as burst-only), lemon GEMM (inline script), CODE4 (4 workloads on every GPU at once, each GPU against its node's median GPU and each node against the median node). Headings below are Hardware health, GPU performance benchmarks, Find underperforming GPUs — not the tool nicknames.

Hardware health

Hardware health, not a FLOPS number. -r 1 is seconds of software/deployment only — skip it as a named step. -r 2 is the light hardware suite (GPU memory, memory bandwidth, PCIe/NVLink; NVIDIA: ≲10.5 min on 8 H200s, 13 min on 8 B200s). -r 3 is a longer stress test, optional.

Needs nv-hostengine running and usually CAP_SYS_ADMIN (these trial pods are typically root with it). Start the host engine with sudo when the eval user is not root: started as the user it exits, and dcgmi diag then fails with Unable to connect to host engine and exit 253. If install or diag fails, Gaps and continue with MAMF and the straggler pass.

pgrep -x nv-hostengine >/dev/null || sudo -n nv-hostengine   # drop sudo if root
sleep 3
dcgmi discovery -l
dcgmi diag -r 2 | tee dcgm-diag-r2.txt

One node is the minimum; extra nodes in parallel if you already have them. Report Pass or Fail per plugin and per GPU. If everything passed, write Pass — do not add No Fail. Copy the log off immediately.

GPU performance benchmarks

mamf-finder-all-gpus.py — one GPU at a time, while every other GPU of the node runs a continuous bf16 matmul that holds it at its power limit, as in a real workload:

OUT_DIR=mamf "$PY" mamf-finder-all-gpus.py --dtype bfloat16 > mamf-all.console 2>&1

On 8 H200s it took about 4.5 minutes; on 8 B200s, 9.5 minutes, every node at once.

  1. GPU0 runs the full --search auto: MAMF and MSMF with their shapes (mamf/gpu0.txt, whose Tried N shapes line gives the search size).
  2. Each other GPU in turn measures GPU0's MAMF and MSMF shapes only (mamf/gpu<N>.txt); that is much shorter than a search.
  3. mamf/summary.txt lists each GPU's MAMF and MSMF with shapes, W, MHz and temperature, then for each headline the node figure (the median GPU), the slowest GPU, which synchronous work runs at, and the spread across GPUs.

Every GPU's MAMF and MSMF are measured on the same 2 shapes, so the numbers compare directly; only GPU0's are search results. Compare MAMF and MSMF to official BF16 TFLOPS. A rare GPU's MAMF on GPU0's shape can lose to another shape on that GPU (the summary then shows a different MAMF shape for it); report it as printed.

A hotter than the coolest GPU warning names a GPU whose MSMF window ran 15°C or more hotter than the node's coolest GPU. It is a fact about the node's cooling, not a fault; report it in a sentence below that node's table. If it names the same GPU index on every node, say so: that is the chassis' airflow, not a card — on 4 nodes of 8× B200 it named GPU0 on all 4, and the even-numbered GPUs ran about 10°C hotter than the odd ones in every pass.

One pass cannot call a GPU slow, and a few percent is not slow. Healthy GPUs differ from chip to chip: on healthy 8x H200 and 8x B200 nodes the slowest GPU's MSMF sat 0.9–1.7% below its node median, and a single GPU's MSMF moves by up to 2.2% between passes on top of that, so a healthy GPU can read about 4% below the median in one pass. A GPU is a candidate only if it is more than 5% below the node median MSMF, well beyond that spread. Then rerun the pass twice with the shape pinned — --m M --n N --k K from the summary's MSMF shape, OUT_DIR=mamf-rep2 and mamf-rep3, about 3.5 minutes each on 8 H200s. A GPU is under-performing only if it is more than 5% below its node median in all three passes; report it in Findings as described there. If the dip did not repeat, say so in one sentence with the three numbers, so the reader does not wonder about the first table.

Find underperforming GPUs

An under-performing GPU, a straggler, works correctly but runs slower than its peers, and in any synchronous job — training, or inference with tensor, expert or pipeline parallelism — every GPU waits for it at each collective. It passes DCGM, and the GPU performance pass can miss it: a B200 that made a training step 3–5% slower than its 7 siblings, only some of the time, had a MAMF and MSMF within 1–2% of its node's median, as both report a GPU's best stretch. Two passes, both on every GPU of every given node, not MAMF:

  1. Lemon GEMM — seconds, run first in the Compute phase, before DCGM and the GPU performance pass: a gate for a dead or grossly slow card. Its section stays here in the report.
  2. CODE0 — the verdict, run last: a straggler is a few percent slow, only some of the time, which one fixed matmul with idle siblings doesn't show.

The 3 passes overlap but answer different questions: the GPU performance pass measures whether the GPU model delivers its spec, in absolute TFLOPS; the straggler finder compares each GPU with its peers, so it would call 32 GPUs that are all 20% under spec healthy; the lemon GEMM finds in seconds what would otherwise surface only 15 minutes later, as a failed MAMF or finder run.

A GPU goes to Findings when any of the 3 confirms it: the lemon GEMM's gate (dead, or more than 5% below its node's median in 3 runs), the GPU performance pass (more than 5% below its node's median MSMF in 3 passes), or the finder (flagged in all 4 runs, in the same workload). The bars differ because the noise does: a single MSMF or lemon number moves by a few percent between passes, while the finder divides each GPU's time by its node's median GPU's in the same 2-second window, which cancels what the node's GPUs share, and on 4 nodes of 8× B200 no healthy GPU's 90th percentile step window went above 1.9% in 5 runs - the finder also requires a modified z-score above 3.5, which such a GPU doesn't reach. A GPU that two passes confirm gets one bullet naming both. One that only the finder flags is still under-performing: that is the straggler the other two miss.

Open with TLDR: no under-performing or dead GPUs, or name each one: TLDR: under-performing: <host>(node<I>):gpu<N>, dead: <host>(node<I>):gpu<N>, slow node: <host>(node<I>).

Lemon GEMM

Same large matmul on every GPU, siblings idle. Run it on 1 node or 16.

Fixed 16384³ bf16. Compute SM coverage from this GPU’s SM count (torch.cuda.get_device_properties(0).multi_processor_count) — never reuse an SM count from another GPU family. At 128×256 output tiles that is 8192 CTAs (16384/128 × 16384/256; a CTA is one CUDA thread block). Full waves = 8192 // SMs, tail = 8192 % SMs, wave efficiency = 1 - tail/8192. Example only: 132 SMs → 62 waves + 8 CTA tail (99.9%).

Report it in one sentence when nothing trips the gate: the median of all the GPUs' TFLOPS, the range, and the lowest GPU with how far below its node's median it is. A GPU that trips the gate gets a row with its TFLOPS in each of its 3 runs and its node's median. The per-GPU scores stay in raw/lemon.console. A card more than 5% below its node median goes to The gate below, which decides it; the min of a tight pack is noise.

The gate. A GPU whose run errors, hangs or prints inf/nan is dead. One more than 5% below its node's median GPU is grossly slow if it stays there when the script is run twice more, which takes seconds. Either one stops the Compute phase: put it under Underperforming subsystems, and tell the user which <host>(node<I>):gpu<N> it is, with its UUID and serial from the environment dump, so the node can be fixed or replaced before the long passes. Continue with Network and Storage, which don't depend on it. If nothing trips the gate, go on to DCGM.

Passing the gate doesn't clear a GPU: on 4 nodes of 8× B200 the GPU the finder then flagged in all 4 runs read 4.4% below its node's median here, the lowest of the 32 but under the 5% bar. Name the lowest GPU in that sentence, with how far below its node's median it is, so the reader can match it against the finder's verdict.

Stragglers

gpu-straggler-finder.py runs 4 workloads on every GPU of every node at once, with no communication between the GPUs while it times them: a Llama-3.1-8B training step (its 32 decoder layers on one 8192-token sequence, forward and backward, each step followed by a 100 ms idle) for 60 s, then for 30 s each a back-to-back matmul (8192³ bf16), a device-to-device cudaMemcpy and a kernel adding 2 HBM buffers into a third. It cuts each workload into 2 s windows and divides every GPU's time by its node's median GPU's in the same window, and compares each node's median GPU with the median node's. pip install nvidia-ml-py in the eval venv first, for its clock, power and temperature columns; without it only the timings are reported.

On ≥2 nodes, set up first, from the shared directory the scripts are in. MASTER_ADDR, HOSTS and HOSTFILE are the ones from Inter-node reachability; in a new shell, derive them again the same way.

export PDSH_RCMD_TYPE=ssh
EVAL=$(pwd -P)
NGPU=$(nvidia-smi -L | wc -l)
NNODES=$(grep -v '^#' "$HOSTFILE" | grep -vc '^$')
# gloo's interface: the one that carries each node's hostfile IP. If its name differs between nodes, ask the user.
pdsh -w "$HOSTS" "ip -o -4 addr show"
[ -n "$GLOO_IFACE" ] || echo "STOP: set GLOO_IFACE to the interface the line above shows the hostfile IPs on"
# --hostfile-to-sort writes <file>-fast-to-slow next to the file it is given: give it a copy, never the platform's hostfile
cp "$HOSTFILE" "$EVAL/hostfile"

Don't go on until GLOO_IFACE is set. Then run one of the 2 forms below. Each starts with 2 minutes with every GPU idle, right before the launch, as a straggler can be slow only in the first 20-25 s after the load starts from idle:

# 1 node; --unflagged-rows -1 keeps every GPU's row in the console, the raw record the report links to.
# Without torchrun it exits 3 if it flagged a GPU and 2 on inf/NaN: that is its verdict, not a failed run.
sleep 120
"$PY" gpu-straggler-finder.py --unflagged-rows -1 --json straggler.json > straggler.console 2>&1
# ≥2 nodes: the same command on every node at once, under torchrun; it gathers the results on rank 0 over gloo
sleep 120
pdsh -w "$HOSTS" "cd $EVAL && GLOO_SOCKET_IFNAME=$GLOO_IFACE $PY -m torch.distributed.run --nnodes $NNODES \
  --nproc_per_node $NGPU --rdzv_backend c10d --rdzv_endpoint $MASTER_ADDR:29500 --max_restarts 0 \
  gpu-straggler-finder.py --unflagged-rows -1 --json $EVAL/straggler.json --hostfile-to-sort $EVAL/hostfile" \
  > straggler.console 2>&1

If any node's own hostname resolves to 127.0.1.1 (getent hosts $(hostname) on it), add --rdzv_conf is_host=… --local_addr … as in is_host / local_addr.

Each verdict line names a GPU as <host> GPU <N>, and the table rows give the host and the index in their own columns: <host> is the node's hostname, to match against hostfile-map.txt up to the first ., which gives its node<I>, and <N> is the nvidia-smi index, since the finder matches GPUs by UUID. After a run on ≥2 nodes in which no GPU returned inf/NaN, it ends with the nodes ranked by the pace of a job that runs their GPUs in lockstep: the nodes that passed, fastest first, then every node with a flagged GPU, or flagged itself. It writes the hostfile's lines in that order to $EVAL/hostfile-fast-to-slow, so its first N lines are the N fastest nodes that passed, if at least N passed. Copy that file into raw/ with straggler.json and straggler.console. Two messages mean that the hostfile and the nodes the finder measured disagree - a node missing from the run, or a hostfile IP that no node owns: left out N line(s) of <file> that name no node measured, ... and no line of <file> names <host>, .... Put each in Gaps. The stall lines' "left out of that node's comparisons" is not one of them.

One run took 3 min 10 s on 4 nodes of 8× B200. Under torchrun its exit code is always 0; the verdict is the framed banner in the report it prints: No Stragglers Found, or Stragglers Found: with the number of flagged GPUs and slow nodes, followed by one line per flagged GPU or node, with what it was flagged for, its numbers, and its UUID, serial and PCI bus id. A GPU is flagged when its 90th percentile window in a workload is above a modified z-score of 3.5 among all the GPUs and more than 1% slower than its node's median GPU, (slow), or when its 90th percentile window is more than 1.25% slower than its own median window, also above a modified z-score of 3.5 (unsteady: slow only some of the time); a node when its median GPU is more than 3% slower than the median node's.

One run cannot call a GPU under-performing either. If the first run flags anything, run it again with --repeat 3, 12 minutes on 4 nodes of 8× B200, writing its own files so that the first run's survive: the verdict needs all 4 runs. --repeat-idle idles only between its runs, so idle before the first one too. With ≥2 nodes:

sleep 120
pdsh -w "$HOSTS" "cd $EVAL && GLOO_SOCKET_IFNAME=$GLOO_IFACE $PY -m torch.distributed.run --nnodes $NNODES \
  --nproc_per_node $NGPU --rdzv_backend c10d --rdzv_endpoint $MASTER_ADDR:29500 --max_restarts 0 \
  gpu-straggler-finder.py --unflagged-rows -1 --repeat 3 --repeat-idle 120 --json $EVAL/straggler-repeat3.json \
  --hostfile-to-sort $EVAL/hostfile" > straggler-repeat3.console 2>&1

On 1 node: sleep 120; "$PY" gpu-straggler-finder.py --unflagged-rows -1 --repeat 3 --repeat-idle 120 --json straggler-repeat3.json > straggler-repeat3.console 2>&1. Copy both files into raw/. Instead of a banner per run it prints one, Stragglers Found in 3 Runs: with the GPUs flagged in all 3 and in some, or No Stragglers Found in 3 Runs. Its "in some" also counts the GPUs that were only slower than in their own fastest run, and its "all 3" leaves out the first run, so take the 4-run verdict from straggler.json and straggler-repeat3.json together. Its sorted hostfile ranks each node by its slowest of the 3 repeat runs and overwrites $EVAL/hostfile-fast-to-slow; copy it over the one in raw/. A GPU or node is under-performing only if it was flagged in all 4 runs, in the same workload; report it in Findings as described there. One flagged in some of the runs goes in this section only, in one sentence with the runs it was flagged in and its numbers in each. On 4 nodes of 8× B200 a GPU 3.3% slow in the matmul alone, at the lowest matmul clock of the 32 under the power cap and normal in the step, was flagged in 2 runs of 4.

```bash

report=straggler-$(hostname -s)

sleep 120

nsys profile --trace=cuda,nvtx --gpu-metrics-devices=all -o "$report" "$PY" gpu-straggler-finder.py \

--unflagged-rows -1 > "$report.console" 2>&1

nsys export --type sqlite --output "$report.sqlite" "$report.nsys-rep"

```

The GPU_METRICS clock values in the .sqlite are in Hz despite the [MHz] in their name. Use this run for the clocks only, not for its verdict: nsys slows the GPUs unevenly, and on a node of 8× H200 that passed 4 runs without it, its step was 2% slower and 3 GPUs were flagged slow in it at +1.3-1.7%. Copy the .nsys-rep, the .sqlite and the .console into raw/; for 8 GPUs they were 0.6 GB and 19 GB, and the export took 6 minutes. If nsys says the GPU performance counters are in use, stop nv-hostengine, which DCGM may have left running, and run it again. If nsys isn't installed, put it in Gaps.

Network

Ask which NCCL/platform env vars to set. Dump first (env | grep -E '^NCCL_|^FI_|^AWS_OFI'). Keep platform values. Default only if unset: NCCL_NVLS_ENABLE=2. If NCCL_TUNER_PLUGIN=ofi (or similar), a platform tuner — not NCCL’s built-in tuning.cc — picks the algorithm; confirm with NCCL_DEBUG. pdsh does not copy the launcher’s environment — put overrides in ~/.deepspeed_env and source them in the remote command, or embed VAR=val in the pdsh cmd. --venv_script run-env.sh is the DeepSpeed equivalent. DeepSpeed can drop exports from --venv_script; ~/.deepspeed_env (one KEY=VALUE per line, in the launch cwd) is the reliable file. --venv_script does not switch the Python interpreter — DeepSpeed still launches whatever python3 is on the runner PATH (often the node’s old install). Put the eval venv first on PATH inside run-env.sh and invoke deepspeed from that venv ($EVAL_VENV/bin/deepspeed or PATH=$EVAL_VENV/bin:$PATH deepspeed …). Confirm the table’s torch= / nccl= line matches the isolated install.

Connectivity first (torch-distributed-gpu-test.py — ranks must init NCCL and finish a collective). The heading and TOC label must match the ranks you actually launched: Inter-node connectivity only when it ran across every node, Intra-node connectivity for a single-node run. On ≥2 nodes use the same launcher as inter-node all-reduce (deepspeed -H, pdsh, …) with one rank per GPU; the snippet below is the 1-node form.

"$PY" -m torch.distributed.run --nproc_per_node="$NGPU" --rdzv_endpoint localhost:6000 --rdzv_backend c10d \
  torch-distributed-gpu-test.py

Intra-node (header of CODE0):

"$PY" -u -m torch.distributed.run --nproc_per_node="$NGPU" --rdzv_endpoint localhost:6000 --rdzv_backend c10d \
  torch-dist-bench.py --collectives all --separate-tables

--collectives all times all nine collectives (all_reduce first), each from 8 B to 16 GiB; on one 8x B200 node they take under 2 minutes, on 4 nodes about 3. The all_reduce table is the all-reduce benchmark below; the per-call latency of all nine is the latency benchmark (see Latency).

Inter-node (≥2 nodes, all of them). Let NNODES = hostfile length, NGPU = GPUs per node, ranks = NNODES * NGPU. 1 node: omit this whole subsection — no heading, no “Skipped: 1 node”. Do not discover a missing hostfile here — that was the preflight gate. Use whatever launcher this cluster already has (deepspeed -H <hostfile>, pdsh, srun, or a site SSH wrapper). Reachability (SSH/TCP) already passed; this section is the GPU torch-dist-bench.py --collectives all --separate-tables sweep only. Its results go in the same ### All-reduce benchmark and ### Latency benchmark sections as the intra-node ones (ranks go in the TOC annotation, not the heading).

Hostfile: skip # comments. MASTER_ADDR = first data line, not a comment. If the platform already ships a hostfile, read it, never edit it.

1. DeepSpeed (from the shared cwd that contains the bench):

# run-env.sh: source the eval venv; re-export the NCCL values you dumped (do not invent 2 if the platform set 1)
time deepspeed -H "$HOSTFILE" --venv_script run-env.sh torch-dist-bench.py --collectives all --separate-tables \
  |& tee torch-dist-bench-deepspeed.log

Requires passwordless SSH from the launch node to every hostfile IP. Port is cluster-specific (a wrapper on PATH may already add -p). If ssh hits the machine sshd (not the container), start sshd in the container on an unused port, put the launch key in each container authorized_keys, and set PDSH_SSH_ARGS_APPEND="-p <port> -o StrictHostKeyChecking=accept-new". Ubuntu pdsh (used by DeepSpeed) may refuse to load modules when /usr/lib is not root-owned on overlay — sudo chown root:root /usr/lib on the launch node if you are not root.

pip install matplotlib in the eval venv on shared FS so every node can plot; otherwise only the intra-node (single-node) plot appears.

2. pdsh + torch.distributed.run (pdsh does not forward env):

GPUS_PER_NODE=8
NNODES=$(grep -v '^#' "$HOSTFILE" | grep -vc '^$')
MASTER_ADDR=$(grep -v '^#' "$HOSTFILE" | grep -v '^$' | head -1 | cut -d' ' -f1)
MASTER_PORT=6002
HOSTS=$(grep -v '^#' "$HOSTFILE" | grep -v '^$' | cut -d' ' -f1 | tr '\n' ',' | sed 's/,*$//g')
cwd=$(pwd)

# If getent hostname is 127.0.1.1, add to the remote cmd:
#   MYIP=\$(hostname -I | awk '{print \$1}');
#   IS_HOST=\$([ \"\$MYIP\" = \"$MASTER_ADDR\" ] && echo 1 || echo 0);
#   --rdzv_conf is_host=\$IS_HOST --local_addr \$MYIP
cmd="source $cwd/run-env.sh; \
python -u -m torch.distributed.run \
    --nproc_per_node $GPUS_PER_NODE \
    --nnodes $NNODES \
    --rdzv_endpoint $MASTER_ADDR:$MASTER_PORT \
    --rdzv_backend c10d \
    --max_restarts 0 \
    --role \$(hostname -s): \
    --tee 3 \
    $cwd/torch-dist-bench.py --collectives all --separate-tables"

PDSH_RCMD_TYPE=ssh PDSH_SSH_ARGS_APPEND="-o StrictHostKeyChecking=accept-new -o BatchMode=yes" \
  pdsh -w $HOSTS $cmd |& tee torch-dist-bench-torchrun.log

--role \$(hostname -s) must expand on the remote, not on the launch node. MASTER_ADDR must be an IP other nodes can TCP to (rdzv).

`is_host` / `local_addr`: only when hostname ≠ routable IP

Probe first: getent hosts "$(hostname)" and _matches_machine_hostname(MASTER_ADDR) on the endpoint node. If hostname already maps to the pod/node IP, omit --rdzv_conf is_host and --local_addr. Add them only when hostname is 127.0.0.1 / 127.0.1.1 or _matches_machine_hostname is False on the node that owns the endpoint.

When needed, two independent failures look like a TCPStore timeout:

  1. Nobody hosts the store. With no is_host, each agent calls _matches_machine_hostname(endpoint_host) (CODE2), which only compares the endpoint against IPs from resolving socket.gethostname(). When the hostname maps to 127.0.1.1, that is False on the node that owns the endpoint IP, so every agent starts as a client, nothing ever listens, and all nodes — the master included — time out. is_host=1 on the endpoint node forces the TCPStore server (it binds *:PORT).
  2. Workers get an unresolvable master. Rendezvous then advertises the host agent's hostname as MASTER_ADDR. Workers that cannot resolve it retry forever with [c10d] The IPv6 network addresses of (<hostname>, <port>) cannot be retrieved (gai error: -2 - Name or service not known). --local_addr $MYIP makes each agent advertise its IP instead.

Diagnose in this order, do not guess at the fabric — TCP already works if DeepSpeed runs:

# 1. does the endpoint node think it is the host?
python -c "from torch.distributed.elastic.rendezvous.utils import _matches_machine_hostname as m; print(m('$MASTER_ADDR'))"
# 2. with is_host=1, does the store bind?           -> expect *:PORT
ss -ltnp | grep "$MASTER_PORT"
# 3. can a worker reach it?                          -> expect OPEN
timeout 5 bash -c "echo > /dev/tcp/$MASTER_ADDR/$MASTER_PORT" && echo OPEN
# 4. is the advertised master resolvable everywhere?
getent hosts "$(hostname)"      # 127.0.1.1 => you need --local_addr

Verify with a CPU-only, 1-proc-per-node gloo script (init_process_group + all_reduce) before spending GPUs; it isolates rendezvous from NCCL. --rdzv_conf timeout=60 keeps a failed attempt short instead of the 600 s default. Symptom cheat sheet: nothing listening anywhere → problem 1; store listening, workers log gai error: -2 → problem 2.

Transport detection

Do this before quoting any all-reduce number. busbw is already unidirectional (directionality). Tables: intra-node, NVLink gens, inter-node / adapters.

Intra-node — the only place “% of spec” is a wire comparison (NVLink/PCIe). NVLS can push ring-formula busbw past 100% of that spec; say so.

nvidia-smi topo -m          # NV18 = 18 NVLink bonds; PHB = PCIe host bridge (no NVLink)
nvidia-smi nvlink -s        # per-link GBps; ×0.94 ≈ advertised (encoding)

Map NVLink gen from per-link payload rate (or GPU family): ~53 GBps/link → NVLink 5 (900 GBps unidirectional, B200-class); ~26.5 → NVLink 4 (450, H100/H200-class); slower ~12.5-class is older NVLink (table). NV# in topo is bonded link count. No NV* → PCIe; use pcie.link.gen.max (Gen5 x16 ≈ 63 GBps uni). Intra-node all-reduce % = peak_busbw / spec_uni * 100 (NVLS can exceed 100% of the wire formula — note that).

Inter-node

ls /sys/class/infiniband/                 # mlx5_* IB/RoCE; rdmap* EFA
cat /sys/class/infiniband/*/ports/1/rate  # e.g. 200 Gb/sec (EFA) or 800 Gb/sec (CX-8)
rdma link
ibstat   # may print **nothing** on EFA — that is not “no fabric”; use rdma link + sysfs
nvidia-smi topo -m                        # NIC legend when present

Identify adapter (AWS EFA + fi_info -p efa, NVIDIA ConnectX-7 NDR, ConnectX-8 XDR, …) from rate + name. Rail-optimized fabrics often put one NIC per GPU; count ls /sys/class/infiniband | wc -l / GPU count and record as inventory, not a busbw denominator. “Rail” here means one NIC lane per GPU, not a score.

Do not score multi-node all-reduce against the NIC spec — not in the Network section, not in Findings.

NNODES ≥ 2 torch-dist-bench.py busbw is always mixed: intra-node NVLink + inter-node NIC + (usually) NVLS/SHARP. Advertised per-GPU IB/RoCE/EFA GBps is inventory. It cannot be measured in isolation with this collective, NVLS on or off. NVLS is in-network all-reduce on the NVSwitch (~30% intra / ~25% inter vs ring busbw) and does not help other collectives.

Forbidden (do not score multi-node all-reduce as a fraction of NIC rate — that mixed NVLink+NIC+NVLS number is not “% of rail”):

Quote instead: peak busbw, NCCL path (IB vs Socket; NVLS yes/no), NIC inventory on the Environment / transport line, and optionally multi-node busbw vs 1-node all-reduce at the same payload (scale-out tax). Record NCCL_NVLS_ENABLE and other NCCL env.

Report template must include: transport + version, NIC inventory GBps, measured peak busbw, NCCL path — not “% of NIC spec.”

Latency

The same --collectives all --separate-tables run gives the per-call latency of every collective: one table per collective with the latency median, p99 (99th percentile) and mean per payload, each call's time being the slowest rank's; then a summary table and latency-collectives-<host>-<ranks>.png, which plots all nine. Copy that plot off with the others.

Do not let all-reduce stand for latency. NCCL gives only all-reduce its tree algorithm, whose latency grows with the log of the node count while the rings of the other collectives grow linearly, and with NVLS or InfiniBand SHARP a small all-reduce can be reduced inside the switch, so on some clusters it has the lowest small-payload latency of all. On others it has nearly the highest: on 4 nodes of 8× B200 with EFA and NCCL_NVLS_ENABLE=1, an 8 B all-reduce took 23.5 µs within a node, the highest of the nine, against broadcast's 11.4 µs, and 76.0 µs over the 4 nodes, against broadcast's 24.5 µs. Which collective is fastest is a property of the cluster, so never assume it in the report: report all nine, and say in the report what the main ones show — which collective to measure latency with:

PyTorch runs batch_isend_irecv through its point-to-point path and scatter as separate NCCL sends, while nccl-tests makes one NCCL call for each, so these two can read higher than nccl-tests would on the same cluster. Say so next to their numbers.

One table for both scopes: | collective | intra-node<br>median (µs) | inter-node<br>median (µs) | inter/intra<br>× | at the smallest payload, named in the row of a collective that splits it (see below) — <br> inside the single header row keeps it narrow enough for PDF, which can't scroll sideways. At that payload a call's time is nearly all latency: on 8x H200 every all-reduce up to 512 KiB took 15–23 µs. inter/intra × is the inter-node median ÷ the intra-node median of the same collective at the same payload — how many times longer a call takes once it leaves the node. Inline the latency-collectives-… plot of each scope.

all_gather, reduce_scatter, all_to_all, gather and scatter split the payload across the ranks, so their tables start above 8 B — at 128 B on 8 ranks. Use the smallest payload each one ran in the 8 B columns and name it in the row, e.g. all_gather (128 B), rather than leaving the cell empty.

Latency has no target. No vendor publishes collective latency figures, so never write "% of spec" and never call latency healthy or underperforming. It goes under Findings → Needs operator input: a link to the latency table, not its numbers again, and what to tell the agent — the provider's expected latency for this fabric at this node count, or the path to a torch-dist-bench.py --collectives all console from a known-good cluster of the same fabric and node count, which the agent then compares collective by collective.

Storage

Introduction

Open Storage with ### Existing Partitions first, then ### Introduction. They are sibling headings, not nested. Never open with a fio table.

Report what you did, not what you didn't. A mount you list for inventory needs its path, type and size — not "not fio-scanned", "not benchmarked", "not tested". The reader assumes anything without a measurement wasn't measured; spelling it out adds a negative to every line and buries the results. Same for tests that were never part of the plan. Never assert an absence — no Skip reasons: none, no ### Gaps / None, no N/A rows, no "nothing was skipped". If it isn't there, it isn't there; the reader can see that. When a required phase genuinely could not run, the reason goes in ### Gaps and nowhere else.

Never report how full a partition is — no Use%, no "X% full", no "N T free", nowhere in the report (not the Storage table, not the intro paragraphs, not Findings). It is a snapshot of what other tenants happened to be storing that hour, it has nothing to do with whether the hardware performs, and it will be wrong by the time anyone reads it. From df take only size, type, path, and server/device.

Shared network filesystems are many different products. Report the one this allocation uses. df -T is the guest-visible type (protocol or native FS); that may or may not be the vendor product. If the type is a share protocol rather than the product (common with virtiofs: project, kernel), recover the product from mount tag (findmnt SOURCE, /sys/fs/virtiofs/*/tag when it is virtiofs), pod volumes (hostPath vs PVC), node CSI annotations, and vendor docs — then link those docs. Advertised bandwidth may sit in the intro as product inventory. Measured vs advertised belongs in Findings → Underperforming subsystems, not here — or in Findings → Needs operator input when no advertised figure is known.

Decide which shared mounts to scan by grouping them, and scope every claim to the mount it came from. Managed parallel filesystems are usually provisioned per TiB of capacity, so a 2 TiB share and a 25 TiB share are not the same product at a different size — they have different expected rates, and a result from one does not transfer to the other. Group the rows of your inventory by (backing type, size):

After scanning, group tables by measured equivalence, not by impression: two mounts are equivalent only if every corresponding bandwidth and IOPS cell (16 KiB / 1 MiB / 1 GiB × read/write) differs by at most 5%. Use abs(a-b) / min(a,b) × 100 so the test is symmetric. Equivalent mounts share one table whose heading lists every mount and size; mounts that fail even one cell get separate tables. State the rule and whether any mounts grouped. Never average across mounts, never present one mount's table as "the shared FS", and never ask the operator for expected figures for mounts you did not measure.

On a parallel FS, capture the layout while you are on the node — it is the difference between a number and an explanation. A single-client fio-scan result is capped by how many storage targets the file is spread over, so collect it in the same pass as the scan and keep it in raw/: on Lustre lfs df -h <mount> (how many OSTs and their sizes) and lfs getstripe -d <scan dir> (default stripe count and size); the equivalents are mmlsdisk / mmlsfs on GPFS, beegfs-ctl --getentryinfo on BeeGFS, nfsstat -m for NFS mount options. Stripe count 1 with a fast fabric and a slow result is the finding, not a mystery. Without it you can only ask the user to explain their own numbers.

Published recipe is 3 min runtime (fio-scan default, ~18 min/mount). First-pass trial may pass FIO_RUNTIME=60 only if you edit a copy of fio-scan — never silently change the published script. Run twice: NVMe path, then shared path. --unlink=1 is already in the script; do not reuse leftover fio files.

Every hand-rolled fio command needs --unlink=1, and every scan leaves scratch behind if it doesn't. --numjobs=16 --filesize=1g writes 16 GiB per run, so one six-run scan is ~33 GiB per mount — five mounts is 165 GiB of other people's storage, on filesystems that are often nearly full. fio-scan passes --unlink=1 for exactly this reason; the moment you inline your own fio loop (to sweep several mounts, to add a size) that flag is the first thing to carry over. Verify with du -sh <scan dir> after the first run rather than at the end of a 90-minute sweep.

./fio-scan "$NVME_PATH"
./fio-scan "$SHARED_PATH"

Need python on PATH for fio-json-extract.py, or patch the copy to python3.

Always format the report tables the same way for the shared core columns (local NVMe and every shared FS group). They must be comparable at a glance:

Report template

Assume the reader knows nothing you learned during the eval. Before any number, say what the tool literally did — what it ran, how many times, what it varied. Never let a term appear that the report has not defined, and expand every acronym at its first use (MAMF, MSMF, DCGM, NVLS, GEMM, busbw, algbw): "any shape" is meaningless until the reader has been told the tool searches matmul shapes (M×N×K); the same goes for O_DIRECT, CTA/wave, local/shared ×. Write the definition where it is first used, not in a glossary the reader has to hunt for. If a sentence only parses because you watched the run, rewrite it.

Cut phrases that carry no information. "and collects the results into one table", "the results are shown below", "for reference", "as expected", "it is worth noting", "this section covers…" — the reader can see the table; saying it exists adds nothing. Every sentence must add a fact, a definition, or a consequence. If deleting it loses nothing, delete it.

Detail what is abnormal; keep what is normal to one line. The report has to read the same on 4 GPUs and on 1000, so never give a row to each GPU or each node whose result is normal. For a per-GPU or per-node measurement write the median and the range, with where the lowest and highest are, and give rows only to the outliers: what was flagged, failed, crossed a candidate bar, or is the lowest of a pass a later pass flags. An abnormal item gets everything: its numbers in every run, the bar it crossed, its identifiers. A healthy subsystem gets one sentence. The full per-GPU and per-payload data stays in raw/, and the section links it. More words and numbers are not more information: a 32-row table of normal GPUs hides the one that isn't.

reports/<cluster>-<YYYY-MM-DD-HHMM>.md plus reports/raw-<name>/ (consoles, txt, fio json, plots), next to this skill or in the working directory. Example: h200-2026-09-17-1238.md.

Times are in the time zone of the machine the agent runs on: TZ if it is set, otherwise that machine's system zone (date +%Z), not the nodes', which are often UTC. The filename's start time and the Datetime line use it, and the line names it, e.g. 2026-09-17, 12:38 PM to 2:51 PM CST. Logs print node time, so convert their timestamps before quoting them.

### Gaps under Compute, Network, or Storage: omit the subsection entirely when that phase is complete. Never write ### Gaps / None. Only include it when something is actually missing or incomparable (busy siblings, lemon GPU, DCGM -r 2 failed/unprivileged, rdzv failed on ≥2 nodes, fio missing, …). 1 node is not a gap — inter-node is omitted, not missing. When the rest of the report is written, ask the user to address every remaining Gaps item, each with a proposed plan of action (loop step 9).

# Cluster eval: <name> (<N> nodes of <G>× <GPU>)

Example titles: `4 nodes of 8× H200`, `1 node of 8× B200`, `16 nodes of 8× H100`. Always include **node count and GPUs per node**, not only the GPU name.

- Datetime (start to end, in the zone above, named):
- Access:
- Nodes / GPUs:

Then a one-line pointer to the raw logs directory: `Raw logs: [\`raw-<name>/\`](raw-<name>/).`

## Table of Contents
Numbered list **before Environment**. Each item is **topic — tool/test that ran**, linking to that heading (GitHub-style `#anchor`: lowercase, punctuation stripped, spaces to `-`). Duplicate titles (`### Introduction`) get `-1`, `-2` suffixes; prefer linking the unique bench heading, not the intro. Only list tests that actually ran (plus inventory).

Compute TOC links are **purpose**, tools after the dash. Do **not** use DCGM / MAMF / Lemon GEMM as the TOC link text; those names live in the annotation or the section body. The `###` headings must match the TOC labels so the anchors agree.

The connectivity test has no section of its own — its result is item 1 of the Network `### Introduction`, so that TOC line links to `#introduction-1` (the second `### Introduction` in the document). Label it by the ranks it actually ran on: **Inter-node connectivity** only if it spanned every node, otherwise **Intra-node connectivity** with the rank count.

Network TOC: **All-reduce benchmark** and **Latency benchmark** — `torch-dist-bench.py`, then the rank counts (and "every collective" for the latency one). Do not drop the word **benchmark**. On 1 node only 8 ranks.

Storage TOC: **Existing Partitions** — mount inventory. Then **Local disk IO benchmark** — `fio-scan` on `<local path>` and **Shared <product> IO benchmark** — `fio-scan` on `<shared path>[, <shared path>…]` (same shape; paths after `on`, never inside the link). Concurrent poke when ≥2 nodes: **Concurrent write shared fs benchmark** — 1 GiB `O_DIRECT` `dd` from node0 alone, then from all `<N>` nodes, on each share.

Example:

Table of Contents

  1. Environment — host, GPU, fabric, mounts, software (inventory, not a bench)
  2. Compute

1. Hardware health — dcgmi diag -r 2

2. GPU performance benchmarks — mamf-finder-all-gpus.py, one GPU at a time while the others run a matmul

3. Find underperforming GPUs — fixed 16384³ matmul on every GPU, then gpu-straggler-finder.py on all 32 at once

  1. Network

1. Inter-node connectivity — torch-distributed-gpu-test.py, R ranks (label it Intra-node connectivity if it only ran on one node)

2. All-reduce benchmark — torch-dist-bench.py, 8 ranks and 32 ranks (only 8 on 1 node)

3. Latency benchmark — torch-dist-bench.py, 8 ranks and 32 ranks, every collective

  1. Storage

1. Existing Partitions — mount inventory

2. Local disk IO benchmark — fio-scan on /tmp

3. Shared Lustre IO benchmark — fio-scan on /code, /data

4. Concurrent write shared fs benchmark — 1 GiB O_DIRECT dd from node0 alone, then from all 4 nodes, on each share (omit if 1 node)

  1. Findings

1. Healthy subsystems

2. Underperforming subsystems (omit if nothing underperformed)

3. Needs operator input (omit if every target was known)


Rebuild the anchors from the headings you actually wrote. Omit TOC lines for phases that did not run — no placeholder line saying they are missing.

## Environment
Five small tables — **Host / GPU / Fabric / Filesystems / Software**. Do not pile every field into one table. The third and fourth are **Fabric** and **Filesystems**, never “Network” / “Storage”: those would take the `#network` / `#storage` anchors the top-level sections need.

### Host
**First row, on a cloud: the instance type**, since the provider's specs (local storage, NICs) are published per instance type: on Kubernetes the node label `node.kubernetes.io/instance-type` (`kubectl get node <node> -o jsonpath='{.metadata.labels}'`), otherwise the metadata service (`curl -s 169.254.169.254/latest/meta-data/instance-type` on AWS). **Then Ubuntu** (`PRETTY_NAME`, e.g. 24.04.2 LTS). Then hostname, kernel (`uname`), CPU cores/NUMA, host RAM. Not Python, not PCIe (it is the GPU ↔ NIC leg of the fabric, see **Fabric**).

### GPU
name × count, SM arch / SM count, HBM in **GiB only** (not `275040 MiB (268 GiB)`), driver / CUDA, **three** SM clocks — boost (`clocks.max.sm`), saturated (~TDP under dense GEMM), parked idle — power limit / idle draw. Do not merge boost and “loaded”; a dense GEMM is not at boost. No MAMF/MSMF names here. PCIe does **not** go here.

### Fabric
intra-node fabric + spec uni GBps; inter-node adapter + rate as **inventory** (`ibstat` / `rdma link`); and a **GPU ↔ NIC (PCIe)** row, the leg every inter-node byte crosses: how many GPUs and NICs share each PCIe switch, so how many NICs each GPU has on its own switch, the gen × width of the GPU and NIC links, and the NUMA node of each group. Read it from sysfs, not from `nvidia-smi topo -m`, which lists only the NICs of drivers it knows: on AWS P6 it showed the 2 InfiniBand ports and none of the 8 EFA NICs, so every GPU looked `SYS`-far from a NIC. For each GPU (`nvidia-smi --query-gpu=index,pci.bus_id,pcie.link.gen.current,pcie.link.width.current`) and each `/sys/class/infiniband/*`, `readlink -f` the PCI device: the paths that share a parent bridge are on one switch; `current_link_speed`, `current_link_width` and `numa_node` sit next to it. Save the list in `raw/pcie-map.txt`. A NIC with fewer lanes than its port rate needs (100 Gb/s on gen 4 ×2) or GPUs with no NIC on their switch go in **Gaps** if the job's traffic uses them.

### Filesystems
Left column **Local** / **Shared network FS** — do not repeat “local” or “ceiling” in the value. Local value: mount + size; if the backing device is Linux md, write `md127 RAID` (or whatever `mdN`), not a bare `md127`. Shared: guest-visible type + path + size; add the vendor product name when it is not the same as `df -T`. **Capacity only — never how much is used or free.**

### Software
Python version, torch, NCCL (`torch.cuda.nccl.version()`). Note that torch was the newest release for the driver's CUDA at eval time, and name the newer release if one exists for a newer CUDA only. **No eval venv path.** Isolated venv is how you run, not a report field.


## Compute

### Introduction
Name × count, SM count, HBM GiB, TDP, official BF16 TFLOPS. Not a benchmark dump. Then a **numbered list of the passes that follow**, each saying what the tool literally does:

1. `dcgmi diag -r 2` — NVIDIA's own health check (software, memory, PCIe).
2. `mamf-finder-all-gpus.py` — times many **matmul shapes** (M×N×K) on GPU0 to find the fastest, then measures the sustainable winner on every other GPU, each while all the others run a matmul; reports **MAMF** and **MSMF**, both vs the official spec.
3. Lemon GEMM — a throwaway inline script: one fixed matmul shape (M=N=K=16384) on every GPU, to catch a dead, slow, or throttled card.
4. `gpu-straggler-finder.py` — runs a Llama-3.1-8B training step (its 32 decoder layers, forward and backward, on one 8192-token sequence), a matmul and 2 memory-bound workloads on every GPU of every node at once, and compares each GPU with its node's median GPU in the same 2-second windows, and each node with the median node, to find a GPU that works but runs slower than its peers.

### Hardware health
**Pass** (or **Fail** on named plugins/GPUs; or Gaps: no hostengine / unprivileged). Never **Pass** and **No Fail** together.

### GPU performance benchmarks
Official TFLOPS source = [TFLOPS comparison table](https://github.com/stas00/ml-engineering/blob/master/compute/accelerator/README.md#tflops-comparison-table), not a relative path. Open that section by explaining the measurement before any number: compute is measured by timing matrix multiplication; how fast a `matmul` runs depends on its **matmul shape** (the M×N×K dimensions), so the tool searches. State how many matmul shapes GPU0's search timed (the `Tried N shapes` line in `mamf/gpu0.txt`), and that every other GPU then measured GPU0's two winning shapes while all the rest of the node ran a continuous matmul. Then `Two numbers vs official BF16 <N> TFLOPS on <GPU>:` (name the GPU; do not leave the spec floating), then two bullets, each with the measured W/MHz the script printed:

- **MAMF** (Maximum Achievable Matmul FLOPS) — highest TFLOPS a short burst at boost reaches, with the board far under its power limit, measured on every GPU at GPU0's MAMF shape; the node figure is the median GPU. A ceiling, not a rate any sustained workload holds. One number, with its shape and % spec.
- **MSMF** (Maximum Sustainable Matmul FLOPS) — best that survives once the matmul shape is large enough to pin the board at the power limit and the clock settles, measured on every GPU while all the others compute. The node figure is the median GPU, so one weak or strong chip doesn't set it; synchronous work runs at the slowest GPU, which the summary also gives. Compare a sustained workload to the median, and a synchronous job's ceiling to the slowest.

Then one table over all the nodes, from the `mamf/summary.txt` of each, and a row for each GPU more than 5% below its node's median MSMF, the candidate bar (none: say so in the sentence after the table):

| | median | lowest | highest |
| --- | ---: | ---: | ---: |
| node MAMF (TFLOPS) | … | … (`<host>(node<I>)`) | … (`<host>(node<I>)`) |
| node MSMF (TFLOPS) | … | … | … |
| GPU MSMF vs its node's median | | -…% (`<host>(node<I>):gpu<N>`) | +…% (…) |

TFLOPS are integers, as the script prints them; compute % spec from the integer. The per-GPU tables stay in `raw/mamf-*/summary.txt`. On a 1-GPU box there is no "while the others compute" and no median or spread; say it is the only GPU.

**Expand every acronym at first use in the report** — MAMF, MSMF, DCGM, NVLS, GEMM, busbw/algbw, MFU. The Terms table in this skill is for the agent; the reader of the report only sees the report.

**The eval does not know what the cluster is for.** Never assume training — the same allocation may be bought for inference, fine-tuning, or batch jobs. Write "sustained workload", not "training step"; say "training or inference" when you need an example.

Give the winning shapes and the power and clock they ran at in the bullets, as ranges over the nodes.

### Find underperforming GPUs
**TLDR:** `no under-performing or dead GPUs` — name both outcomes, since a dead card and a slow one are different findings. If something is wrong, say which: `under-performing: <host>(node<I>):gpu<N>`, `dead: <host>(node<I>):gpu<N>` or `slow node: <host>(node<I>)`. Then define an under-performing GPU (works correctly but runs slower than its peers, which every GPU of a synchronous job then waits for; dead is the extreme case), and say in one sentence why the GPU performance pass can't settle it: MAMF and MSMF report a GPU's best stretch. Do **not** prefix the heading with node count — ranks belong in the TOC annotation, not the heading. Then two `####` subsections, in the order they ran:

- `#### Lemon GEMM` — the **same** matmul shape (M=N=K=16384) on every GPU, siblings idle, flag a card well below its node's median — explicitly **not** MAMF (no search over matmul shapes, no boost/sustain split). Then 16384³ SM coverage, then the one sentence of **Lemon GEMM** above (median, range, lowest GPU), and rows only for GPUs that tripped the gate.
- `#### Stragglers` — what `gpu-straggler-finder.py` literally ran before any number: the 4 workloads with their sizes and durations, all GPUs at once, the 2-second windows, each GPU against its node's median GPU in the same window and each node's median GPU against the median node's, and the flagging rule in words — define the **modified z-score** where it is first used (how far a GPU is from the median of all the GPUs, in units of their median absolute deviation, scaled so that 3.5 is a usual cut-off for an outlier) and the **90th percentile window** (the window that only a tenth of a GPU's windows are slower than). Then the nodes in one sentence unless one was flagged: the highest any node's median GPU reached against the median node's, and in which workload, against the 3% bar. Then a table of the **flagged GPUs only**, as the script printed their rows (`<host>(node<I>)`, GPU index, the 4 workloads' median / 90th percentile window against the node's median GPU, step and matmul clock, power, temperature, flag), and one last row, **slowest of the other N**, with the highest median / 90th percentile window any unflagged GPU reached in each workload and which GPU it was: that row is the healthy spread the flagged ones stand out from. Never every GPU's row; they stay in `raw/straggler.console`. Then the run count and the verdict per flagged GPU: the workload, its numbers in each run, the runs it was flagged in, its UUID and serial. A GPU flagged in some runs and not in all gets that one sentence here and nothing in Findings.

## Network

### Introduction
Open with a **numbered list of tools** (same shape as Compute and Storage), each explained before any number: GitHub-link [`torch-distributed-gpu-test.py`](https://github.com/stas00/ml-engineering/blob/master/debug/torch-distributed-gpu-test.py) (connectivity — one process per GPU; ranks see each other and complete a collective; say how many ranks and over how many nodes it ran, and do not call a 1-node run inter-node) and [`torch-dist-bench.py`](https://github.com/stas00/ml-engineering/blob/master/network/benchmarks/torch-dist-bench.py) — say what it sweeps (all nine collectives, payloads from 8 B to 16 GiB) and define `busbw` (bus bandwidth, what the fabric moves), `algbw` (algorithm bandwidth, what the caller sees) and the latency median and p99 (the time of one call, the slowest rank's, over up to 1000 calls) **there**, plus which rank counts it ran at. Do not write “the book” or “MLE”. Then NVLS (see Terms): in-network **all-reduce** on the NVSwitch (~30% intra / ~25% inter vs ring `busbw`); does **not** help other collectives. InfiniBand switch SHARP is a different feature. Record `NCCL_NVLS_ENABLE`: **2** = auto — the eval default if unset; **0** = force off; **1** = require NVLS (can abort if unavailable). State whether NVLS was available for intra and for inter (`NCCL_DEBUG` when you have it). Name who set the env (container image / cluster), not that you “kept” it.

### All-reduce benchmark
One sentence per scope, then its plot. Intra-node: transport (e.g. NVLink 5, NV18), spec uni GBps, peak busbw and its payload, % spec (note NVLS if on). Inter-node **only if ≥2 nodes**: NIC inventory GBps, NCCL path (not % of NIC spec), peak busbw vs 1 node's at the same payload. No busbw table when the curve is normal: the plot shows it, and the console in `raw/` has every payload. A table only for the payloads that fell short or behaved oddly (a dip, a mid-size payload slower than a smaller one). Do not name the launcher. Rank/node counts go in the TOC annotation.
**Inline** `![Intra-node all-reduce](raw/<cluster>/busbw-mean-all_reduce-…-8.png)` and, with ≥2 nodes, `![Inter-node all-reduce](raw/<cluster>/busbw-mean-all_reduce-…-R.png)`.
### Latency benchmark
Why all-reduce alone would flatter, and what `batch_isend_irecv`, `all_to_all`, `all_reduce` and `all_gather`/`reduce_scatter` each show (see **Latency**), in as few sentences as that takes, then one table of all nine collectives at the smallest payload: the intra-node median, and with ≥2 nodes the inter-node median and `inter/intra ×`. p99 only in a sentence, for a collective whose p99 is more than 1.5× its median. The PyTorch caveat for `batch_isend_irecv` and `scatter` in one clause. No verdict here or in Findings beyond **Needs operator input**.
**Inline** `![Intra-node latency](raw/<cluster>/latency-collectives-…-8.png)` and, with ≥2 nodes, `![Inter-node latency](raw/<cluster>/latency-collectives-…-R.png)`.
### Gaps
(only if needed, e.g. rdzv failed on ≥2 nodes — not “only 1 node”)

## Storage

### Existing Partitions
Inventory table: **always a `/` row**, then one row per **distinct** volume. Same backing store mounted twice (`/tmp` on `/`, bind-mount aliases) is still one row. No benchmarking comments. Do not name a network FS this allocation does not use. Shared facts go after the table.

| mount | size | type | device / server |
| --- | ---: | --- | --- |
| `/` | 28T | xfs | md127 RAID0 (8× ~3.5T NVMe) |
| `/code` | 2.3T | Lustre | `10.0.0.100@tcp:/fsname` |

### Introduction
Same shape as Compute / Network: **numbered list of passes** (tool + path), not a mount inventory. GitHub-link `fio-scan` on the first item and explain what it literally does **there** — six `fio` runs against one directory — file sizes **16 KiB, 1 MiB and 1 GiB (correspondingly small, medium and large)**, each read and write — 16 parallel jobs, 4 KiB blocks, `libaio`, `O_DIRECT` (and say what `O_DIRECT` buys: bypasses the page cache so the numbers are the filesystem's, not RAM's), 3 min of timed IO each.

**Write IEC units, never `fio`'s shorthand.** The script prints `16k` / `1m` / `1g`; the report says **16 KiB** / **1 MiB** / **1 GiB**, in the `size` column of both tables and in every sentence that cites a row. `16k` is not a valid unit. Later mentions are bare. Then the table units note. All “we scanned X” comments live here.

Two tables, **same columns and same IOPS scale**:

| size | rw | latency (msec) | bw (MiBps) | IOPS (M) |
| ---: | --- | ---: | ---: | ---: |
| 16 KiB | read | … | 12_029.1 | 3.08 |
| … | … | … | 631.8 | 0.157 |

### Local disk IO benchmark
…
### Shared <product> IO benchmark
| size | rw | latency (msec) | bw (MiBps) | IOPS (M) | local/shared × |

Heading is **Shared <product> IO benchmark** (e.g. Shared Lustre IO benchmark), not a bare “Shared”. Several shares of one product go under that one heading, a table per share (or per group the 5% rule allows), each opened by a line naming it and its size (`` `/data`, 14T: ``); not a heading per share, whose duplicate names would break the anchors. Optional extra when ≥2 nodes: **Concurrent write shared fs benchmark**, one table for every share: `| share | node0 alone (MiBps) | 4 nodes at once, slowest – fastest node (MiBps) | 4 nodes together (MiBps) |`. Omit on 1 node.

Local NVMe vs shared network FS (16 KiB / 1 MiB / 1 GiB, read+write). bw = MiBps (`_` on the fast table). IOPS = 10⁶ in every table. **`size` is right-aligned** (`---:`), like every other numeric column; only `rw` is left-aligned. Each shared table appends **`local/shared ×`** at the **end** (local bandwidth ÷ shared bandwidth) so the first five columns match local. Explain the column in a **sentence**, not a chain of equations: what it divides and what 1 would mean. Do not add an IOPS ratio: fixed 4 KiB blocks make it identical to the bandwidth ratio. **Quote table values verbatim** in prose — if the column says `26.5`, write `26.5×`, never `27×`. Do not express the comparison as a percentage, do not call it `%local`, and say "the local disk table above", not a device name. Raw unscaled numbers in `raw/`.
(omit Gaps unless something is missing)

## Findings

Up to three headings, in this order — **### Healthy subsystems**, **### Underperforming subsystems**, **### Needs operator input** (the noun is required; never a bare `### Healthy`). Include only the ones that have bullets. Bullet labels are the subsystem (GPUs, fabric, local disk, shared network FS, torchrun) — **never prefix with A./B./C.** (the report sections are Compute, Network, Storage). Split mixed areas (e.g. local disk vs shared FS). Do not put an underperforming item in Healthy with a caveat, and do not hide it in a Flags list that looks like the healthy bullets.

Healthy subsystems: fabric and GPUs that met spec. Network headline is **fabric** (intra vs NVLink spec + NVLS; inter busbw + path + vs 1-node all-reduce) — **never** “X% of NIC/rail,” and **not** a launcher. Do not credit DeepSpeed / torchrun / srun in busbw or Findings.

**Under-performing and dead GPUs** get one bullet each under Underperforming subsystems, from any of the 3 passes (the lemon gate, the GPU performance pass, the finder). Name each as `<host>(node<I>):gpu<N>`, e.g. `blah-176(node0):gpu7`: `<host>` is the hostname the Environment Host table uses, which an operator needs to drain or replace the card; `node<I>` is the node's 0-based position in the hostfile (the order the user gave the nodes, from `raw/hostfile-map.txt`; `node0` on a 1-node eval, which has no hostfile), which stays readable when hostnames are cryptic; `<N>` is the GPU index `nvidia-smi` shows. Follow it with the pass that found it and its numbers against its node's median, e.g. "`blah-176(node0):gpu7` — MSMF 701 / 698 / 704 TFLOPS in three passes, 6.8–7.2% below the node median each time". Add every such GPU's UUID and serial, which `gpu-straggler-finder.py` prints on its line, and which the environment dump's `uuid` and `serial` columns give for a GPU another pass found: the serial is what an operator replaces the card by, and the UUID stays the same when the node is renamed or re-imaged, while the hostname and index may not — e.g. "`blah-176(node0):gpu7` — training step 3.4% / 4.1% / 3.2% / 3.8% slower than its node's median GPU in 4 runs, UUID `GPU-…`, serial `…`". A slow node gets its own bullet, `<host>(node<I>)`, with its median GPU against the median node's in each run and its GPUs' serials, which the finder prints. List every one; never summarize as "two slow GPUs".

Underperforming subsystems: measured vs **vendor advertised** for **this** product; not good enough for code (16 KiB) / checkpoint (1 GiB → 1 TiB) / dataloader; torchrun/rdzv if it failed; leftover Gaps. A broken launcher is **not** “the network is unhealthy.” Do not name a network FS this allocation does not use.

**Needs operator input: a verdict requires a target, so a measurement without one goes here, not under Underperforming.** Calling a subsystem slow when you have nothing to compare it against is an opinion dressed as a finding — the reader cannot act on it and the operator can dismiss it. This heading is for a subsystem that was measured cleanly but whose expected figures only the operator has: a shared FS with no published provisioned throughput, a fabric whose purchased tier is unknown, any device whose spec sheet does not exist publicly. Open with one sentence saying these cannot be called healthy or underperforming until those figures arrive.

**Every bullet ends with what the operator tells the agent, and what the agent then does with it.** A list of what the eval couldn't settle, with hints, leaves the operator nothing to do; the bullet is an instruction. Each one has 3 parts:

1. The subsystem and its measurement in one line, or a link to the section's table when it has more numbers than fit on one.
2. **Tell the agent:** a reply the operator can fill in and paste, in the units and under the conditions measured, with the blanks marked — e.g. `/code expected, one client, 16 jobs, 4 KiB blocks, O_DIRECT, MiB/s read / write: 16 KiB _ / _, 1 MiB _ / _, 1 GiB _ / _; per client or per filesystem: _`. Offer the alternatives the agent can work from, cheapest first: a product and tier the agent can turn into figures (`FSx for Lustre, 250 MB/s per TiB`), the figures themselves, or a path to a reference run of the same tool on a known-good cluster of the same type.
3. **The agent then:** what it does with the answer — compares each measured cell with its expected one, calls those within 10% healthy and the rest underperforming, and moves the bullet to **Healthy subsystems** or **Underperforming subsystems** with the comparison; or reruns what the answer unblocks (`lfs getstripe` once `lfs` may be installed).

Don't put here what the agent can do itself: install a missing tool if it has `sudo`, look up a product's published tier figures, rerun a pass. Do it, or put it in **Gaps** with the command it needs permission to run.

**Write targets in the plural — a filesystem never has one.** Every file size and operation has its own rate, reads and writes differ, so it is "the figures they are supposed to hit" and "no published performance figures", never the singular. The singular quietly promises the reader one number to compare against, which is the mistake the whole category exists to avoid.

**Ask only about the mount you measured, and name its size.** Expected rates are per filesystem, so asking for "`/code` and `/data`" when six numbers came from `/code` alone invites an answer you cannot use. State which mount the figures describe, and if sibling mounts differ in size, say that each has its own target and needs its own scan — pointing at the one the workload will lean on hardest.

**Ask for the targets in the same shape as your measurement, or they will not settle anything.** "The provisioned throughput" is not askable — a parallel FS has no single rate, and a per-TiB headline number cannot be checked against a row of the table. Ask for **one expected value per measured cell, in the units you measured, under the conditions you measured**: for `fio-scan` that is bandwidth in MiB/s **or** IOPS at 16 KiB, 1 MiB and 1 GiB, read and write, from one client with 16 jobs, 4 KiB blocks and `O_DIRECT`. Either unit is enough because the fixed block size makes one derivable from the other. Say those conditions in the ask, because the same filesystem answers differently per client and in aggregate, and because small-file and large-file rates come from different limits — one headline figure hides both. Then add the conditions that would invalidate a comparison if the operator's figures assume something else: per-client vs per-filesystem, and stripe count. A comparison against another subsystem you did measure (shared FS vs local disk, `26.5×` slower) is a fact and belongs in the bullet; it is not a substitute for the target, because local NVMe was never what the shared FS was sold to match.

Judge before you place a bullet: is there a number this is supposed to hit? Official TFLOPS, NVLink spec GBps and a vendor-advertised FS figure are targets, so those bullets can be Healthy or Underperforming. If the answer is "the operator would have to tell me", the bullet goes in **Needs operator input** even when the measurement looks disappointing.

**Quote the whole measurement, compactly, not one cherry-picked row — or link the table.** A storage bullet has six numbers behind it, so give all six in one line — `read / write: 16 KiB **a MiB/s / b MiB/s**, 1 MiB **c MiB/s / d MiB/s**, 1 GiB **e MiB/s / f MiB/s**` — instead of a single size, which leaves the reader asking what the others were. Same for any bench that swept a parameter. Compact, not partial.

**Every number outside a table carries its unit.** Putting `MiB/s` once in the lead-in and then listing bare `1_646.1 / 1_658.3` is a table habit; in prose each value needs its abbreviation — `1_646.1 MiB/s / 1_658.3 MiB/s`. `read / write` once is fine. Same for GBps, TFLOPS, msec, ×. The table header is the one place a unit may appear only once.

**When vendor figures are missing, say the targets are unknown, say why none are published, and ask for them — but do not narrate the search.** Three things, because a measurement with no target cannot be called a shortfall, and a reader who knows the filesystem's name will reasonably assume a spec sheet exists: (1) state plainly that the provisioned figures are unknown and the measured numbers therefore have nothing to be judged against; (2) explain in a sentence why — for a parallel FS, **the software publishes no performance figures**; Lustre, GPFS/Storage Scale, BeeGFS and NFS are filesystem software, and throughput is a property of the deployment (count of object storage targets / servers, their backing devices, the network to them, per-file stripe count), so the number that exists is the **service tier the operator purchased**, typically sold per TiB of capacity (managed Lustre commonly 125–1000 MB/s per TiB); (3) ask the user for that tier **and** the default stripe layout, since a single-stripe file is served by one storage target regardless of filesystem size and is the usual explanation for a single client seeing a few hundred MiB/s. What to leave out is the search: where you looked, what `df` or the mount table did not contain. A mount was never going to state IO speed, so ruling it out tells the reader nothing and reads as an excuse.

**Say who is slowed and by how much, in literal terms.** Hardware and files do not "feel", "suffer", "struggle", "get punished", or "care"; a filesystem is not "painful". Name the concrete operation and attach the measured rate to it — "a `git clone` or `pip install` on `/code` runs at the 16 KiB read rate of 204.7 MiB/s" — so the reader can check the claim against the table instead of trusting an adjective.

If nothing underperformed, **omit that heading and its TOC line** — never write `Underperforming subsystems: none`. Same for **Needs operator input** when every target was known. No extra **Flags** section.

Final pass before you show the report

Prose rules get skipped. Run this list against the finished report, line by line, before you tell the user it is ready. Each item has failed a real review.

| check | fix |

| -------------------------------------------------------------------------------------------------------------- | ---------------------------------------------------------------------------------------------------------------------------------------------------- |

| Every acronym expanded at first use (MAMF, MSMF, DCGM, NVLS, GEMM, busbw, algbw) | Maximum Achievable Matmul FLOPS, … |

| Every tool says what it literally does before its first number | how many shapes / payloads / runs, and what it varied |

| No term used before it is defined ("any shape", local/shared ×, CTA, O_DIRECT) | define at first use, in a sentence — not as an equation |

| Shared-vs-local stated as times slower, not percent | 8.0×, not 12.4% |

| Prose numbers identical to the table cell they cite | table 26.5 → prose 26.5×, never 27× |

| Findings bullets carry the full sweep, compactly | all three sizes × read/write on one line, not just 1 GiB |

| Every number outside a table has its unit | 1_646.1 MiB/s / 1_658.3 MiB/s, not a lead-in MiB/s: then bare numbers |

| Nothing inanimate given feelings | not "small files will feel that" — name the operation and its measured rate |

| Targets in the plural | "the figures they are supposed to hit", never "the figure" |

| Missing vendor figures: target-unknown admission + why none are published + the ask, no search narrative | keep "provisioned throughput is unknown, so there is no target to compare against"; drop "the mounts show only the server address and size" |

| Latency reported for every collective, never as % of spec or a verdict | all nine at the smallest payload; inter/intra × when ≥2 nodes; Findings → Needs operator input only |

| Every Needs operator input bullet is an instruction | ends with Tell the agent: (a fill-in reply, in the measured units) and The agent then: (what it compares or reruns, and where the bullet moves) |

| No row for a normal GPU, node or payload | median and range in a sentence; rows for outliers only, plus a "slowest of the others" row; the rest in raw/ |

| No bullet judged without a target | no known figure to hit → ### Needs operator input, not Underperforming |

| Shared-FS figures scoped to the mount they came from, with its size | one mount's table is never "the shared FS"; differently-sized siblings each need their own scan |

| Distinct shared mounts grouped only by the 5% rule | one table only if every corresponding bandwidth and IOPS cell is within 5%; otherwise separate tables |

| The ask names one expected value per measured cell, with conditions | "expected MiB/s or IOPS at 16 KiB / 1 MiB / 1 GiB, read and write, one client, 16 jobs, 4 KiB blocks, O_DIRECT" — not "the provisioned throughput" |

| Sizes in IEC units | 16 KiB / 1 MiB / 1 GiB, never 16k / 1m / 1g |

| Storage table headers carry units in () | size, rw, latency (msec), bw (MiBps), IOPS (M) |

| Numeric columns right-aligned, including size | ---: for all but rw |

| Every ### heading matches its TOC label, and every anchor resolves | rebuild anchors from the headings you wrote |

| Labels match what actually ran | a 1-node connectivity run is intra-node |

| Every slow or dead GPU named as <host>(node<I>):gpu<N> in Findings, and a slow one confirmed in three passes | blah-176(node0):gpu7, not "GPU7" or "one slow card" |

| A straggler in Findings only if gpu-straggler-finder.py flagged it in all 4 runs, with its UUID and serial | flagged in some runs → one sentence in #### Stragglers, not a Findings bullet |

| No absence asserted | no Skip reasons: none, ### Gaps / None, N/A |

| No redundant verdicts | Pass, not Pass … No Fail |

| No filler sentences | "collects the results into one table", "as expected" |

| No workload assumed | "sustained workload", not "training step" |

| Scratch cleared from every mount you wrote to | du -sh each scan dir; fio-test/ moved to that mount's trash/, paths and sizes named in your summary |

Then fold any correction the user still makes back into this file (see Keep this skill up to date).

Training wheels

These are examples of past jobs, not defaults and not required knowledge. Discover the next cluster from scratch (how to exec, namespace, launcher, NCCL env, mounts). Skip this section if none of it matches.

Lessons:

Use this skill with your AI agent: Open on Skill Issue to copy, download, or add to your library. Works with Claude, ChatGPT, Gemini, Cursor, Windsurf and more.