Error Handling
When to Use
Use this skill when the user asks about error handling, checking errors, debugging ovrtx failures, or troubleshooting.
Inputs
Resolve inputs in this order: existing repository files and referenced snippets, explicit user request, then broader agent context.
- Target API surface: Python, C/C++, or both.
- Language and failure point: Python sync call, Python async wait/fetch, C enqueue, C wait, C fetch, or C map/unmap.
- Error signal available to the caller: exception text,
ovrtx_status_t, operation index, result handle, orovrtx_get_last_error(). - Operation being debugged and whether the caller needs recovery, logging, or propagation guidance.
- Repository source snippets referenced below. Treat these snippets as the API source of truth.
Prerequisites
- Use an ovrtx checkout that contains the referenced examples and docs tests.
- Read the relevant
> **Source:**snippet before writing or explaining API usage. - Determine where errors surface for the operation before adding checks; enqueue success does not guarantee async completion success.
Instructions
- Identify whether the failure path is Python synchronous, Python async, C enqueue, C wait, C fetch, or C map/unmap.
- In Python, catch
RuntimeErroraround the API call or aroundwait()for async operations, depending on where the operation surfaces errors. - In C, check every returned
ovrtx_result_t.statusor enqueue status before using output values. - After C wait calls, inspect operation errors before fetching results, and call
ovrtx_get_last_error()immediately when a status indicates failure. - When changing code, run the narrow example or docs test that exercises the failing operation whenever practical.
Output Format
- For explanations, cite the relevant API names, source snippets, and caveats.
- For code changes, summarize the files changed, snippets affected, and validation run.
Scripts
This skill has no scripts.
Limitations
- The referenced snippets remain the source of truth; update or add tested snippets before documenting new API usage.
Overview
In Python, ovrtx raises RuntimeError with descriptive messages on failure. In C, every API call returns a status code that must be checked, and error details are retrieved with ovrtx_get_last_error().
Python
Automatic error handling
All Python API methods raise RuntimeError on failure. The minimal step
example shows the synchronous call shape to wrap in user code:
Source:
tests/docs/python/test_error_handling.pysnippetdoc-python-sync-runtime-error
The test demonstrates the synchronous Python error surface pattern.
Async operation errors
Errors from async operations surface when you call wait():
Source:
tests/docs/python/test_error_handling.pysnippetdoc-python-async-operation-error
Step errors
Source:
examples/python/minimal/main.pysnippetstep
Wrap in
try/except RuntimeErrorto handle step failures.
C
Check every return value
Source:
examples/c/minimal/main.cppsnippetcreate-renderer
Source (continued):
examples/c/minimal/main.cppsnippetload-usd-and-wait
Every API call returns a status code. Check with the
check-error-helpersnippet pattern.
check_and_print_error helper function
From the minimal C example -- a template helper that checks the status, prints to std::cerr, and returns whether an error occurred. Works with both ovrtx_result_t and ovrtx_enqueue_result_t:
Source:
examples/c/minimal/main.cppsnippetcheck-error-helper
Per-operation errors from wait
Asynchronous errors (e.g., file not found during USD load) are reported through ovrtx_wait_op:
Source:
examples/c/minimal/main.cppsnippetload-usd-and-wait
Check
wait_result.num_error_opsand iteratewait_result.error_op_idsafterovrtx_wait_op.
Log callback (C)
Set a process-global callback to receive log messages, with severity filtering and per-channel rules:
Source:
tests/docs/c/test_logging.cppsnippetdoc-log-callback-prefix-filter-c
Log severity levels follow carb's numeric ordering: OVX_LOG_VERBOSE (-2), OVX_LOG_INFO (-1), OVX_LOG_WARNING (0), OVX_LOG_ERROR (1), OVX_LOG_FATAL (2). The callback is process-global: its lifetime is ovrtx_initialize to ovrtx_shutdown, so it observes messages emitted before the first renderer is created and after the last one is destroyed (e.g. plugin-load and asset-eviction messages). The callback may be invoked from any thread. Message strings are only valid during the callback. Note that if multiple OV libraries are used in an app, multiple logging callbacks may be registered, one from each OV library. In this case, it is the host app's responsibility to ensure that the callback's access to the host app's logging system is thread-safe.
channel_filter syntax
channel_filter is a comma-separated list of <channel_prefix>=<level> entries (RUST_LOG-style). The channel prefix is matched against carb's dotted source name; longest matching prefix wins. Channels not matched by any explicit rule fall back to the severity parameter. Accepted level names (case-insensitive): verbose (alias debug), info, warn (alias warning), error, fatal. Whitespace around tokens and trailing commas are tolerated; malformed entries (missing =, unknown level, empty channel) cause ovrtx_set_log_callback to return OVRTX_API_ERROR with a descriptive ovrtx_get_last_error() string and leave the previously installed callback state unchanged.
Examples:
""(orNULL): every channel usesseverityas its threshold."omni.usd=error":omni.usd*is admitted at error+, every other channel usesseverity."carb=warn,carb.tasking=verbose":carb.taskingis admitted at verbose+, othercarb.*channels at warn+, everything else usesseverity.
Key Types / Functions
| Python | C |
|--------|---|
| RuntimeError | result.status == OVRTX_API_ERROR |
| exception message | ovrtx_get_last_error() |
| async error on wait() | ovrtx_get_last_op_error(op_id) |
| (not exposed) | ovrtx_set_log_callback(severity, channel_filter, callback, user_data) |
| (not exposed) | ovrtx_flush_log(timeout) |
C status codes:
OVRTX_API_SUCCESS(0) -- successOVRTX_API_ERROR(1) -- error, callovrtx_get_last_error()for detailsOVRTX_API_TIMEOUT(2) -- timeout reached
Troubleshooting
- On Linux systems with no display, repeatedly creating and destroying renderers may result in a native crash with the stack trace pointing into
libEGL.sowhen shared graphics resources are torn down between renderers. This can happen ifkeep_system_aliveis configured tofalse, or ifovrtx_initialize()is not called before the multi-renderer lifecycle. In the implicit-initialization pattern (whenovrtx_initialize()is not called), thekeep_system_aliveconfig setting is effectively ignored. Avoid this by both configuringkeep_system_alivetotrue(RendererConfig(keep_system_alive=True)in Python,ovrtx_config_entry_keep_system_alive(true)in C) and callingovrtx_initialize()before creating renderers. If this is not possible, or the crash persists, a further workaround is to set the environment variableVK_LOADER_DISABLE_DYNAMIC_LIBRARY_UNLOADING=1. - Error strings from
ovrtx_get_last_error()live in thread-local storage and are invalidated by the next API call on the same thread. Copy the string if you need to keep it. ovrtx_get_last_op_error()strings are valid only until the nextovrtx_wait_opcall.- In C error paths, clean up explicitly: destroy step results if alive, destroy renderer if created, and call
ovrtx_shutdown()ifovrtx_initialize()was called. - In C, some enqueue operations (like
ovrtx_open_usd_from_file) may succeed at enqueue time but fail during async execution. Always checkwait_result.error_op_idsafter waiting. - In Python, some errors during
__del__cleanup are printed to stderr rather than raised (since Python does not allow exceptions in destructors).
References
- Use the
> **Source:**directives in this skill to locate tested snippets before reusing API patterns. - Keep related skills, docs, and snippets synchronized when changing the workflow.