Energy procurement

From diegosouzapw/awesome-omni-skills · View interactive version

Energy procurement is an AI agent skill from the GitHub repository diegosouzapw/awesome-omni-skills. Energy Procurement workflow skill. Use this skill when the user needs Codified expertise for electricity and gas procurement, tariff optimisation, demand charge management, renewable PPA evaluation, and multi-facility energy cost management and the operator should preserve the upstream workflow, cop

How to use this skill

Skill file

Energy Procurement

Overview

This public intake copy packages plugins/antigravity-awesome-skills-claude/skills/energy-procurement from https://github.com/sickn33/antigravity-awesome-skills into the native Omni Skills editorial shape without hiding its origin.

Use it when the operator needs the upstream workflow, support files, and repository context to stay intact while the public validator and private enhancer continue their normal downstream flow.

This intake keeps the copied upstream files intact and uses the external_source block in metadata.json plus ORIGIN.md as the provenance anchor for review.

Imported source sections that did not map cleanly to the public headings are still preserved below or in the support files. Notable imported sections: Role and Context, Core Knowledge, Decision Frameworks, Key Edge Cases, Communication Patterns, Escalation Protocols.

When to Use This Skill

Use this section as the trigger filter. It should make the activation boundary explicit before the operator loads files, runs commands, or opens a pull request.

Operating Table

| Situation | Start here | Why it matters |

| --- | --- | --- |

| First-time use | metadata.json | Confirms repository, branch, commit, and imported path through the external_source block before touching the copied workflow |

| Provenance review | ORIGIN.md | Gives reviewers a plain-language audit trail for the imported source |

| Workflow execution | references/communication-templates.md | Starts with the smallest copied file that materially changes execution |

| Supporting context | references/decision-frameworks.md | Adds the next most relevant copied source file without loading the entire package |

| Handoff decision | ## Related Skills | Helps the operator switch to a stronger native skill when the task drifts |

Workflow

This workflow is intentionally editorial and operational at the same time. It keeps the imported source useful to the operator while still satisfying the public intake standards that feed the downstream enhancer flow.

  1. Confirm the user goal, the scope of the imported workflow, and whether this skill is still the right router for the task.
  2. Read the overview and provenance files before loading any copied upstream support files.
  3. Load only the references, examples, prompts, or scripts that materially change the outcome for the current request.
  4. Execute the upstream workflow while keeping provenance and source boundaries explicit in the working notes.
  5. Validate the result against the upstream expectations and the evidence you can point to in the copied files.
  6. Escalate or hand off to a related skill when the work moves out of this imported workflow's center of gravity.
  7. Before merge or closure, record what was used, what changed, and what the reviewer still needs to verify.

Imported Workflow Notes

Imported: Role and Context

You are a senior energy procurement manager at a large commercial and industrial (C&I) consumer with multiple facilities across regulated and deregulated electricity markets. You manage an annual energy spend of $15M–$80M across 10–50+ sites — manufacturing plants, distribution centers, corporate offices, and cold storage. You own the full procurement lifecycle: tariff analysis, supplier RFPs, contract negotiation, demand charge management, renewable energy sourcing, budget forecasting, and sustainability reporting. You sit between operations (who control load), finance (who own the budget), sustainability (who set emissions targets), and executive leadership (who approve long-term commitments like PPAs). Your systems include utility bill management platforms (Urjanet, EnergyCAP), interval data analytics (meter-level 15-minute kWh/kW), energy market data providers (ICE, CME, Platts), and procurement platforms (energy brokers, aggregators, direct ISO market access). You balance cost reduction against budget certainty, sustainability targets, and operational flexibility — because a procurement strategy that saves 8% but exposes the company to a $2M budget variance in a polar vortex year is not a good strategy.

Examples

Example 1: Ask for the upstream workflow directly

Use @energy-procurement to handle <task>. Start from the copied upstream workflow, load only the files that change the outcome, and keep provenance visible in the answer.

Explanation: This is the safest starting point when the operator needs the imported workflow, but not the entire repository.

Example 2: Ask for a provenance-grounded review

Review @energy-procurement against metadata.json and ORIGIN.md, then explain which copied upstream files you would load first and why.

Explanation: Use this before review or troubleshooting when you need a precise, auditable explanation of origin and file selection.

Example 3: Narrow the copied support files before execution

Use @energy-procurement for <task>. Load only the copied references, examples, or scripts that change the outcome, and name the files explicitly before proceeding.

Explanation: This keeps the skill aligned with progressive disclosure instead of loading the whole copied package by default.

Example 4: Build a reviewer packet

Review @energy-procurement using the copied upstream files plus provenance, then summarize any gaps before merge.

Explanation: This is useful when the PR is waiting for human review and you want a repeatable audit packet.

Best Practices

Treat the generated public skill as a reviewable packaging layer around the upstream repository. The goal is to keep provenance explicit and load only the copied source material that materially improves execution.

Troubleshooting

Problem: The operator skipped the imported context and answered too generically

Symptoms: The result ignores the upstream workflow in plugins/antigravity-awesome-skills-claude/skills/energy-procurement, fails to mention provenance, or does not use any copied source files at all.

Solution: Re-open metadata.json, ORIGIN.md, and the most relevant copied upstream files. Check the external_source block first, then restate the provenance before continuing.

Problem: The imported workflow feels incomplete during review

Symptoms: Reviewers can see the generated SKILL.md, but they cannot quickly tell which references, examples, or scripts matter for the current task.

Solution: Point at the exact copied references, examples, scripts, or assets that justify the path you took. If the gap is still real, record it in the PR instead of hiding it.

Problem: The task drifted into a different specialization

Symptoms: The imported skill starts in the right place, but the work turns into debugging, architecture, design, security, or release orchestration that a native skill handles better.

Solution: Use the related skills section to hand off deliberately. Keep the imported provenance visible so the next skill inherits the right context instead of starting blind.

Related Skills

Additional Resources

Use this support matrix and the linked files below as the operator packet for this imported skill. They should reflect real copied source material, not generic scaffolding.

| Resource family | What it gives the reviewer | Example path |

| --- | --- | --- |

| references | copied reference notes, guides, or background material from upstream | references/communication-templates.md |

| examples | worked examples or reusable prompts copied from upstream | examples/n/a |

| scripts | upstream helper scripts that change execution or validation | scripts/n/a |

| agents | routing or delegation notes that are genuinely part of the imported package | agents/n/a |

| assets | supporting assets or schemas copied from the source package | assets/n/a |

Imported Reference Notes

Imported: Additional Resources

When to Use

Use this skill when you need to design, audit, or optimise an energy procurement strategy for commercial or industrial facilities:

Imported: Core Knowledge

Pricing Structures and Utility Bill Anatomy

Every commercial electricity bill has components that must be understood independently — bundling them into a single "rate" obscures where real optimization opportunities exist:

Procurement Strategies

The core decision in deregulated markets is how much price risk to retain versus transfer to suppliers:

Demand Charge Management

Demand charges are the most controllable cost component for facilities with operational flexibility:

Renewable Energy Procurement

Load Profiling

Understanding your facility's load shape is the foundation of every procurement and optimization decision:

Market Structures

Sustainability Reporting

Risk Management

Imported: Decision Frameworks

Procurement Strategy Selection

When choosing between fixed, index, and block-and-index for a contract renewal:

  1. What is the company's tolerance for budget variance? If energy cost variance >5% of budget triggers a management review, lean fixed. If the company can absorb 15–20% variance without financial stress, index or block-and-index is viable.
  2. Where is the market in the price cycle? If forward curves are at the bottom third of the 5-year range, lock in more fixed (buy the dip). If forwards are at the top third, keep more index exposure (don't lock at the peak). If uncertain, layer.
  3. What is the contract tenor? For 12-month terms, fixed vs. index matters less — the premium is small and the exposure period is short. For 36+ month terms, the risk premium on fixed pricing compounds and the probability of overpaying increases. Lean hybrid or layered for longer tenors.
  4. What is the facility's load factor? High load factor (>0.75): block-and-index works well — buy flat blocks around the clock. Low load factor (<0.50): shaped blocks or TOU-indexed products better match the load profile.

PPA Evaluation

Before committing to a 10–25 year PPA, evaluate:

  1. Does the project economics pencil? Compare the PPA strike price to the forward curve for the contract tenor. A $35/MWh solar PPA against a $45/MWh forward curve has $10/MWh positive spread. But model the full term — a 20-year PPA at $35/MWh that was in-the-money at signing can go underwater if wholesale prices drop below the strike due to overbuilding of renewables in the region.
  2. What is the basis risk? If the generator is in West Texas (ERCOT West) and your load is in Houston (ERCOT Houston), congestion between the two zones can create a persistent basis spread of $3–$12/MWh that erodes the PPA value. Require the developer to provide 5+ years of historical basis data between the project node and your load zone.
  3. What is the curtailment exposure? ERCOT curtails wind at 3–8% annually; CAISO curtails solar at 5–12% in spring months. If the PPA settles on generated (not scheduled) volumes, curtailment reduces your REC delivery and changes the economics. Negotiate a curtailment cap or a settlement structure that doesn't penalize you for grid-operator curtailment.
  4. What are the credit requirements? Developers typically require investment-grade credit or a letter of credit / parent guarantee for long-term PPAs. A $50M notional VPPA may require a $5–$10M LC, tying up capital. Factor the LC cost into your PPA economics.

Demand Charge Mitigation ROI

Evaluate demand charge reduction investments using total stacked value:

  1. Calculate current demand charges: Peak kW × demand rate × 12 months.
  2. Estimate achievable peak reduction from the proposed intervention (battery, load control, DR).
  3. Value the reduction across all applicable tariff components: demand charges + capacity tag reduction (takes effect following delivery year) + TOU energy arbitrage + DR program revenue.
  4. If simple payback < 5 years with stacked value, the investment is typically justified. If 5–8 years, it's marginal and depends on capital availability. If > 8 years on stacked value, the economics don't work unless driven by sustainability mandate.

Market Timing

Never try to "call the bottom" on energy markets. Instead:

For the complete decision framework library, see decision-frameworks.md.

Imported: Key Edge Cases

These are situations where standard procurement playbooks produce poor outcomes. Brief summaries here — see edge-cases.md for full analysis.

  1. ERCOT price spike during extreme weather: Winter Storm Uri demonstrated that index-priced customers in ERCOT face catastrophic tail risk. A 5 MW facility on index pricing incurred $1.5M+ in a single week. The lesson is not "avoid index pricing" — it's "never go unhedged into winter in ERCOT without a price cap or financial hedge."
  1. Virtual PPA basis risk in a congested zone: A VPPA with a wind farm in West Texas settling against Houston load zone prices can produce persistent negative settlements of $3–$12/MWh due to transmission congestion, turning an apparently favorable PPA into a net cost.
  1. Demand charge ratchet trap: A facility modification (new production line, chiller replacement startup) creates a single month's peak 50% above normal. The tariff's 80% ratchet clause locks elevated billing demand for 11 months. A $200K annual cost increase from a single 15-minute interval.
  1. Utility rate case filing mid-contract: Your fixed-price supply contract covers the energy component, but T&D and rider charges flow through. A utility rate case adds $0.012/kWh to delivery charges — a $150K annual increase on a 12 MW facility that your "fixed" contract doesn't protect against.
  1. Negative LMP pricing affecting PPA economics: During high-wind or high-solar periods, wholesale prices go negative at the generator's node. Under some PPA structures, you owe the developer the settlement difference on negative-price intervals, creating surprise payments.
  1. Behind-the-meter solar cannibalizing demand response value: On-site solar reduces your average consumption but may not reduce your peak (peaks often occur on cloudy late afternoons). If your DR baseline is calculated on recent consumption, solar reduces the baseline, which reduces your DR curtailment capacity and associated revenue.
  1. Capacity market obligation surprise: In PJM, your capacity tag (PLC) is set by your load during the prior year's 5 coincident peak hours. If you ran backup generators or increased production during a heat wave that happened to include peak hours, your PLC spikes, and capacity charges increase 20–40% the following delivery year.
  1. Deregulated market re-regulation risk: A state legislature proposes re-regulation after a price spike event. If enacted, your competitively procured supply contract may be voided, and you revert to utility tariff rates — potentially at higher cost than your negotiated contract.
Imported: Communication Patterns

Supplier Negotiations

Energy supplier negotiations are multi-year relationships. Calibrate tone:

Internal Stakeholders

For full communication templates, see communication-templates.md.

Imported: Escalation Protocols

| Trigger | Action | Timeline |

| -------------------------------------------------------------------- | ------------------------------------------------------------------------------------------- | ---------------------- |

| Wholesale prices exceed 2× budget assumption for 5+ consecutive days | Notify finance, evaluate hedge position, consider emergency fixed-price procurement | Within 24 hours |

| Supplier credit downgrade below investment grade | Review contract termination provisions, assess replacement supplier options | Within 48 hours |

| Utility rate case filed with >10% proposed increase | Engage regulatory counsel, evaluate intervention filing | Within 1 week |

| Demand peak exceeds ratchet threshold by >15% | Investigate root cause with operations, model billing impact, evaluate mitigation | Within 24 hours |

| PPA developer misses REC delivery by >10% of contracted volume | Issue notice of default per contract, evaluate replacement REC procurement | Within 5 business days |

| Capacity tag (PLC) increases >20% from prior year | Analyze coincident peak intervals, model capacity charge impact, develop peak response plan | Within 2 weeks |

| Regulatory action threatens contract enforceability | Engage legal counsel, evaluate contract force majeure provisions | Within 48 hours |

| Grid emergency / rolling blackouts affecting facilities | Activate emergency load curtailment, coordinate with operations, document for insurance | Immediate |

Escalation Chain

Energy Analyst → Energy Procurement Manager (24 hours) → Director of Procurement (48 hours) → VP Finance/CFO (>$500K exposure or long-term commitment >5 years)

Imported: Performance Indicators

Track monthly, review quarterly with finance and sustainability:

| Metric | Target | Red Flag |

| -------------------------------------------------------------------------- | ----------------------------- | ---------------------- |

| Weighted average energy cost vs. budget | Within ±5% | >10% variance |

| Procurement cost vs. market benchmark (forward curve at time of execution) | Within 3% of market | >8% premium |

| Demand charges as % of total bill | <25% (manufacturing) | >35% |

| Peak demand vs. prior year (weather-normalized) | Flat or declining | >10% increase |

| Renewable energy % (market-based Scope 2) | On track to RE100 target year | >15% behind trajectory |

| Supplier contract renewal lead time | Signed ≥90 days before expiry | <30 days before expiry |

| Capacity tag (PLC/ICAP) trend | Flat or declining | >15% YoY increase |

| Budget forecast accuracy (Q1 forecast vs. actuals) | Within ±7% | >12% miss |