Endo assess cgm understands not replace smbg

From dromlakhani/MD2SKILL · View interactive version

Endo assess cgm understands not replace smbg is an AI agent skill from the GitHub repository dromlakhani/MD2SKILL. Confirms patient understands that continuous glucose monitoring complements but does not replace self-monitoring of blood glucose. Triggers include: 'Clarify CGM role alongside fingersticks', 'Ensure patient knows CGM does not eliminate need for SMBG'.

How to use this skill

Skill file

Assess patient understanding that CGM does not replace SMBG

STEP 1 — Gather Information

Ask the patient about their beliefs regarding CGM and SMBG: whether they think CGM eliminates the need for fingerstick glucose checks, and explore prior education on CGM use, calibration requirements, and situations requiring SMBG (e.g., symptom verification, hypoglycemia unawareness).

STEP 2 — Rule In / Rule Out

Determine if the patient correctly understands that CGM does NOT replace SMBG (i.e., they acknowledge ongoing need for fingersticks for calibration, confirmation of symptoms, or when CGM readings are questionable) versus the misconception that CGM alone suffices.

STEP 3 — Classify or Stratify

Classify understanding as adequate (patient affirms need for SMBG alongside CGM) or inadequate (patient believes CGM replaces SMBG or is unsure).

STEP 4 — Decide

If understanding is adequate, reinforce and continue routine CGM support; if inadequate, provide targeted education on CGM’s complementary role, calibration with SMBG, and clinical scenarios requiring fingerstick verification.

Clinical Guardrails / Mimics / Pitfalls

Do not assume patient understanding based on device ownership; avoid letting patients rely solely on CGM alarms for hypoglycemia detection; do not skip SMBG education during CGM initiation; beware of overreliance on trend data without confirmatory fingersticks in acute situations.

Concrete Clinical Example

A 22‑year‑old with T1DM starts real‑time CGM and tells the clinician they no longer need fingersticks. Assessment reveals the misconception; the clinician explains that CGM requires twice‑daily SMBG calibration and that fingersticks are needed to verify symptoms or discrepant readings, then documents improved understanding.

Source: Diabetes Technology—Continuous Subcutaneous Insulin Infusion Therapy and Continuous Glucose Monitoring in Adults: An Endocrine Society Clinical Practice Guideline, Endocrine Society, 2016, DOI: 10.1210/jc.2016-2534

Use this skill with your AI agent: Open on Skill Issue to copy, download, or add to your library. Works with Claude, ChatGPT, Gemini, Cursor, Windsurf and more.