Endo assess cgm site selection care

From dromlakhani/MD2SKILL · View interactive version

Endo assess cgm site selection care is an AI agent skill from the GitHub repository dromlakhani/MD2SKILL. Evaluates patient’s selection of sensor insertion sites and site care to prevent irritation or infection. Triggers include: 'Review CGM site rotation', 'Check sensor site hygiene and adhesion'.

How to use this skill

Skill file

Assess CGM site selection and care

STEP 1 — Gather Information

Collect data on current CGM site(s), duration of use, skin condition (redness, itching, infection, induration), adhesion quality, rotation pattern, patient hygiene practices, understanding of site selection, any adhesive allergies, and use of skin prep or barrier products.

STEP 2 — Rule In / Rule Out

Determine if there are signs of site‑related complications (persistent erythema, induration, purulent discharge, lipohypertrophy, or frequent sensor loss due to poor adhesion). If present, rule in a site issue; if absent, rule out.

STEP 3 — Classify or Stratify

Classify site adequacy as: Adequate (no complications, proper rotation, good adhesion), Marginal (mild irritation, occasional adhesion failure, suboptimal rotation), or Inadequate (significant skin breakdown, infection, repeated sensor failures attributable to the site).

STEP 4 — Decide

Clinical Guardrails / Mimics / Pitfalls

Do not ignore mild erythema as it can progress to infection; avoid alcohol wipes immediately before insertion if they cause dryness; do not reuse a site without adequate healing time (≥2 weeks); avoid placing sensors over lipohypertrophy, scar tissue, or bony prominences; do not rely solely on patient self‑report without visual inspection of the site.

Concrete Clinical Example

A 58‑year‑old with type 1 diabetes reports frequent sensor detachment and mild itching at the abdomen site used for the past 6 weeks. Assessment shows localized erythema without drainage and adhesion failure after 3 days. Classified as Marginal. Intervention: educated on cleaning with mild soap/water, drying fully, applying a thin barrier wipe, rotating to the upper buttock, and using a skin‑tac adhesive patch. Sensor re‑inserted at the new site with no detachment or irritation at 1‑week follow‑up.

Source: Diabetes Technology—Continuous Subcutaneous Insulin Infusion Therapy and Continuous Glucose Monitoring in Adults: An Endocrine Society Clinical Practice Guideline, Endocrine Society, 2016, https://doi.org/10.1210/jc.2016-2534

Use this skill with your AI agent: Open on Skill Issue to copy, download, or add to your library. Works with Claude, ChatGPT, Gemini, Cursor, Windsurf and more.