Endo annual reassess cgm trend insulin adjust

From dromlakhani/MD2SKILL · View interactive version

Endo annual reassess cgm trend insulin adjust is an AI agent skill from the GitHub repository dromlakhani/MD2SKILL. Reassesses annually the patient’s ability to use CGM trend information to adjust insulin doses. Triggered by yearly CGM skills check or annual review of trend-based dosing competence.

How to use this skill

Skill file

Annually reassess ability to make insulin adjustment based on CGM trend information

STEP 1 — Gather Information

Collect patient logs of trend-based insulin adjustments (e.g., basal/bolus changes in response to rising/falling arrows), SMBG calibration frequency, sensor site condition, and alarm settings; if any data missing, schedule focused education before proceeding.

STEP 2 — Rule In / Rule Out

Determine whether the patient correctly interprets CGM trend data (direction and rate of change) and makes appropriate insulin dose adjustments; if yes, rule in competence; if no, rule out.

STEP 3 — Classify or Stratify

Classify competence level: Competent (independent, accurate trend‑based adjustments), Needs Retraining (occasional errors or reliance on caregiver), or Unable (requires caregiver for all trend‑based decisions).

STEP 4 — Decide

If Competent: continue current CGM‑based insulin regimen with annual reassessment; if Needs Retraining: provide targeted one‑on‑one training on trend interpretation and insulin adjustment; if Unable: involve caregiver in dose decisions or consider a simplified insulin regimen.

Clinical Guardrails / Mimics / Pitfalls

Do not rely solely on CGM trends without confirming with SMBG; avoid making insulin adjustments based on trend alone during rapid glucose changes; do not ignore alarm fatigue or sensor site irritation; never assume competence without direct observation of trend‑based decision making.

Concrete Clinical Example

A 48‑year‑year‑old with T1D using RT‑CGM user with T1D reviews logs showing they reduce basal rate by 10% when a downward trend arrow exceeds 2 mg/dL/min and confirm with fingerstick; they calibrate twice daily, rotate sensor sites, and report no severe hypoglycemia; deemed Competent, current plan continued.

Source: Diabetes Technology—Continuous Subcutaneous Insulin Infusion Therapy and Continuous Glucose Monitoring in Adults: An Endocrine Society Clinical Practice Guideline, Endocrine Society, 2016, https://doi.org/10.1210/jc.2016-2534

Use this skill with your AI agent: Open on Skill Issue to copy, download, or add to your library. Works with Claude, ChatGPT, Gemini, Cursor, Windsurf and more.