Endo annual reassess cgm site health

From dromlakhani/MD2SKILL · View interactive version

Endo annual reassess cgm site health is an AI agent skill from the GitHub repository dromlakhani/MD2SKILL. Reassesses annually the patient’s CGM sensor site health and care practices, including skin integrity, rotation, and hygiene. Triggered by phrases such as 'Yearly sensor site inspection' or 'Annual review of CGM insertion site rotation and hygiene'.

How to use this skill

Skill file

Annually reassess CGM sensor site health and care

STEP 1 — Gather Information

Collect: visual inspection of current and recent CGM sites for erythema, induration, infection, lipohypertrophy, or tape reaction; patient-reported site comfort and any itching/pain; history of site rotation frequency and locations used; hygiene practices (skin cleaning, drying, adhesive removal); ability to perform SMBG calibrations and use trend data for insulin adjustments; alarm settings and any alarm fatigue.

STEP 2 — Rule In / Rule Out

Is there any abnormal skin finding (redness >2 cm, induration, ulceration, infection, lipohypertrophy, or persistent tape irritation) at the CGM site?

STEP 3 — Classify or Stratify

Classify site health:

STEP 4 — Decide

Clinical Guardrails / Mimics / Pitfalls

Do not ignore subtle skin changes; do not reuse the same site repeatedly; do not skip SMBG calibrations assuming CGM is sufficient; do not dismiss alarm fatigue without reassessing alert thresholds; do not overlook lipohypertrophy from insulin infusion when assessing CGM sites.

Concrete Clinical Example

A 34‑year‑old with type 1 diabetes presents for annual review. Inspection of the abdomen CGM site shows a 1.5 cm area of mild erythema without induration or drainage. The patient reports rotating sites every 10–14 days but admits to sometimes reusing favorite spots. Skin is cleaned with alcohol wipes before insertion. Decision: erythema classified as needing reinforcement; educate on rotating at least 2 cm from prior site, using antiperspirant‑free skin prep, and avoiding areas of lipohypertrophy; continue CGM with same sensor after site change to adjacent healthy area.

Source: Diabetes Technology—Continuous Subcutaneous Infusion Therapy and Continuous Glucose Monitoring in Adults: An Endocrine Society Clinical Practice Guideline, Endocrine Society, 2016, DOI:10.1210/jc.2016-2534

Use this skill with your AI agent: Open on Skill Issue to copy, download, or add to your library. Works with Claude, ChatGPT, Gemini, Cursor, Windsurf and more.