Overview
CT scans contain a wide range of Hounsfield Unit (HU) values. A single window clips most diagnostic detail. Stacking three clinically-relevant windows — brain (W:80, L:40), subdural (W:200, L:80), and soft tissue (W:380, L:40) — as RGB channels preserves all three ranges in one image that standard ImageNet-pretrained CNNs can consume directly.
Quick Start
import pydicom
import numpy as np
def window_image(img, center, width, intercept, slope):
img = img * slope + intercept
img_min = center - width // 2
img_max = center + width // 2
return np.clip(img, img_min, img_max)
def multi_window_rgb(dcm):
px = dcm.pixel_array.astype(np.float32)
intercept, slope = float(dcm.RescaleIntercept), float(dcm.RescaleSlope)
brain = window_image(px, 40, 80, intercept, slope)
subdural = window_image(px, 80, 200, intercept, slope)
soft = window_image(px, 40, 380, intercept, slope)
# Normalize each channel to [0, 1]
brain = (brain - (40 - 40)) / 80
subdural = (subdural - (80 - 100)) / 200
soft = (soft - (40 - 190)) / 380
return np.stack([brain, subdural, soft], axis=-1)
Workflow
- Read DICOM and extract RescaleIntercept / RescaleSlope
- Apply three different window center/width pairs to raw pixel array
- Normalize each windowed image to [0, 1]
- Stack as 3-channel (H, W, 3) array — feed directly to pretrained CNN
Key Decisions
- Window choice: Brain (W:80 L:40) for parenchyma, Subdural (W:200 L:80) for extra-axial blood, Bone (W:380 L:40) for skull fractures. Adjust for task.
- Normalization: Divide by window width after shifting to zero-base. Keeps channels in [0, 1] range.
- vs. single window: Single window loses information outside its range. Multi-window retains three diagnostic views simultaneously.