Overview
Horizontal flip is one of the cheapest TTA tricks and almost always improves classification. But on datasets where labels are lateralized — left/right kidney, left/right common carotid, left/right ICA aneurysm — naive RandomHorizontalFlip is a silent disaster: the pixels flip but the target string still says "Left X". The model learns a wrong mapping and TTA averages predictions of two opposite labels. There are two valid responses: (A) disable horizontal flip everywhere, or (B) implement a flip+label-swap transform that simultaneously mirrors the image and swaps the corresponding column pairs in the target vector. (A) is simpler and bulletproof; (B) recovers the augmentation budget if you control the transforms tightly. Default to (A) unless you have label-pair metadata.
Quick Start
import albumentations as A
# Option A — safest: just disable horizontal flip
TRAIN_TFM = A.Compose([
A.Resize(384, 384),
# NO HorizontalFlip
A.VerticalFlip(p=0.5), # safe if no up/down semantics
A.Rotate(limit=15, p=0.5),
A.Normalize(),
])
TTA_TRANSFORMS = [] # no flip TTA
# Option B — flip + label swap (only if you have a pair table)
LR_PAIRS = [('Left ICA', 'Right ICA'), ('Left MCA', 'Right MCA'), ...]
def flip_with_label_swap(img, label_vec, cols):
img = img[:, ::-1, :].copy()
new = label_vec.copy()
for l, r in LR_PAIRS:
new[cols.index(l)], new[cols.index(r)] = label_vec[cols.index(r)], label_vec[cols.index(l)]
return img, new
Workflow
- Inspect label columns — any column starting with "Left" / "Right" or "L_" / "R_" is a red flag
- Decide between option A (disable) and option B (flip+swap with pair table)
- Remove
HorizontalFlipfrom the train transform pipeline (or wrap in a custom class for option B) - Remove flip variants from the TTA transform list
- Add a unit test: run the pipeline on a synthetic image with a left-only label and assert the post-augmentation label is unchanged
- Document the decision in the data-loading file so future contributors don't reintroduce it
Key Decisions
- Default to disable: the few percent TTA lift isn't worth a hidden label corruption.
- Vertical flip is usually safe for axial medical slices but check the dataset: spine images have head/foot semantics.
- Rotation > 30 degrees can also flip lateralization in specific projections — keep rotation modest.
- The bug is silent: validation metric drops by ~1-3 percentage points but no error is raised. Always check the label space before adding flip.
- Alternative: train two heads, one per side, with a single mirrored input — but this is overkill for most pipelines.
- Generalizes: any spatial-anatomy label (left/right hand, left/right ear), road-sign datasets (mirror-symmetric arrows), and OCR.