Checking hipaa compliance

From maziyarpanahi/openmed · View interactive version

Checking hipaa compliance is an AI agent skill from the GitHub repository maziyarpanahi/openmed. Runs a HIPAA Privacy and Security Rule checklist over a data pipeline and produces a gap report before deploying OpenMed on PHI. Use when the user is about to process protected health information, needs a pre-deployment compliance review, wants to know which administrative, physical, and technical s

How to use this skill

Skill file

Checking HIPAA compliance before deploying on PHI

Before any pipeline touches protected health information (PHI), the

operating entity (a covered entity or its business associate) must have the

HIPAA Privacy Rule and Security Rule safeguards in place. This skill

walks a concrete pipeline against those requirements and emits a gap report:

which controls are met, which are missing, and where OpenMed's on-device

de-identification and signed audit trail satisfy a requirement.

The full control list — administrative, physical, and technical safeguards with

their 45 CFR citations — is in

references/hipaa-checklist.md. This skill is a

self-assessment aid, not legal advice; a Privacy Officer signs off on

compliance.

When to use

go/no-go compliance review.

audit, a BAA, or a security questionnaire.

de-identification and record the rationale.

The two paths to "no longer PHI"

HIPAA recognizes two de-identification methods (45 CFR 164.514):

  1. Safe Harbor — remove all 18 identifier categories and have no actual

knowledge the result can re-identify. Deterministic, the common path.

  1. Expert Determination — a qualified statistician certifies "very small"

re-identification risk. Used when you must keep some quasi-identifiers.

OpenMed's deidentify(..., policy="hipaa_safe_harbor") targets the Safe Harbor

identifier set on-device, and deidentify(..., audit=True) produces a signed,

PHI-free AuditReport that documents what was removed — the evidence a Safe

Harbor attestation and a Security Rule audit control both want.

Quick start

import openmed

# A representative record from the pipeline (synthetic — never log real PHI).
sample = "John Doe (MRN 1234567), DOB 1970-01-15, seen 2024-03-02 in Boston."

# 1) De-identify on-device under the Safe Harbor policy.
result = openmed.deidentify(sample, method="replace", policy="hipaa_safe_harbor")
print(result.deidentified_text)        # identifiers removed/surrogated

# 2) Produce the signed, no-PHI audit record for the compliance file.
report = openmed.deidentify(sample, policy="hipaa_safe_harbor", audit=True)
report.sign(b"<release-hmac-key-from-vault>", key_id="hipaa-2026")

# 3) Walk the checklist (see references/hipaa-checklist.md) and record gaps.
controls = {
    "encryption_at_rest": True,
    "encryption_in_transit": True,
    "access_controls_rbac": True,
    "audit_logging": True,          # satisfied in part by the signed AuditReport
    "minimum_necessary": False,     # <-- gap: pipeline pulls full notes
    "baa_in_place": True,
    "deidentification_method": "safe_harbor",
}
gaps = [name for name, ok in controls.items() if not ok]
print("GAPS:", gaps)

Workflow

  1. Map the data flow. Diagram every place PHI is created, received,

maintained, or transmitted — including model caches, temp files, and logs.

  1. Confirm the legal basis. Is the operator a covered entity or business

associate? Is a BAA in place with every downstream vendor that touches

PHI? OpenMed running on-device means no third-party processor for the NLP

step — note that as a control in your favor.

  1. Run the three safeguard groups from

references/hipaa-checklist.md:

administrative (risk analysis, workforce training, sanctions),

physical (facility/device controls), and technical (access control, audit

controls, integrity, transmission security).

  1. Enforce minimum necessary. Pull only the fields the task needs; mask the

rest. De-identify as early in the flow as the use case allows.

  1. Record the de-identification method (Safe Harbor vs Expert Determination)

and attach the signed AuditReport as evidence.

  1. Emit the gap report — met / not-met / N/A per control, with the 45 CFR

citation and the remediation owner. Hand it to the Privacy Officer.

Hand-off to / from OpenMed

policy="hipaa_safe_harbor") is the technical control that converts PHI to

non-PHI on-device — the heart of a HIPAA pipeline.

to the 18 Safe Harbor categories so you can prove each is handled.

AuditReport.sign()/.verify()) gives the tamper-evident, PHI-free record the

Security Rule audit-controls standard (164.312(b)) expects.

traces (a recurring audit finding).

Edge cases & gotchas

requires all 18 categories removed and no actual knowledge of

re-identifiability. A residual rare ZIP3 or a free-text name the model missed

re-introduces PHI. Verify coverage; don't assume.

Agreement (164.514(e)) are not de-identified — different rules apply.

files holding raw notes are in scope. This is the most common gap.

transmits PHI on your behalf — including cloud storage and any LLM API. Running

OpenMed on-device avoids adding one for the NLP step.

charts when a problem list suffices.

duties; encryption to NIST standards renders data "secured" and can avoid the

notification trigger.

Officer's determination and (for Expert Determination) a qualified statistician.

Standards & references

Use this skill with your AI agent: Open on Skill Issue to copy, download, or add to your library. Works with Claude, ChatGPT, Gemini, Cursor, Windsurf and more.