Aoti debug

From Kilo-Org/kilo-marketplace · View interactive version

Aoti debug is an AI agent skill from the GitHub repository Kilo-Org/kilo-marketplace. Debug AOTInductor (AOTI) errors and crashes. Use when encountering AOTI segfaults, device mismatch errors, constant loading failures, or runtime errors from aot_compile, aot_load, aoti_compile_and_package, or aoti_load_package.

How to use this skill

Skill file

AOTI Debugging Guide

This skill helps diagnose and fix common AOTInductor issues.

Error Pattern Routing

Check the error message and route to the appropriate sub-guide:

Triton Index Out of Bounds

If the error matches this pattern:

Assertion `index out of bounds: 0 <= tmpN < ksM` failed

→ Follow the guide in triton-index-out-of-bounds.md

All Other Errors

Continue with the sections below.


First Step: Always Check Device and Shape Matching

For ANY AOTI error (segfault, exception, crash, wrong output), ALWAYS check these first:

  1. Compile device == Load device: The model must be loaded on the same device type it was compiled on
  2. Input devices match: Runtime inputs must be on the same device as the compiled model
  3. Input shapes match: Runtime input shapes must match the shapes used during compilation (or satisfy dynamic shape constraints)
# During compilation - note the device and shapes
model = MyModel().eval()           # What device? CPU or .cuda()?
inp = torch.randn(2, 10)           # What device? What shape?
compiled_so = torch._inductor.aot_compile(model, (inp,))

# During loading - device type MUST match compilation
loaded = torch._export.aot_load(compiled_so, "???")  # Must match model/input device above

# During inference - device and shapes MUST match
out = loaded(inp.to("???"))  # Must match compile device, shape must match

If any of these don't match, you will get errors ranging from segfaults to exceptions to wrong outputs.

Key Constraint: Device Type Matching

AOTI requires compile and load to use the same device type.

Common Error Patterns

1. Device Mismatch Segfault

Symptom: Segfault, exception, or crash during aot_load() or model execution.

Example error messages:

Cause: Compile and load device types don't match (see "First Step" above).

Solution: Ensure compile and load use the same device type. If compiled on CPU, load on CPU. If compiled on CUDA, load on CUDA.

2. Input Device Mismatch at Runtime

Symptom: RuntimeError during model execution.

Cause: Input device doesn't match compile device (see "First Step" above).

Better Debugging: Run with AOTI_RUNTIME_CHECK_INPUTS=1 for clearer errors. This flag validates all input properties including device type, dtype, sizes, and strides:

AOTI_RUNTIME_CHECK_INPUTS=1 python your_script.py

This produces actionable error messages like:

Error: input_handles[0]: unmatched device type, expected: 0(cpu), but got: 1(cuda)

Debugging CUDA Illegal Memory Access (IMA) Errors

If you encounter CUDA illegal memory access errors, follow this systematic approach:

Step 1: Sanity Checks

Before diving deep, try these debugging flags:

AOTI_RUNTIME_CHECK_INPUTS=1
TORCHINDUCTOR_NAN_ASSERTS=1

These flags take effect at compilation time (at codegen time):

Step 2: Pinpoint the CUDA IMA

CUDA IMA errors can be non-deterministic. Use these flags to trigger the error deterministically:

PYTORCH_NO_CUDA_MEMORY_CACHING=1
CUDA_LAUNCH_BLOCKING=1

These flags take effect at runtime:

Step 3: Identify Problematic Kernels with Intermediate Value Debugger

Use the AOTI Intermediate Value Debugger to pinpoint the problematic kernel:

AOT_INDUCTOR_DEBUG_INTERMEDIATE_VALUE_PRINTER=3

This prints kernels one by one at runtime. Together with previous flags, this shows which kernel was launched right before the error.

To inspect inputs to a specific kernel:

AOT_INDUCTOR_FILTERED_KERNELS_TO_PRINT="triton_poi_fused_add_ge_logical_and_logical_or_lt_231,_add_position_embeddings_kernel_5" AOT_INDUCTOR_DEBUG_INTERMEDIATE_VALUE_PRINTER=2

If inputs to the kernel are unexpected, inspect the kernel that produces the bad input.

Additional Debugging Tools

Logging and Tracing

Common Sources of Issues

API Notes

Deprecated API

torch._export.aot_compile()  # Deprecated
torch._export.aot_load()     # Deprecated

Current API

torch._inductor.aoti_compile_and_package()
torch._inductor.aoti_load_package()

The new API stores device metadata in the package, so aoti_load_package() automatically uses the correct device type. You can only change the device index (e.g., cuda:0 vs cuda:1), not the device type.

Environment Variables Summary

| Variable | When | Purpose |

|----------|------|---------|

| AOTI_RUNTIME_CHECK_INPUTS=1 | Compile time | Validate inputs match compilation guards |

| TORCHINDUCTOR_NAN_ASSERTS=1 | Compile time | Check for NaN before/after kernels |

| PYTORCH_NO_CUDA_MEMORY_CACHING=1 | Runtime | Make IMA errors deterministic |

| CUDA_LAUNCH_BLOCKING=1 | Runtime | Force synchronous kernel launches |

| AOT_INDUCTOR_DEBUG_INTERMEDIATE_VALUE_PRINTER=3 | Compile time | Print kernels at runtime |

| TORCH_LOGS="+inductor,output_code" | Runtime | See PT2 internal logs |

| TORCH_SHOW_CPP_STACKTRACES=1 | Runtime | Show C++ stack traces |

Use this skill with your AI agent: Open on Skill Issue to copy, download, or add to your library. Works with Claude, ChatGPT, Gemini, Cursor, Windsurf and more.