Dia analysis

From GPTomics/bioSkills · View interactive version

Dia analysis is an AI agent skill from the GitHub repository GPTomics/bioSkills. Analyzes data-independent acquisition (DIA) proteomics by scoring reconstructed fragment-chromatogram peak groups against a decoy null with DIA-NN (library-free directDIA, library-based, or deep-learning predicted-library routes), Spectronaut, OpenSWATH, and EncyclopeDIA. Frames the deliverable arou

How to use this skill

Skill file

Version Compatibility

Reference examples tested with: DIA-NN 1.9+, pandas 2.2+, pyarrow 15+

Before using code patterns, verify installed versions match. If versions differ:

If code throws ImportError, AttributeError, or TypeError, introspect the installed

package and adapt the example to match the actual API rather than retrying.

DIA Analysis -- Scoring Reconstructed Peak Groups Against a Decoy Null, Filtered at the Right q-Value Context

"Identify and quantify proteins from my DIA runs" -> Reconstruct, per candidate peptide, a set of co-eluting fragment extracted-ion chromatograms (XICs) and score whether that peak group is real against a decoy null -- because every wide-isolation-window MS2 is chimeric, so the problem is deconvolution and peak-group scoring, not spectrum matching.

Scope: this skill OWNS running the DIA search engine and FILTERING its output at the correct q-value level and context. Building the library (experimental, chromatogram, predicted) -> spectral-libraries. Normalization, MaxLFQ roll-up, and matrix summarization -> quantification. Statistical testing of the protein matrix -> differential-abundance. Loading raw vendor/mzML data -> data-import. OUT OF SCOPE: DDA spectrum-to-peptide matching (peptide-identification); pathway enrichment of the hit list; acquiring the data (the analyst inherits the window design from the core facility).

The Single Most Important Modern Insight -- The q-Value Context Is a Study-Design Choice, Not a Default

  1. DIA quantification is peak-group SCORING against a decoy null, not spectrum matching. Gillet 2012 inverted DDA: instead of asking "what peptide is this spectrum", DIA asks, per library peptide, "does a co-eluting peak group of this peptide's expected fragments exist in the chimeric MS2 stream". Decoys are shuffled or reversed peptide queries scored identically; the q-value is the expected fraction of accepted IDs that are decoy-like false peak groups. The count of "proteins found" is therefore a function of the decoy-calibrated threshold, never a quality metric in itself.
  1. "1% FDR" is meaningless without naming the LEVEL and the CONTEXT -- state both. LEVEL = precursor vs peptide vs protein-group (filtering precursors at 1% does NOT give proteins at 1%; control both). CONTEXT = run-specific vs experiment-wide vs global (Rosenberger 2017). Naively filtering N runs at per-run 1% inflates the experiment-wide error: 1% per run accumulates false positives across the union, severe at hundreds-to-thousands of runs. For a cross-run matrix, filter on the GLOBAL protein-group q-value, not the per-run one. The column chosen (Q.Value vs Global.PG.Q.Value) is the decision.
  1. The predicted-library route is now the default recommendation. Library-based search is sensitive but capped by an ill-matched library (wrong organism/tissue/mods silently limits coverage with no error). Library-free directDIA finds sample-specific content but its larger implicit search space can INFLATE IDs if FDR is not controlled across the two-pass process -- worst on wide-window chimeric data. The compromise the field converged on: predict an in-silico library for the whole FASTA digest (DIA-NN built-in predictor, or Prosit/AlphaPeptDeep) and search against THAT, getting directDIA's "no wet-lab library" with library-based's bounded, better-calibrated search.

Chimerism, Deconvolution, and the Window Design the Analyst Inherits

DDA picks top-N precursors and fragments each in isolation, so every MS2 is nominally one peptide. DIA abandons selection: the quadrupole steps through wide isolation windows (4-25 Th classically, 2 Th on Astral, mobility-gated on timsTOF) and co-fragments EVERY precursor in each window. Consequence: every DIA MS2 is chimeric, a superposition of fragments from all co-isolated precursors. The engine must deconvolve -- reconstruct each candidate's fragment XICs and score the peak group.

Selectivity is set by isolation-window WIDTH. Narrower window = fewer co-isolated precursors = less chimerism = cleaner XICs = fewer false peak groups. But narrower windows mean MORE windows per cycle -> longer duty cycle -> fewer points across each LC peak -> worse quant precision. The central acquisition tradeoff is duty cycle (sampling speed) vs selectivity (window width). Rule of thumb: aim for >= 6 MS2 points across the FWHM of an LC peak for reliable quant. The analyst INHERITS this design and must not pretend all DIA is equivalent:

Tool Taxonomy

| Tool / method | Citation | Mechanism / role | When |

|---------------|----------|------------------|------|

| DIA-NN | Demichev 2020 | Deep-NN peak-group scoring + interference correction + QuantUMS quant; library-free, predicted, or library-based | Default for high-throughput, large cohorts, diaPASEF, Astral; free, scriptable |

| Spectronaut | Biognosys (commercial) | directDIA+ pipeline with in-app DL prediction; mature GUI/QC | Regulated/clinical work, polished QC, mixed vendors, when licensed |

| OpenSWATH + PyProphet | Rost 2014; Rosenberger 2017 | Classic peptide-centric extraction + semi-supervised scoring with explicit run/experiment/global q-contexts | When auditable FDR-context control is required; library-based ONLY, needs iRT/RT alignment |

| EncyclopeDIA / Walnut | Searle 2018 | Chromatogram-library search (.dlib/.elib) + GPF; Walnut = library-free mode | Building project-specific chromatogram-library depth on Orbitrap |

| FragPipe (MSFragger-DIA / DIA-Umpire) | -- | Spectrum-centric via pseudo-spectra + Philosopher FDR; IonQuant explicit MBR-FDR | Unified DDA+DIA shop in the MSFragger ecosystem |

| Skyline | MacCoss lab | Targeted/visual peak inspection and demultiplexing; not a discovery engine | Manual peak curation, PRM, library curation -- the microscope, not the engine |

| AlphaDIA | Mann lab | Open transformer-based end-to-end Python; AlphaPeptDeep predictions | Cutting-edge open research, Astral, Python-native pipelines |

| Library build | (route OUT) | Experimental/chromatogram/predicted library construction | -> spectral-libraries |

| Stats on the matrix | (route OUT) | Normalization, roll-up, moderated testing | -> quantification, differential-abundance |

Tool leadership moves fast (Astral, AlphaDIA, DIA-NN releases). Confirm the current recommended engine and version for the specific instrument before committing rather than hard-coding "DIA-NN is best".

Decision Tree by Scenario

| Scenario | Recommended | Why |

|----------|-------------|-----|

| Discovery cohort, no wet-lab library | diann --fasta-search --gen-spec-lib (predicted route) then search against it | Bounded, better-calibrated search vs raw directDIA; the modern default |

| Quick single-run discovery, Astral 2-Th data | DIA-NN library-free (directDIA) | Near-non-chimeric MS2 makes directDIA trustworthy |

| Have a deep experimental/chromatogram library | diann --lib library.tsv (no --fasta-search) | Targeted extraction is most sensitive when the library matches |

| Need auditable run/experiment/global FDR for a regulated submission | OpenSWATH + PyProphet | Explicit q-value contexts per Rosenberger 2017 |

| Building chromatogram-library depth for one project on Orbitrap | EncyclopeDIA (GPF) -> .elib -> DIA-NN | Empirical RT and real fragmentation in the project's own LC |

| Large cohort (hundreds-thousands of runs) | DIA-NN --reanalyse, filter on Global.PG.Q.Value | Two-pass global FDR controls cross-run error accumulation |

| Staggered/overlapping acquisition | Demultiplex at conversion FIRST, then any engine | Skipping demux silently keeps wide-window interference |

| PTM / peptidoform-resolved work | DIA-NN --peptidoforms + matched variable mods | Peptidoform-resolved target-decoy scoring |

Default when uncertain: DIA-NN with the predicted-library route (--fasta-search --gen-spec-lib --reanalyse), letting --mass-acc 0 auto-optimize, then filter Q.Value <= 0.01 & PG.Q.Value <= 0.01 per run and Global.PG.Q.Value <= 0.01 for cross-run matrices.

DIA-NN -- Predicted-Library (directDIA) Route

The default route: digest the FASTA in silico, predict a library, and search the DIA data against it in one command. --mass-acc 0 lets DIA-NN auto-optimize tolerances per file (do not hard-code ppm from another instrument). --reanalyse enables the two-pass global FDR / MBR that controls directDIA double-dipping.

diann \
    --f sample1.mzML --f sample2.mzML \
    --lib "" --fasta uniprot_human.fasta --fasta-search \
    --gen-spec-lib --predictor \
    --out diann_out/report.parquet \
    --out-lib diann_out/report-lib.tsv \
    --qvalue 0.01 \
    --matrices \
    --mass-acc 0 \
    --reanalyse --smart-profiling \
    --cut K*,R* --missed-cleavages 1 \
    --min-pep-len 7 --max-pep-len 30 \
    --unimod4 --var-mods 1 --var-mod UniMod:35,15.994915,M \
    --threads 8

DIA-NN -- Library-Based Route

Supply an existing library (experimental, chromatogram-derived, or a previously predicted .speclib). Omit --fasta-search: extraction is targeted to the library content.

diann \
    --f sample1.mzML --f sample2.mzML \
    --lib spectral_library.tsv \
    --out diann_out/report.parquet \
    --qvalue 0.01 --matrices \
    --mass-acc 0 \
    --reanalyse --smart-profiling \
    --threads 8

DIA-NN Output and Correct Filtering

DIA-NN 1.9+ writes the main report as Apache Parquet (report.parquet) by default; 2.0 makes it the only default. Matrices stay TSV. Pipelines hard-coding report.tsv silently break or read a stale file -- read parquet. Filter on q-value columns BEFORE pivoting to a matrix.

report.parquet          # main report (1.9+ default; was report.tsv pre-1.9)
report.stats.tsv        # per-run statistics
report.pg_matrix.tsv    # protein-group wide matrix
report.pr_matrix.tsv    # precursor wide matrix (verify exact dotting vs installed version)
report.gg_matrix.tsv    # gene-group wide matrix
report-lib.tsv          # generated library (if --gen-spec-lib)
import pandas as pd, numpy as np
report = pd.read_parquet('diann_out/report.parquet')  # NOT report.tsv on 1.9+

# Per-run filter: both LEVELS. Add Global.PG.Q.Value for the cross-run matrix.
filt = report[(report['Q.Value'] <= 0.01) &
              (report['PG.Q.Value'] <= 0.01) &
              (report['Global.PG.Q.Value'] <= 0.01)]  # 0.01 = standard 1% FDR

# Pivot to a protein matrix from the filtered long report.
pg = filt.pivot_table(index='Protein.Group', columns='Run', values='PG.MaxLFQ', aggfunc='first')
pg = np.log2(pg.replace(0, np.nan))  # DIA-NN writes 0 for not-quantified; log2(0) = -Inf

The *_matrix.tsv files apply an EXTRA 5% run-specific protein FDR (DIA-NN default, --matrix-spec-q), so the matrix protein count can be lower than the report count. A report-vs-matrix mismatch is EXPECTED, not a bug -- do not panic and do not compare the two counts as if they should match.

Generating a Predicted Library Outside DIA-NN

DIA-NN's built-in predictor covers the common case. For an external predicted library from FragPipe search results, EasyPQP builds it; FragPipe can also emit a DIA-NN-format library directly.

# Real easypqp subcommands: library, convert, insilico-library (NOT a convert --format diann).
easypqp library \
    --psmtsv psm.tsv \
    --rt_reference irt.tsv \
    --peptide_fdr_threshold 0.01 \
    --protein_fdr_threshold 0.01 \
    --out library.tsv
# FragPipe's DIA workflow can emit a DIA-NN-format library directly -- prefer that when in FragPipe.

Per-Method Failure Modes

Library-free (directDIA)

Trigger: --fasta-search on wide-window (25-Th SWATH) data without two-pass global FDR.

Mechanism: building the library from the same data then quantifying it reuses the data twice; the large implicit search space inflates IDs when decoys are not controlled across both passes.

Symptom: implausibly high protein counts, poor reproducibility across replicates.

Fix: keep --reanalyse (two-pass global FDR) ON and filter on Global.PG.Q.Value; prefer the predicted-library route on chimeric data.

Library-based

Trigger: library organism/tissue/modifications/gradient do not match the sample.

Mechanism: targeted extraction can only find what is in the library; a mismatched library caps coverage with no error.

Symptom: low ID counts, conserved-peptide bias (e.g. a human library on a mouse sample finds only conserved peptides).

Fix: match the library to the biology (mods especially); regenerate via spectral-libraries or switch to the predicted route.

Cross-run cohort FDR

Trigger: filtering N runs at per-run Q.Value <= 0.01 and unioning.

Mechanism: 1% per run accumulates across the union -> experiment-wide error far above 1%.

Symptom: inflated total protein list; irreproducible "hits" in differential testing.

Fix: filter on Global.PG.Q.Value <= 0.01 (and optionally Lib.PG.Q.Value <= 0.01) for the matrix.

Match-between-runs (MBR)

Trigger: treating MBR-transferred quant values as equally confident as directly identified ones.

Mechanism: transferring an ID by RT/m/z/CCS matching can be a false transfer, especially for low-abundance precursors; MBR has its OWN FDR.

Symptom: spurious low-abundance quant filling missing values that should stay missing.

Fix: rely on DIA-NN's global/empirical-library q-values (IonQuant uses an explicit MBR-FDR model); do not disable --reanalyse then trust per-run counts.

Staggered acquisition

Trigger: running staggered/overlapping data through any engine without demultiplexing.

Mechanism: the engine sees the wide physical window, keeping all the interference the staggering was meant to remove.

Symptom: noisy directDIA, poor selectivity on data that should be clean.

Fix: demultiplex at conversion (msconvert --filter "demultiplex optimization=overlap_only") before search.

Quantitative Thresholds

| Threshold | Source | Rationale |

|-----------|--------|-----------|

| Precursor q-value <= 0.01 | DIA-NN default (--qvalue 0.01) | Standard 1% per-precursor FDR (run context). |

| Global.PG.Q.Value <= 0.01 | Rosenberger 2017 | Experiment-wide protein-group FDR for cross-run matrices; run-specific PG q-value is NOT enough for a cohort. |

| Matrix run-specific PG filter 0.05 | DIA-NN default (--matrix-spec-q) | Extra 5% run-specific protein FDR applied only when building matrices -> report vs matrix count differs (expected). |

| Lib.(PG.)Q.Value <= 0.01 | Demichev recommendation | For very large cohorts, also filter the global library-pass q-values to keep experiment-wide FDR honest. |

| Points per peak >= 6 across FWHM | community rule of thumb | Below this, quant precision and peak detection degrade; drives window/cycle design. |

| Mass accuracy auto (--mass-acc 0) | DIA-NN | Wrong tolerance silently kills IDs; let DIA-NN auto-calibrate rather than hard-coding ppm from another instrument. |

| Missed cleavages 1 | -- | Trypsin standard; raising it expands the search space and the multiple-testing burden. |

Common Errors

| Error / symptom | Cause | Solution |

|-----------------|-------|----------|

| FileNotFoundError: report.tsv or stale data | DIA-NN 1.9+ default is report.parquet, not report.tsv | Read report.parquet (pd.read_parquet); request legacy TSV explicitly only if needed |

| Matrix protein count < report count, looks like data loss | Matrices apply an extra 5% run-specific PG filter | Expected; do not compare the two counts as if equal |

| -Inf after log2 of the matrix | DIA-NN writes 0 for not-quantified | Convert 0 -> NaN BEFORE log2/normalization |

| Cohort "hits" do not reproduce | Filtered per-run Q.Value only, not global | Filter Global.PG.Q.Value <= 0.01 for the matrix |

| easypqp convert --format diann errors | No such interface; convert/library/insilico-library are the real subcommands | Use easypqp library (with --psmtsv/--rt_reference) or let FragPipe emit a DIA-NN-format library |

| KeyError: 'report.pr.matrix.tsv' | Matrix filename dotting varies by version (pr_matrix vs pr.matrix) | ls the output dir after a run and match the installed version's exact names |

| directDIA looks noisy on overlapping-window data | Staggered data not demultiplexed | Demultiplex at conversion before search |

References

Related Skills