Tooluniverse product safety surveillance

From mims-harvard/ToolUniverse · View interactive version

Tooluniverse product safety surveillance is an AI agent skill from the GitHub repository mims-harvard/ToolUniverse. Post-market safety surveillance and recall/adverse-event RETRIEVAL across the full spectrum of FDA-regulated products that are NOT covered by the drug-AE signal skills: medical devices, food / dietary supplements / cosmetics, veterinary drugs, and drug supply (shortages). Orchestrates openFDA endpoi

How to use this skill

Skill file

Product Safety Surveillance (multi-product, openFDA)

Retrieve and interpret post-market safety records across **every FDA-regulated

product class except drug-AE signal mining**: medical devices, food / dietary

supplements / cosmetics, veterinary drugs, and drug supply (shortages), plus

cross-product enforcement/recall reports.

KEY PRINCIPLES

  1. Decide the product class first. Device? Food/supplement/cosmetic? Vet drug? Drug shortage? Recall? The class picks the tool.
  2. Build a valid Lucene query. openFDA uses field-scoped field:value terms; combine with a space-separated AND. Phrases and special characters need care (see Query Grammar).
  3. Retrieve, then interpret. These are spontaneous/voluntary reports. Report the records and their fields; never assert causation or rates.
  4. Cite every record with the tool name, the openFDA endpoint, the query used, and the total hit count from meta.results.total.
  5. Stay in scope. If the request is drug-AE signal detection (PRR/ROR/IC), STOP and point to tooluniverse-pharmacovigilance / tooluniverse-adverse-event-detection.

When to Use vs When NOT to Use

USE for:

DO NOT USE for (point elsewhere):

This skill retrieves and interprets multi-product safety records. It does not compute drug-AE signal statistics.


Tool Map (which tool for which question)

| Product class | Question | Tool | openFDA endpoint |

|---|---|---|---|

| Device | Adverse events / malfunctions / deaths (MAUDE) | OpenFDA_search_device_adverse_events | /device/event.json |

| Device | Recalls | OpenFDA_search_device_recalls | /device/recall.json |

| Device | Enforcement / recall reports | OpenFDA_search_device_enforcement | /device/enforcement.json |

| Device | 510(k) clearances (context) | OpenFDA_search_device_510k | /device/510k.json |

| Device | Unique Device Identifier (UDI) lookup | OpenFDADevice_search_udi | -- |

| Device | US regulatory class (1/2/3) | OpenFDADevice_get_classification | -- |

| Device | Premarket Approval (PMA, Class 3 devices) | OpenFDADevice_search_pma | -- |

| Food/supplement/cosmetic | Adverse events (CAERS) | OpenFDA_search_food_adverse_events | /food/event.json |

| Food | Enforcement / recall reports | OpenFDA_search_food_enforcement | /food/enforcement.json |

| Veterinary | Animal drug adverse events | OpenFDA_search_animalvet_adverse_events | /animalandveterinary/event.json |

| Drug supply | Shortages | OpenFDA_search_drug_shortages | /drug/shortages.json |

| Drug | Enforcement / recall reports | OpenFDA_search_drug_enforcement | /drug/enforcement.json |

| Drug | Adverse events (raw FAERS records) | OpenFDA_search_drug_events | /drug/event.json |

| Drug | Labels | OpenFDA_search_drug_labels | /drug/label.json |

All tools take a Lucene search string plus optional limit and skip. All are keyless and verified live.

Note: OpenFDADevice_search_recalls/_search_adverse_events/_search_510k return the same underlying openFDA data as OpenFDA_search_device_recalls/_device_adverse_events/_device_510k above (two independently-added wrappers over the same endpoints) — either works, no need to call both. Use whichever is already in your loaded toolset; the OpenFDADevice_* family additionally has the three UDI/classification/PMA tools with no equivalent in the other family.


openFDA Query Grammar (CRITICAL — read before querying)


Interpretation Tables (raw openFDA field → meaning)

Medical devices — MAUDE adverse events (`/device/event.json`)

| Field | Meaning |

|---|---|

| event_type | Death, Injury, Malfunction, or No answer provided. Death/Injury = patient harm; Malfunction = device failure without (reported) harm. |

| device[].generic_name / device[].brand_name | Device category / trade name. |

| device[].manufacturer_d_name | Device manufacturer. |

| patient[] | Patient-level outcome data (may be sparse). |

| mdr_text[].text | Narrative; text_type_code distinguishes event description vs manufacturer narrative. |

| report_number | MAUDE report id. Duplicate / follow-up reports of the same event are common — do not count reports as distinct events. |

| date_received | YYYYMMDD FDA received date. |

Medical devices — recalls (`/device/recall.json`)

| Field | Meaning |

|---|---|

| product_description | What was recalled. |

| recalling_firm | Firm issuing the recall. |

| recall_status | e.g. Open, Terminated. Terminated = FDA closed the action. |

| product_code | FDA device product code. |

| k_numbers[] | Associated 510(k) clearance numbers. |

| root_cause_description | FDA root-cause category (e.g. Labeling design). |

| event_date_initiated | YYYY-MM-DD recall start. |

Enforcement reports (device / drug / food `/.../enforcement.json`)

| Field | Meaning |

|---|---|

| classification | Recall severity: Class I (serious/fatal hazard), Class II (temporary/reversible), Class III (unlikely to cause harm). |

| status | Ongoing / Terminated / Completed. |

| reason_for_recall | Why recalled. |

| product_description | Recalled product. |

| recalling_firm | Firm. |

Food / supplement / cosmetic — CAERS adverse events (`/food/event.json`)

| Field | Meaning |

|---|---|

| reactions[] | MedDRA reaction terms (British spelling, e.g. Diarrhoea, Nausea). |

| outcomes[] | e.g. Hospitalization, Life Threatening, Disability, Death, Other Serious or Important Medical Event, Visited an ER. |

| products[].industry_name | Product category (Cosmetics, Dietary Conventional Foods/Meal Replacements, Milk/Butter/Dried Milk Prod, …). |

| products[].role | SUSPECT (implicated) vs CONCOMITANT (also consumed). |

| products[].name_brand | Brand name. |

| consumer | age, gender of the consumer (often sparse). |

Veterinary — animal drug adverse events (`/animalandveterinary/event.json`)

| Field | Meaning |

|---|---|

| animal.species | Dog, Cat, Horse, … |

| animal.gender | Animal sex. |

| number_of_animals_affected | Count in the report. |

| reaction[].veddra_term_name | VeDDRA clinical sign (e.g. Vomiting, Diarrhoea). |

| drug[].brand_name / drug[].active_ingredients[].name | Implicated product / active. |

| drug[].used_according_to_label / off_label_use | Label vs off-label use. |

Drug shortages (`/drug/shortages.json`)

| Field | Meaning |

|---|---|

| status | Current or Resolved. |

| availability | e.g. Unavailable, Limited. |

| generic_name | Drug in shortage. |

| shortage_reason | e.g. Delay in shipping of the drug, Demand increase for the drug. |

| dosage_form | e.g. Injection, Tablet. |

| therapeutic_category[] | Clinical category. |

| company_name | Manufacturer. |

| update_type / initial_posting_date / update_date | Posting metadata. |


Workflow

  1. Classify the product from the request (device / food-supplement-cosmetic / vet / drug shortage / recall).
  2. Pick the tool from the Tool Map.
  3. Build the Lucene query following Query Grammar (single field for a first pass; add AND for combinations). Keep values simple; avoid special characters.
  4. Run it and read data.meta.results.total and data.results[].
  5. Interpret the fields with the table above. For severity: device event_type:Death; enforcement classification:Class I; CAERS outcomes:Death/Hospitalization; shortage status:Current.
  6. Summarize and cite. Report counts, key fields, the query used, and the LIMITATIONS caveat. To rank terms, pull limit:100 and tally in Python (no count aggregation in these wrappers).
  7. If out of scope (drug-AE signal/PRR/ROR), stop and route to the pharmacovigilance skills.

Worked Examples (verified live)

Example 1 — Device deaths for a device type (MAUDE)

"Are there any reported deaths in adverse-event reports for pacemakers?"

OpenFDA_search_device_adverse_events {"search":"device.generic_name:pacemaker AND event_type:Death","limit":1}

Real output (abbrev): status:success, meta.results.total = 16619; first record event_type = Death, device.generic_name = DEFIBRILLATOR/PACEMAKER.

Interpretation: 16,619 MAUDE reports match a pacemaker device with a Death event type. These are spontaneous reports — duplicates likely, and "Death" means a death was reported in temporal association, not that the device caused it.

Example 2 — Device recalls for a firm

"What device recalls has Medtronic Navigation issued?"

OpenFDA_search_device_recalls {"search":"recalling_firm:Medtronic","limit":1}

Real output (abbrev): total = 1896; first record recall_status = Terminated, product_code = HAW, root_cause_description = Labeling design, k_numbers = ["K990214"], event_date_initiated = 2011-01-20, product_description = a tactile probe for spine surgery.

Interpretation: 1,896 recall records match firms containing "Medtronic". recall_status: Terminated means FDA has closed this action; the root cause was a labeling-design issue.

Example 3 — Drug shortage lookup for an injectable

"Is ketorolac injection in shortage right now?"

OpenFDA_search_drug_shortages {"search":"dosage_form:Injection AND status:Current","limit":1}

Real output (abbrev): total = 799; first record generic_name = Ketorolac Tromethamine Injection, status = Current, shortage_reason = Delay in shipping of the drug, availability = Unavailable, company_name = Fresenius Kabi USA, LLC.

Interpretation: 799 current shortage records are injectables; ketorolac tromethamine injection is currently in shortage (status Current, availability Unavailable) due to a shipping delay.

Example 4 — Supplement / cosmetic CAERS reactions

"Are there CAERS adverse-event reports implicating cosmetics?"

OpenFDA_search_food_adverse_events {"search":"products.industry_name:Cosmetics","limit":1}

Real output (abbrev): total = 52214; first record products[].industry_name = Cosmetics, products[].role = SUSPECT, outcomes = ["Hospitalization","Other Serious or Important Medical Event"].

Interpretation: 52,214 CAERS reports name a cosmetic product as SUSPECT. CAERS is voluntary; a SUSPECT role reflects the reporter's attribution, not a verified causal link.

Example 5 — Veterinary adverse events for a drug in a species

"What adverse events are reported for carprofen in dogs?"

OpenFDA_search_animalvet_adverse_events {"search":"drug.active_ingredients.name:carprofen AND animal.species:Dog","limit":1}

Real output (abbrev): total = 46469; first record animal.species = Dog, reaction[].veddra_term_name includes Leucocytosis NOS, Neutrophilia, Depression, Elevated alanine aminotransferase (ALT).

Interpretation: 46,469 veterinary reports match carprofen-containing products in dogs. VeDDRA terms describe reported clinical signs; counts reflect reporting, not incidence.


Limitations (state these in every report)

See references/openfda_fields.md for the full per-endpoint field reference and additional query examples.


References

Use this skill with your AI agent: Open on Skill Issue to copy, download, or add to your library. Works with Claude, ChatGPT, Gemini, Cursor, Windsurf and more.