Daemons

From stevengonsalvez/agents-in-a-box · View interactive version

Daemons is an AI agent skill from the GitHub repository stevengonsalvez/agents-in-a-box. Runtime-health view of the four fleet daemons — phone bridge, notifyd, ATC, and the fleet auto-continue daemon — in one table. Each row reports state (running / stopped / unknown), pid, uptime, last activity, error count, and a HEALTH reason that distinguishes a clean stop from a crash (stale heartb

How to use this skill

Skill file

ainb fleet:daemons — daemon health view

The runtime-health answer for the fleet's four background daemons. Reads the

on-disk liveness signals each daemon already maintains and renders one typed

row per daemon. The same aggregator (fleet::daemons::collect) backs the TUI

Daemons screen, so the CLI and the TUI can never drift.

This is the question ainb fleet bridge status could never answer: that verb

reports only install state. daemons reports whether the process is

actually running and serving right now — a crashed-but-installed bridge

shows stopped with a stale-heartbeat reason here.

The four daemons

| daemon | id | how it's probed |

|---|---|---|

| phone bridge | bridge | heartbeat file (~/.agents-in-a-box/daemons/bridge.json) + pid-identity cross-check |

| notifyd | notifyd | PID-file liveness + bound Unix socket + sqlite DB file present |

| ATC | atc | mode-dependent: in full, the most-recently-beating instance's heartbeat-state.json (timer-driven; no resident pid); in lite, the scan loop's own heartbeat + pid |

| fleet daemon | fleet-daemon | heartbeat file + pid-identity cross-check — conditional row, see below |

Rows are emitted in this exact order (bridge, notifyd, ATC, then the fleet

daemon when it has a row), even when every daemon is stopped — so "everything

stopped" is a legible table, never an empty one.

The fleet daemon is a conditional row. ATC is the fleet's supervisor and the

standalone daemon is what it replaced, so a permanently-stopped row for it

presented the two as a choice — the competing control path the supervisor exists

to remove, still on the screen you read to see who is running. It is therefore

listed only when it is NOT stopped.

That is deliberately not "always hidden". A daemon that is up got there through

--force-race, which means two controllers really are auto-continuing the same

panes and ATC's per-session retry cap cannot hold. That row appears, reports

degraded, and its reason opens with RACING ATC. Hiding it would make the one

state you most need to see the only one the screen does not show.

The row is only a display decision: ainb daemon fleet-daemon start|stop|restart

keeps working whether or not a row is drawn.

Run

ainb fleet daemons                       # fixed-width text table (default)
ainb --format json fleet daemons         # typed rows for scripting

--format is a global flag — it goes before fleet. There are no other

flags or subcommands; daemons is a pure read.

Text columns

DAEMON         STATE      PID      UPTIME     LAST ACTIVITY  ERRORS  HEALTH

(e.g. Telegram (@bot) — running + connected); otherwise the reason string,

which is the load-bearing field for telling a clean stop from a crash.

States and what they mean (JSON `state` + `reason`)

| state | reason examples | meaning |

|---|---|---|

| running | running + connected, running (connecting…), running but socket not bound yet | process alive and heartbeating / serving |

| stopped | no heartbeat — not running this session, stale heartbeat — pid 4242 not alive (crashed), stale heartbeat — pid 4242 recycled (different process, crashed), stale heartbeat — last beat 130s ago (wedged?), no ATC instance provisioned, N instance(s) provisioned, all heartbeat-disabled | not serving — the reason says clean-stop vs crash vs never-configured |

| unknown | (probe error) | the probe itself failed to read a signal — surfaced rather than guessed |

JSON fields (per row)

| field | meaning |

|---|---|

| kind | bridge \| notifyd \| atc \| fleet-daemon |

| state | running \| stopped \| unknown |

| pid | OS pid when known (omitted otherwise) |

| uptime_ms | ms since start when known |

| connected | daemon-specific connection health (Telegram online / socket+db reachable / heartbeat alive) |

| channel | connection label, e.g. "Telegram (@bot)", "unix socket + sqlite", "tower (every 15m)" |

| last_activity_at | epoch ms of last real activity when known |

| error_count | errors observed this run |

| last_error | most recent error string when known |

| reason | short human explanation of the state (clean-stop vs crash vs never-configured) |

The pid-identity recycle guard

A daemon's heartbeat records both its pid and its process started_at.

Bare liveness (kill(pid, 0)) is not trusted: when a daemon dies and the

OS hands its pid to a different, unrelated process, that pid is alive but is

no longer our daemon. The probe cross-checks process identity — the

heartbeat's started_at against the live process's real OS start time — so a

recycled pid classifies as stopped (reason: `pid … recycled (different

process, crashed)), never a false running`. A dead pid is caught immediately

regardless of how recent the heartbeat looks; a live-but-wedged pid whose beat

went quiet past the 90s staleness window reports stopped with a wedged?

reason.

For notifyd specifically, "connected" requires an actually-bound Unix

socket (a non-blocking connect() that a listener accepts) — not merely a

notify.sock file on disk, which a crashed daemon can leave behind. The DB is

reported as "file present", honestly not "reachable", since exists() does

not prove the sqlite file opens and accepts writes.

Composition patterns

# Any daemon not running?
ainb --format json fleet daemons | jq '[.[] | select(.state != "running")]'

# Is the bridge connected to a chat channel right now?
ainb --format json fleet daemons | jq '.[] | select(.kind=="bridge") | {state, connected, channel, reason}'

# Surface any crash reasons in one line each
ainb --format json fleet daemons | jq -r '.[] | select(.reason | test("crash|stale|wedged")) | "\(.kind): \(.reason)"'

Caveats

reports. To manage a daemon, use its own verb (`ainb fleet bridge

install/uninstall, ainb fleet atc setup/teardown, ainb fleet daemon`).

probe mirrors that so it reads the same files notifyd writes (a set

$AINB_HOME is only honoured for an isolated test run).

instance; the instance name is in the channel label. Heartbeat-disabled

instances are never counted as running, even with a recent leftover beat.

· every 15m or tower · LITE · no LLM`. A lite instance has no scheduler and

no brain session, so it is probed by its scan loop instead; one provisioned in

lite with no scanner running reads degraded (the fleet has a designated

owner and that owner is absent), not stopped.

it is not in, and the screen prints what each mode does inline. It is the same

transition ainb fleet atc mode <name> --set <mode> performs — the screen

shells that verb rather than reimplementing the stop-then-start ordering.

Use this skill with your AI agent: Open on Skill Issue to copy, download, or add to your library. Works with Claude, ChatGPT, Gemini, Cursor, Windsurf and more.