Ics

From PurpleAILAB/Decepticon · View interactive version

Ics is an AI agent skill from the GitHub repository PurpleAILAB/Decepticon. Use when the target is an industrial control system or operational technology network running Modbus, BACnet, S7Comm/S7Comm Plus, DNP3, OPC-UA, or any PLC/HMI/SCADA stack. Engagements MUST set RoE flag industrial_safety_critical=true; this catalog gates every write-scope operation behind explicit op

How to use this skill

Skill file

ICS / OT Operator Skill Catalog

Industrial engagements are not application security with longer rules of

engagement — they are a different discipline. A miswritten Modbus coil

on a real plant kills people. This catalog is read-mostly by default;

every write-scope skill carries an explicit safety gate.

Hard rules

  1. No writes without OPPLAN.safety_critical confirmation. The

middleware refuses writes when the active OPPLAN objective does not

carry safety_critical_confirmed=true. Bypass requires operator

signature in /workspace/safety-attestation.txt.

  1. Read-only protocol discovery first. Identify what's on the wire

before any active probing. Many ICS protocols are unauthenticated;

a single malformed read can crash an old PLC.

  1. Out-of-band physical safety. The blue team includes plant ops.

A ConOps with blue_team.plant_ops_phone is mandatory for engagements

on active production lines.

Playbooks

Inline technique reference — not separately loadable skills. The entries below

are summarized here for direct use; there is no separate SKILL.md to open for

each. Do NOT call the skill loader on them — apply the technique with your tools

using this summary and the protocol assessment guidance in this file.

| Technique | Use for |

|---|---|

| modbus-discovery | Read-only Modbus TCP/RTU enumeration, function code 3/4 polling |

| modbus-write | GATED Write coils / registers; safety gate enforced |

| bacnet-discovery | BACnet/IP Who-Is, object enumeration, device profile |

| s7comm | Siemens S7 / S7Comm Plus enumeration via Snap7 / python-snap7 |

| dnp3 | DNP3 outstation / master discovery; integrity poll |

| opcua | OPC-UA browse, anonymous auth check, certificate analysis |

| hmi-web | HMI web stacks (Wonderware, Iconics, Schneider) — known CVEs |

| engineering-software | TIA Portal / Studio 5000 / Unity Pro project extraction |

Protocol assessment

  1. Passive observation: tap a SPAN port if available. Identify protocols

on the wire (tshark -Y modbus || tshark -Y bacnet || ...).

  1. Network-layer discovery: nmap with -sV --script modbus-discover,

bacnet-info, s7-info, dnp3-info (NSE scripts ship in Kali by

default; some are slow — set -T2 for production networks).

  1. Function-code-3 polling: read holding registers from every Modbus

device discovered. Log register maps to the knowledge graph as

:Service nodes with protocol=modbus.

  1. Identify the safety integrity level (SIL) of any device touched.

SIL 3+ devices NEVER get write probes without plant-ops sign-off.

  1. Engineering software attack path: if you can reach the engineering

workstation, extract the project archive (.s7p, .acd, .stp). The

project file is the crown jewel — it reveals the entire process model.

Detection gap

ICS networks rarely have host-based detection on PLCs/RTUs themselves —

the detection stack lives on the engineering workstation, the historian,

and any IT/OT gateway. Relevant Sigma detection patterns include:

Out of scope by default

Active glitching of PLC firmware; firmware upload to PLCs; safety

controller writes — all of these require an explicit RoE annex signed

by the asset owner. The default ICS RoE template in soundwave/ includes

this annex skeleton.