ICS / OT Operator Skill Catalog
Industrial engagements are not application security with longer rules of
engagement — they are a different discipline. A miswritten Modbus coil
on a real plant kills people. This catalog is read-mostly by default;
every write-scope skill carries an explicit safety gate.
Hard rules
- No writes without OPPLAN.safety_critical confirmation. The
middleware refuses writes when the active OPPLAN objective does not
carry safety_critical_confirmed=true. Bypass requires operator
signature in /workspace/safety-attestation.txt.
- Read-only protocol discovery first. Identify what's on the wire
before any active probing. Many ICS protocols are unauthenticated;
a single malformed read can crash an old PLC.
- Out-of-band physical safety. The blue team includes plant ops.
A ConOps with blue_team.plant_ops_phone is mandatory for engagements
on active production lines.
Playbooks
Inline technique reference — not separately loadable skills. The entries below
are summarized here for direct use; there is no separate
SKILL.mdto open for
each. Do NOT call the skill loader on them — apply the technique with your tools
using this summary and the protocol assessment guidance in this file.
| Technique | Use for |
|---|---|
| modbus-discovery | Read-only Modbus TCP/RTU enumeration, function code 3/4 polling |
| modbus-write | GATED Write coils / registers; safety gate enforced |
| bacnet-discovery | BACnet/IP Who-Is, object enumeration, device profile |
| s7comm | Siemens S7 / S7Comm Plus enumeration via Snap7 / python-snap7 |
| dnp3 | DNP3 outstation / master discovery; integrity poll |
| opcua | OPC-UA browse, anonymous auth check, certificate analysis |
| hmi-web | HMI web stacks (Wonderware, Iconics, Schneider) — known CVEs |
| engineering-software | TIA Portal / Studio 5000 / Unity Pro project extraction |
Protocol assessment
- Passive observation: tap a SPAN port if available. Identify protocols
on the wire (tshark -Y modbus || tshark -Y bacnet || ...).
- Network-layer discovery: nmap with
-sV --script modbus-discover,
bacnet-info, s7-info, dnp3-info (NSE scripts ship in Kali by
default; some are slow — set -T2 for production networks).
- Function-code-3 polling: read holding registers from every Modbus
device discovered. Log register maps to the knowledge graph as
:Service nodes with protocol=modbus.
- Identify the safety integrity level (SIL) of any device touched.
SIL 3+ devices NEVER get write probes without plant-ops sign-off.
- Engineering software attack path: if you can reach the engineering
workstation, extract the project archive (.s7p, .acd, .stp). The
project file is the crown jewel — it reveals the entire process model.
Detection gap
ICS networks rarely have host-based detection on PLCs/RTUs themselves —
the detection stack lives on the engineering workstation, the historian,
and any IT/OT gateway. Relevant Sigma detection patterns include:
- Function-code anomalies (write to coils outside normal ranges).
- Connection sources outside the documented MES/SCADA IP set.
- TIA Portal / Studio 5000 project download events.
Out of scope by default
Active glitching of PLC firmware; firmware upload to PLCs; safety
controller writes — all of these require an explicit RoE annex signed
by the asset owner. The default ICS RoE template in soundwave/ includes
this annex skeleton.