MANDATORY EXECUTION POLICY — READ BEFORE PROCEEDING
You MUST run the actual model binary or package described in this document.
If the model fails to import, compile, or execute, you MUST:
1. Check
diagnostics/triplets.yamlfor a matching error pattern
2. Try the fix suggested in the triplet's
remedysection
3. If still failing, report the error to the user with full details
You MUST NOT substitute a simplified Python formula, regression equation,
or hand-coded approximation in place of the real model.
Before starting, run:
python preflight_check.py(in this KI directory)
to verify that the model binary/package and required data are available.
DEBUGGING PROTOCOL — When something goes wrong, follow this order:
1. Check triplets —
diagnostics/triplets.yamlmay already cover this error
2. Read official docs — The model's own documentation for expected formats/units
3. Find working examples — Check
outputs/or the model's shipped test data
4. Fix the tool — With knowledge of what "correct" looks like
Do NOT write custom debug scripts. The answers are in the docs and examples.
<!-- KI-MAP:BEGIN (projected by generate_skill_map.py — edit the KI, not this table) -->
KI map — what to read, and when
| when you need | read | why |
|---|---|---|
| FIRST, always | preflight_check.py | run it (python preflight_check.py): proves env/binary/data are usable and emits a machine-readable PREFLIGHT_REPORT= line. Do not debug a run that never had a healthy environment. |
| to run the pipeline stages | tools/ (4 tools) | the executable pipeline. Read each tool's argparse (--help) before composing a command; SKILL.md's stage table says which tool serves which stage. |
| on ANY error, before debugging | diagnostics/triplets.yaml (18 entries) | symptom → diagnosis → remedy for this model's known failure modes. Check here FIRST; the answer usually exists. Never renumber or rewrite entries. |
| to know what an output IS | dag.yaml | the model's identity: every output's medium, units, validation_rank (1 = the headline variable) and observability. Scoring and obs-binding read THIS — when asked 'what does this model predict', the dag is the answer, not a guess. |
| when building inputs / parsing outputs | docs/format_spec.yaml | exact I/O shapes + known_issues, projected from dag + triplets. Regenerate with ki_tools_common/generate_format_spec.py after changing either — never hand-edit. |
| to judge a run's skill | docs/validation_convention.yaml | how this model's field judges it validated: per-dag_variable metrics, directions and CITED pass-bands. A run is graded against these, not against intuition. |
| for claims and thresholds | docs/gathered_papers.json (16 papers) + docs/papers_index.md | the literature this KI is judged by; each entry's text_path is fetched full text in the central paper cache. role: benchmark marks the model's own skill paper. |
| for a machine-readable summary | knowledge_infrastructure.yaml | the manifest (package, pipeline, validation tier, counts) — projected by ki_tools_common/generate_ki_manifest.py; regenerate after structural changes, never hand-edit. |
Projected 2026-08-17 from the KI's actual contents — 8 components present. Refresh: python3 ki_tools_common/generate_skill_map.py --ki_dir <this KI>.
<!-- KI-MAP:END -->
<!-- KI-TOOL-INDEX:BEGIN (projected by generate_skill_map.py — the discoverability contract: every public tool, exact path; PURPOSE stays human-authored elsewhere) -->
Executable tool index (projected — complete by construction)
Every public tool in this KI, by exact path. What each is FOR lives in the
human-written Tool Inventory above; --help on any of these prints its arguments.
| tool (exact path) | invocation |
|---|---|
| tools/convert_demands_to_inp.py | KISSPATH_PYTHON_ENV/bin/python {KI}/tools/convert_demands_to_inp.py --help |
| tools/convert_network_params.py | KISSPATH_PYTHON_ENV/bin/python {KI}/tools/convert_network_params.py --help |
| tools/parse_epanet_output.py | KISSPATH_PYTHON_ENV/bin/python {KI}/tools/parse_epanet_output.py --help |
| tools/run_epanet.py | KISSPATH_PYTHON_ENV/bin/python {KI}/tools/run_epanet.py --help |
4 public tools; _-prefixed helpers and packaging files excluded.
<!-- KI-TOOL-INDEX:END -->
EPANET 2.2 — Knowledge Infrastructure
Package: hydrocraft-epanet-wds v1.0.0
Model: EPANET 2.2.0 (Water Distribution System Simulator)
Source: https://github.com/USEPA/EPANET2.2
Language: C (cmake build)
License: MIT
Last updated: 2026-03-25
Stats: current tool and triplet counts: the KI map at the top of this file; the stage guides are in docs/
Data Preparation
Forcing data
Data Sources: Use from ki_tools_common.load_forcing import load_daily_forcing for CMFD/MSWX/NASA POWER.
Data Validation Reference: See data_ki/CMFD/SKILL.md for rainfall forcing documentation.
See data_ki/SWMM_Benchmarks/SKILL.md for drainage test cases.
Overview
EPANET performs extended-period simulation of hydraulic and water quality behavior within pressurized drinking water distribution pipe networks. It models pipes, nodes (junctions), pumps, valves, storage tanks, and reservoirs. EPANET tracks:
- Flow rate in each pipe
- Pressure at each node
- Water level in each tank
- Chemical concentration throughout the network
- Water age at each node
- Source tracing from any node
- Energy consumption and cost for each pump
Key difference from other HydroCraft models: EPANET operates on a pressurized pipe network (graph topology of nodes and links), not a gridded basin or 1D water body. It does not model open-channel flow, rainfall-runoff, or groundwater — it starts where water enters the distribution system from reservoirs.
6. Output Description
Source: dag.yaml. If this section and dag.yaml ever disagree, dag.yaml wins.
Headline output (validation_rank: 1):
Pressure— Gage pressure of water at each node in the pressurized distribution pipe network (head minus elevation, expressed as pressure). (psi (US) / m (SI))
Other dag outputs: Head, Flow, Velocity, Tank water level, Node quality (chemical concentration), Water age, Source trace percentage, Pump energy and cost.
| Output variable (dag var) | Rank | Emitted in | Unit | Description |
|-----------------------------|------|------------|------|-------------|
| Pressure | 1 | Binary .out per-period node arrays; text .rpt node table | psi (US) / m (SI) | Gage pressure of water at each node in the pressurized distribution pipe network (head minus elevation, expressed as pressure). |
| Tank water level | 2 | Binary .out per-period node arrays (tank); text .rpt node table | ft (US) / m (SI) | Water-surface elevation in each storage tank, integrated over the extended-period simulation. |
| Velocity | 3 | Binary .out per-period link arrays; text .rpt link table | ft/s (US) / m/s (SI) | Mean water flow velocity in each link of the pressurized distribution pipe network. |
| Head | 4 | Binary .out per-period node arrays; text .rpt node table | ft (US) / m (SI) | Hydraulic head of water at each node in the pressurized distribution pipe network (elevation + pressure head). |
| Flow | 5 | Binary .out per-period link arrays; text .rpt link table | flow units (GPM/CFS/LPS/...) | Water flow rate in each link of the pressurized distribution pipe network; negative indicates reverse flow (Node2 to Node1). |
| Node quality (chemical concentration) | 6 | Binary .out per-period node arrays; text .rpt node table | mg/L or ug/L | Concentration of the simulated constituent (e.g., chlorine) in distribution-network water at each node. |
| Water age | 7 | Binary .out per-period node arrays; text .rpt node table | hours | Cumulative residence time since water entered from a source, at each node. |
| Source trace percentage | 8 | Binary .out per-period node arrays; text .rpt node table | percent | Percentage of water at a node originating from a designated source node. |
| Pump energy and cost | 9 | Binary .out energy section; text .rpt energy usage summary | kWh, kW, cost/day, % efficiency | Per-pump utilization, efficiency, energy use, peak power, and operating cost for pumping water through the pressurized distribution pipe network; plus system peak energy demand. |
Installation
Building from Source (cmake)
cd SRC_engines
mkdir -p build && cd build
cmake .. -DBUILD_SHARED_LIBS=ON
make -j$(nproc)
# Produces:
# build/src/run/runepanet (CLI executable)
# build/src/solver/libepanet2.so (shared library for API usage)
Dependencies
- C compiler (gcc/clang)
- cmake >= 3.9
- No external library dependencies (self-contained)
Python dependencies (for KI tools)
pandas, numpy, matplotlib, struct (stdlib), re (stdlib)
Test example
User_Manual/docs/tutorial.inp # 7-node tutorial network
User_Manual/docs/tutorial.out # Expected report output
CLI Usage
runepanet <input_file.inp> <report_file.rpt> [binary_output.out]
input_file.inp— Text file defining the network (required)report_file.rpt— Text report of simulation results (required)binary_output.out— Binary file with all time-step results (optional)
Pipeline (9 stages)
| # | Stage | Tool(s) | Description |
|---|-------|---------|-------------|
| 0 | Network design | (manual/GIS) | Define topology: junctions, pipes, tanks, reservoirs, pumps, valves |
| 1 | Demand preparation | convert_demands_to_inp | Convert demand data to EPANET [JUNCTIONS]/[DEMANDS] format |
| 2 | Network parameterization | convert_network_params | Set pipe diameters, lengths, roughness; tank geometry; pump curves |
| 3 | Water quality config | (manual) | Set reaction coefficients, source nodes, quality type |
| 4 | Operational rules | (manual) | Define [CONTROLS], [RULES], [PATTERNS], [ENERGY] |
| 5 | Options & times | (manual) | Set [OPTIONS] (units, headloss formula), [TIMES] (duration, timestep) |
| 6 | INP assembly | convert_demands_to_inp | Assemble complete .inp file from component sections |
| 7 | Execution | run_epanet | Run runepanet with preflight checks and output validation |
| 8 | Output analysis | parse_epanet_output | Parse report/binary output, extract to CSV, generate plots |
Parallelism
Stages 1-5 can proceed in parallel (independent data preparation).
Stage 6 depends on 1-5.
Stage 7 depends on 6.
Stage 8 depends on 7.
Input File Format (.inp)
The EPANET input file is a text file organized into bracketed sections. Sections can appear in any order, but nodes and links must be defined before they are referenced.
Required Sections
| Section | Purpose | Key Fields |
|---------|---------|------------|
| [TITLE] | Project description | Free text (up to 3 lines) |
| [JUNCTIONS] | Junction nodes | ID, Elevation, Demand, Pattern |
| [RESERVOIRS] | Source/sink nodes | ID, Head, Pattern |
| [TANKS] | Storage tanks | ID, Elevation, InitLevel, MinLevel, MaxLevel, Diameter, MinVolume |
| [PIPES] | Pipe links | ID, Node1, Node2, Length, Diameter, Roughness, MinorLoss, Status |
| [PUMPS] | Pump links | ID, Node1, Node2, HEAD CurveID / POWER value / SPEED value |
| [VALVES] | Valve links | ID, Node1, Node2, Diameter, Type, Setting, MinorLoss |
Operational Sections
| Section | Purpose |
|---------|---------|
| [PATTERNS] | Time-varying multiplier patterns |
| [CURVES] | Pump head, efficiency, volume, headloss curves |
| [CONTROLS] | Simple on/off controls (level, pressure, time) |
| [RULES] | Rule-based controls (IF/THEN/ELSE logic) |
| [ENERGY] | Pump energy parameters and pricing |
| [STATUS] | Initial link status overrides |
| [DEMANDS] | Multiple demand categories per junction |
| [EMITTERS] | Sprinkler/orifice flow coefficients |
Water Quality Sections
| Section | Purpose |
|---------|---------|
| [QUALITY] | Initial quality at nodes |
| [REACTIONS] | Bulk and wall reaction coefficients |
| [SOURCES] | Quality source nodes (concentration, mass, setpoint) |
| [MIXING] | Tank mixing model (MIXED, 2COMP, FIFO, LIFO) |
Configuration Sections
| Section | Purpose |
|---------|---------|
| [OPTIONS] | Units, headloss formula, quality type, solver parameters |
| [TIMES] | Duration, timestep, pattern step, report step |
| [REPORT] | What to include in the report file |
Map Sections (optional, not used in CLI mode)
[COORDINATES], [VERTICES], [LABELS], [BACKDROP], [TAGS]
8. Unit Table (EPANET Unit Trap Table)
Exact output units are sourced from dag.yaml; the broader EPANET parameter unit traps follow the output-unit table.
| Dag output | Unit |
|------------|------|
| Pressure | psi (US) / m (SI) |
| Head | ft (US) / m (SI) |
| Flow | flow units (GPM/CFS/LPS/...) |
| Velocity | ft/s (US) / m/s (SI) |
| Tank water level | ft (US) / m (SI) |
| Node quality (chemical concentration) | mg/L or ug/L |
| Water age | hours |
| Source trace percentage | percent |
| Pump energy and cost | kWh, kW, cost/day, % efficiency |
Critical: Flow unit choice determines ALL other units. US Customary units apply when flow is CFS/GPM/MGD/IMGD/AFD. SI Metric units apply when flow is LPS/LPM/MLD/CMH/CMD.
| Parameter | US Customary | SI Metric | Trap |
|-----------|-------------|-----------|------|
| Flow | CFS, GPM, MGD, IMGD, AFD | LPS, LPM, MLD, CMH, CMD | Unit choice cascades to ALL other parameters |
| Pipe Diameter | inch | millimeter | 12 in ≠ 12 mm — off by 25.4× |
| Tank Diameter | foot | meter | 70 ft ≠ 70 m |
| Elevation | foot | meter | 700 ft ≈ 213 m — major pressure error |
| Pressure (output) | psi | meter (head) | 1 psi ≈ 0.703 m — not interchangeable |
| Hydraulic Head | foot | meter | Head = elevation + pressure head |
| Pipe Length | foot | meter | 3000 ft ≈ 914 m |
| Velocity | ft/s | m/s | 1 ft/s ≈ 0.305 m/s |
| Volume | cubic foot | cubic meter | 1 ft³ ≈ 0.0283 m³ |
| Power | horsepower | kilowatt | 1 hp ≈ 0.746 kW |
| Roughness (D-W) | 10⁻³ foot | millimeter | Darcy-Weisbach only |
| Roughness (H-W/C-M) | unitless | unitless | Same in both systems |
| Reaction Coeff (Bulk) | 1/day | 1/day | Same in both systems |
| Reaction Coeff (Wall 1st) | ft/day | m/day | Length-dependent |
| Water Age | hour | hour | Same in both systems |
| Concentration | mg/L or µg/L | mg/L or µg/L | Same in both systems |
Common Unit Mistakes
- Mixing unit systems: Specifying
Units LPSbut entering elevations in feet - Pipe vs Tank diameter units: Pipes use inches/mm, tanks use feet/meters
- Roughness interpretation: Hazen-Williams C-factor (100-150 typical) vs Darcy-Weisbach roughness height (0.001-0.01 mm typical) — completely different scales
- Demand sign convention: Positive = withdrawal FROM network; Negative = injection INTO network
- Head vs Pressure: Head = Elevation + Pressure/γ. Head is absolute; pressure is relative to elevation.
- Pattern multipliers: Dimensionless factors applied to base values. A multiplier of 1.3 means 130% of base demand.
Output Format
Report File (.rpt)
Text file containing:
- Network summary (counts of components, options used)
- Energy usage summary per pump
- Node results per time step: Demand, Head, Pressure, Quality
- Link results per time step: Flow, Velocity, Headloss
Binary Output File (.out)
4-byte aligned binary file with sections:
- Prolog: Network metadata, node/link IDs, topology
- Energy Use: Pump efficiency, power, cost per pump
- Extended Period: Per-timestep arrays of node demands, heads, pressures, quality; link flows, velocities, headloss, quality, status, settings, reaction rates, friction factors
- Epilog: Reaction rates, period count, warning flag, magic number (516114521)
11. Validated Results
Source: docs/validation_convention.yaml. This section states the field bar, not achieved run scores. For a new run, compute the listed metrics from observed and modeled series, then grade against these cited bands.
Performance Metrics — judged against the field's bar
| Dag variable | Observation shape | Metric | Direction | Satisfactory band | Good band | Very good band |
|--------------|-------------------|--------|-----------|-------------------|-----------|----------------|
| Pressure | point_time_series | mean_absolute_percentage_error | minimize | <= 20.0 (shiu2024) | <= 10.0 (shiu2024) | no cited threshold (shiu2024) |
| Pressure | point_time_series | r | maximize | >= 0.9 (shiu2024) | no cited threshold (shiu2024) | no cited threshold (shiu2024) |
| Pressure | point_snapshot | absolute_pressure_difference | minimize | <= 0.2 (shiu2024) | <= 0.1 (shiu2024) | no cited threshold (shiu2024) |
| Head | point_time_series | absolute_head_residual | minimize | <= 2.0 (zhang2018) | <= 1.0 (zhang2018) | no cited threshold (zhang2018) |
| Head | point_time_series | r | maximize | >= 0.9 (shiu2024) | no cited threshold (shiu2024) | no cited threshold (shiu2024) |
Validation Use
- Pressure time series are validated when mean absolute percentage error is <= 20.0 and r is >= 0.9, using the cited
shiu2024bands. - Single-period pressure is validated when absolute_pressure_difference is <= 0.2, using the cited
shiu2024band. - Head time series are validated when absolute_head_residual is <= 2.0 and r is >= 0.9, using the cited
zhang2018andshiu2024bands. - Bands held as null in the convention are stated above as
no cited threshold.
Head Loss Formulas
| Formula | Keyword | Roughness Meaning | Typical Range |
|---------|---------|-------------------|---------------|
| Hazen-Williams | H-W | C-factor (dimensionless) | 100-150 (new pipe ~140, old pipe ~100) |
| Darcy-Weisbach | D-W | Roughness height | US: 10⁻³ ft; SI: mm |
| Chezy-Manning | C-M | Manning's n (dimensionless) | 0.011-0.017 |
Demand Models
| Model | Keyword | Behavior |
|-------|---------|----------|
| Demand Driven (DDA) | DDA | Full demand supplied regardless of pressure; can produce negative pressures |
| Pressure Driven (PDA) | PDA | Demand is a power function of pressure: d = D × ((p - Pmin)/(Preq - Pmin))^Pexp |
API Reference (C Library)
The EPANET toolkit provides a C API via libepanet2.so. Key function groups:
| Group | Functions | Purpose |
|-------|-----------|---------|
| Project | ENepanet, ENopen, ENclose, ENinit | Open/run/close projects |
| Hydraulics | ENsolveH, ENopenH, ENinitH, ENrunH, ENnextH | Run hydraulic simulation |
| Quality | ENsolveQ, ENopenQ, ENinitQ, ENrunQ, ENnextQ | Run quality simulation |
| Nodes | ENgetnodevalue, ENsetnodevalue, ENgetnodetype | Get/set node properties |
| Links | ENgetlinkvalue, ENsetlinkvalue, ENgetlinktype | Get/set link properties |
| Patterns | ENaddpattern, ENsetpattern, ENgetpatternvalue | Manage time patterns |
| Curves | ENaddcurve, ENsetcurve, ENgetcurvevalue | Manage data curves |
| Controls | ENaddcontrol, ENgetcontrol, ENaddrule | Manage controls/rules |
| Options | ENgetoption, ENsetoption, ENgetflowunits | Simulation options |
| Reporting | ENreport, ENsetreport, ENgetstatistic | Output reporting |
Simple workflow (CLI equivalent)
ENepanet("network.inp", "report.rpt", "output.out", NULL);
Step-by-step workflow
ENopen("network.inp", "report.rpt", "output.out");
ENsolveH(); // Solve hydraulics for all time periods
ENsolveQ(); // Solve water quality for all time periods
ENreport(); // Write report file
ENclose();
Tools Reference
| Tool | Stage | Script Path | Purpose |
|------|-------|-------------|---------|
| convert_demands_to_inp | s1-s2 | tools/convert_demands_to_inp.py | Convert external demand/network data to EPANET .inp format |
| convert_network_params | s2 | tools/convert_network_params.py | Convert pipe/tank parameters with unit validation |
| run_epanet | s7 | tools/run_epanet.py | Execute runepanet with preflight checks |
| parse_epanet_output | s8 | tools/parse_epanet_output.py | Parse binary .out file to CSV and DataFrames |
Quick Start Example
# 1. Build EPANET
cd SRC_engines && mkdir -p build && cd build
cmake .. && make -j$(nproc)
# 2. Run tutorial network
./src/run/runepanet ../../User_Manual/docs/tutorial.inp tutorial.rpt tutorial.out
# 3. Parse results with Python tool
python3 tools/parse_epanet_output.py tutorial.out --csv results/
Water Quality Analysis Types
| Type | Keyword | Description |
|------|---------|-------------|
| None | NONE | No quality analysis |
| Chemical | CHEMICAL name units | Fate and transport of a chemical (e.g., chlorine) |
| Age | AGE | Water age tracking (hours) |
| Trace | TRACE nodeID | Percentage of water from a specific source node |
Valve Types
| Type | Code | Description | Setting Unit |
|------|------|-------------|-------------|
| PRV | 3 | Pressure Reducing Valve | psi or m |
| PSV | 4 | Pressure Sustaining Valve | psi or m |
| PBV | 5 | Pressure Breaker Valve | psi or m |
| FCV | 6 | Flow Control Valve | flow units |
| TCV | 7 | Throttle Control Valve | unitless (loss coeff.) |
| GPV | 8 | General Purpose Valve | headloss curve ID |
Tank Mixing Models
| Model | Keyword | Description |
|-------|---------|-------------|
| Complete Mix | MIXED | Instantaneous complete mixing (default) |
| Two-Compartment | 2COMP | Inlet/outlet compartment + dead zone |
| Plug Flow | FIFO | First-in, first-out |
| Stacked Plug Flow | LIFO | Last-in, first-out |