Xcms preprocessing

From GPTomics/bioSkills · View interactive version

Xcms preprocessing is an AI agent skill from the GitHub repository GPTomics/bioSkills. Programmatic untargeted LC-MS feature extraction in R with the modern xcms 4.x MsExperiment/XcmsExperiment API, taking raw mzML to a feature table via CentWave peak detection, retention-time alignment, peak-density correspondence, gap-filling, CAMERA redundancy collapse, and built-in QC feature filt

How to use this skill

Skill file

Version Compatibility

Reference examples tested with: xcms 4.x+ (MsExperiment/XcmsExperiment containers), Spectra 1.12+, CAMERA 1.58+

Before using code patterns, verify installed versions match. If versions differ:

If code throws ImportError, AttributeError, or TypeError, introspect the installed

package and adapt the example to match the actual API rather than retrying.

A feature table is only meaningful alongside its full processing specification: which xcms version, every *Param value, and the fill/filter ordering. The table is a parameterized hypothesis about which molecules exist, not the data.

XCMS Untargeted LC-MS Preprocessing

"Turn my raw LC-MS files into a feature table" -> Detect chromatographic peaks per file, align retention times across runs, group corresponding peaks into features, fill gaps, then collapse adduct/isotope redundancy.

The Single Most Important Insight -- The Feature Table Is a Model-Dependent Artifact, Not Ground Truth

Every cell in the table is the output of a detection + grouping + filling model with chosen parameters. Two analysts with different centWave/grouping settings produce materially different tables from identical raw files, so "not detected" is a statement about the parameters, not the sample. Three consequences reorganize the whole workflow: (1) preprocessing parameters silently set the detection floor - a compound absent from results may be present in the raw data but excluded by noise/prefilter/peakwidth/snthresh; (2) fillChromPeaks integrates whatever signal sits in a feature window even when no peak exists, fabricating a positive number where the honest answer is "below detection"; (3) one compound yields 5-15 features (adducts, isotopologues, in-source fragments, multimers), so a 10,000-feature table is plausibly ~1,000 compounds (Mahieu 2017). Report parameters as part of the result, inspect EICs and alignment of every hit, and collapse redundancy before annotation.

API Generations -- Use Modern, Not Legacy

| Path | Containers | Verbs | Status |

|------|-----------|-------|--------|

| Modern (xcms 4.x) | MsExperiment (raw, Spectra backend) / XcmsExperiment (result) | findChromPeaks / adjustRtime / groupChromPeaks / fillChromPeaks driven by *Param objects | Preferred |

| Legacy (xcms <3) | xcmsSet / xcmsRaw | findPeaks / group / retcor / fillPeaks; readMSData(mode='onDisk') | Deprecated - do not use in new code |

Parameters are objects, not loose args: findChromPeaks(data, param = CentWaveParam(...)), never findChromPeaks(data, ppm=..., peakwidth=...).

Decision Tree by Scenario

| Situation | Do | Why |

|-----------|----|----|

| High-res centroid (Orbitrap, Q-Exactive, qTOF) | CentWaveParam | Wavelet on real mass traces, no fixed binning |

| Low-res / quadrupole / profile-only | MatchedFilterParam | Model-peak on binned EICs tolerates poor resolution |

| Profile data of any kind | Centroid first (msconvert vendor peakPicking, or Spectra::pickPeaks) | centWave requires centroids; profile input yields garbage mass traces |

| Many shared, well-behaved peaks across samples | PeakGroupsParam (after an initial groupChromPeaks) | Loess on universal anchor peaks; gentle and fast |

| Few shared peaks / sparse / strong nonlinear drift | ObiwarpParam | Full-profile warping needs no prior peaks |

| Cohort with large case/control compositional differences | ObiwarpParam, or PeakGroupsParam with subset = QC indices | Few universal anchors mis-register the condition-specific metabolome |

| New instrument, no parameter priors | AutoTuner / IPO for a starting neighborhood, then verify against EIC FWHM | Optimizers maximize a surrogate, not biology (McLean 2020) |

| GC-EI data | Deconvolution tools, not xcms peak picking -> metabolomics/msdial-preprocessing | Co-elution + universal fragmentation require component separation first |

Peak Detection

Goal: Detect chromatographic peaks in each centroided file.

Approach: Build a CentWaveParam with ppm and peakwidth set from the actual instrument and chromatography (see Quantitative Thresholds), then call findChromPeaks.

library(xcms)
# spectraFiles: centroided mzML paths; pd: data.frame with one row per file
raw <- readMsExperiment(spectraFiles = mzml_files, sampleData = pd)

# ppm is across-scan centroid scatter (~2-3x measured error), NOT the spec mass accuracy.
# peakwidth is c(min, max) in SECONDS, measured from EIC base-widths of known peaks.
cwp <- CentWaveParam(ppm = 10, peakwidth = c(2, 20), snthresh = 10,
                     prefilter = c(3, 1000), noise = 1000, mzdiff = -0.001,
                     integrate = 1L, mzCenterFun = 'wMean')
xdata <- findChromPeaks(raw, param = cwp)
nrow(chromPeaks(xdata))

Retention-Time Alignment

Goal: Remove cross-run RT drift so the same compound lands at the same RT in every sample.

Approach: Choose obiwarp (no prior peaks) or peakGroups (anchor-based); align to a pooled QC, never to file #1. Regroup afterward because RTs changed.

# obiwarp: full-profile warping. binSize here is the m/z profile bin (default 1),
# distinct from PeakDensityParam$binSize and MatchedFilterParam$binSize.
xdata <- adjustRtime(xdata, param = ObiwarpParam(binSize = 0.6))

# peakGroups alternative needs an initial correspondence and good universal anchors:
# xdata <- groupChromPeaks(xdata, param = pdp_anchor)
# xdata <- adjustRtime(xdata, param = PeakGroupsParam(minFraction = 0.85, span = 0.4,
#     subset = which(sampleData(xdata)$sample_type == 'QC'), subsetAdjust = 'average'))
plotAdjustedRtime(xdata)

Correspondence (Grouping)

Goal: Match peaks across samples into consensus features.

Approach: Peak-density grouping in m/z slices; bw is the dominant knob and must reflect residual post-alignment RT scatter, not raw peak width.

pdp <- PeakDensityParam(sampleGroups = sampleData(xdata)$sample_group,
                        bw = 5, minFraction = 0.5, minSamples = 1, binSize = 0.025)
xdata <- groupChromPeaks(xdata, param = pdp)
nrow(featureDefinitions(xdata))

Gap-Filling

Goal: Integrate signal for features missing a detected peak in some samples.

Approach: fillChromPeaks with ChromPeakAreaParam; treat filled values as imputations, not measurements.

xdata <- fillChromPeaks(xdata, param = ChromPeakAreaParam())
filled <- chromPeakData(xdata)$is_filled   # logical flag; lives in chromPeakData, not chromPeaks
feat <- featureValues(xdata, value = 'into')        # features x samples matrix
defs <- featureDefinitions(xdata)                   # mzmed / rtmed / npeaks per feature

Redundancy Collapse

Goal: Group the same compound's adducts/isotopes/fragments back toward compound spectra before annotation.

Approach: CAMERA in order groupFWHM -> groupCorr -> findIsotopes -> findAdducts (isotopes before adducts). Correlation grouping needs enough samples to be meaningful and can over- or under-merge - verify against the table size.

library(CAMERA)
xsa <- xsAnnotate(as(xdata, 'xcmsSet'))
xsa <- groupFWHM(xsa, perfwhm = 0.6)
xsa <- groupCorr(xsa)
xsa <- findIsotopes(xsa, mzabs = 0.01, ppm = 10)
xsa <- findAdducts(xsa, polarity = 'positive')
peaklist <- getPeaklist(xsa)

QC Feature Filtering (Preprocessing/QC Bridge)

Goal: Drop features that fail conventional QC, operationalizing Broadhurst 2018 inside the xcms object.

Approach: filterFeatures with RsdFilter (CV in QCs), DratioFilter (sd_QC/sd_sample), PercentMissingFilter, BlankFlag. Drift correction and the full QC pipeline live in metabolomics/normalization-qc.

qc <- sampleData(xdata)$sample_group == 'QC'
study <- sampleData(xdata)$sample_group %in% c('Control', 'Treatment')
xdata <- filterFeatures(xdata, filter = RsdFilter(threshold = 0.3, qcIndex = qc))
xdata <- filterFeatures(xdata, filter = DratioFilter(threshold = 0.5, qcIndex = qc, studyIndex = study))

Per-Method Failure Modes

ppm set to the spec sheet

peakwidth mismatch

prefilter/noise/snthresh as the trace guillotine

bw too coarse / alignment-coupled

gap-filling fabricates intensities

skipping redundancy collapse

Quantitative Thresholds

| Threshold | Source | Rationale |

|-----------|--------|-----------|

| ppm Orbitrap/Q-Exactive 5-10, qTOF 15-30 | Tautenhahn 2008; instrument physics | ~2-3x measured across-scan centroid scatter, not spec accuracy |

| peakwidth UHPLC c(2,20), HPLC c(10,40), HILIC c(10,60) (s) | Smith 2006; chromatography | Must bracket measured EIC base-widths; default c(20,50) wrong for UHPLC |

| Points across peak >= ~6-7 | Zeng 2023 JASMS 34:1136 | Below this, peak-area precision degrades non-linearly; an acquisition limit no parameter recovers |

| prefilter = c(3, I) | Tautenhahn 2008 | Min 3 consecutive scans above intensity I; I set per instrument baseline |

| Grouping bw 2-6 s (UHPLC) | xcms vignette | Default 30 s merges resolved co-eluting compounds on fast chromatography |

| QC CV (RSD) < 0.20-0.30 | Broadhurst 2018 Metabolomics 14:72 | Features with high QC variance are unreliable |

| D-ratio < 0.5 | Broadhurst 2018 | Technical variance must sit well below biological |

| Blank flag k ~ 3-5 | Broadhurst 2018 | Test-sample mean must exceed k x blank mean |

| ~1 compound per 5-15 features | Mahieu 2017 Anal Chem 89:10397 | ~90% of detected features are adduct/isotope/fragment degeneracy |

Common Errors

| Error / symptom | Cause | Solution |

|-----------------|-------|----------|

| could not find function "readMSData" or legacy verbs missing | Using deprecated xcmsSet/readMSData API on xcms 4.x | Use readMsExperiment() + the findChromPeaks/groupChromPeaks verbs |

| unused argument (ppm = ...) in findChromPeaks | Passing loose args instead of a *Param object | Wrap in CentWaveParam(...) and pass via param = |

| Features defined on uncorrected RT | Skipped the regroup after adjustRtime | Call groupChromPeaks again after alignment |

| Garbage mass traces, almost no peaks | Profile (non-centroid) data fed to centWave | Centroid first (msconvert vendor peakPicking or Spectra::pickPeaks) |

| sampleGroups length/semantics error | Vector misaligned with sample order or missing | Pass sampleData(xdata)$group matching file order; it is mandatory |

| Three different binSize defaults confused | obiwarp (m/z, default 1) vs PeakDensity (m/z, 0.25) vs matchedFilter (m/z, 0.1) | Set each in its own *Param; they are not the same knob |

| as(xdata, 'xcmsSet') fails or warns | CAMERA expects the legacy container | Coerce the XcmsExperiment to xcmsSet only for CAMERA; keep modern objects upstream |

References

Related Skills

Use this skill with your AI agent: Open on Skill Issue to copy, download, or add to your library. Works with Claude, ChatGPT, Gemini, Cursor, Windsurf and more.