IMU Driver Configuration for ROS 2

The sensor_msgs/Imu Message

Header header
geometry_msgs/Quaternion orientation          # (x, y, z, w)
float64[9] orientation_covariance             # row-major 3x3

geometry_msgs/Vector3 angular_velocity        # rad/s
float64[9] angular_velocity_covariance

geometry_msgs/Vector3 linear_acceleration     # m/s²
float64[9] linear_acceleration_covariance

Conventions (REP 103/145):

Raw IMU Data from MCU

If using a custom serial protocol (not micro-ROS), the MCU sends raw accelerometer and gyroscope readings. The ROS 2 node converts them:

def unpack_imu_data(payload: bytes) -> Imu:
    ax, ay, az, gx, gy, gz = struct.unpack('<hhhhhh', payload)
    
    msg = Imu()
    msg.header.stamp = node.get_clock().now().to_msg()
    msg.header.frame_id = 'imu_link'
    
    # Accelerometer: convert from raw counts to m/s²
    # MPU6050 at ±2g: sensitivity = 16384 LSB/g
    ACCEL_SCALE = 9.80665 / 16384.0
    msg.linear_acceleration.x = ax * ACCEL_SCALE
    msg.linear_acceleration.y = ay * ACCEL_SCALE
    msg.linear_acceleration.z = az * ACCEL_SCALE
    
    # Gyroscope: convert from raw counts to rad/s
    # MPU6050 at ±250°/s: sensitivity = 131 LSB/(°/s)
    GYRO_SCALE = (1.0 / 131.0) * (math.pi / 180.0)
    msg.angular_velocity.x = gx * GYRO_SCALE
    msg.angular_velocity.y = gy * GYRO_SCALE
    msg.angular_velocity.z = gz * GYRO_SCALE
    
    # No orientation from raw data—set covariance[0] = -1
    msg.orientation_covariance[0] = -1.0
    
    return msg

Static Covariance Configuration

Set covariance based on the IMU's datasheet noise specifications:

# MPU6050 typical noise densities:
# Accelerometer: 400 μg/√Hz at 1 kHz bandwidth → σ² ≈ (400e-6 * 9.81)² * bandwidth
# Gyroscope: 0.005 °/s/√Hz → σ² ≈ (0.005 * π/180)² * bandwidth

accel_variance = 0.01      # m/s², conservative estimate
gyro_variance = 0.001      # rad/s, conservative estimate
orient_variance = 0.05     # rad, from filter output

msg.linear_acceleration_covariance = [
    accel_variance, 0.0, 0.0,
    0.0, accel_variance, 0.0,
    0.0, 0.0, accel_variance,
]

msg.angular_velocity_covariance = [
    gyro_variance, 0.0, 0.0,
    0.0, gyro_variance, 0.0,
    0.0, 0.0, gyro_variance,
]

IMU Filter Packages

Raw accelerometer and gyroscope data do not provide orientation. A filter fuses them (and optionally magnetometer) to estimate orientation.

imu_filter_madgwick

The most widely used ROS 2 IMU filter. Implements Madgwick's gradient-descent AHRS algorithm.

# imu_filter_madgwick params
imu_filter_madgwick_node:
  ros__parameters:
    use_mag: false              # true if magnetometer available and calibrated
    publish_tf: false           # set true if no other node publishes imu transform
    world_frame: "enu"          # ENU (east-north-up) per REP 103
    fixed_frame: "odom"
    gain: 0.1                   # filter gain (higher = faster convergence, more noise)
    zeta: 0.0                   # gyro drift compensation (0 = disabled)
    frequency: 100.0            # expected IMU data rate in Hz
    
    # Remappings (set in launch file)
    # /imu/data_raw → raw accel + gyro
    # /imu/mag → magnetometer (if use_mag)
    # /imu/data → output with orientation

Launch file:

Node(
    package='imu_filter_madgwick',
    executable='imu_filter_madgwick_node',
    name='imu_filter',
    parameters=[imu_filter_params],
    remappings=[
        ('/imu/data_raw', '/imu/data_raw'),
        ('/imu/data', '/imu/data'),
    ],
)

imu_complementary_filter

Simpler filter, works well for many applications:

complementary_filter_gain_node:
  ros__parameters:
    do_bias_estimation: true
    bias_alpha: 0.01
    do_adaptive_gain: true
    gain_acc: 0.01
    gain_mag: 0.01              # only if use_mag
    use_mag: false
    publish_tf: false
    fixed_frame: "odom"

Gyro Bias Calibration

Gyroscope readings drift over time. At startup, the robot must be stationary for bias estimation:

// MCU-side: average 500 readings at startup
int32_t gx_sum = 0, gy_sum = 0, gz_sum = 0;
for (int i = 0; i < 500; i++) {
    readIMU(accel, gyro);
    gx_sum += gyro[0];
    gy_sum += gyro[1];
    gz_sum += gyro[2];
    delay(2);
}
int16_t gx_bias = gx_sum / 500;
int16_t gy_bias = gy_sum / 500;
int16_t gz_bias = gz_sum / 500;

Subtract the bias from all subsequent readings. Some filters (Madgwick with zeta > 0, complementary with do_bias_estimation) estimate bias online, but a startup calibration gives a better initial value.

Magnetometer Calibration

If using a magnetometer for absolute heading (yaw), it must be calibrated for:

Hard Iron Distortion

Constant magnetic field offsets from nearby ferromagnetic materials (motors, steel frames, batteries). Corrected by subtracting an offset vector:

$$

\vec{m}_{\text{cal}} = \vec{m}_{\text{raw}} - \vec{b}_{\text{hard}}

$$

Soft Iron Distortion

Non-uniform scaling caused by nearby metals that distort the field shape. Corrected by a 3x3 matrix multiplication:

$$

\vec{m}_{\text{cal}} = A \cdot (\vec{m}_{\text{raw}} - \vec{b}_{\text{hard}})

$$

Calibration Procedure

  1. Use rosrun imu_tools magnetometer_calibration or the MotionCal tool
  2. Rotate the robot slowly in all orientations (figure-8 pattern)
  3. Collect data for 60+ seconds, covering all orientations
  4. The tool outputs hard-iron offsets ($\vec{b}$) and soft-iron matrix ($A$)
  5. Apply corrections either on the MCU or in the ROS driver

Frame Alignment

The IMU's physical mounting orientation must match ROS conventions. If the IMU is mounted with its X-axis pointing backward:

# In URDF: static transform from base_link to imu_link
<joint name="imu_joint" type="fixed">
  <parent link="base_link"/>
  <child link="imu_link"/>
  <origin xyz="0.0 0.0 0.1" rpy="0 0 3.14159"/>  # rotated 180° yaw
</joint>

Alternatively, apply a rotation in the driver node to remap axes before publishing.

EKF Integration

The filtered IMU data feeds into robot_localization's EKF:

# ekf.yaml
ekf_filter_node:
  ros__parameters:
    imu0: /imu/data
    imu0_config: [false, false, false,     # x, y, z position: ignore
                  true,  true,  true,      # roll, pitch, yaw: use
                  false, false, false,     # vx, vy, vz: ignore
                  true,  true,  true,      # vroll, vpitch, vyaw: use
                  true,  true,  true]      # ax, ay, az: use (optional)
    imu0_differential: false
    imu0_remove_gravitational_acceleration: true
    imu0_queue_size: 10

Key: imu0_remove_gravitational_acceleration: true tells the EKF to subtract gravity from the accelerometer readings before integrating for velocity. Without this, the robot thinks it's constantly accelerating upward at 9.81 m/s².

Troubleshooting

| Symptom | Cause | Fix |

|---------|-------|-----|

| Orientation drifts in yaw | No magnetometer and no yaw constraint | Use use_mag: true with calibrated mag, or fuse with wheel odometry via EKF |

| Roll/pitch offset at rest | IMU not level or axis misalignment | Check URDF transform, verify IMU mounting |

| Noisy angular velocity | Vibration coupling from motors | Mount IMU on vibration dampeners (rubber standoffs), increase filter gain |

| Filter diverges at startup | Large initial bias | Ensure robot is stationary for first 2 seconds, enable bias estimation |

| Heading jumps near motors | Magnetic interference | Move IMU away from motors/batteries, recalibrate magnetometer on the robot |