Interpret ir spectrum

From pjt222/agent-almanac · View interactive version

Interpret ir spectrum is an AI agent skill from the GitHub repository pjt222/agent-almanac. Systematically interpret infrared spectra to identify functional groups present in a sample. Covers diagnostic region analysis (4000-1500 cm-1), fingerprint region assessment (1500-400 cm-1), hydrogen bonding effects, and compilation of a functional group inventory with confidence levels.

How to use this skill

Skill file

Interpret IR Spectrum

Analyze infrared absorption spectra to identify functional groups, assess hydrogen bonding, and compile a comprehensive inventory of structural features present in the sample.

When to Use

Inputs

Procedure

Step 1: Establish Spectrum Quality and Format

Verify that the spectrum is suitable for interpretation before analyzing peaks:

  1. Check y-axis format: Determine whether the spectrum is plotted in %Transmittance (%T, peaks point down) or Absorbance (A, peaks point up). All subsequent analysis assumes consistent convention.
  2. Verify wavenumber range: Confirm the spectrum covers at least 4000--400 cm-1 for a standard mid-IR analysis. Note any truncation.
  3. Assess baseline: A good baseline should be relatively flat and near 100%T (or 0 Absorbance) in regions with no absorption. Sloping or noisy baselines reduce reliability.
  4. Check resolution: Adjacent peaks separated by less than the instrumental resolution cannot be distinguished. Typical FTIR resolution is 4 cm-1.
  5. Identify preparation artifacts: KBr pellets may show a broad O-H band from absorbed moisture (~3400 cm-1). Nujol mulls obscure C-H stretches. ATR spectra show intensity distortion at low wavenumbers. Note any artifacts that limit interpretation.

Got: Spectrum confirmed as suitable for analysis, with format, range, and artifacts documented.

If fail: If the spectrum has severe baseline problems, saturation (flat-bottomed peaks from too-concentrated samples), or preparation artifacts obscuring critical regions, note the limitation and flag affected spectral regions as unreliable.

Step 2: Scan the Diagnostic Region (4000--1500 cm-1)

Systematically analyze the high-frequency region where most functional groups produce characteristic absorptions:

  1. O-H stretches (3200--3600 cm-1): Look for broad absorptions. A sharp peak near 3600 cm-1 indicates free O-H; a broad band centered at 3200--3400 cm-1 indicates hydrogen-bonded O-H (alcohols, carboxylic acids, water).
  2. N-H stretches (3300--3500 cm-1): Primary amines show two peaks (symmetric and asymmetric stretch); secondary amines show one peak. These are sharper than O-H bands.
  3. C-H stretches (2800--3300 cm-1):

| Frequency (cm-1) | Assignment |

|---|---|

| 3300 | sp C-H (alkyne, sharp) |

| 3000--3100 | sp2 C-H (aromatic, vinyl) |

| 2850--3000 | sp3 C-H (alkyl, multiple peaks) |

| 2700--2850 | Aldehyde C-H (two peaks from Fermi resonance) |

  1. Triple-bond region (2000--2300 cm-1):

| Frequency (cm-1) | Assignment | Notes |

|---|---|---|

| 2100--2260 | C triple-bond C | Weak or absent if symmetric |

| 2200--2260 | C triple-bond N | Medium to strong |

| ~2350 | CO2 | Atmospheric artifact, disregard |

  1. Carbonyl region (1650--1800 cm-1) -- the most diagnostic single region in IR:

| Frequency (cm-1) | Assignment |

|---|---|

| 1800--1830, 1740--1770 | Acid anhydride (two C=O stretches) |

| 1770--1780 | Acid chloride |

| 1735--1750 | Ester |

| 1700--1725 | Carboxylic acid |

| 1705--1720 | Aldehyde |

| 1705--1720 | Ketone |

| 1680--1700 | Conjugated ketone / alpha-beta unsaturated |

| 1630--1690 | Amide (amide I band) |

  1. C=C and C=N stretches (1600--1680 cm-1): Alkene C=C appears at 1620--1680 cm-1 (weak to medium). Aromatic C=C shows multiple peaks near 1450--1600 cm-1. C=N (imine) appears at 1620--1660 cm-1.

Got: All absorptions in the diagnostic region identified, with functional group assignments and confidence levels (strong, tentative, absent).

If fail: If the carbonyl region is obscured (e.g., water absorption in KBr, atmospheric CO2), note the gap. If an expected functional group absorption is absent, confirm with a second preparation method before concluding it is truly absent.

Step 3: Analyze the Fingerprint Region (1500--400 cm-1)

Examine the lower-frequency region for confirmatory and structural detail:

  1. C-O stretches (1000--1300 cm-1): Ethers, esters, alcohols, and carboxylic acids produce strong C-O stretching absorptions. Esters show a characteristic strong band near 1000--1100 cm-1 in addition to the carbonyl.
  2. C-N stretches (1000--1250 cm-1): Amines and amides; overlap with C-O makes assignment tentative without other evidence.
  3. C-F, C-Cl, C-Br stretches:

| Frequency (cm-1) | Assignment |

|---|---|

| 1000--1400 | C-F (strong) |

| 600--800 | C-Cl |

| 500--680 | C-Br |

  1. Aromatic substitution pattern (700--900 cm-1): Out-of-plane C-H bending reveals substitution:

| Frequency (cm-1) | Pattern |

|---|---|

| 730--770 | Mono-substituted (+ 690--710) |

| 735--770 | Ortho-disubstituted |

| 750--810, 860--900 | Meta-disubstituted |

| 790--840 | Para-disubstituted |

  1. Overall fingerprint comparison: The fingerprint region is unique to each compound. If a reference spectrum is available, overlay and compare this region for identity confirmation.

Got: Confirmatory assignments for functional groups identified in Step 2, plus additional structural detail (substitution patterns, C-O/C-N assignments).

If fail: The fingerprint region is inherently complex and overlapping. If assignments are ambiguous, flag them as tentative and rely on the diagnostic region and other spectroscopic data for final conclusions.

Step 4: Assess Hydrogen Bonding and Intermolecular Effects

Evaluate how sample state and intermolecular interactions affect the spectrum:

  1. Hydrogen bonding broadening: Compare the width and position of O-H and N-H bands. Free O-H is sharp and near 3600 cm-1; hydrogen-bonded O-H is broad and shifted to 3200--3400 cm-1. Carboxylic acid dimers show a very broad O-H from 2500--3300 cm-1.
  2. Concentration and state effects: Solution spectra at different concentrations can distinguish intramolecular (concentration-independent) from intermolecular (concentration-dependent) hydrogen bonds.
  3. Fermi resonance: Two overlapping bands can interact to split into a doublet. The classic example is the aldehyde C-H pair near 2720 and 2820 cm-1. Recognize Fermi resonance to avoid misassigning extra peaks as separate functional groups.
  4. Solid-state effects: KBr pellets and Nujol mulls reflect solid-state packing, which broadens bands and can shift frequencies by 10--20 cm-1 relative to solution spectra. ATR spectra are closest to the neat liquid state.

Got: Hydrogen bonding state characterized, preparation-method artifacts accounted for, and any anomalous band shapes explained.

If fail: If hydrogen bonding effects cannot be resolved (e.g., overlapping O-H and N-H bands), note the ambiguity. A D2O exchange experiment or variable-temperature study can help, but these require additional data.

Step 5: Compile Functional Group Inventory

Assemble all findings into a structured report:

  1. List confirmed functional groups: Groups with strong, unambiguous absorptions in the diagnostic region (e.g., sharp C=O at 1715 cm-1 = ketone or aldehyde).
  2. List tentative assignments: Groups with weaker evidence or overlapping absorptions that could be explained by more than one functional group.
  3. List absent functional groups: Groups whose characteristic strong absorptions are clearly missing from the spectrum (e.g., no broad O-H band means no free alcohol or carboxylic acid).
  4. Note discrepancies: Any absorptions that do not fit the proposed functional group set, or expected absorptions that are missing.
  5. Cross-reference: Compare the IR-derived functional group inventory with information from other techniques (NMR, MS, UV-Vis) if available.

Got: A complete functional group inventory categorized by confidence level, with specific frequencies and intensities cited as evidence for each assignment.

If fail: If the inventory is incomplete or contradictory, identify which additional experiments (ATR vs. KBr comparison, variable concentration, D2O exchange) would resolve the ambiguities.

Validation

Pitfalls

Related Skills

Use this skill with your AI agent: Open on Skill Issue to copy, download, or add to your library. Works with Claude, ChatGPT, Gemini, Cursor, Windsurf and more.