Oncoprint mutation matrices

From GPTomics/bioSkills · View interactive version

Oncoprint mutation matrices is an AI agent skill from the GitHub repository GPTomics/bioSkills. Build OncoPrint and co-mutation matrix plots from somatic-variant cohorts using ComplexHeatmap, maftools, and comut.py with alteration-type stacking, sample ordering by mutational burden, mutual-exclusivity overlays, and clinical annotation tracks. Use when visualizing per-sample mutation patterns a

How to use this skill

Skill file

Version Compatibility

Reference examples tested with: ComplexHeatmap 2.18+, maftools 2.18+, comut 0.0.3+, MAFtools requires R 4.0+; comut.py requires pandas 2.0+, matplotlib 3.8+.

Before using code patterns, verify installed versions match. If versions differ:

If code throws ImportError, AttributeError, or TypeError, introspect the installed package and adapt the example to match the actual API rather than retrying.

OncoPrint and Mutation Matrix Plots

"Plot mutations across a cohort" -> Render a gene-by-sample matrix where each cell stacks colored rectangles encoding alteration class (missense, truncating, splice, copy-gain, copy-loss, fusion). Sort samples by burden, optionally split by clinical group, and overlay co-mutation / mutual-exclusivity annotations. OncoPrint (Cerami 2012 Cancer Discov 2:401; canonical at cBioPortal) is the genre-defining visualization.

The Single Most Important Modern Insight -- Cell Stacking Encodes Multiple Alterations Per Cell

OncoPrint differs from a generic heatmap because each cell can encode multiple alterations simultaneously through stacked rectangles. A patient with both a missense and a copy-gain in TP53 shows one cell with two overlapping colored rectangles (e.g., green diamond inside red square). This stacking is the whole point — it preserves the multi-modal alteration landscape that flattening to a single category destroys.

In ComplexHeatmap's oncoPrint, the alter_fun argument is the rendering specification: a named list of functions, one per alteration class, each drawing its rectangle inside the cell. Get this right and the figure works; get it wrong and overlapping alterations are invisible.

Decision Tree by Cohort and Question

| Question | Sort by | Display |

|----------|---------|---------|

| Which genes are most altered? | Gene frequency (default) | Bar above samples (sample TMB); bar right of genes (gene frequency) |

| Per-patient burden patterns | Sample burden | TMB bar on top; sample-name labels |

| Subtype-driver enrichment | Clinical group then burden | column_split by group; per-group frequency right bar |

| Mutual exclusivity (BRAF vs NRAS) | Custom (alphabetic-by-mutation pattern) | Memo sort; overlay log10(OR) heatmap |

| Co-occurrence (TP53 + MYC) | Custom | Same pattern; positive OR coloring |

| Driver vs passenger comparison | Two panels | Concatenate two oncoPrints horizontally |

ComplexHeatmap::oncoPrint -- Canonical Implementation

Goal: Render a cohort mutation matrix with stacked alteration-class encoding, sample annotations, and a sample-sorted, gene-frequency-ranked layout.

Approach: Convert the MAF/variant table to a gene-by-sample matrix of ;-delimited alteration strings; define alter_fun rendering one rectangle per class; pass to oncoPrint() with column annotations.

library(ComplexHeatmap)
library(circlize)

# Input: matrix where each cell is a string like 'Missense;Amp' or '' for no alteration
# Rows = genes; columns = samples

# Color per alteration class
col <- c('Missense'   = '#56B4E9',
         'Truncating' = '#000000',
         'Splice'     = '#CC79A7',
         'Amp'        = '#D55E00',
         'HomDel'     = '#0072B2',
         'Fusion'     = '#009E73')

# alter_fun -- one function per class, each drawing inside the cell
alter_fun <- list(
    background = function(x, y, w, h)
        grid.rect(x, y, w - unit(0.5, 'mm'), h - unit(0.5, 'mm'),
                  gp = gpar(fill = '#EEEEEE', col = NA)),
    Amp = function(x, y, w, h)
        grid.rect(x, y, w - unit(0.5, 'mm'), h - unit(0.5, 'mm'),
                  gp = gpar(fill = col['Amp'], col = NA)),
    HomDel = function(x, y, w, h)
        grid.rect(x, y, w - unit(0.5, 'mm'), h - unit(0.5, 'mm'),
                  gp = gpar(fill = col['HomDel'], col = NA)),
    Missense = function(x, y, w, h)
        grid.rect(x, y, w - unit(0.5, 'mm'), h * 0.5,
                  gp = gpar(fill = col['Missense'], col = NA)),
    Truncating = function(x, y, w, h)
        grid.rect(x, y, w - unit(0.5, 'mm'), h * 0.33,
                  gp = gpar(fill = col['Truncating'], col = NA)),
    Splice = function(x, y, w, h)
        grid.rect(x, y, w - unit(0.5, 'mm'), h * 0.25,
                  gp = gpar(fill = col['Splice'], col = NA)),
    Fusion = function(x, y, w, h)
        grid.points(x, y, pch = 17, size = unit(2, 'mm'),
                    gp = gpar(col = col['Fusion'])))

# Clinical column annotation
ha_clin <- HeatmapAnnotation(
    Subtype = clinical$subtype,
    Stage   = clinical$stage,
    col = list(Subtype = c(Luminal='#0072B2', Basal='#D55E00', HER2='#009E73'),
               Stage   = c(I='#FFFFCC', II='#FED976', III='#FD8D3C', IV='#BD0026')))

oncoPrint(mat,
          alter_fun = alter_fun,
          col = col,
          top_annotation = ha_clin,
          column_title = 'TCGA-BRCA mutation landscape',
          row_names_gp = gpar(fontsize = 8),
          pct_gp = gpar(fontsize = 7),
          show_pct = TRUE,
          remove_empty_columns = FALSE,
          remove_empty_rows = FALSE)

maftools::oncoplot -- Faster Onboarding

For TCGA-style MAF files, maftools::oncoplot is the lower-friction option:

library(maftools)
maf <- read.maf(maf = 'tcga.maf', clinicalData = clinical)
oncoplot(maf = maf,
         top = 20,                            # top 20 mutated genes
         clinicalFeatures = c('Subtype', 'Stage'),
         annotationColor = list(Subtype = c(Luminal='#0072B2', Basal='#D55E00'),
                                 Stage = c(I='#FFFFCC', IV='#BD0026')),
         sortByAnnotation = TRUE,
         removeNonMutated = FALSE)

maftools defaults handle alteration-class colors, sample sorting, and percentage bars automatically. Customization is more limited than ComplexHeatmap.

Mutual Exclusivity and Co-Occurrence

# maftools provides somaticInteractions
si <- somaticInteractions(maf = maf, top = 20,
                          pvalue = c(0.05, 0.01),
                          fontSize = 0.7)
# Plot returns a matrix of -log10(p) with sign by direction (+ co-occur, - mutex)

Mutual-exclusivity testing on small cohorts (N < 50) is underpowered; reported "significant" mutex on n=20 with 2 mutations each is uninterpretable. Aggregate to larger cohorts (TCGA + ICGC pan-cancer) or report effect size with CI rather than p-value.

Fisher exact vs DISCOVER: standard 2x2 Fisher tests sample-mutation pairs, ignoring per-gene mutation rate background. DISCOVER (Canisius 2016 Genome Biol 17:261) models per-tumor mutation probability and is preferred for pan-cancer analyses where mutation rate varies 100× across samples.

comut.py -- Python Equivalent

import comut
import pandas as pd

# Long-format: columns = sample, category (gene), value (alteration class)
toy_comut = comut.CoMut()
toy_comut.add_categorical_data(
    data=mutation_long_df,
    name='Mutations',
    category_order=top_genes,
    value_order=['Truncating', 'Missense', 'Splice', 'Amp', 'HomDel'],
    mapping={'Truncating': '#000000', 'Missense': '#56B4E9',
             'Splice': '#CC79A7', 'Amp': '#D55E00', 'HomDel': '#0072B2'})

toy_comut.add_categorical_data(
    data=clinical_long_df,
    name='Subtype',
    mapping={'Luminal': '#0072B2', 'Basal': '#D55E00'})

toy_comut.add_continuous_data(
    data=tmb_long_df,
    name='TMB',
    mapping='viridis',
    value_range=(0, 30))

toy_comut.plot_comut(figsize=(12, 8))
toy_comut.figure.savefig('comut.pdf', dpi=300, bbox_inches='tight')

Per-Method Failure Modes

Alterations flattened to a single class

Trigger: Reducing each cell to a single most-severe alteration, losing the stack.

Mechanism: Loses the multi-alteration biology (e.g., MYC amp + missense in TP53).

Symptom: OncoPrint looks like a simple heatmap; co-occurring multi-class events invisible.

Fix: Build the cell as ;-separated alteration string; define alter_fun for each class.

Sample sort by gene 1 frequency only

Trigger: Default oncoPrint sorts samples by altered-gene-1 status; weakens the "memo sort" pattern.

Mechanism: True OncoPrint uses memoSort (Cerami 2012) which sorts by the binary altered-or-not pattern across the top genes.

Symptom: Samples with the same alteration profile are not adjacent; "staircase" pattern lost.

Fix: ComplexHeatmap oncoPrint uses memoSort by default; do NOT override column_order unless intentional.

Showing only mutated samples (`remove_empty_columns = TRUE`)

Trigger: Default in some implementations.

Mechanism: Drops samples with no mutations in the displayed genes — but those samples ARE part of the cohort.

Symptom: Sample count differs from cohort N; denominator-based percentages wrong.

Fix: remove_empty_columns = FALSE to preserve all samples; percentages now reflect true cohort fraction.

Hypermutators dominate visual

Trigger: Cohort with 1-2 POLE-mutant or MSI-H samples; TMB bar saturates.

Mechanism: Hypermutator TMB is 10-100× the typical sample.

Symptom: All other samples' TMB bars are invisible; one column dominates.

Fix: Log-transform the TMB annotation: anno_barplot(log10(tmb + 1)); OR cap with ylim.

Mutex/co-occurrence p-values overinterpreted on small cohorts

Trigger: Fisher exact test on N < 50 with low mutation counts.

Mechanism: With 2 mutations vs 3 mutations in 20 samples, all p-values are dominated by noise.

Symptom: "Significant mutex" claim from a tiny pilot.

Fix: Aggregate to ≥100 samples for credible mutex; use DISCOVER (Canisius 2016) instead of Fisher when mutation rate varies 100× across samples.

Small-Cohort Regime (N = 20-50)

For rare-cancer cohorts where N < 50, the standard OncoPrint + Fisher mutex pipeline is statistically uninterpretable:

| Action | What to do |

|--------|------------|

| Report per-gene frequencies | Use exact-binomial CI (Clopper-Pearson via binom.test) — Wald CI is invalid at low frequency |

| Do NOT report mutex p-values | Fisher exact on 2x2 with cell counts ≤ 5 has no power; the "significant" mutex finding is noise |

| Hypothesis generation only | Pool with TCGA Pan-Cancer + ICGC for credible mutex; treat the cohort as the replication not the discovery |

| Co-occurrence reporting | OR with Haldane-Anscombe 0.5 correction for zero cells; report alongside cohort N |

Show the OncoPrint for visual transparency, but the per-gene-frequency table (with exact-binomial CIs) is the load-bearing scientific output, not the mutex test.

Reconciliation: When Implementations Differ

| Pattern | Cause | Action |

|---------|-------|--------|

| ComplexHeatmap and maftools show different sample orders | Different memoSort defaults | Specify sortByAnnotation explicitly; report sort criterion in caption |

| Percentage labels differ | remove_empty_columns = TRUE vs FALSE | Document denominator (cohort-N vs altered-N) |

| Some alterations missing from a sample | Filtering: silent SNVs, low VAF | Document filtering criteria upstream |

Quantitative Thresholds

| Threshold | Value | Source |

|-----------|-------|--------|

| Cohort N for valid mutex | ≥100 (pan-cancer); ≥50 (single-cohort with effect-size focus) | Common practice |

| Display top genes | 10-25 in single panel | More creates visual clutter |

| Sample N for OncoPrint | 50-1000 (above: switch to summary panel) | Visualization practical |

Common Errors

| Error / symptom | Cause | Solution |

|-----------------|-------|----------|

| Co-occurring multi-class events invisible | Single-class flattening | Use ;-separated cells + alter_fun list |

| Sample order doesn't show staircase | column_order override | Trust default memoSort |

| Sample count differs from cohort | remove_empty_columns = TRUE | Set to FALSE |

| TMB bar dominated by 1-2 samples | Hypermutators on linear scale | log10 + 1 transform |

| Mutex p-values on N=20 | Underpowered | Aggregate cohorts; use DISCOVER |

| Gene frequency right-bar mismatches percentages | Denominator definition | Document cohort-N vs altered-N |

References

Related Skills

Use this skill with your AI agent: Open on Skill Issue to copy, download, or add to your library. Works with Claude, ChatGPT, Gemini, Cursor, Windsurf and more.