HVAC Temperature Controller

When to Use

Targets

Workflow

  1. Calibration: Run a fixed-power heater step test (commonly ~50% power) long enough to capture the thermal rise clearly; prefer 30+ seconds and enough samples for model fitting (dense logging such as ~20+ points minimum, more when feasible) → calibration_log.json
  2. Parameter Estimation: Fit thermal model (K, tau) → estimated_params.json
  1. Gain Tuning: Start from the identified first-order model and use a standard model-based rule (prefer IMC/lambda; PI is a strong default for first-order thermal plants) before doing manual retuning → tuned_gains.json
  2. Closed-loop Control: Run to 22.0°C → control_log.json + metrics.json
  1. Verification & Finalization: Confirm the control run finished end-to-end; inspect estimated_params.json, tuned_gains.json, control_log.json, and metrics.json directly; compare every item in Targets against observed values using the original task-specified metric definitions; if evaluation code appears inconsistent with the spec, change it only to restore exact alignment with the stated definitions, then rerun and cross-check settling time, overshoot, and steady-state error against the raw trajectory before trusting metrics.json; ensure control_log.json and metrics.json come from the same latest completed run; and only then report success or emit any exact runtime/task-specified completion token.

If any required metric fails, do not present the task as complete. Continue tuning and rerun, or explicitly report the unmet requirement.

If 2-3 retuning attempts produce the same failing pattern (especially settling time, oscillation, or noise-driven non-settling), stop sweeping one gain knob and change the design: add measurement filtering, strengthen anti-windup, or switch tuning/control structure. Do not keep retrying the same PI/PID form with only a new lambda or gain scale once the failure pattern is unchanged.

  1. Protocol + plant/task pre-flight: Before any tool use, extract any task-mandated action schema, command wrapper, turn-taking rule, allowed tools, and exact completion token/string. Use that interface verbatim for every step. Also read the simulator/model and configuration files before choosing identification or tuning logic; extract the governing thermal equation when available, plus timestep, ambient conditions, noise, safety limits, and setpoint so the controller matches the actual process assumptions.

Prefer one reproducible end-to-end entry point that performs calibration, parameter estimation, gain tuning, closed-loop control, metrics calculation, and all required JSON writes in sequence, while keeping phases logically separable for targeted reruns.

Execution Discipline

Execution Discipline

Model

First-order thermal system:

Output Files

Tips