VR 2026 Conference Writing Skill
CCF-A | VR | Publisher: IEEE
Conference: https://ieeevr.org/2026
Template: VR/IEEEtran.cls (IEEEtran, conference format)
Document Setup
Preamble Structure
% === SUBMISSION MODE (anonymous, double-blind) ===
\documentclass[conference]{IEEEtran}
% Author block for anonymous submission:
\author{
\IEEEauthorblockN{Anonymous Author}
\IEEEauthorblockA{
\IEEEauthorrefmark{1}Anonymous Institution\\
anonymous@institution.edu}
}
% === CAMERA-READY MODE ===
\documentclass[conference]{IEEEtran}
% Restore full author/affiliation information
% Add conference-specific copyright notice
Required Packages
\usepackage{amsmath}
\usepackage{amsthm}
\usepackage{booktabs}
\usepackage{graphicx}
\usepackage{cite}
\usepackage{balance}
\usepackage{cleveref}
\usepackage{algorithm}
\usepackage{algorithmic}
\usepackage{url}
\usepackage{xcolor}
Page Limits
| Section | Limit |
|---------|-------|
| Main paper (submission) | 8 pages |
| References | No limit |
| Appendix | Check CFP |
VR typically enforces an 8-page limit for the main body. References do not count toward the limit. Verify the current CFP for exact limits.
Anonymity Requirements
VR uses double-blind review. Since IEEEtran does not have built-in anonymous mode:
- Remove or replace author names/affiliations in the submission
- Use "Anonymous" as author during submission
- Third-person self-citations: "Smith et al. showed..." not "we showed..."
- Anonymize all URLs, GitHub links, project pages, video links
- Clear PDF metadata
- Remove acknowledgments
- Anonymize hardware identifiers and system configurations
Camera-Ready Differences
After acceptance:
- Restore all author names and affiliations
- Add the conference-specific copyright notice provided by IEEE
- Ensure Xplore-compatible PDF (CMYK colors, embedded fonts)
- Submit via IEEE PDF eXpress
Section Organization
VR papers typically follow a human-centered VR research structure:
- Abstract — Concise summary
- Introduction — VR/AR problem, user experience challenge, contributions
- Background & Related Work — VR/AR foundations, prior systems
- System Design — Hardware setup, software architecture
- User Study / Evaluation — Methodology, participants, tasks, metrics
- Results — Quantitative and qualitative findings
- Discussion — Implications, limitations, design guidelines
- Conclusion
- References
- Appendix (optional)
VR/AR-Specific Content
Hardware Setup Description
VR papers require detailed hardware descriptions:
\section{System Design}
\subsection{Hardware Configuration}
We implemented the system on an Oculus Quest 3 headset running at
90 Hz refresh rate with a display resolution of 2064x2208 pixels
per eye. The participant's position was tracked using the headset's
inside-out tracking system with sub-millimeter accuracy.
The application was developed in Unity 2023.2 with the XR Interaction
Toolkit. Audio feedback was delivered via the headset's integrated
speakers with head-related transfer function (HRTF) processing.
User Study Methodology
VR papers require rigorous user study methodology:
\section{Evaluation}
\subsection{Participants}
We recruited 24 participants (12 female, 12 male, age $M=28.3$, $SD=4.2$)
from the university community. All participants had normal or
corrected-to-normal vision and reported no history of motion sickness.
Participants were randomly assigned to two conditions in a between-subjects
design. Sample size was determined via power analysis ($\alpha=0.05$, power=0.8$).
\subsection{Procedure}
After providing informed consent, participants completed a demographic
questionnaire and a simulator sickness questionnaire (SSQ) baseline.
They then underwent a 5-minute training period followed by the main
experimental task. After each condition, participants completed the
SSQ, the presence questionnaire (PQ), and a subjective preference questionnaire.
\subsection{Metrics}
We measured: (1) task completion time, (2) error rate, (3) SSQ scores,
(4) presence questionnaire (PQ) scores, and (5) subjective preference rankings.
Presence and Simulator Sickness
VR papers commonly report standardized questionnaires:
% Common VR metrics to report:
\begin{itemize}
\item \textbf{Simulator Sickness Questionnaire (SSQ)}: Kennedy et al.
\item \textbf{Presence Questionnaire (PQ)}: Slater et al.
\item \textbf{ITQ (Immersive Tendency Questionnaire)}: Slater et al.
\item \textbf{SSQ subscales}: Nausea, Oculomotor, Disorientation
\end{itemize}
Figures and Tables
- IEEE single-column format
- Grayscale legibility required
- Use high-resolution figures (minimum 300 DPI)
- Include hardware setup photos when relevant
\begin{figure}[t]
\centering
\includegraphics[width=0.9\linewidth]{figs/system-setup}
\caption{The VR training system setup showing: (a) the head-mounted
display with hand controllers, (b) the tracked workspace boundaries,
and (c) the experimenter's monitoring station.}
\label{fig:setup}
\end{figure}
References
\bibliographystyle{IEEEtran}
\bibliography{references}
% Numeric citations
\cite{kennedy1993simulator}
Formatting Rules
- Format: IEEE conference (single-column)
- Paper size: US Letter
- Body font: 10pt minimum
- Margins: 1" all sides
- Xplore-compatible PDF: CMYK colors, embedded fonts
Submission Checklist
- [ ] 8 pages or fewer (main body)
- [ ] Author information removed/anonymized
- [ ] Third-person self-citations only
- [ ] Anonymized all URLs and video links
- [ ] PDF metadata cleared
- [ ] User study methodology clearly described
- [ ] Hardware setup specified
- [ ] Standard VR metrics reported (SSQ, presence)
- [ ] Grayscale-legible figures
Camera-Ready Checklist
- [ ] Restore author information
- [ ] Add IEEE copyright notice
- [ ] Generate Xplore-compatible PDF
- [ ] Use CMYK colors for figures
- [ ] Embed all fonts
- [ ] Submit via IEEE PDF eXpress