MICCAI 2026 Conference Writing Skill
CCF-B | Medical Imaging / AI | Publisher: Springer
Conference: https://miccai2026.org
Template: MICCAI/MICCAI2026-main conference paper template.tex (modified llncs.cls)
Important: The MICCAI template is pre-configured for double-blind submission. The author block is already anonymized. Do not remove or modify it to gain extra writing space — doing so will lead to desk rejection.
Document Setup
Preamble Structure
The MICCAI template is pre-configured for anonymized submission. Use it as-is:
\documentclass[runningheads]{llncs}
\usepackage[T1]{fontenc}
\usepackage{graphicx,verbatim}
Author Block (Pre-anonymized)
The template provides a pre-anonymized author block. For submission, use:
\author{Anonymized Authors}
\authorrunning{Anonymized Author et al.}
\institute{Anonymized Affiliations \\
\email{email@anonymized.com}}
For camera-ready, restore real author information:
\author{First Author\inst{1}\orcidID{0000-1111-2222-3333} \and
Second Author\inst{2}\orcidID{1111-2222-3333-4444}}
\authorrunning{F. Author et al.}
\institute{Institution 1\\
email@example.com \and
Institution 2\\
email2@example.com}
Page Limits
| Section | Limit |
|---------|-------|
| Main content | 8 pages (text, figures, tables, abstract, keywords, acknowledgments) |
| References | up to 2 pages |
| Supplementary materials | Multimedia only (videos); no PDF supplementary |
Important:
- Acknowledgments and disclaimer count toward the 8-page limit if included in the submission
- The reference section does not need to start on a new page
- PDF supplementary materials are not allowed in 2026 unless citing an unpublished paper
Anonymity Requirements
MICCAI uses strict double-blind review:
- Do not modify or remove the provided anonymized author section
- Cite your own prior work in third person
- Anonymize all URLs (GitHub repositories, dataset links)
- Mask data collection locations for private datasets
- Ensure supplementary materials (videos) contain no identifying information
- Clear PDF metadata
- Do not upload anonymized drafts to public repositories
Abstract and Keywords
\begin{abstract}
The abstract should briefly summarize the contents of the paper
in 150--250 words. If you include a repository link, ensure it is
anonymized for the double-blind review phase.
\end{abstract}
\keywords{First keyword \and Second keyword \and Another keyword.}
% Authors must provide keywords and are not allowed to remove this section.
Section Organization
MICCAI papers typically follow this structure:
- Introduction — Medical/clinical problem, motivation, contributions
- Related Work — Prior medical imaging research
- Methods — Proposed model, architecture, training procedure
- Experiments / Results — Datasets, evaluation metrics, comparisons with state-of-the-art
- Discussion — Clinical significance, limitations
- Conclusion
- References
- Acknowledgments (counts toward page limit)
- Disclosure of Interests (counts toward page limit)
Figures and Tables
\begin{figure}
\centering
\includegraphics[width=0.8\linewidth]{fig1}
\caption{A figure caption placed below the illustration.}
\label{fig:sample}
\end{figure}
Rules:
- No inline figures (wrapping text around figures is not allowed)
- Minimum 8pt font size for table text
- Tables must not be inserted as figures
- Ensure figures and tables do not extend into the margins
- Use EPS or vector formats where possible
References (numbered)
LNCS uses numbered citations with splncs04.bst:
\bibliographystyle{splncs04}
\bibliography{references}
% Citations:
\cite{key} % [1]
\cite{key1,key2} % [1,2]
Theorem Environments
\begin{theorem}
This is a sample theorem.
\end{theorem}
\begin{proof}
Proof text...
\end{proof}
MICCAI supports: theorem, definition, lemma, proposition, corollary, remark, example.
Disallowed Formatting
The following are strictly prohibited and will result in desk rejection:
\vspaceor\hspacecommands to reduce whitespace- Changing default margins, font size, or font type
- Inline figures (wrapping text)
- Tables inserted as figures
- PDF supplementary materials (unless citing unpublished work)
- Modifying the anonymized author section
Camera-Ready Checklist
After acceptance:
- [ ] Remove the anonymized author block and insert real author names, affiliations, and ORCID IDs
- [ ] Restore acknowledgments and disclosure of interest sections
- [ ] Verify total page count (main content ≤ 8 pages, references ≤ 2 pages)
- [ ] Ensure all author-provided keywords are included
- [ ] Check that figures/tables do not extend into margins
- [ ] Remove anonymity from any repository links
MICCAI-Specific Writing Conventions
- Clinical relevance: Clearly explain the medical/clinical significance
- Datasets: Describe medical imaging datasets (source, modality, size, demographics)
- Evaluation metrics: Report standard medical imaging metrics (Dice score, IoU, sensitivity, specificity)
- Statistical reporting: Include mean ± standard deviation, p-values where appropriate
- Reproducibility: Include key hyperparameters, preprocessing pipeline, and model architecture details
- Visual quality: High-quality figures are essential; include representative slices/3D views