1. When to use, and when not
Use this skill when you need to assess manufacturing feasibility for
an intervention concept:
- Stage 0 gate: does the proposed modality + delivery combination
have a plausible production path at all?
- SA-score interpretation for manufacturing: what does the SA-score
mean for manufacturing feasibility (as distinct from drug-likeness)?
- Pre-entity concepts: a concept with no physical entity yet should
produce not_yet_applicable, not a failure — this skill handles
that correctly.
- Biologic manufacturing: qualitative assessment of expression
system feasibility for antibodies, biologics, peptides, etc.
- Complexity flagging: stereocenter/step-count heuristics for
prioritization (NOT for automatic rejection).
Do not use when:
- You need drug-likeness or compound property profiling
-> compound-property-profile.
- You need pocket druggability
-> pocket-druggability.
- You need a demonstrated synthetic route or retrosynthetic analysis
-> not yet tooled; report as blocked.
- You need real process chemistry, formulation, or developability data
-> Stages 2-4; underlying tools not yet available.
- You need GMP or regulatory manufacturing readiness
-> Stage 4; not yet implemented.
2. Preconditions
- Input: a concept record (JSON) with at least
modality.
Optionally entity_ref (compound SMILES, sequence identifier, or
construct ID) and delivery_assumptions (route, formulation, vehicle).
- SA-score (optional): if a small-molecule concept has a structure,
an existing SA-score record from oase compound sa-score can be
incorporated. The SA-score is NOT recomputed by this skill — use
the existing compound sa-score command to compute it first.
- RDKit (optional): if installed, complexity heuristics
(stereocenter count, ring analysis, step estimates) are computed
from the entity_ref SMILES. If RDKit is not available, these
heuristics are skipped (not fabricated).
- No authentication needed — all operations are local.
- No network — all operations are offline.
3. Tool invocations
| Question | Run | Writes to |
|---|---|---|
| Does this concept have a plausible manufacturing path? | oase manufacturing assess-stage0 <CONCEPT_PATH> | raw/manufacturing/<IC-NNN>.manufacturing-stage0.json |
| What are the stage-gated requirement structures? | oase manufacturing stage-requirements | (stdout only) |
| What is this compound's SA-score? (prerequisite) | oase compound sa-score <SMILES> | raw/compounds/<slug>.sa-score.json |
To incorporate SA-score into the manufacturing assessment:
oase compound sa-score <SMILES>
oase manufacturing assess-stage0 <CONCEPT_PATH> --sa-score-path raw/compounds/<slug>.sa-score.json
4. Interpretation contract
The SA-score distinction (CRITICAL)
SA-score is NOT synthesizability. The SA-score (Ertl & Schuffenhauer
2009) is a fragment-frequency heuristic: it rates how common the
molecule's fragments are in known compounds, on a 1-10 scale (1 = easy,
10 = hard).
- A low SA-score does NOT mean the molecule is synthesizable —
it means its substructures are common in known chemistry.
- A high SA-score does NOT mean the molecule cannot be synthesized
— it means its substructures are unusual.
- Neither substitutes for a demonstrated synthetic route or a
scalable manufacturing process.
This distinction must survive into every finding. A finding that says
"this compound is manufacturable because SA-score = 2.1" has collapsed
the distinction. The correct statement is "SA-score 2.1 indicates
common substructure fragments; manufacturing feasibility requires route
analysis."
Stereocenter/step-count heuristics
Stereocenter counts and estimated step counts are **scoped heuristics
for prioritization**, not universal scientific vetoes.
- A molecule with many stereocenters is **flagged with the specific
concern** — it is not automatically rejected.
- The requirement type is
prioritization_heuristic(informs ordering)
or sponsor-specific hard_constraint (per #11 policy) — never an
unconditional scientific_cutoff that silently kills a concept.
- Step-count estimates are derived from molecular size, not from
retrosynthetic analysis. They are rough ranges, not predictions.
Pre-entity concepts
A concept with entity_ref: null (no physical entity yet) produces
not_yet_applicable for entity-level manufacturing assessments. This
is per #75's evidence status semantics:
not_yet_applicable= cannot be assessed at this stage, with a
later trigger.
- NOT
not_assessed(which would mean no assessment was performed —
but we did assess and determined it's not applicable yet).
- NOT a failure or error.
- NOT a fabricated result.
The trigger for future assessment is documented in the finding: it
becomes applicable when entity_ref is populated.
No fabrication
**No yield, cost of goods, stability, or formulation property may be
invented.** If the data does not exist:
- The evidence status is
not_assessedornot_yet_applicable - Never a plausible-looking number
- The finding explicitly states what is NOT assessed
- The
next_evidencefield names what would be needed
Qualitative Phase 1 findings cite:
- Precedent: established production platforms for the modality
- Assumptions: listed explicitly (e.g., standard infrastructure)
- Limitations: what is NOT assessed (e.g., sequence liabilities)
- Owner: who should perform the next assessment
- Next required evidence: what Stage 2+ would need
Stage-gated requirements
Manufacturing assessment uses progressive requirements:
| Stage | Assessment | Status |
|---|---|---|
| 0 | Product/modality/delivery and production-platform fit | Implemented |
| 2 | Entity/route or therapeutic-sequence feasibility | Placeholder |
| 3 | Formulation/process/developability evidence | Placeholder |
| 4 | Supply and applicable readiness evidence | Placeholder |
Stages 2-4 are defined structurally (evidence types, required inputs)
so that #11 policy requirements can reference them by evidence_type.
Their actual assessment logic is not implemented because the underlying
tools do not exist yet.
Reassessment
Manufacturing assessment records use the supersedes field from #75's
assessment schema (§2.2). An initial manufacturing concern can be
superseded by a new assessment when new evidence arrives. This keeps
manufacturing obstacles eligible for reviewed reassessment under #78.
Neither early screen implies GMP or manufacturing clearance
Stage 0 manufacturing assessment is a coarse feasibility check. It
determines whether a plausible production path exists for the proposed
modality, not whether the product can be manufactured at clinical or
commercial scale.
5. Failure modes and anti-fabrication guard
Do not compute these values yourself. The value is whatever the
tool emitted. If the tool did not run, there is no value. If a
required tool is unavailable, report the task as blocked. Do not
estimate, and do not proceed on an assumed result.
Named pathologies
- Treating SA-score as synthesizability. SA-score 2.0 does NOT
mean "this compound can be synthesized." It means the substructures
are common in known chemistry. Manufacturing feasibility requires a
demonstrated route, not a heuristic score.
- Treating stereocenter count as an automatic rejection. A
molecule with 5 stereocenters requires careful planning, but is not
automatically unmanufacturable. Taxol has 11 stereocenters and is
manufactured at scale. Flag the concern; do not reject.
- Fabricating yield, cost, or stability data. These require real
process data. A plausible-looking number ("estimated yield 45%")
is fabrication. The correct output is not_assessed with a
next_evidence pointing to the required data.
- Confusing modality-level and entity-level assessment. A
"biologic" modality has known production platforms (modality-level:
supported). Whether a specific antibody sequence can be expressed
without aggregation is an entity-level question (requires sequence
analysis). The skill keeps these distinct.
- Treating not_yet_applicable as a failure. A pre-entity concept
that produces not_yet_applicable is correctly assessed — the
assessment is that entity-level manufacturing evaluation cannot
happen yet, not that it failed.