Regulatory affairs head

From robertbstillwell/marketing-skills · View interactive version

Regulatory affairs head is an AI agent skill from the GitHub repository robertbstillwell/marketing-skills. Senior Regulatory Affairs Manager for HealthTech and MedTech companies. Provides regulatory strategy development, submission management, pathway analysis, global compliance coordination, and cross-functional team leadership.

How to use this skill

Skill file

Head of Regulatory Affairs

Regulatory strategy development, submission management, and global market access for medical device organizations.


Table of Contents


Regulatory Strategy Workflow

Develop regulatory strategy aligned with business objectives and product characteristics.

Workflow: New Product Regulatory Strategy

  1. Gather product information:
  1. Identify applicable regulations per target market:
  1. Determine optimal regulatory pathway:
  1. Develop regulatory timeline with milestones
  2. Estimate resource requirements and budget
  3. Identify regulatory risks and mitigation strategies
  4. Obtain stakeholder alignment and approval
  5. Validation: Strategy document approved; timeline accepted; resources allocated

Regulatory Pathway Selection Matrix

| Factor | 510(k) | De Novo | PMA |

|--------|--------|---------|-----|

| Predicate Available | Yes | No | N/A |

| Risk Level | Low-Moderate | Low-Moderate | High |

| Clinical Data | Usually not required | May be required | Required |

| Review Time | 90 days (MDUFA) | 150 days | 180 days |

| User Fee | ~$22K (2024) | ~$135K | ~$440K |

| Best For | Me-too devices | Novel low-risk | High-risk, novel |

Regulatory Strategy Document Template

REGULATORY STRATEGY

Product: [Name]
Version: [X.X]
Date: [Date]

1. PRODUCT OVERVIEW
   - Intended use: [Statement]
   - Device classification: [Class I/II/III]
   - Technology: [Description]

2. TARGET MARKETS
   | Market | Priority | Timeline |
   |--------|----------|----------|
   | USA    | 1        | Q1 20XX  |
   | EU     | 2        | Q2 20XX  |

3. REGULATORY PATHWAY
   - FDA: [510(k) / De Novo / PMA]
   - EU: [Class] via [Conformity route]
   - Rationale: [Justification]

4. CLINICAL EVIDENCE STRATEGY
   - Requirements: [Summary]
   - Approach: [Literature / Study / Both]

5. TIMELINE AND MILESTONES
   [Gantt or milestone table]

6. RISKS AND MITIGATION
   | Risk | Probability | Impact | Mitigation |
   |------|-------------|--------|------------|

7. RESOURCE REQUIREMENTS
   - Budget: $[Amount]
   - Personnel: [FTEs]
   - External support: [Consultants, CRO]

FDA Submission Workflow

Prepare and submit FDA regulatory applications.

Workflow: 510(k) Submission

  1. Confirm 510(k) pathway suitability:
  1. Schedule and conduct Pre-Submission (Q-Sub) meeting if needed
  2. Compile submission package:
  1. Conduct internal review and quality check
  2. Prepare eCopy per FDA format requirements
  3. Submit via FDA ESG portal with user fee payment
  4. Monitor MDUFA clock and respond to AI/RTA requests
  5. Validation: Submission accepted; MDUFA date received; tracking system updated

Workflow: PMA Submission

  1. Confirm PMA pathway:
  1. Complete IDE clinical study if required:
  1. Conduct Pre-Submission meeting
  2. Compile PMA submission:
  1. Submit original PMA application
  2. Address FDA questions and deficiencies
  3. Prepare for FDA facility inspection
  4. Validation: PMA approved; approval letter received; post-approval requirements documented

FDA Submission Timeline

| Milestone | 510(k) | De Novo | PMA |

|-----------|--------|---------|-----|

| Pre-Sub Meeting | Day -90 | Day -90 | Day -120 |

| Submission | Day 0 | Day 0 | Day 0 |

| RTA Review | Day 15 | Day 15 | Day 45 |

| Substantive Review | Days 15-90 | Days 15-150 | Days 45-180 |

| Decision | Day 90 | Day 150 | Day 180 |

Common FDA Deficiencies

| Category | Common Issues | Prevention |

|----------|---------------|------------|

| Substantial Equivalence | Weak predicate comparison | Strong SE argument upfront |

| Performance Testing | Incomplete test protocols | Follow recognized standards |

| Biocompatibility | Missing endpoints | ISO 10993 risk assessment |

| Software | Inadequate documentation | IEC 62304 compliance |

| Labeling | Inconsistent claims | Early labeling review |

See: references/fda-submission-guide.md


EU MDR Submission Workflow

Achieve CE marking under EU MDR 2017/745.

Workflow: MDR Technical Documentation

  1. Confirm device classification per MDR Annex VIII
  2. Select conformity assessment route based on class:
  1. Select and engage Notified Body (for Class IIa+)
  2. Compile Technical Documentation per Annex II:
  1. Establish and document QMS per ISO 13485
  2. Submit application to Notified Body
  3. Address NB questions and coordinate audit
  4. Validation: CE certificate issued; Declaration of Conformity signed; EUDAMED registration complete

MDR Classification Decision Tree

Is the device active?
        │
    Yes─┴─No
     │     │
     ▼     ▼
Is it an   Does it contact
implant?   the body?
  │            │
Yes─┴─No   Yes─┴─No
 │    │     │     │
 ▼    ▼     ▼     ▼
III  IIb  Check   Class I
         contact  (measuring/
         type     sterile if
         and      applicable)
         duration

Clinical Evidence Requirements by Class

| Class | Clinical Requirement | Documentation |

|-------|---------------------|---------------|

| I | Clinical evaluation (CE) | CE report |

| IIa | CE with literature focus | CE report + PMCF plan |

| IIb | CE with clinical data | CE report + PMCF + clinical study (some) |

| III | CE with clinical investigation | CE report + PMCF + clinical investigation |

Notified Body Selection Criteria

| Criterion | Consideration |

|-----------|---------------|

| Scope | Device category expertise |

| Capacity | Availability and review timeline |

| Experience | Track record in your technology |

| Geography | Proximity for audits |

| Cost | Fee structure transparency |

| Communication | Responsiveness and clarity |

See: references/eu-mdr-submission-guide.md


Global Market Access Workflow

Coordinate regulatory approvals across international markets.

Workflow: Multi-Market Submission Strategy

  1. Define target markets based on business priorities
  2. Sequence markets for efficient evidence leverage:
  1. Identify local requirements per market:
  1. Develop master technical file with localization plan
  2. Establish in-country regulatory support
  3. Execute parallel or sequential submissions
  4. Track approvals and coordinate launches
  5. Validation: All target market approvals obtained; registration database updated

Market Priority Matrix

| Market | Size | Complexity | Recognition | Priority |

|--------|------|------------|-------------|----------|

| USA | Large | High | N/A | 1 |

| EU | Large | High | N/A | 1-2 |

| Canada | Medium | Medium | MDSAP | 2 |

| Australia | Medium | Low | EU accepted | 2 |

| Japan | Large | High | Local clinical | 3 |

| China | Large | Very High | Local testing | 3 |

| Brazil | Medium | High | GMP inspection | 3-4 |

Documentation Efficiency Strategy

| Document Type | Single Source | Localization Required |

|---------------|---------------|----------------------|

| Technical file core | Yes | Format adaptation |

| Risk management | Yes | None |

| Clinical data | Yes | Bridging assessment |

| QMS certificate | Yes (ISO 13485) | Market-specific audit |

| Labeling | Master label | Translation, local requirements |

| IFU | Master content | Translation, local symbols |

See: references/global-regulatory-pathways.md


Regulatory Intelligence Workflow

Monitor and respond to regulatory changes affecting product portfolio.

Workflow: Regulatory Change Management

  1. Monitor regulatory sources:
  1. Assess relevance to product portfolio
  2. Evaluate impact:
  1. Develop compliance action plan
  2. Communicate to affected stakeholders
  3. Implement required changes
  4. Document compliance status
  5. Validation: Compliance action plan approved; changes implemented on schedule

Regulatory Monitoring Sources

| Source | Type | Frequency |

|--------|------|-----------|

| FDA Federal Register | Regulations, guidance | Daily |

| FDA Device Database | 510(k), PMA, recalls | Weekly |

| EU Official Journal | MDR/IVDR updates | Weekly |

| MDCG Guidance | EU implementation | As published |

| ISO/IEC | Standards updates | Quarterly |

| Notified Body | Audit findings, trends | Per interaction |

Impact Assessment Template

REGULATORY CHANGE IMPACT ASSESSMENT

Change: [Description]
Source: [Regulation/Guidance]
Effective Date: [Date]
Assessment Date: [Date]
Assessed By: [Name]

AFFECTED PRODUCTS
| Product | Impact | Action Required | Timeline |
|---------|--------|-----------------|----------|
| [Name]  | [H/M/L]| [Description]   | [Date]   |

COMPLIANCE ACTIONS
1. [Action 1] - Owner: [Name] - Due: [Date]
2. [Action 2] - Owner: [Name] - Due: [Date]

RESOURCE REQUIREMENTS
- Budget: $[Amount]
- Personnel: [Hours/FTEs]

APPROVAL
Regulatory: _________________ Date: _______
Management: _________________ Date: _______

Decision Frameworks

Pathway Selection Decision Tree

Is predicate device available?
            │
        Yes─┴─No
         │     │
         ▼     ▼
    Is device   Is risk level
    substantially  Low-Moderate?
    equivalent?       │
         │        Yes─┴─No
     Yes─┴─No      │     │
      │     │      ▼     ▼
      ▼     ▼   De Novo  PMA
    510(k)  Consider      required
           De Novo
           or PMA

Pre-Submission Meeting Decision

| Factor | Schedule Pre-Sub | Skip Pre-Sub |

|--------|------------------|--------------|

| Novel Technology | ✓ | |

| New Intended Use | ✓ | |

| Complex Testing | ✓ | |

| Uncertain Predicate | ✓ | |

| Clinical Data Needed | ✓ | |

| Well-established | | ✓ |

| Clear Predicate | | ✓ |

| Standard Testing | | ✓ |

Regulatory Escalation Criteria

| Situation | Escalation Level | Action |

|-----------|------------------|--------|

| Submission rejection | VP Regulatory | Root cause analysis, strategy revision |

| Major deficiency | Director | Cross-functional response team |

| Timeline at risk | Management | Resource reallocation review |

| Regulatory change | VP Regulatory | Portfolio impact assessment |

| Safety signal | Executive | Immediate containment and reporting |


Tools and References

Scripts

| Tool | Purpose | Usage |

|------|---------|-------|

| regulatory_tracker.py | Track submission status and timelines | python regulatory_tracker.py |

Regulatory Tracker Features:

References

| Document | Content |

|----------|---------|

| fda-submission-guide.md | FDA pathways, requirements, review process |

| eu-mdr-submission-guide.md | MDR classification, technical documentation, clinical evidence |

| global-regulatory-pathways.md | Canada, Japan, China, Australia, Brazil requirements |

| iso-regulatory-requirements.md | ISO 13485, 14971, 10993, IEC 62304, 62366 requirements |

Key Performance Indicators

| KPI | Target | Calculation |

|-----|--------|-------------|

| First-time approval rate | >85% | (Approved without major deficiency / Total submitted) × 100 |

| On-time submission | >90% | (Submitted by target date / Total submissions) × 100 |

| Review cycle compliance | >95% | (Responses within deadline / Total requests) × 100 |

| Regulatory hold time | <20% | (Days on hold / Total review days) × 100 |


Related Skills

| Skill | Integration Point |

|-------|-------------------|

| mdr-745-specialist | Detailed EU MDR technical requirements |

| fda-consultant-specialist | FDA submission deep expertise |

| quality-manager-qms-iso13485 | QMS for regulatory compliance |

| risk-management-specialist | ISO 14971 risk management |

Use this skill with your AI agent: Open on Skill Issue to copy, download, or add to your library. Works with Claude, ChatGPT, Gemini, Cursor, Windsurf and more.