Neqsim utility design

From equinor/neqsim · View interactive version

Neqsim utility design is an AI agent skill from the GitHub repository equinor/neqsim. Screening-level utility-system design with NeqSim and the MCP designUtilities tool - fired Boiler, Deaerator, RefrigerationCycle, NitrogenSystem, multi-pressure SteamNetwork and the UtilitySystemDesigner that harvests demands from a run flowsheet. USE WHEN: sizing a utility duty/flow/power, estimati

How to use this skill

Skill file

NeqSim Utility Design Skill

Size and cost the core plant utilities with deterministic NeqSim models in

neqsim.process.util.utilitydesign. This skill covers the calculation side

(duties → flows → power → CO₂ → cost); use

CODE0 to

decide which utility levels to provide and

CODE0 to derive the duties.

When to Use

These are screening-level models for early design, not detailed mechanical design.

Classes

All classes live in neqsim.process.util.utilitydesign, expose

public static final String SCHEMA_VERSION = "1.0", and provide

calculate(), toResultsMap(), and toJson(). Each has a no-arg and a

String name constructor.

| Class | Models | Key inputs | Key outputs |

|-------|--------|-----------|-------------|

| Boiler | Fired steam boiler package | steam duties (kW), efficiency, fuel LHV | fuel mass, steam generation, feedwater/blowdown, fan power, CO₂, OPEX |

| Deaerator | Feedwater deaerator | feedwater flow, inlet T, pressure | deaerator T, heat duty, stripping steam, vent rate |

| RefrigerationCycle | Vapour-compression chiller (Carnot × efficiency) | duties (kW), evaporator/condenser T | COP, compressor power, condenser duty, CO₂, OPEX |

| NitrogenSystem | On-site N₂ generation | demand (Nm³/h), purity, method | specific energy, power, air feed, CO₂, OPEX |

| SteamNetwork | Multi-pressure header cascade + embedded Boiler/Deaerator | levels, demands, local generation | per-header balance, boiler generation, totals |

| UtilitySystemDesigner | Plant-wide aggregator | run ProcessSystem/ProcessModel | total heating/cooling/shaft/air, CW + air-cooler split |

Boiler

import neqsim.process.util.utilitydesign.Boiler;

Boiler boiler = new Boiler("HP Boiler");
boiler.setBoilerEfficiency(0.85);
boiler.setFuelLowHeatingValueMJperKg(47.0);
boiler.addSteamDuty("Reboiler", 5000.0); // kW; negative duty is rejected
boiler.calculate();
double fuelKgh = boiler.getFuelMassDemandKgh();
double steamKgh = boiler.getSteamGenerationKgh();
double co2 = boiler.getCo2TonnePerYear();
String json = boiler.toJson();

RefrigerationCycle

COP is (T_evap/ΔT) × cycleEfficiency (Carnot fraction). Condenser duty is the

evaporator duty plus compressor power.

import neqsim.process.util.utilitydesign.RefrigerationCycle;

RefrigerationCycle cycle = new RefrigerationCycle("Propane Chiller");
cycle.setEvaporatorTempC(-35.0);
cycle.setCondenserTempC(35.0);
cycle.setCycleEfficiency(0.55);
cycle.addRefrigerationDuty("Gas Chilling", 3000.0); // kW
cycle.calculate();
double power = cycle.getCompressorPowerKW();
double cop = cycle.getCop();

NitrogenSystem

Generation method sets the specific energy and air-to-product ratio; purity above

99% adds a small energy penalty.

import neqsim.process.util.utilitydesign.NitrogenSystem;

NitrogenSystem n2 = new NitrogenSystem("N2 Generation");
n2.setNitrogenDemandNm3h(500.0);
n2.setPurityPercent(99.5);
n2.setGenerationMethod(NitrogenSystem.GenerationMethod.MEMBRANE); // or PSA, CRYOGENIC
n2.calculate();
double powerKW = n2.getPowerKW();
double airFeed = n2.getAirFeedNm3h();

SteamNetwork

Headers are sorted descending by pressure; the cascade balances each header

top-down and the top header's make-up sets the boiler generation.

import neqsim.process.util.utilitydesign.SteamNetwork;

SteamNetwork net = new SteamNetwork("Steam System");
net.addLevel("HP", 42.0, 253.0);   // name, pressure bara, saturation T °C
net.addLevel("LP", 4.5, 148.0);
net.addDemand("HP", 8000.0);        // kg/h; unknown header throws
net.addDemand("LP", 5000.0);
net.setLocalGeneration("LP", 2000.0);
net.calculate();
double boilerKgh = net.getBoilerGenerationKgh();

UtilitySystemDesigner (flowsheet aggregator)

import neqsim.process.util.utilitydesign.UtilitySystemDesigner;

processSystem.run();
UtilitySystemDesigner u = UtilitySystemDesigner.fromProcessSystem(processSystem).design();
double heating = u.getTotalHeatingDutyKW();
double cooling = u.getTotalCoolingDutyKW();
double cwFlow = u.getCoolingWaterFlowM3h();
// For a ProcessModel: UtilitySystemDesigner.fromProcessModel(plant)

MCP `designUtilities` tool

The MCP server (neqsim-mcp-server) exposes designUtilities (Tier 2,

Engineering Advanced). Dispatch on utilityType:

{ "utilityType": "boiler", "name": "HP Boiler", "boilerEfficiency": 0.85,
  "duties": [{ "name": "Reboiler", "dutyKW": 5000.0 }] }

| utilityType | Required-ish fields |

|---------------|---------------------|

| boiler | duties [{name,dutyKW}] or dutyKW, boilerEfficiency, fuelLowHeatingValueMJperKg |

| deaerator | feedwaterFlowKgh, feedwaterInletTempC, operatingPressureBara |

| refrigeration | duties or dutyKW, evaporatorTempC, condenserTempC, cycleEfficiency |

| nitrogen | nitrogenDemandNm3h, purityPercent, generationMethod (MEMBRANE\|PSA\|CRYOGENIC) |

| steamNetwork | levels [{name,pressureBara,saturationTempC}], demands [{level,demandKgh}], localGeneration |

The runner returns the class toJson() wrapped by the standard MCP response

envelope. Backend: neqsim.mcp.runners.UtilityDesignRunner.

Agentic utility optimization

UtilityCompressionOptimizer (same package) drives a real two-stage

compression flowsheet (feed → Compressor → intercooler Cooler → Compressor)

through the agentic CODE0

to find the interstage pressure that minimizes total shaft power. It rediscovers

the analytic geometric-mean optimum sqrt(pIn·pOut) from the live model.

import neqsim.process.util.utilitydesign.UtilityCompressionOptimizer;

UtilityCompressionOptimizer opt = new UtilityCompressionOptimizer("Instrument Air");
opt.setInletPressureBara(5.0);
opt.setDeliveryPressureBara(60.0);
opt.setSeed(42L).setMaxEvaluations(70);
opt.optimize();
double pMid = opt.getOptimumInterstagePressureBara(); // ≈ sqrt(5*60) = 17.3 bara
double power = opt.getMinTotalPowerKW();
String json = opt.toJson();

Single decision variable (interstage pressure), custom objective = summed stage

power, deterministic for a fixed seed, never throws. Use as the template for

wiring any utility flowsheet into a closed optimization loop.

Gotchas

Related

Reference cooling water and seawater

Load neqsim-cooling-water for water-cooled

process equipment, seawater utilities, reference IAPWS properties, coolant flow

and pumping. Keep each exchanger side on its own fluid model and distinguish

fixed-salinity bulk utilities from electrolyte chemistry and salt mixing.

Use this skill with your AI agent: Open on Skill Issue to copy, download, or add to your library. Works with Claude, ChatGPT, Gemini, Cursor, Windsurf and more.