Neqsim troubleshooting

From equinor/neqsim · View interactive version

Neqsim troubleshooting is an AI agent skill from the GitHub repository equinor/neqsim. Troubleshoot oil and gas process operating problems and NeqSim simulation failures. Route measured plant disturbances to the root-cause agent. USE WHEN: a simulation fails to converge, produces unexpected results, throws exceptions, or gives zero/NaN values. Covers flash non-convergence, recycle div

How to use this skill

Skill file

NeqSim Troubleshooting Playbook

Start from the reported symptom

For oil and gas process troubleshooting, first establish whether the observation

comes from an instrument, a simulation, or both. Preserve timestamps, units,

operating mode and the last stable period. Route a measured disturbance to

@root-cause with the equipment RCA workflow.

Choose evidence that can distinguish competing causes.

| Observation | Evidence to acquire first | What it can distinguish |

| --- | --- | --- |

| Separator filling or export flow shortfall | Meter directions, all products and boundary crossings, total mass inventories and their uncertainty | Normal accumulation, an unmetered outflow and a flowmeter bias. Use the joint inventory balance. |

| Compressor flow and recycle valve cycling | Synchronized suction and discharge pressure, flow, speed, recycle command and actual position, plus the applicable map | Recycle-loop interaction, a propagated feed disturbance and a local compressor upset. Check event order and control mode. |

| Heat exchanger outlet temperature rising | Hot and cold flows, all four terminal temperatures, pressure drops, bypass position and utility inlet conditions | Changing load or utility temperature, bypass mixing and loss of heat-transfer performance. |

| Downstream liquid carryover | Independent level or inventory, inlet loading, demister differential pressure and downstream liquid evidence | Upstream liquid surges, separator loading and faulty level indication. |

For a numerical failure, reproduce the case from the recorded feed and equipment

settings and use the solver-specific sections below. If a model reproduces a

plant symptom, record which independent measurement could test its proposed cause.

Flash Non-Convergence

Symptom: TPflash() or other flash throws exception or returns wrong phase count.

| Step | Action | Why It Helps |

|------|--------|-------------|

| 1 | fluid.setMultiPhaseCheck(true) | Enables detection of liquid-liquid splits and 3-phase regions |

| 2 | Try a different EOS: SystemPrEos instead of SystemSrkEos | PR handles heavier components better near critical |

| 3 | Check if near critical point — if $T/T_c > 0.95$ and $P/P_c > 0.8$, use volume-translated EOS: SystemSrkEosvolcor | Standard cubic EOS has largest errors near critical |

| 4 | Add fluid.init(0); fluid.init(1); before flash to force re-initialization | Clears stale internal state from prior calculations |

| 5 | Slightly perturb T or P (1 K or 0.1 bar) and re-flash | Exact phase boundary conditions can trap the solver |

| 6 | For mixtures with water + hydrocarbons, use CPA: SystemSrkCPAstatoil with mixing rule 10 | SRK/PR cannot model hydrogen bonding — water phase behavior is wrong |

| 7 | Check component names against src/main/resources/data/COMP.csv | Misspelled component names silently fail or load wrong parameters |

A reused flash gives a different answer from a fresh one

Symptom: a fresh new TPflash(clone).run() finds the expected phases, but the same state flashed by a long-lived

operation (the inner TP flash of a VU, PH or PS flash, a dynamic vessel) loses a phase. Its Gibbs energy is higher,

and the outer flash cycles or needs fallbacks (OptimizedVUflash.wasEquilibriumRecoveryUsed() /

wasEquilibriumPolishUsed() true on ordinary steps).

Check: compare getGibbsEnergy() of the reused result with a fresh flash of a clone. A higher value from the reused

instance means state leaked between runs. Bisect the instance fields by resetting them to a fresh instance's values

before each run. The 2026-11-16 case was the second-order SysNewtonRhapsonTPflash cached on the TPflash.

setSystem keeps u = beta*y (it carries the accepted step within a run), so the first Newton step of a later run

reapplied the previous flash's split. An outer flash that needs history-independent inner results calls

Flash.discardSecondOrderSolver() before each inner run, as OptimizedVUflash does. Do not discard it inside

TPflash.run() itself: TVFlashTest.testTVflash (UMR-PRU) only reaches its lower-Gibbs split through the carried

state, because a fresh TP flash misses that split.

A flash merges gas and oil at one isolated condition

Symptom: a gas/oil/water flash returns one hydrocarbon phase with a density between gas and oil (327 kg/m3 where

gas is 134 and oil 536), while the same fluid 1e-6 bar or 0.01 K away gives three phases.

Check: the 2026-11-21 case (issue 5199) was an unaccepted Newton step in SysNewtonRhapsonTPflash that moved the

phase fraction from 0.80 to -0.55. The next call read it as a converged collapsed phase. A step longer than the

feasible interval (a component moved by more than its feed amount, or the phase fraction by more than one) is now

discarded and TPflash takes a successive substitution step instead (wasLastStepDiscarded()). Shorter unaccepted

steps that cross the phase-fraction limit are still taken, because the endpoint recoveries rely on that collapse.

For a new case, log the phase fraction, the phase types and the deviation per iteration of the two-phase loop in

TPflash.run() and look for a deviation that jumps to about 1 and then to below 1e-10 with the phase fraction at

its limit.

NaN / Zero Enthalpy After Clone + Re-Flash

Symptom: A reservoir/well stream flashes fine at source, but after passing

through WellFlow, PipeBeggsAndBrills, or an isenthalpic choke (or after

clone() + re-flash) it returns NaN enthalpy — often surfacing as NaN

compressor power or a non-finite separator duty downstream.

| Step | Action | Why It Helps |

|------|--------|-------------|

| 1 | Check fluid.getEnthalpy() is finite right after the source TPflash() + initProperties() | Confirms the problem appears only after re-flash, not at the source |

| 2 | If the fluid uses hand-built addTBPfraction pseudo-components, rebuild it from a real PVTsim/E300 characterization (EclipseFluidReadWrite.read) and apply composition via setMolarComposition() | Degenerate ideal-gas Cp coefficients on hand-built fractions lose enthalpy on re-flash; characterized fractions carry full Cp data |

| 3 | Enable fluid.setMultiPhaseCheck(true) before the choke | A trapped/undetected third phase at low pressure can yield a non-finite mix enthalpy |

| 4 | For reservoirs, keep a clean clone of the source fluid for the well stream (bypass SimpleReservoir recombination, which can corrupt enthalpy) | Recombined reservoir fluids can carry inconsistent enthalpy state |

Dynamic-depletion caveat: SimpleReservoir.runTransient() rewrites each

producer stream's fluid in place (via setMolarComposition / setPressure)

with the depleted, recombination-corrected reservoir fluid. If a downstream

topside ProcessModel is re-run after a reservoir transient step, those

overwritten producer fluids can reintroduce NaN enthalpy through the inlet

choke. For lifetime studies, prefer holding a rigorous steady facility

snapshot at plateau for equipment loading and using an analytical

plateau+decline production profile for lifetime volumes/economics, rather than

re-running the topside off each transient depletion step.

Recycle Non-Convergence

Symptom: process.run() completes but recycle did not converge, or throws after max iterations.

| Step | Action | Why It Helps |

|------|--------|-------------|

| 1 | Increase tolerance: recycle.setTolerance(1e-3) (default is ~1e-6) | Tight tolerance may be impossible for complex loops |

| 2 | Add damping: recycle.setFlowAccelerationFactor(0.5) | Prevents oscillation by under-relaxing composition updates |

| 3 | Provide a good initial estimate on the recycle stream (set T, P, flow, composition close to expected) | Poor initial guess causes divergence in early iterations |

| 4 | Run process.run() twice — first run gets close, second run converges | Sequential substitution needs a warm start |

| 5 | Check degrees of freedom — make sure the number of adjusters matches the number of specs | Over/under-specified systems cannot converge |

| 6 | Simplify the loop: temporarily remove non-essential equipment and add back one at a time | Isolates which unit causes instability |

Adjuster Non-Convergence

Symptom: Adjuster fails to find the target value.

| Step | Action | Why It Helps |

|------|--------|-------------|

| 1 | Widen the search bounds: adjuster.setMaxAdjustedValue() / setMinAdjustedValue() | Target may be outside default search range |

| 2 | Set a reasonable initial value: adjuster.setStartValue(initialGuess) | Far-off starting point slows convergence |

| 3 | Increase max iterations: adjuster.setMaxIterations(100) | Complex systems need more iterations |

| 4 | Check that the adjusted variable actually affects the target (verify the physics) | Adjusting the wrong variable cannot converge |

Zero or NaN Property Values

Symptom: getDensity(), getViscosity(), or getThermalConductivity() returns 0.0 or NaN.

| Step | Action | Why It Helps |

|------|--------|-------------|

| 1 | Call fluid.initProperties() after flash | Most common cause. init(3) does NOT initialize transport properties. initProperties() calls both init(2) + initPhysicalProperties() |

| 2 | Check stream.getPropertyInitLevel() / process.getPropertyInitLevel() | Second most common cause in a flowsheet. Stream.PropertyInitLevel.DENSITY_ONLY deliberately skips viscosity, thermal conductivity and diffusivity — they read back as 0.0, not as an error. Set the level back to FULL (per stream, per ProcessSystem, or per ProcessModel area) and re-run |

| 3 | Check fluid.getNumberOfPhases() — property may be for a phase that doesn't exist | Requesting gas-phase viscosity when only liquid exists returns 0 |

| 4 | Use fluid.hasPhaseType("gas") before accessing gas-phase properties | Phase existence varies with conditions |

| 5 | For viscosity at very low pressures (<1 bara), check if the correlation is valid | Some viscosity models have limited pressure range |

| 6 | For mixtures with unusual components (mercury, H2S at trace levels), check if physical property parameters exist in the database | Missing Lennard-Jones or critical parameters give zero |

Feed rebuilt from `getz()` / `getMolarMass()` is silently wrong

getPhase(0).getComponent(i).getz() and getMolarMass() return 0 on a freshly built system until init(0) (or a flash) has run. Rebuilding a wellstream from them (mass flow / molar mass, z * n, setMolarComposition) then gives a divide-by-zero or, worse, a feed whose only non-zero entry is the water you added by hand: the pipe runs, converges and shows a plausible hydrostatic head, but velocities are 3-5x too low and friction is an order of magnitude small. Call fluid.init(0) before reading z or M, assert sum(z) == 1, and add a feed check: stream mass flow equals the target and v = m/(rho A) matches the pipe-model velocity. A Colebrook-White check on a single-phase liquid line against PipeBeggsAndBrills catches it in one run.

Wrong JT / Isenthalpic Expansion Temperature

Symptom: Manual PHflash() on a cloned fluid gives wrong temperature after pressure reduction (Joule-Thomson expansion). Tested: 14.9°C error vs 1.7°C with correct method.

| Step | Action | Why It Helps |

|------|--------|-------------|

| 1 | Use ThrottlingValve in a ProcessSystem instead of manual PHflash() | The valve handles enthalpy bookkeeping correctly; manual PHflash(H/n) uses inconsistent enthalpy reference |

| 2 | Build a mini ProcessSystem: Stream → ThrottlingValve → run() | Only 4 lines of code, always gives correct JT temperature |

| 3 | If you must use PHflash, call it as ops.PHflash(fluid.getEnthalpy()) without dividing by moles | PHflash expects the total system enthalpy at the reference state, not per-mole |

| 4 | Cross-check: compare valve result with ops.PHflash() — if they differ by >2°C, the PHflash call is wrong | ThrottlingValve is the ground truth for isenthalpic expansion |

Correct pattern (Python):

proc = ProcessSystem()
feed = Stream('SG', fluid.clone())
feed.setFlowRate(flow, 'kg/hr')
feed.setTemperature(T, 'C')
feed.setPressure(P_in, 'bara')
proc.add(feed)
valve = ThrottlingValve('JT', feed)
valve.setOutletPressure(P_out)
proc.add(valve)
proc.run()
T_jt = float(valve.getOutletStream().getTemperature('C'))  # Correct JT temperature

Phase Identification Issues

Symptom: Phase labeled "gas" but behavior is liquid-like, or vice versa.

| Step | Action | Why It Helps |

|------|--------|-------------|

| 1 | Check if fluid.setMultiPhaseCheck(true) was called | Without this, solver may miss a phase split |

| 2 | If the fluid uses addTBPfraction / addPlusFraction, verify molar mass was passed in kg/mol, not g/mol | See "Silent g/mol TBP unit error" below — the single most common cause of a bogus one-phase result |

| 3 | For CO2-rich systems near critical, check actual density — phase label may be misleading | CO2 near Tc=304K and Pc=74bar has ambiguous phase identity |

| 4 | Use String.valueOf(phase.getType()) ("GAS" / "OIL" / "AQUEOUS") rather than getPhaseTypeName() | getPhaseTypeName() can report "gas" for a liquid root; getType() is the reliable discriminator |

| 5 | Use fluid.getPhase(0) / getPhase(1) instead of getPhase("gas") if labels are unreliable | Phase index is always consistent even if label is wrong |

| 6 | Run ops.calcPTphaseEnvelope() to visualize phase boundaries | Shows whether operating point is in 1-phase or 2-phase region |

| 7 | For CO2 injection wells, use CO2FlowCorrections.isDensePhase(system) to check T/Tc and P/Pc | Distinguishes dense phase from conventional gas/liquid |

| 8 | For CO2-rich streams, use CO2FlowCorrections.getReducedTemperature(system) and getReducedPressure(system) | Quantifies proximity to critical point |

Silent g/mol TBP unit error

addTBPfraction(name, moles, molarMass, density) and addPlusFraction(...)

expect molar mass in kg/mol. Passing g/mol throws no exception — the

characterization silently produces nonsense pseudo-component properties and the

flash collapses to one phase.

Diagnostic tell: TPflash() at standard conditions (15 °C, 1.01325 bara)

returns getNumberOfPhases() == 1 with getType() == GAS but a density of

700–800 kg/m3. A gas at 1 atm cannot exceed a few kg/m3, so a "gas" phase with

liquid density means the pseudo-components are broken, not that the fluid is

single-phase.

Confirm by printing the pseudo-component properties — the broken case shows

molarMass ~1000x too large, Tc in the thousands of K, and acentricFactor

pinned at -0.99:

for (int i = 0; i < fluid.getNumberOfComponents(); i++) {
  ComponentInterface c = fluid.getComponent(i);
  logger.info("{} MW={} g/mol Tc={} K Pc={} bara omega={}", c.getName(),
      c.getMolarMass() * 1000.0, c.getTC(), c.getPC(), c.getAcentricFactor());
}

Fix: divide by 1000 at the call site —

fluid.addTBPfraction("C10-C12", 0.054, 150.0 / 1000.0, 0.790);

Pipe Outlet Temperature Equals Ambient

Symptom: A PipeBeggsAndBrills tubing string or flowline always arrives at the

ambient / formation temperature, no matter the length, rate or insulation. Hydrate

margins, cooldown times and arrival temperatures all look pessimistic and insensitive.

| Step | Action | Why It Helps |

|------|--------|-------------|

| 1 | Call pipe.setUseOverallHeatTransferCoefficient(true) and pipe.setHeatTransferCoefficient(U) | Without it the pipe behaves as if U were infinite and equilibrates to ambient |

| 2 | Use screening U values: ~15 W/m²K cased/cemented well, ~20 W/m²K uninsulated subsea flowline, ~5 W/m²K wet-insulated | Gives physical wellhead and arrival temperatures |

| 3 | Do not rely on setAdiabatic(true) | It currently leaves the outlet temperature unchanged |

| 4 | Sanity-check the wellhead temperature against expectation before using it downstream | A gas well lifting from 62 °C over 1040 m should arrive near 50 °C, not 5 °C |

CO2 Injection Well Issues

Symptom: CO2 wellbore model gives unexpected phase splits or impurity enrichment.

| Step | Action | Why It Helps |

|------|--------|-------------|

| 1 | Check if formation temperature gradient is set on PipeBeggsAndBrills: pipe.setFormationTemperatureGradient(topC, gradientK, "C") | Without this, pipe uses constant ambient temperature — misses geothermal heating |

| 2 | Use CO2FlowCorrections.isCO2DominatedFluid(system) to verify fluid is >50 mol% CO2 | CO2 correction factors only apply to CO2-dominated systems |

| 3 | After shutdown, use TransientWellbore.runShutdownSimulation() to model cooling transient — don't assume instantaneous equilibration | Wellbore cools exponentially over hours to formation temperature |

| 4 | Attach ImpurityMonitor to streams to track light gas enrichment (H2, N2, Ar) in gas phase | Enrichment factors of 5-15x can occur during phase splits |

| 5 | Set setMultiPhaseCheck(true) on CO2 fluids with impurities | CO2+H2+N2 mixtures can form unexpected two-phase regions |

| 6 | For wellbore elevation, use negative values for downward flow: pipe.setElevation(-1300.0) | Sign convention: negative elevation = flow goes downward |

Distillation Column Non-Convergence

Symptom: Column solver fails after max iterations or produces unreasonable results.

| Step | Action | Why It Helps |

|------|--------|-------------|

| 1 | Try a different solver: NEWTON first, then MESH_RESIDUAL (column.setSolverType(DistillationColumn.SolverType.NEWTON)) | NEWTON, MATRIX_INSIDE_OUT and INSIDE_OUT had no failures in the 2026-11 solver benchmark; sequential substitution and AUTO did. See neqsim-distillation-design, "Default set-up for agent work" |

| 2 | Reduce number of stages and increase back | Start simple, validate, then refine |

| 3 | Check feed stage location — feed too high or low destabilizes | Rule of thumb: feed at ~40-60% of total stages from top |

| 4 | Adjust reflux ratio — start with a high ratio (>2x minimum) and reduce | High reflux is easier to converge |

| 5 | Check condenser/reboiler configuration matches the separation | Total condenser for liquid products, partial for vapor |

Column runs hundreds of iterations / dominates ProcessModel runtime

Symptom: one column takes tens of seconds per solve and the outer

ProcessModel loop never finishes, even though setMaxNumberOfIterations(10)

was called.

| Step | Action | Why It Helps |

|------|--------|-------------|

| 1 | column.setMaxNumberOfIterations(n, true) (or setHardIterationCap(true)) | The 1-arg setter is only a SOFT floor: the effective budget is max(n, 5*trays) plus overflow expansion. Check with getEffectiveMaxNumberOfIterations() |

| 2 | column.setRelaxationFactor(0.3) | The adaptive damping controller clamps at minSequentialRelaxation (default 0.5). setRelaxationFactor lowers that floor, so damping below 0.5 now actually takes effect and breaks tray-temperature limit cycles. setMinSequentialRelaxation / setMinInsideOutRelaxation set it explicitly |

| 3 | column.setTemperatureToleranceRelative(1e-3) | The default absolute tolerance (~0.02-0.03 K) can be 10x tighter than the enclosing ProcessModel gate (1e-3 relative ≈ 0.27 K), so the column chases a residual the plant already accepts |

Column reports solved() == true but the answer is wrong

Symptom: solved() is true, the residuals printed by

getConvergenceDiagnostics() look clean, but the product split, reboiler duty or

tray profile disagrees with every other solver (vapour traffic collapsing

mid-column is a giveaway).

| Step | Action | Why It Helps |

|------|--------|-------------|

| 1 | Read per-tray material imbalance in getConvergenceDiagnostics() (or getLastTrayMaterialBalanceError()) | Anything above getTrayMaterialBalanceTolerance() (default 0.02) means at least one tray does not close its own component balance, so the profile is not a solution even when the overall feed/product balance is closed. Do not use the MESH material: infinity norm for this — it is dominated by trace components |

| 2 | Cross-check with a second solver | Run the same feed through DAMPED_SUBSTITUTION and a simultaneous solver. Agreement within a few percent is evidence; a 30-50 % difference in product split means one of them is wrong |

| 3 | Check getLastSolveStatus() | FALLBACK_PRODUCTS means the products came from an overall feed flash, not the tray solution. FAILED means the solver rejected its own result |

| 4 | Do not loosen setTemperatureTolerance to force a pass | A loosened tolerance can be satisfied by the warm start in a single iteration and returns an unconverged profile that looks converged |

NAPHTALI_SANDHOLM reports Double.NaN as its temperature residual because it

has no successive-substitution sweep. That is intentional: for that solver the

MESH residual vector is the convergence measure, and solved() requires the

MESH gate to be active instead.

ProcessModel Boundary Convergence

Symptom: getConvergenceSummary() reports a relative error but not where it

comes from — most confusingly Flow rate: 1.00e+00.

| Step | Action | Why It Helps |

|------|--------|-------------|

| 1 | model.getWorstBoundaryStreamName("flow") (also "temperature", "pressure") | Names the boundary stream that produced the reported maximum. The summary and getConvergenceReportJson() (errors.flow.worstStream) now include it |

| 2 | model.getNonConvergedBoundaryStreamErrors() | Every boundary stream outside tolerance, worst first, with previousFlow / currentFlow |

| 3 | Check isFlowCollapsedToZero() on the offender | A relative flow error of exactly 1.0 means the stream went from non-zero to zero between outer passes — an upstream unit stopped producing it (failed run, closed splitter, bypassed train). That is an upstream fault, not a slowly converging recycle |

| 4 | Check isFlowStartedFromZero() | Mirror case: a seeded/low-flow stream starting up. Usually harmless, converges on the next pass |

| 5 | Check getAbsoluteFlowChange() on the offender | The decisive test. A large relative error on a tiny absolute change is numerical noise on a stagnant leg, not a process residual |

Symptom: a stagnant dead leg dominates the convergence gate

getConvergenceSummary() reports e.g. Flow rate: 6.56e-02 (gas export ht) and

the model never converges, while the real residual sits on a large stream. The

gate is a max over relative errors, so 0.007 kg/hr of wobble on a

0.1 kg/hr branch beats a genuine 443 kg/hr residual on a 138 t/hr export

stream (3.2e-03).

// 1. Do not solve the stagnant section at all (units auto-bypass).
//    Manifold, ThrottlingValve, PipeBeggsAndBrills and MultiStreamHeatExchanger
//    honour this too, and still publish their outlet pressure at zero flow.
plant.get("HT injection process A").setSectionLowFlowThreshold(50.0, "kg/hr");

// 2. Keep the dead leg out of the plant convergence metric.
plant.setBoundaryFlowFloor(1.0);                      // drop sub-1 kg/hr streams

// 3. Converge on relative OR absolute flow change.
boolean ok = plant.runUntilConverged(15, 1e-3, 1.0);  // rel 1e-3 OR abs 1 kg/hr

Both filters also apply to getNonConvergedBoundaryStreamErrors(), so the

offender list stops being dominated by noise. getConvergenceSummary() prints

the absolute Δflow next to each relative error and a Flow filters: line when a

filter is active.

Prefer the self-configuring form. plant.runUntilConverged(maxIterations)

derives all three filters from the plant's own feed rate, so the hand-picked

1.0 / 1.0 / 50 kg/hr numbers above are only needed when you must override

it. See "Model grinds toward the last decade of the residual" below.

Model grinds toward the last decade of the residual

Symptom: converged=False after the iteration cap, but the residual is

small — e.g. Flow rate: 3.19e-03 against a 1e-3 gate, which is 434 kg/hr on

a 136 t/hr stream. That is slow convergence, not a limit cycle, and it is

usually the gate being tighter than the model is worth.

| Step | Action | Why It Helps |

|------|--------|-------------|

| 1 | Re-run with a larger maxIterations before touching damping | Confirms slow-but-real convergence. A limit cycle plateaus; slow convergence keeps creeping down |

| 2 | Do not call setTolerance() at all | With no explicit tolerance the model uses DEFAULT_ENGINEERING_TOLERANCE (1e-3 relative on flow, T and P) instead of the historical 1e-4. 1e-4 is far tighter than plant instrument or EOS uncertainty |

| 3 | Read model.getAutoToleranceSummary() | States the accuracy actually used. If the residual stalls (<10 % improvement over 5 outer passes) while below getAutoToleranceCeiling() (1e-2), the model accepts it and says so instead of grinding |

| 4 | model.setAutoToleranceCeiling(5e-3) | Tightens the loosest accuracy the model may settle for |

| 5 | model.setAutoTolerance(false) | Opts out entirely and restores the historical 1e-4 default |

// Self-configuring: no tolerance, no noise filters, no per-plant numbers.
boolean ok = plant.runUntilConverged(60);
System.out.println(plant.getAutoTuningSummary());     // flow-noise filters chosen
System.out.println(plant.getAutoToleranceSummary());  // accuracy chosen/accepted

Gotcha: any explicit setTolerance() / setFlowTolerance() /

runUntilConverged(n, tol) marks the tolerance as user-owned and disables

both the engineering default and the stall acceptance. If you set 1e-3

"to be helpful" you also switch off the feature that would have accepted a

stalled 1.4e-3.

Gotcha: setSectionLowFlowThreshold() deactivates units for the remainder

of the solve pass. Do not set it on a section that is legitimately dry only on

the first recycle iteration (e.g. a JT valve on a separator liquid outlet) —

it will never recover within that pass.

"Converged: YES" but a unit is out of mass balance

The plant gate says every boundary stream is inside tolerance, yet

checkMassBalance() flags a downstream unit by ~1 %. The two disagree because

the link between the areas is invisible to boundary detection, not because

the tolerance is too loose.

ProcessModel discovers boundary streams through getInletStreams() /

getOutletStreams(). Equipment that stores its streams in its own private lists

and does not override those two methods falls back to the inherited two-port

inStream/outStream — often never assigned — and so reports no

connections. Such a link is dropped from both the convergence gate and the

incremental dirty-area propagation, so the consumer never gets re-run.

Diagnosis — do not start by loosening tolerances:

  1. List the units that fail mass balance and trace what feeds them.
  2. If only the units fed by one equipment type are unbalanced while every

other unit is exactly 0.0000 %, suspect missing stream introspection on

that type.

  1. Confirm with unit.getInletStreams().size() / getOutletStreams().size() —

a multi-port unit reporting 0 or 1 is the bug.

// Any multi-port equipment MUST expose all ports, or it is invisible to
// topology walks, DEXPI export, ProcessConnection and boundary detection.
List<StreamInterface> in = heatEx.getInletStreams();   // expect all feeds
List<StreamInterface> out = heatEx.getOutletStreams(); // expect all products

Fixed for MultiStreamHeatExchanger in PR #2712; the two-stream

HeatExchanger always overrode both. Apply the same override when adding new

multi-port equipment.

"Converged: YES" while a unit holds NaN

runUntilConverged() can return true for a plant whose equipment carries

NaN results. The boundary gate compares stream values; a unit whose internal

solve produced NaN can still present a self-consistent (nonsense) outlet, so

the gate is satisfied. An older build that reports converged=false may hold

the better numbers.

Therefore, when comparing two NeqSim versions or bisecting a regression, never

classify a run by the convergence flag. Classify on physical finiteness of the

units you care about:

bad = (not math.isfinite(eta) or not math.isfinite(power)
       or outlet_temperature_K < 100.0)   # absolute floor, not a tolerance

TurboExpanderCompressor is a worked example of how one NaN survives:

Math.max(x, 1e-6) returns NaN when x is NaN, and NaN fails every

comparison, so if (N > N_max) / if (N < N_min) speed clamps in the

Newton speed-matching loop never fire. The NaN then reaches efficiency,

power, speed and the outlet flash. Guard with Double.isNaN(...) explicitly —

Math.max/Math.min clamps and >/< bound checks are not guards.

Also check the right object: a standalone Expander built only for reporting

is not the unit the flowsheet solves. Read the coupled unit actually added to

the ProcessSystem.

Process Equipment Errors

Compressor: Negative or Unreasonable Power

| Step | Action |

|------|--------|

| 1 | Verify outlet pressure > inlet pressure |

| 2 | Check that inlet stream has a gas phase |

| 3 | Set polytropic/isentropic efficiency: comp.setIsentropicEfficiency(0.75) |

Separator: No Phase Split

| Step | Action |

|------|--------|

| 1 | Verify fluid has components that can form two phases at the conditions |

| 2 | Run TPflash on the inlet fluid standalone to verify 2+ phases exist |

| 3 | For three-phase, use ThreePhaseSeparator and enable setMultiPhaseCheck(true) on the fluid |

Heat Exchanger: Zero Duty

| Step | Action |

|------|--------|

| 1 | Verify outlet temperature/specification is set |

| 2 | Check that inlet and outlet temperatures are different |

| 3 | For HeatExchanger (two-stream), verify both streams are connected |

Serialization / Copy Errors

Symptom: equipment.copy() or ProcessSystem.copy() throws NotSerializableException.

| Step | Action |

|------|--------|

| 1 | Check for non-serializable fields in custom equipment — mark them transient |

| 2 | Ensure all fields implement Serializable or are primitive types |

| 3 | For lambda expressions in fields, replace with anonymous inner classes |

Performance Issues

Symptom: Simulation runs very slowly.

| Step | Action |

|------|--------|

| 1 | Reduce number of components — merge similar C6+ fractions using lumping |

| 2 | For Monte Carlo, cache expensive results (see neqsim-notebook-patterns skill) |

| 3 | Use SystemSrkEos instead of SystemSrkCPAstatoil if water interaction isn't critical |

| 4 | Reduce iteration limits for screening-level work |

| 5 | Profile with System.currentTimeMillis() around expensive operations |

Common Exception Messages

| Exception | Likely Cause | Fix |

|-----------|-------------|-----|

| ArrayIndexOutOfBoundsException in phase | Component name with + character (e.g., "C20+") | Use "C20" without the + |

| NullPointerException in getPhase("gas") | No gas phase exists at conditions | Check hasPhaseType("gas") first |

| ClassCastException in equipment | Wrong stream type connection | Verify equipment constructors take StreamInterface |

| java.sql.SQLException | Component not in database | Check spelling, verify against COMP.csv |

| StackOverflowError in recycle | Infinite loop in process topology | Check for circular references without a Recycle unit |

| IllegalAccessError / NoSuchMethodError between two NeqSim classes in the same package | Two neqsim-*.jar versions on one classpath | See "Stale or Duplicate Runtime JAR" below |

| Java package 'neqsim.x.y' has no attribute 'Z' for a class that exists in src/ | Installed JAR is older than the repo source | See "Stale or Duplicate Runtime JAR" below |

No JVM Found (JPype Cannot Start Java)

Symptom: JVMNotFoundException, "No JVM shared library file (jvm.dll) found",

or import neqsim failing before any calculation runs.

This is a discovery failure, not a missing installation. On managed corporate

machines Java is routinely installed with no java on PATH and no JAVA_HOME,

and it lands in places a naive scan of C:\Program Files\Java misses: the user

profile, LOCALAPPDATA\Programs, the Windows registry, a JetBrains jbr, or

the JRE shipped inside the VS Code Java extension

(~/.vscode/extensions/redhat.java-*/jre/*).

Recovery, in order:

  1. Was this even a code task? A single flash/property/sizing question needs

no local JVM at all — use the curated mcp_neqsim_* tool (see

neqsim-api-patterns § "MCP server vs. Python/Java API").

  1. Find the installed Java instead of hunting by hand:

```powershell

uv run --project devtools --locked devtools/java_locator.py # source checkout: usable Javas, best first

neqsim doctor # plugin / pip install: names the found Java

```

  1. Make it usable for this process — no admin, no persisted env change:

```python

import neqsim_dev_setup, sys, pathlib

sys.path.insert(0, str(pathlib.Path(neqsim_dev_setup.file).parent))

from java_locator import ensure_java_home

ensure_java_home() # sets JAVA_HOME + PATH in-process

import neqsim

```

The sys.path line is needed because an editable devtools install resolves

modules through a map frozen at install time. neqsim_dev_setup.neqsim_init(...)

already does all of this, so notebooks and NeqSim Runner jobs are covered.

  1. Persist it for Maven and future terminals (user scope, no admin):

```powershell

[Environment]::SetEnvironmentVariable('JAVA_HOME','<home from step 2>','User')

```

  1. Only if the locator finds nothing, install Java — a portable Temurin JDK

unpacked into the user profile needs no admin rights. neqsim doctor prints

this remedy with the exact commands.

A JRE is enough to run NeqSim through JPype; mvnw compilation needs a full

JDK (bin/javac). The locator ranks JDKs above JREs for this reason.

Stale or Duplicate Runtime JAR

The Python package adds its lib/* folder to the classpath as a flat glob, so a

JAR left behind by an earlier install is loaded alongside the current one.

Classes then resolve across two versions of the same package.

Symptom: an access or linkage error between two classes that are provably in

the same package and legal in source, e.g.

`IllegalAccessError: class ...ProcessModelOperatingActionSetEvaluator tried to

access private method ...HydraulicConstraintBinding.<init>(...)`.

Do not go looking for a Java access-modifier bug. Check the JAR count first:

Get-ChildItem <venv>\Lib\site-packages\neqsim\lib\*.jar
python -c "import importlib.metadata as m; print(m.version('neqsim'))"

Keep only the JAR matching the installed package version. `python

devtools/neqsim_doctor.py` reports this as "Single NeqSim JAR on runtime

classpath".

Related symptom — version skew, not a missing class: has no attribute 'X'

for a class that exists under src/main/java/ means the released JAR predates

<revision> in pom.xml. Point the run at workspace classes instead:

NEQSIM_TEST_CLASSPATH=target/classes plus dependencies, or use the

devtools/neqsim_dev_setup.py bootstrap.

Replacing a JAR under a live JVM (notebook kernel) is a third variant: the

copy succeeds but any class not already loaded fails to resolve. Restart the

kernel; a JVM cannot reload a JAR in-process.

Phase Envelope Branch Labels Swapped

Load neqsim-phase-envelope for the canonical structured segment API, physical dew/bubble

classification, numerical-zero component behavior, and solver-change test protocol. Use this

section for symptom-driven recovery after following that workflow.

Symptom: When plotting a phase envelope calculated with calcPTphaseEnvelope(true, 1.0),

the bubble and dew curves appear swapped — the "bubble" array has higher temperatures

(cricondentherm) which is physically the dew side, and vice versa.

Cause: The Michelsen continuation algorithm always starts with isDewPhase=true

regardless of the bubblePointFirst flag. When tracing from the bubble side first,

initial points go into the dew list. At the critical point the flag flips, so actual

dew-side data ends up in the bubble list.

Fix: Classify branches by physical reasoning, NOT by method names:

# The DEW curve always contains the cricondentherm (maximum temperature)
if np.array(envelope.getBubblePointTemperatures()).max() > np.array(envelope.getDewPointTemperatures()).max():
    dew_T = np.array(envelope.getBubblePointTemperatures())  # swapped!
    bub_T = np.array(envelope.getDewPointTemperatures())     # swapped!
else:
    dew_T = np.array(envelope.getDewPointTemperatures())
    bub_T = np.array(envelope.getBubblePointTemperatures())

Gas-condensate PVT pitfalls (found while building a CVD/CCE depletion model)

new composition. In a hand-written CVD loop scale extensive values by the total moles you track, otherwise the material balance goes

negative after a few steps ("Mole fractions must sum to a positive value").

(NIP-01); use a CCE loop with an explicit dew-point reference and treat the first 50 bar of retrograde liquid as under-predicted.

before trusting it for rich gas condensate.

When All Else Fails

  1. Simplify radically — reduce to 2-3 components, remove equipment, test one unit at a time
  2. Check a known-good case — run an existing test (e.g., SeparatorTest) to verify NeqSim works
  3. Compare with standalone flash — take the inlet fluid, run TPflash manually, check phases
  4. Search existing tests — grep_search for similar equipment/components in src/test/java/neqsim/
  5. Report the issue — if it's a genuine NeqSim bug, file a GitHub issue with minimal reproducer