Neqsim trapped liquid fire rupture

From equinor/neqsim · View interactive version

Neqsim trapped liquid fire rupture is an AI agent skill from the GitHub repository equinor/neqsim. Fire rupture studies for blocked-in liquid-filled pipe segments and blowdown pipe heat-up / strain-rate time-to-rupture. USE WHEN: a task involves trapped or blocked-in liquid, thermal expansion rupture, fire exposure without relief, PFP demand, flange/pipe rupture screening, a supplied blowdown pre

How to use this skill

Skill file

Fire Rupture Study

This skill coordinates two related fire-rupture workflows:

overpressure the pipe/flange system; and

combined with wall heat-up, temperature-dependent material data, and a

Sellars-Tegart strain-rate model to estimate time to rupture.

For both workflows, gather evidence, preserve assumptions and gaps, run the

appropriate NeqSim safety.rupture calculation, hand off any rupture source term,

and produce a professional report output.

For source-document-driven blowdown pipe-fire studies, use the governed handoff

layer instead of calling the low-level solver directly: build

SafetyEvidenceReference entries, assemble a PipeFireRuptureDataSource, run

PipeFireRuptureStudyRunner, and report the returned

PipeFireRuptureStudyHandoff. This preserves calculation readiness, standards

readiness, deterministic uncertainty cases, and the post-rupture source-term

handoff in one JSON-safe package.

When the blowdown pressure profile has not yet been generated, first use the

dynamic flare/blowdown layer from neqsim-depressurization-mdmt: assemble

LineEquipmentListEvidence and DynamicBlowdownFlareStudyDataSource, run

DynamicBlowdownFlareStudyRunner, and use the returned source pressure profiles

and dynamic_blowdown_flare_load_handoff.v2 as the governed basis for the

pipe-fire rupture profile and flare/consequence handoff.

Use the workflow generically. Do not encode operator-specific criteria in public

examples. If a private task has project-specific acceptance criteria, keep them

inside the task folder and cite the private basis only in that task deliverable.

When to Use

trapped liquid, blocked-in liquid, or no pressure relief on liquid-filled piping.

matrix showing missing project data.

to screen pipe wall heat-up, accumulated strain, rupture time, and release rate.

an engineer before calculation.

Skills to Load Together

certificates, fire-zone/PFP documents, relief studies, and design basis documents.

Excel, P&ID images, line lists, and material certificates.

part of the mitigation.

dispersion, fire, explosion, or QRA calculations.

Evidence Retrieval Checklist

Before running the calculation, search the task references folder and any

configured document backend for:

| Evidence | Purpose in calculation |

|----------|------------------------|

| P&ID / isometric | Isolation boundary, valves, vents, drains, relief paths, line numbers |

| Line list / route table | NPS, internal diameter, wall thickness, length, design pressure/temperature |

| Piping specification | Material class, corrosion allowance, flange class, gasket/bolt family |

| Material certificate or material class sheet | SMYS, SMTS, grade, temperature limits, toughness notes |

| Flange/bolt/gasket data | Pressure-temperature rating and leakage/rupture limitations |

| Fire-zone / fire-study document | Exposed area, heat flux, pool/jet-fire basis, fire duration |

| PFP requirement or inspection record | Required endurance and actual protection condition |

| Relief/thermal relief/blowdown basis | Relief availability, set pressure, discharge path, creditability |

| Blowdown pressure profile | Time/pressure table, units, absolute/gauge convention, source calculation |

| Pipe fire material curve | Temperature-dependent UTS, strain effect, rupture strain limit, Sellars-Tegart constants |

| Pipe fluid basis | Fluid density, heat capacity, gas molecular weight, gas/liquid release basis |

| Design basis / technical requirements | Acceptance criteria, required margins, standards, reporting basis |

| Consequence or layout study | Source-term destination, escalation, radiation, dispersion context |

If any item is missing, do not invent it. Use a clearly labelled screening

default only when the result can still support a preliminary decision, and put

the gap in the assumptions/gaps register.

Extraction Schema

Technical document readers should return a block like this to the solver:

{
  "study_type": "trapped_liquid_fire_rupture",
  "segments": [
    {
      "segment_id": "TL-001",
      "line_numbers": ["..."],
      "isolation_boundary": {"upstream": "XV-...", "downstream": "XV-..."},
      "fluid": {"description": "...", "composition_source": "..."},
      "operating_pressure_bara": {"value": 10.0, "source": "..."},
      "operating_temperature_C": {"value": 25.0, "source": "..."},
      "pipe_internal_diameter_m": {"value": 0.10, "source": "..."},
      "wall_thickness_m": {"value": 0.003, "source": "..."},
      "exposed_length_m": {"value": 10.0, "source": "..."},
      "material_grade": {"value": "API 5L X52", "source": "..."},
      "flange_class": {"value": 900, "source": "..."},
      "fire_basis": {"type": "api521_pool_fire", "heat_flux_W_m2": null, "source": "..."},
      "pfp_requirement_s": {"value": 1800.0, "source": "..."},
      "relief": {"available": false, "set_pressure_bara": null, "source": "..."},
      "acceptance_criteria": [{"criterion": "...", "source": "..."}],
      "evidence_gaps": ["..."]
    }
  ]
}

Every numeric field should preserve original value, original unit, converted SI

value, source document, page/sheet, and confidence when available.

For blowdown pipe fire rupture, technical document readers or source-document agents

should return a block like this:

{
  "study_type": "blowdown_pipe_fire_rupture",
  "segment_id": "BD-001",
  "pressure_profile": {
    "time_unit": "minute",
    "pressure_unit": "bara",
    "basis": "absolute pressure profile from governed blowdown calculation",
    "points": [[0.0, 61.3], [0.083333333, 59.7053]]
  },
  "pipes": [
    {
      "pipe_id": "3DD100",
      "pipe_class": "DD100",
      "nps_in": 3.0,
      "outside_diameter_mm": 88.9,
      "wall_thickness_mm": 3.7,
      "corrosion_allowance_mm": 0.0,
      "wall_undertolerance_fraction": 0.125,
      "weld_factor": 1.0,
      "material": "22Cr duplex",
      "fluid_density_kg_m3": 23.75,
      "fluid_heat_capacity_J_kgK": 2283.35,
      "gas_molecular_weight_kg_kmol": 18.2,
      "initial_temperature_C": 20.0,
      "exposed_length_m": 1.0,
      "source": "reviewed piping specification / workbook input"
    }
  ],
  "fire_scenarios": ["Small jet fire 250 kW/m2", "Pool fire 250 kW/m2", "Large jet fire 350 kW/m2"],
  "evidence_gaps": []
}

Governed Source-Document Handoff Schema

When pipe data comes from source drawings and piping-specification rows, normalize it into a

source-traceable package before NeqSim calculation:

{
  "schemaVersion": "pipe_fire_rupture_data_source.v1",
  "studyId": "BD-001",
  "input": {"segmentId": "3DD100", "evidenceReferences": []},
  "material": {"materialName": "22Cr duplex"},
  "scenario": {"name": "Large jet fire 350 kW/m2"},
  "pressureProfile": {"pressureUnit": "bara", "timeUnit": "seconds"},
  "pidTopologyEvidence": {
    "schemaVersion": "pid_topology_evidence.v1",
    "drawingId": "P-ID-001",
    "revision": "A",
    "simulationReady": false,
    "boundaryVerified": false,
    "nodes": [],
    "edges": [],
    "missingTags": []
  },
  "sourceDocumentEvidence": [],
  "pipingSpecificationEvidence": [],
  "processEvidence": [],
  "fireScenarioEvidence": [],
  "sourceDiagramsReviewed": true,
  "pidTopologyVerified": false,
  "pipingSpecificationRowsReviewed": true,
  "materialCertificateReviewed": false,
  "blowdownProfileVerified": true,
  "fireScenarioReviewed": true,
  "standardsReviewed": false,
  "humanReviewRequired": true,
  "readiness": {"verdict": "SCREENING"}
}

Readiness semantics:

or pressure profile). Do not run the calculation.

prevent design-grade use.

has been reviewed and the package is ready for formal engineering review.

Quick Screening: Blocked-In Liquid Thermal Expansion (No Fire)

Before committing to a full fire-exposure rupture study, BlockedInLiquidExpansionAnalysis

(neqsim.process.util.fire) provides a fast, fire-independent check of pure thermal-expansion

overpressure for a blocked-in liquid segment, per API 521 ยง4.4.12:

SystemInterface oil = new SystemSrkEos(298.15, 10.0);
oil.addComponent("n-heptane", 100.0);
oil.setMixingRule("classic");

double[] temperaturesK = {298.15, 308.15, 318.15, 328.15, 333.15};
double[] pressuresPa =
    BlockedInLiquidExpansionAnalysis.computeIsochoricPressureProfile(oil, temperaturesK);

// Fast cross-check using the simplified API 521 beta/kappa relation
double beta = BlockedInLiquidExpansionAnalysis.estimateThermalExpansionCoefficient(oil, 1.0);
double kappa = BlockedInLiquidExpansionAnalysis.estimateIsothermalCompressibility(oil, 1.0e5);
double deltaPPa = BlockedInLiquidExpansionAnalysis.simplifiedPressureRise(beta, kappa, 35.0);

Use this when the task only needs a thermal-expansion magnitude (e.g. deciding whether a thermal

relief valve is needed) without a fire scenario, material derating, or flange/pipe-stress checks.

See docs/safety/blocked_in_liquid_thermal_expansion.md

for the full reference.

Java Calculation Pattern

SystemInterface oil = new SystemSrkEos(298.15, 10.0);
oil.addComponent("n-heptane", 100.0);
oil.setMixingRule("classic");

InventoryResult inventory = new TrappedInventoryCalculator()
    .setFluid(oil)
    .setOperatingConditions(10.0, "bara", 25.0, "C")
    .addPipeSegment("TL-001", 0.10, 10.0, 1.0, null)
    .calculate();

TrappedLiquidFireRuptureResult result = TrappedLiquidFireRuptureStudy.builder()
    .segmentId("TL-001")
    .fluid(oil)
    .inventory(inventory)
    .pipeGeometry(0.10, "m", 3.0, "mm", 10.0, "m")
    .api5lMaterial("X52")
    .fireScenario(FireExposureScenario.api521PoolFire(3.4, 1.0))
    .flangeClass(900)
    .timeControls(1800.0, 2.0)
    .build()
    .run();

Key classes:

flange rating, vapor-pocket, relief-set, and rupture checks.

and source-term handoff.

For supplied-pressure-profile blowdown pipe fire rupture:

BlowdownPressureProfile profile = BlowdownPressureProfile.fromMinutesAndBara(
  new double[] {0.0, 0.083333333, 0.166666667},
  new double[] {61.3, 59.7053, 58.6349});

PipeFireRuptureInput pipe = PipeFireRuptureInput.builder("3DD100")
  .pipeClass("DD100")
  .nominalDiameterInches(3.0)
  .outsideDiameter(88.9, "mm")
  .nominalWallThickness(3.7, "mm")
  .corrosionAllowance(0.0, "mm")
  .wallThicknessUndertoleranceFraction(0.125)
  .weldFactor(1.0)
  .fluidDensityKgPerM3(23.75)
  .fluidHeatCapacityJPerKgK(2283.35)
  .gasMolecularWeightKgPerKmol(18.2)
  .initialTemperatureC(20.0)
  .exposedLength(1.0, "m")
  .build();

PipeFireRuptureResult pipeResult = PipeFireRuptureStudy
  .builder(pipe, PipeFireRuptureMaterial.fromSpreadsheetMaterialName("22Cr duplex"),
    PipeFireRuptureScenario.spreadsheetLargeJetFire(), profile)
  .timeStepSeconds(5.0)
  .maxTimeSeconds(1800.0)
  .build()
  .run();

For governed agentic studies, prefer the runner pattern:

SafetyEvidenceReference pipingSpecWall = SafetyEvidenceReference
  .builder("PIPING_SPEC", "nominal_wall_thickness_mm")
  .documentId("pipe-class=DD100;rev=D")
  .valueText("3.7")
  .unit("mm")
  .status("fetched_joined")
  .confidence(0.95)
  .build();

PipeFireRuptureInput governedPipe = pipe.toBuilder()
  .evidenceReference(pipingSpecWall)
  .build();

PipeFireRuptureDataSource dataSource = PipeFireRuptureDataSource.builder("BD-001")
  .input(governedPipe)
  .material(PipeFireRuptureMaterial.fromSpreadsheetMaterialName("22Cr duplex"))
  .scenario(PipeFireRuptureScenario.spreadsheetLargeJetFire())
  .pressureProfile(profile)
  .addPipingSpecificationEvidence(pipingSpecWall)
  .sourceDiagramsReviewed(true)
  .pidTopologyVerified(false)
  .pipingSpecificationRowsReviewed(true)
  .materialCertificateReviewed(false)
  .blowdownProfileVerified(true)
  .fireScenarioReviewed(true)
  .standardsReviewed(false)
  .build();

PipeFireRuptureStudyHandoff handoff = PipeFireRuptureStudyRunner.builder()
  .timeStepSeconds(5.0)
  .maxTimeSeconds(1800.0)
  .runUncertainty(true)
  .build()
  .run(dataSource);

Key pipe-fire classes:

DynamicBlowdownFlareStudyHandoff: governed dynamic depressurization, PSV, and flare-load setup used to create a

source-traceable pressure profile before pipe-fire rupture screening.

Reusable Safety Report Template

For governed source-document pipe-fire studies, the Word/HTML report should use a

repeatable evidence-first structure. At minimum include:

  1. Executive verdict with NOT_READY, SCREENING, or DESIGN_GRADE, plus

the human-review status.

  1. Evidence matrix with source system, document id, revision, page/sheet,

field, extracted value, unit, status, confidence, and notes.

  1. Source drawing table with drawing id, revision, embedded-text/OCR

status, topology nodes/edges count, missing tags, and overlay/annotation link.

  1. Piping specification table with applicable revision, class/material references, NPS,

outside diameter, wall thickness, corrosion allowance, undertolerance, and

row-review status.

  1. NeqSim input lineage mapping each solver input to its SafetyEvidenceReference.
  2. Standards-applied table covering API 521 / ISO 23251, NORSOK S-001,

piping/material basis, and consequence/source-term handoff status.

  1. Assumptions and gaps register with severity, effect on result, and required

action before design use.

  1. Calculation results and uncertainty including rupture time, rupture pressure,

wall temperature, release estimate, deterministic perturbation cases, and

P10/P50/P90 where available.

  1. Source-term handoff using pipe_fire_rupture_source_term_handoff.v1 when

rupture is predicted.

  1. Calculation lineage from document field to NeqSim input to reported result.

Before the report is considered complete, apply these hard QA gates:

current task_spec.md and results.json; no placeholder text may remain.

SCREENING, or DESIGN_GRADE) and whether design-grade use is blocked.

report must agree on the pressure-profile basis. If the task moved from a

reconstructed profile to a direct dynamic NeqSim profile, update all four.

notebooks to not required; do not create false notebook execution warnings.

workflow/code gaps, including reporting, evidence-readiness, pressure-profile

export, plant-data evidence, and governed handoff gaps.

alongside the conclusions, not only in appendix-style detail.

Results to Save

Save a trapped_liquid_fire_rupture section in results.json:

{
  "trapped_liquid_fire_rupture": {
    "segments": [
      {
        "segment_id": "TL-001",
        "limiting_failure_mode": "PIPE_RUPTURE",
        "time_to_pipe_rupture_s": 420.0,
        "time_to_flange_failure_s": null,
        "minimum_failure_time_s": 420.0,
        "final_pressure_bara": 145.0,
        "final_wall_temperature_C": 530.0,
        "pfp_required_endurance_s": 1800.0,
        "pfp_margin_s": -1380.0,
        "evidence_gaps": ["Material certificate not found"],
        "recommendations": ["Provide thermal relief or documented PFP upgrade"]
      }
    ],
    "standards_applied": ["API 521", "ISO 23251", "ASME B31.3", "ASME B16.5"],
    "assumptions": ["Generic API 5L X52 screening curve used pending certificate"],
    "evidence_matrix": []
  }
}

For Standard/Comprehensive studies, include:

For blowdown pipe fire rupture, save a pipe_fire_rupture section in

results.json:

{
  "pipe_fire_rupture": {
    "segment_id": "BD-001",
    "pressure_profile_basis": "absolute bara profile from governed blowdown model",
    "pipes": [
      {
        "pipe_id": "3DD100",
        "fire_scenario": "Large jet fire 350 kW/m2",
        "rupture_predicted": true,
        "time_to_rupture_s": 110.0,
        "rupture_pressure_barg": 32.03,
        "rupture_wall_temperature_C": 760.0,
        "release_estimate_kg_s": 21.9,
        "evidence_gaps": []
      }
    ],
    "standards_applied": ["API 521", "ASME B31.3"],
    "assumptions": ["Spreadsheet material curve used pending certificate review"]
  }
}

For governed studies, also persist the runner handoff:

{
  "pipe_fire_rupture_handoff": {
    "schemaVersion": "pipe_fire_rupture_study_handoff.v1",
    "calculationReadiness": {"verdict": "SCREENING"},
    "standardsReadiness": {"verdict": "SCREENING"},
    "result": {},
    "uncertainty": {"schemaVersion": "pipe_fire_rupture_uncertainty.v1"},
    "sourceTermHandoff": {"schemaVersion": "pipe_fire_rupture_source_term_handoff.v1"}
  }
}

Validation and Benchmarking

workbook or an independent spreadsheet before scaling to all pipe cases.

and release calculations use barg, while the pressure profile is often supplied

as bara and converted by subtracting 1 bar.

specialist flange/gasket assessment, FEA, or consequence modelling as needed.

Common Mistakes

| Mistake | Fix |

|---------|-----|

| Using a generic flange class as final proof | Replace with project flange, bolt, and gasket pressure-temperature data |

| Crediting relief without a discharge path | Verify relief/thermal relief path on P&ID and relief design basis |

| Ignoring vents/drains | Include them in the isolation boundary and trapped-volume assessment |

| Assuming PFP is installed and intact | Require PFP specification and inspection/condition evidence |

| Reporting only rupture time | Also report assumptions, evidence gaps, PFP margin, and source-term consequence handoff |

| Treating pressure-profile units casually | Record whether the profile is bara or barg and convert explicitly |

| Letting superduplex map to 22Cr duplex | Use PipeFireRuptureMaterial.fromSpreadsheetMaterialName or a reviewed material curve |

| Running plant-wide pipe-fire cases without review | Ask the engineer to verify source-document, piping-specification, and user overrides before calculation |

Related Documentation