Neqsim self heating ignition

From equinor/neqsim · View interactive version

Neqsim self heating ignition is an AI agent skill from the GitHub repository equinor/neqsim. Self-heating and spontaneous-ignition screening for reactive porous media (lagging fires) - Frank-Kamenetskii and Semenov criticality, critical thickness and surface temperature, induction time, Arrhenius fitting from basket tests (EN 15188 / ASTM E2021). USE WHEN: a flammable liquid leak onto insul

How to use this skill

Skill file

NeqSim Self-Heating and Spontaneous Ignition Skill

Screening for low-temperature self-heating leading to spontaneous ignition —

the mechanism behind lagging fires, where a combustible liquid soaks into porous

thermal insulation and ignites with no external ignition source.

When this skill applies

Reach for this skill when you see any of these signals:

identified ignition source**.

lubricating oil, hydraulic fluid, amine, diesel — onto or into **porous

insulation** (mineral wool, glass wool, calcium silicate, perlite).

safe?", "how thick can the lagging be?", "why did it catch fire hours

after the leak stopped?"*

extrapolate small-scale test data to plant scale.

The one thing to get right

Self-heating is a size-dependent problem, not a temperature-only problem.

Heat is generated throughout the volume (scales with $r^3$) but lost through the

surface (scales with $r^2$). So the same material at the same temperature can be

perfectly stable as a thin film and ignite as a thick layer.

This is why the lumped adiabatic screening in

neqsim.process.safety.reaction.RunawayReactionAnalyzer **cannot answer this

question** — it assumes a well-stirred mass with no spatial conduction, so it has

no concept of a critical thickness or a critical surface temperature. Do not

substitute it. Use neqsim.process.safety.selfheating.

Equally, **do not use a Gibbs/equilibrium calculation to decide whether something

self-ignites.** GibbsReactor will report that any hydrocarbon is fully oxidised

to CO₂ and H₂O at 20 °C, because that is thermodynamically true and kinetically

irrelevant. Equilibrium gives you the fuel ($\Delta H$); only kinetics give you

the hazard.

Model selection

| Situation | Model | Class |

|---|---|---|

| Liquid absorbed in insulation, internal gradients matter (Bi ≫ 1) | Frank-Kamenetskii | PorousMediaSelfHeatingAnalyzer |

| Drained pool, thin film, small sample; uniform temperature (Bi ≪ 1) | Semenov | SemenovSelfHeatingAnalyzer |

| When will it ignite, not just whether | Transient 1-D conduction + Arrhenius source | SelfHeatingInductionSolver |

| Fitting E and P from oven test data | Linearised criticality regression | BasketTestRegression |

Governing relations

Frank-Kamenetskii criticality parameter:

$$

\delta = \frac{E\,P\,r^{2}}{\lambda\,R\,T_a^{2}}\exp\!\left(-\frac{E}{R\,T_a}\right)

$$

with $P = A\,Q\,\rho$ the volumetric heat-release pre-exponential factor [W/m³],

$E$ the activation energy [J/mol], $r$ the characteristic half-dimension [m],

$\lambda$ the effective conductivity of the wetted medium [W/(m·K)] and $T_a$

the boundary temperature [K]. A steady state exists only while

$\delta \le \delta_{crit}$, where $\delta_{crit}$ depends only on shape:

slab 0.878, infinite cylinder 2.00, sphere 3.32, cube 2.52, equicylinder 2.76.

Semenov criticality parameter, $\psi_{crit} = 1/e$:

$$

\psi = \frac{E\,V\,P}{h\,S\,R\,T_a^{2}}\exp\!\left(-\frac{E}{R\,T_a}\right)

$$

Standard workflow

1. Get the kinetics — they are measured, never calculated

$E$ and $P$ cannot come from thermodynamics. Sources, in order of preference:

  1. Basket / hot-storage test on the actual soaked material → BasketTestRegression.
  2. Published data for the same liquid/substrate pair.
  3. A screening estimate, clearly flagged as an assumption in results.json.
BasketTestRegression fit = new BasketTestRegression();
fit.setEffectiveThermalConductivity(0.09);       // wetted insulation, not dry
fit.addPoint(SelfHeatingGeometry.CUBE, 25.0, "mm", 168.0, "C");
fit.addPoint(SelfHeatingGeometry.CUBE, 50.0, "mm", 149.0, "C");
fit.addPoint(SelfHeatingGeometry.CUBE, 100.0, "mm", 132.0, "C");
BasketTestRegressionResult k = fit.regress();
// k.getActivationEnergyJPerMol(), k.getVolumetricPreFactorWPerM3(), k.getRSquared()

Require at least three basket sizes and check getRSquared() before trusting the fit.

2. Screen the plant-scale geometry

PorousMediaSelfHeatingResult r = k
    .createAnalyzer(SelfHeatingGeometry.SLAB, 50.0, "mm", 180.0, "C")
    .analyze();

r.getVerdict();                 // SUBCRITICAL / MARGINAL / SELF_IGNITION
r.getCriticalTemperatureK();    // hottest safe surface for this thickness
r.getCriticalDimensionM();      // thickest safe layer at this temperature

For lagging on a hot line, use the convenience configuration, which applies a

conservative bounding assumption (slab half-dimension = full insulation thickness,

boundary temperature = pipe wall temperature) and records that assumption in

getWarnings():

new PorousMediaSelfHeatingAnalyzer()
    .setEffectiveThermalConductivity(0.09)
    .setActivationEnergy(110.0, "kJ/mol")
    .setVolumetricHeatReleasePreFactor(5.0e13)
    .forPipeInsulation(50.0, "mm", 180.0, "C")
    .analyze();

3. If supercritical, get the induction time

SelfHeatingInductionResult t = new SelfHeatingInductionSolver()
    .setGeometry(SelfHeatingGeometry.SLAB)
    .setCharacteristicDimension(50.0, "mm")
    .setEffectiveThermalConductivity(0.09)
    .setBulkProperties(150.0, 1200.0)      // bulk density, specific heat
    .setActivationEnergy(110.0, "kJ/mol")
    .setVolumetricHeatReleasePreFactor(5.0e13)
    .setBoundaryTemperature(180.0, "C")
    .setMaxTime(30.0, "day")
    .solve();

t.isIgnited();
t.getInductionTimeHours();     // typically hours to days — not seconds

4. Hand off the consequence

A predicted ignition is a source term, not the end of the study. Continue to

neqsim-consequence-analysis (pool/jet fire radiation) and

neqsim-relief-flare-network if the fire exposes pressurised equipment.

Input guidance and common mistakes

| Input | Guidance | Common mistake |

|---|---|---|

| $\lambda$ effective conductivity | Use the wetted composite value; absorbed liquid displaces pore air and raises it well above the dry rating | Using the dry insulation datasheet value — non-conservative |

| $r$ characteristic dimension | Must match SelfHeatingGeometry.getDimensionDescription() (half-thickness for a slab, radius for cylinder/sphere) | Passing full thickness where half-thickness is expected, or vice versa |

| $P$ pre-factor | $P = A\,Q\,\rho$ where $\rho$ is reactive liquid mass per bulk volume, not the insulation density | Using insulation bulk density instead of liquid loading |

| $T_a$ boundary temperature | The hot process surface, not ambient air, for lagging on a hot line | Using ambient air temperature — badly non-conservative |

| Geometry for transient solver | Only SLAB / INFINITE_CYLINDER / SPHERE are one-dimensional | Passing CUBE to SelfHeatingInductionSolver (rejected) |

Interpreting the verdict

steady self-heating excess is only a few kelvin, so there is **no temperature

warning before runaway**.

thickness or surface temperature tip it over. Recommend confirmatory testing.

as a credible fire scenario.

Reporting

Populate results.json with:

critical_thickness_mm, induction_time_hours, verdict

conductivity basis, and the pipe-insulation bounding assumption if used

Mitigation hierarchy (for recommendations)

  1. Eliminate absorbency — closed-cell or non-absorbing insulation, so there is

no porous matrix to hold the liquid and trap the heat. This removes the

mechanism rather than managing it, and is normally the correct recommendation.

  1. Prevent wetting — eliminate the leak; fit liquid-tight cladding and

drainage that sheds leakage clear of the lagging.

  1. Reduce thickness below the critical dimension, or lower the surface

temperature below the critical temperature.

  1. Detect and inspect — remove and replace contaminated insulation promptly;

note that detection is weak as a sole barrier because the pre-runaway

temperature signature is only a few kelvin.

Related skills

Use this skill with your AI agent: Open on Skill Issue to copy, download, or add to your library. Works with Claude, ChatGPT, Gemini, Cursor, Windsurf and more.