NeqSim Process Modeling Skill
Build executable NeqSim process simulations from engineering descriptions. This skill
is the process-flowsheet layer between thermodynamic fluid setup and downstream
specialists such as mechanical design, safety, plant data, and reporting.
Use When
- Building a
ProcessSystemorProcessModelflowsheet from a process description. - Connecting equipment such as streams, separators, compressors, coolers, heaters,
heat exchangers, pumps, valves, pipes, mixers, splitters, recycles, adjusters, and
distillation columns.
- Extracting process results with units, compositions, duties, powers, phase splits,
mass balances, energy balances, or equipment profiles.
- Preparing a steady-state process base case for mechanical design, relief sizing,
flow assurance, dynamic simulation, plant-data comparison, or optimization.
Core Workflow
- Agree the model basis: engineering question, battery limits, feed/assay,
units, product specifications, data provenance and required fidelity. Follow
model-build-contract for every new or
revised flowsheet; use its handoff checklist when another agent consumes it.
- Select the task pattern from
oil-and-gas-task-patterns. Load only
the relevant specialist skills. Discover additional capabilities rather than
treating an equipment class name as proof of a validated application. For
several platforms exchanging streams (hub plus satellites, shared export chain)
load multi-platform-complex.
- Define fluids and feeds with the EOS/component sequence in
neqsim-api-patterns. Verify the EOS and phase options for the composition,
pressure/temperature range and property being calculated.
- Assemble a reusable builder with named streams/equipment, live outlet
connections, explicit terminal products and one ProcessSystem per area.
Return the process/plant and stream/equipment registries, not just numbers.
- Solve progressively: establish the feed and once-through base case,
close physical recycles, then add adjusters and operating constraints. Use
makeRecycles() or setAutoRecycles(true) for supported mixer/manifold loops.
For coupled models, check the boolean from runUntilConverged(n) and retain
residual/iteration evidence. A returned run() call is not convergence proof.
- Validate each accepted case: external total/component balances, energy
closure where heat/work matters, phase identity, feasible equipment limits,
independent benchmark and repeat/nearby-point behavior. Missing evidence
stays incomplete; never insert zero as a closure result.
- Deliver reusable outputs with explicit units, inputs, version, assumptions,
data gaps, failed cases and validation evidence. Store notebooks/scripts in
the task folder; publish sanitized examples only when requested.
Do not silently fill composition, heavy-end characterization, maps, geometry,
Cv, design limits or protection settings from generic defaults. A synthetic
screening case may use labeled assumptions; an asset-specific verdict must
identify missing decision-critical data. A thermodynamic operating-point model
can answer duties without establishing installed capacity or safe operation.
Modeling Choices
| Situation | Recommended Pattern |
|-----------|---------------------|
| Single train, linear or branched flowsheet | One ProcessSystem |
| Multiple areas with cross-area streams | Multiple ProcessSystem objects in a ProcessModel |
| Production / gathering / commingling / export manifold or inlet header | Manifold (process.equipment.manifold.Manifold) — NOT Mixer/Splitter |
| PFD/P&ID or unstructured text input | Use neqsim-process-extraction first |
| Distillation or fractionation | Load neqsim-distillation-design |
| Startup, shutdown, controllers, inventory dynamics | Load neqsim-dynamic-simulation |
| Turndown or control valve operability | Load neqsim-controllability-operability |
| Platform-scale separation/recompression | Load neqsim-platform-modeling |
Manifolds: always model a well/production/gathering/commingling/export
manifold (or an inlet/outlet header) with the Manifold class, not a plain
Mixer or Splitter. Add the routed inlet streams with addStream(...). **A
manifold ALWAYS has split outlets — route downstream from a split stream, never
from getMixedStream().** If the manifold feeds a single destination, give it
one split (setSplitFactors([1.0])) and route its getSplitStream(0). For a
distributing manifold set setSplitFactors([f0, f1, ...]) (fractions summing to
1) and read each branch with getSplitStream(i). getMixedStream() returns only
the internal commingled stream (all inlets combined, before the split) — use it
for inspection, not for wiring downstream. The Manifold also carries
header/branch inner diameters (setHeaderInnerDiameter, setBranchInnerDiameter)
for hydraulics and mechanical design.
Data Basis for an Optimization-Ready Model
A model built only to run has fixed operating points. A model built to
optimize additionally needs a bounded decision space, equipment constraints,
and an objective. Gather this basis up front (and record every assumed value):
- Fluid & feed — composition(s) + PVT/assay (C7+); feed rate, T, P, water
cut/GOR per feed; EOS + mixing rule.
- Geometry & hydraulics — line sizes (ID, schedule/wall, length, elevation,
roughness, insulation), manifold/header sizes, separator/scrubber dimensions
(ID, T/T length, orientation, nozzle sizes), heat-exchanger area/UA.
- Valves & chokes — **control-valve Cv/Kv, rated travel, characteristic,
opening; choke Cv-vs-opening (bean/trim)** for wells and let-down; ESD sizes.
- Rotating equipment — compressor maps (head/eff vs flow at several speeds) +
design/max speed; pump curves (+ NPSHr); driver rating (GT/motor); anti-surge
config (surge line, control-line margin, recycle-valve Cv).
- Design limits → constraints — separator design gas-load K + residence time;
compressor rated power, surge/stonewall margins, max discharge T; pump power +
NPSHa; line erosional-velocity limit; design P/T; valve max Cv; MAWP; PSV set P.
- Decision space & control — manipulable setpoints with physical bounds
(stage pressures, temperatures, compressor discharge P or speed, split/routing);
compressor control mode (solve-speed vs predictive — see
neqsim-agentic-process-optimization); pre-wired adjusters (do not also optimize).
- Objective & economics — objective (max throughput / min power / max value /
min emissions); product specs as constraints (RVP, dew point, cricondenbar,
Wobbe); prices / power & fuel cost / CO2 price for value objectives.
Source geometry and Cv from the line list, valve/choke datasheets, and instrument
index; maps from vendor curve sheets; limits from datasheets + piping class. For
the governed enterprise checklist and readiness gates use
enterprise-process-model-build-verify (target_fidelity="optimization_ready").
For MCP runProcess compressor protection, keep embedded compressor
antiSurge as screening control only. Use root-level antiSurgeSystems when
the model must bind CompressorAntiSurgeApplication to explicit named hot/cold
recycle valves, cooler, suction mixer, and recycle blocks. Multi-area systems
must include area. Follow neqsim-compressor-antisurge-recycle for the JSON
contract, screening-map provenance, commissioning evidence, and the mandatory
NOT_CERTIFIED_FOR_PROTECTION boundary.
Per-Area Three-Phase Flash Control (Speed-Up)
Switch the multiphase (three-phase) flash off on areas that are known to be
two-phase only. On a multi-area plant this is usually the cheapest speed-up
available, because the extra phase-stability analysis otherwise runs on every
flash of every unit of every recycle iteration.
plant.setMultiPhaseCheck(true); // baseline for all areas
plant.setMultiPhaseCheck("Export train A", false); // dry gas: no third phase
compressionTrain.setMultiPhaseCheck(false); // a single ProcessSystem
ProcessSystem.setMultiPhaseCheck(boolean)returns the number of distinct
fluids updated; getMultiPhaseCheck() returns TRUE/FALSE/null (unset).
ProcessModel.setMultiPhaseCheck(String areaName, boolean)returns-1for an
unknown area name — check it, do not assume the call landed.
- The setting is re-applied at the start of each run, so a
ThreePhaseSeparator
temporarily enabling the check cannot leak three-phase mode into the area.
- Default is unset: fluids keep whatever flag they were built with.
**Only disable it where the absence of a third phase is known from the process,
not assumed.** Free water, an aqueous glycol/MEG phase, or a liquid CO2 phase
will be silently missed. Keep the check ON for inlet separation, produced-water,
glycol/MEG, and CO2-rich areas.
Per-Area Property-Initialization Level (Speed-Up)
Every Stream.run() ends with initProperties(), which evaluates mass density,
viscosity, thermal conductivity and diffusivity. Selecting DENSITY_ONLY skips
the transport-property correlations and is roughly an order of magnitude cheaper
per stream.
plant.setPropertyInitLevel(Stream.PropertyInitLevel.DENSITY_ONLY); // whole plant
plant.setPropertyInitLevel("Subsea", Stream.PropertyInitLevel.FULL); // one area
compressionTrain.setPropertyInitLevel(Stream.PropertyInitLevel.DENSITY_ONLY);
feedStream.setPropertyInitLevel(Stream.PropertyInitLevel.FULL); // one stream
- Same API shape as
setMultiPhaseCheck:ProcessSystem.setPropertyInitLevel
returns the number of streams updated, `ProcessModel.setPropertyInitLevel(area,
level) returns -1` for an unknown area, the setting propagates into nested
ModuleInterface sub-processes, is applied to units added afterwards, and is
re-applied at the start of every run.
- Default is unset (
null): each stream keepsPropertyInitLevel.FULL.
⚠
DENSITY_ONLYmakes transport properties read back as ZERO, not throw.
getViscosity(),getThermalConductivity()and the diffusion coefficients
return
0.0. That silently corrupts pipeline pressure drop, heat-exchanger UA,
mechanical design, and every flow-assurance calculation. Use it only for
mass/energy-balance solves, and set the level back to
FULL(or call
getFluid().initProperties()on the stream) before reading transport
properties.
Both switches are re-applied by run(UUID), run_step(UUID),
runSequential(UUID), runParallel(UUID), runHybrid(UUID),
runDataflow(UUID) and runTransient(double, UUID).
Parallel runs with GERG-2008 / EOS-CG.
runParalleland other multi-threaded
drivers are safe with GERG-2008 (incl. H2/NH3 variants) and EOS-CG: the wrappers
hold one kernel per thread, and
ReferenceEosThreadConfinementTestrequires
concurrent results to match serial ones exactly. Each branch must still own its
fluid —
clone()it; never share one fluid, phase or wrapper across threads.
Details:
docs/thermo/gerg2008_eoscg.md("Thread safety").
Closing Feedback Loops Automatically (`makeRecycles`)
Do not hand-write a tear stream (Stream clone + Recycle) per feedback
stream any more. A loop wired straight back into an upstream mixer, with no
Recycle in it, is an implicit tear: it converges only through the surrounding
sweep, so it has no tolerance, no acceleration and no convergence report. Across
ProcessModel areas it is worse — a stream produced by an area that runs after its
consumer is closed only by the outer Gauss-Seidel pass, which has no relaxation
setting, so the plant residual sits on a floor no tolerance can reach.
created = process.makeRecycles() # ProcessSystem — SCCs of one flowsheet
created = plant.makeRecycles() # ProcessModel — cross-area streams, then each area
plant.setAutoRecycles(True) # or let run()/runUntilConverged() do it
- Tear point = inlet with the smallest recycle ratio (tear flow / total inlet
flow of the consuming unit), which sets the contraction rate of the tear. One edge
torn per round, structure recomputed after — nested cycles get the minimum number
of tears.
- Generated recycles start on direct substitution with
setAdaptiveAcceleration(true)
(never pin setAccelerationMethod(...) — that sets accelerationMethodExplicit and
disables the self-upgrade) plus an absolute flow tolerance at 1e-6 of the area's
largest flow, so a near-zero leg converges on absolute change.
- Self-seeding (runs once when streams have no fluid) and idempotent — call order is
not your problem, repeat calls insert nothing.
- Only
MixerandManifoldinlets are tearable (replaceStream(int, StreamInterface)).
Loops closing on other equipment are logged and left alone; route them through a mixer.
setAutoRecyclesdefaults to false: inserting a tear changes how an existing
flowsheet iterates, so it must be opted into.
Required Checks
- Temperatures and pressures use explicit units in setters.
- Fluids have a mixing rule before simulation.
- Branching streams use cloned fluids or well-defined equipment outlet streams.
- Phase-separating equipment exposes conventional gas/liquid product accessors;
domain aliases return those same objects rather than separate streams.
getInletStreams()andgetOutletStreams()contain every externally connected,
live stream. Their entries remain object-identical across reruns so downstream
equipment never retains a stale product reference.
- After solving a phase separator or column, verify the gas outlet contains a gas
phase, the liquid outlet contains an oil/liquid/aqueous phase, and total plus
per-component balances close. Getter existence alone is not product validation.
- Every equipment item has a unique name inside the process.
- Recycles and adjusters are added after their connected equipment.
- Pick the separator class by orientation, or set it explicitly. Gas-capacity
results depend on orientation because a horizontal vessel derates the gas area by
the design liquid level (default 80% → gas area (1−0.8)=0.2×, a 5× over-read
of gas velocity / getGasLoadFactor() if used for a vertical vessel):
SeparatorandThreePhaseSeparatordefault to horizontal — use for the
horizontal 1st/2nd/3rd-stage separators (VA-tag).
GasScrubber,GasScrubberSimple,NeqGasScrubber(2-phase) and
ThreePhaseGasScrubber (3-phase) default to vertical — prefer these for
vertical scrubbers (VG-tag); their constructor calls setOrientation("vertical").
- Either way you can override with
separator.setOrientation("vertical"|"horizontal").
Verified: with the correct orientation, getGasLoadFactor() matches a hand
Souders-Brown v·sqrt(ρg/(ρl−ρg)). setInternalDiameter() itself propagates
correctly through run() — the trap is orientation, not diameter.
- Every suction/interstage/export scrubber liquid outlet has a physical route to
an appropriate pressure section or a declared external drain/product. Include
required letdown/pumping and heat/work; a TP setter is not a physical pressure
lift. Preserve all returns in recovery and boundary balances. Consult
neqsim-platform-modeling for initialization patterns, with the routing and
validation requirements in the model-build contract.
- Overall mass balance MUST be verified before accepting any solution. Sum the mass
flow (kg/hr) of all feed streams and all product/export streams; the closure error
must be < 0.1 % (abs(sum_in - sum_out) / sum_in). A larger imbalance means a stream
was dropped (e.g. an unconnected scrubber liquid), a recycle did not converge, or a
splitter fraction is wrong — fix the flowsheet and re-run; do NOT report results from an
unbalanced model. For multi-area ProcessModels, also confirm plant.run() converged.
- Results include the verified mass balance, expected pressure ordering, and physically
reasonable phase splits.
- For industrial engineering use, assess every exact
method@versionwith
EngineeringMethodQualificationRegistry: require an independent benchmark, approved structured applicability
envelope, intended use, controlled service inputs, uncertainty basis and explicit extrapolation policy. A converged
calculation outside the envelope remains investigation evidence, not a qualified engineering result.
- Use
EngineeringNumericalHealthAnalyzerto capture convergence, mass/energy closure, residual, and sensitivity
evidence for every process state that governs an engineering decision. Required but absent evidence must remain
INCOMPLETE; never replace unavailable closure data with zero.
- Use
Dexpi20XmlWriterfor native Plant/P&ID exchange andDexpi20ProcessModelWriterfor native Process/PFD/BFD
exchange. A Proteus document with a changed header is not native DEXPI 2.0. Preserve the conformance report and still
require a named-CAE round-trip before project qualification.
- To rebuild a runnable model from a Proteus P&ID (including NeqSim's own
DexpiXmlWriteroutput), use
DexpiSimulationBuilder with an explicit fluid template and feed, then check getDiagnostics() for missing outlet
specifications before run(). Native DEXPI 2.x files are rejected; DEXPI does not carry composition.
- Keep an explicitly registered terminal product as
new Stream(productName, upstreamOutlet)when the product must
remain a named topology node. NeqSim reports the wrapped outlet as that stream's inlet and the DEXPI Process exporter
maps the node to a sink. Zero-flow and isolated empty streams must not be deleted merely to avoid invalid empty port
collections.
- An isolated
new Stream(name)with no fluid runs as an inactive topology placeholder. Do not connect downstream
thermodynamic equipment to that placeholder until a real fluid state is assigned.
- Use
Cfihos20HandoverExporteronly with an exact project-controlled CFIHOS 2.0 Core or Extended RDL delivery.
Verify its digest from controlled bytes, map canonical nodes/properties/documents to exact RDL identifiers, record
mapping approval, and close the generated gap register. Its CSVs are staging data; Principal transformation,
target-system validation, contractual completeness, and information acceptance remain external decisions.
- Compressor, pump, heat exchanger, separator, and pipeline cases identify applicable
standards through neqsim-standards-lookup.
Process Safety Is Part of a Capacity or Tie-in Study
A capacity, debottlenecking or tie-in study that reports only throughput is
incomplete, and in an oil-and-gas setting it will not pass review. **More flow
through a plant changes its relief demand, its blowdown inventory and its
overpressure exposure.** Run these checks in the same study, not as a follow-on:
- Overpressure protection per affected pressure section. Record design
pressure/MAWP, PSV set pressure, operating pressure, protected equipment and
source/reference conditions. Investigate discrepancies using the applicable
project/code basis; do not excuse them with an invented rounding allowance or
confuse set pressure with allowable accumulation.
- Relief adequacy against credible governing cases. Use
neqsim-relief-flare-network with documented scenarios, inflow and device data.
Compare required capacity with installed capacity including applicable backpressure.
A small relief load does not by itself establish adequate blowby protection or
credit a shutdown function. Missing protection evidence remains a gap.
- Inflow bounding. The maximum flow into each pressure step is set by the
upstream chokes and control valves. Without a choke Cv the blowby and
overpressure cases cannot be closed from first principles — record that as a
gap rather than assuming a number.
- Blowdown. Restriction-orifice sizes give the depressurisation time
(neqsim-depressurization-mdmt); without them, state that time-to-blowdown is
unknown.
- The safety meaning of an over-capacity vessel. A separator or scrubber
above its Souders-Brown gas-load limit carries liquid over into downstream
equipment. That is a safety finding, not only a production one: liquid to
a compressor, liquid to a dehydration bed, liquid to the flare KO drum. If a
capacity calculation shows an exceedance, follow the carry-over path and say
what it reaches.
Ordering rule. Establish the capacity answer first, then the safety
consequence of it — the safety question depends on which unit is loaded and by
how much. Reporting capacity without step 5 is the most common way a
throughput-increase study is quietly wrong.
Data-retrieval expectations (verified on an NCS platform): design pressure
and relief-device orifice/rated capacity are typically not tag attributes in
an engineering register — they live in the mechanical and relief data sheets and
often need OCR. Budget for that. Vessel geometry on a tag record may be an
L×W×H envelope rather than an internal diameter; **where a data sheet exists it
governs the tag field**, and the difference can move a utilisation result by tens
of percent.
Related Skills
neqsim-api-patterns— fluid setup, equipment APIs, and result extraction.neqsim-input-validation— pre-simulation physical bounds and component checks.neqsim-troubleshooting— flash and process convergence recovery.neqsim-process-extraction— JSON builder and route extraction from documents.neqsim-notebook-patterns— executable notebook structure and devtools setup.neqsim-process-safety— barrier, HAZOP, LOPA and SIL framing for the safety
step above.
neqsim-relief-flare-network— PSV sizing per API 520/521 and flare loads.neqsim-depressurization-mdmt— blowdown time and low-temperature screening.neqsim-future-operation-study— per-year strategy, modification register and
design-basis deviation register on top of a finished multi-year model.
Diagnose unresolved recycles before accepting a plant result
After ProcessSystem.runUntilConverged(n), inspect getRunStatus().isConverged()
and getOpenRecycles(). RunStatus.isSuccess() means execution did not fail;
it does not prove numerical convergence. The status also names open loops,
reports their count, the full-process pass count and a termination reason.
Never accept repeated mass-balance values as a convergence criterion while loops
remain open. Separator constraints expose getRawValue(), getDesignLimit(),
getUnit() and getBasis(); built-in limits are defaults and explicit setters
are custom unless actual datasheet provenance is declared.
Ejector (gas-jet compressor) pitfalls
neqsim.process.equipment.ejector.Ejector (motive + suction streams, discharge pressure, four efficiencies) is a design-point model by default (both flows are inputs, setThroatArea is a no-op, generatePerformanceCurve has a constant entrainment ratio). For an
installed ejector at a new year / motive pressure / gas MW use the fixed-geometry mode: setFixedGeometry(throatM2, mixingM2) (or setFixedGeometryAreaRatio),
autoSizeFixedGeometry(designSuctionFlow, 0.10) to size it once, then run(); flows are results (getOperatingPoint(), getOperatingWindowReport(), isInBreakdown(),
getBreakdownMargin(), generateFixedGeometryCurve). Pitfalls: stream flow rates are ignored in this mode (use setLimitEntrainmentToSuctionSupply(true) to cap by supply),
only the vapour phase is used, the regimes are CRITICAL / SUBCRITICAL (entrainment falling) / BREAKDOWN (ER = 0), and a subcritical result is not a capacity guarantee.
See docs/process/equipment/ejectors.md. Practical rules learned on an ejector off-design study:
- Outlet stream:
run()used to replacemixedStream(jneqsim 3.18: every run); wire downstream equipment to aMixeroutlet (adiabatic energy balance = the
ejector outlet state, kinetic terms cancel) or re-fetch getMixedStream() after each run.
- Suction must be vapour: a two-phase suction gas (4th stage gas + cold flare gas) makes any 1-D isentropic nozzle model return nonsense (entrainment 8x too high); knock the
liquid out first and use the gas phase (fluid.phaseToSystem("gas")).
- Capacity vs motive pressure: a constant-pressure-mixing model gives a HIGHER capacity at lower motive pressure (primary jet area shrinks); never throttle the motive
pressure to turn down - model turndown as recycle at full motive pressure (motive flow is fixed by throat area x choked flux).
- Critical back pressure margin (
P_cb / P_d - 1) is the robust off-design indicator; a lighter suction gas or a falling motive pressure moves it to breakdown long before
the entrainment ratio looks wrong. Size with ~10 % margin and re-check every year / case with the FIXED geometry.
- Compressors downstream see the motive gas as extra flow and a much lower MW (25-30 vs 44-46 g/mol design): check head / speed / surge / stonewall on the vendor charts with the actual MW.
For a fixed minimum-flow compressor return at suction state, see
neqsim-compressor-antisurge-recycle and MinimumFlowSpill in the compressor guide.
Reference cooling water and seawater
Load neqsim-cooling-water for water-cooled
process equipment, seawater utilities, reference IAPWS properties, coolant flow
and pumping. Keep each exchanger side on its own fluid model and distinguish
fixed-salinity bulk utilities from electrolyte chemistry and salt mixing.